Axis P13 Series User manual

AXIS P13 Series
AXIS P1364 Network Camera
AXIS P1365 Network Camera
Installation Guide
Available from A1 Security Cameras

Legal Considerations
Video and audio surveillance can be regulated by laws that
vary from country to country. Check the laws in your local
region before using this product for surveillance purposes.
This product includes one (1) H.2 4 decoder license and
one (1) AAC decoder license. To purchase further licenses,
contact your reseller.
Liability
Every care has been taken in the preparation of this
document. Please inform your local Axis ofce of any
inaccuracies or omissions. Axis Communications AB cannot
be held responsible for any technical or typographical errors
and reserves the right to make changes to the product and
manuals without prior notice. Axis Communications AB
makes no warranty of any kind with regard to the material
contained within this document, including, but not limited
to, the implied warranties of merchantability and tness for
aparticular purpose. Axis Communications AB shall not
be liable nor responsible for incidental or consequential
damages in connection with the furnishing, performance
or use of this material. This product is only to be used for
its intended purpose.
Intellectual Pro erty Rights
Axis AB has intellectual property rights relating to
technology embodied in the product described in this
document. In particular, and without limitation, these
intellectual property rights may include one or more of
the patents listed at www.axis.com/patent.htm and one or
more additional patents or pending patent applications in
the US and other countries.
This product contains licensed third-party software. See
the menu item “About” in the product’s user interface for
more information.
This product contains source code copyright Apple Computer,
Inc., under the terms of Apple Public Source License 2.0
(see www.opensource.apple.com/apsl). The source code is
available from https://developer.apple.com/bonjour/
Equi ment Modications
This equipment must be installed and used in
strict accordance with the instructions given in the
user documentation. This equipment contains no
user-serviceable components. Unauthorized equipment
changes or modications will invalidate all applicable
regulatory certications and approvals.
Trademark Acknowledgments
AXIS COMMUNICATIONS, AXIS, ETRAX, ARTPEC and VAPIX
are registered trademarks or trademark applications of Axis
AB in various jurisdictions. All other company names and
products are trademarks or registered trademarks of their
respective companies.
Apple, Boa, Apache, Bonjour, Ethernet, Internet Explorer,
Linux, Microsoft, Mozilla, Real, SMPTE, QuickTime, UNIX,
Windows, Windows Vista and WWW are registered
trademarks of the respective holders. Java and all
Java-based trademarks and logos are trademarks or
registered trademarks of Oracle and/or its afliates.
UPnPTM is acertication mark of the UPnPTM Implementers
Corporation.
SD, SDHC and SDXC are trademarks or registered trademarks
of SD-3C, LLC in the United States, other countries or both.
Also, miniSD, microSD, miniSDHC, microSDHC, microSDXC
are all trademarks or registered trademarks of SD-3C, LLC
in the United States, other countries or both.
Regulatory Information
Europe
This product complies with the applicable CE marking
directives and harmonized standards:
• Electromagnetic Compatibility (EMC) Directive
2004/108/EC. See Electromagnetic Compatibility (EMC)
2.
• Low Voltage (LVD) Directive 200 /95/EC. See afety 3.
• Restrictions of Hazardous Substances (RoHS) Directive
2011/ 5/EU. See Disposal and Recycling 3.
Acopy of the original declaration of conformity may be
obtained from Axis Communications AB. See Contact
Information 3.
Electromagnetic Com atibility (EMC)
This equipment has been designed and tested to fulll
applicable standards for:
• Radio frequency emission when installed according to
the instructions and used in its intended environment.
• Immunity to electrical and electromagnetic phenomena
when installed according to the instructions and used
in its intended environment.
USA
AXIS P1364:
This equipment has been tested using an unshielded
network cable (UTP) and found to comply with the limits
for aClass Adigital device, pursuant to part 15 of the FCC
rules. This equipment has also been tested using ashielded
network cable (STP) and found to comply with the limits for
aClass Adigital device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection
against harmful interference when the equipment is
operated in acommercial environment. This equipment
generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in
aresidential area is likely to cause harmful interference
in which case the user will be required to correct the
interference at his own expense.
Canada
AXIS P1364: This digital apparatus complies with
CAN ICES-3 (Class A). The product shall be connected
using ashielded network cable (STP) that is properly
grounded. Cet appareil numérique est conforme àla norme
NMB ICES-3 (classe A). Le produit doit être connecté à
l'aide d'un câble réseau blindé (STP) qui est correctement
mis àla terre.
Europe
AXIS P1364: This digital equipment fullls the
requirements for RF emission according to the Class Alimit
of EN 55022. The product shall be connected using a
shielded network cable (STP) that is properly grounded.
Notice! This is aClass Aproduct. In adomestic environment
this product may cause RF interference, in which case the
user may be required to take adequate measures.
This product fullls the requirements for immunity
according to EN 1000- -1 residential, commercial and
light-industrial environments.
This product fullls the requirements for immunity
according to EN 1000- -2 industrial environments.
This product fullls the requirements for immunity
according to EN 55024 ofce and commercial
environments.
Australia/New Zealand
Available from A1 Security Cameras

AXIS P1364: This digital equipment fullls the
requirements for RF emission according to the Class Alimit
of AS/NZS CISPR 22. The product shall be connected using
ashielded network cable (STP) that is properly grounded.
Notice! This is aClass Aproduct. In adomestic environment
this product may cause RF interference, in which case the
user may be required to take adequate measures.
Japan
AXIS P1364: この装置は、クラスA 情報技術装置で
す。この装置を家庭環境で使⽤すると電波妨害 を
引き起こすことがあります。この場合には使⽤者
が適切な対策を講ずるよう要求され ることがあり
ます。 本製品は、シールドネットワークケーブル
(STP)を使⽤して接続してください。また適切に接
地してください。
Korea
AXIS P1364: 이기기는 업무용(A급) 전자파적합기
기로서 판매자 또는 사용자는 이점을 주의하시기
바라며, 가정외의 지역에서 사용하는 것을 목적으
로합니다. 적절히 접지된 STP (shielded twisted
pair) 케이블을 사용하여 제품을 연결 하십시오.
Safety
This product complies with IEC/EN/UL 0950-1, Safety of
Information Technology Equipment. If its connecting cables
are routed outdoors, the product shall be grounded either
through ashielded network cable (STP) or other appropriate
method.
The power supply used with this product shall fulll
the requirements for Safety Extra Low Voltage
(SELV) and Limited Power Source (LPS) according to
IEC/EN/UL 0950-1.
Dis osal and Recycling
When this product has reached the end of its useful life,
dispose of it according to local laws and regulations. For
information about your nearest designated collection point,
contact your local authority responsible for waste disposal.
In accordance with local legislation, penalties may be
applicable for incorrect disposal of this waste.
Europe
This symbol means that the product shall not be
disposed of together with household or commercial waste.
Directive 2012/19/EU on waste electrical and electronic
equipment (WEEE) is applicable in the European Union
member states. To prevent potential harm to human health
and the environment, the product must be disposed of in
an approved and environmentally safe recycling process.
For information about your nearest designated collection
point, contact your local authority responsible for waste
disposal. Businesses should contact the product supplier for
information about how to dispose of this product correctly.
This product complies with the requirements of
Directive 2011/ 5/EU on the restriction of the use of
certain hazardous substances in electrical and electronic
equipment (RoHS).
C ina
This product complies with the requirements of the
legislative act Administration on the Control of Pollution
Caused by Electronic Information Products (ACPEIP).
Contact Information
Axis Communications AB
Emdalavägen 14
223 9 Lund
Sweden
Tel: +4 4 272 18 00
Fax: +4 4 13 1 30
www.axis.com
Su ort
Should you require any technical assistance, please contact
your Axis reseller. If your questions cannot be answered
immediately, your reseller will forward your queries through
the appropriate channels to ensure arapid response. If you
are connected to the Internet, you can:
• download user documentation and software updates
• nd answers to resolved problems in the FAQ database.
Search by product, category, or phrase
• report problems to Axis support staff by logging in to
your private support area
• chat with Axis support staff
• visit Axis Support at www.axis.com/techsup/
Learn More!
Visit Axis learning center www.axis.com/academy/ for
useful trainings, webinars, tutorials and guides.
Available from A1 Security Cameras

Available from A1 Security Cameras

AXIS P13 Series
Safety Information
Read through this Installation Guide carefully before installing the product. Keep the Installation
Guide for future reference.
Hazard Levels
DANGER
Indicates ahazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Indicates ahazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Indicates ahazardous situation which, if not avoided, could result in minor or moderate
injury.
NONO
NOTICETICE
TICE
Indicates asituation which, if not avoided, could result in damage to property.
Other Message Levels
Important
Indicates signicant information which is essential for the product to function correctly.
Note
Indicates useful information which helps in getting the most out of the product.
5
Available from A1 Security Cameras

AXIS P13 Series
Safety Instructions
NONO
NOTICETICE
TICE
•The Axis product shall be used in compliance with local laws and regulations.
•To use the Axis product outdoors, or in similar environments, it shall be installed in an
approved outdoor housing.
•Store the Axis product in adry and ventilated environment.
•Avoid exposing the Axis product to shocks or heavy pressure.
•Do not install the product on unstable brackets, surfaces or walls.
•Use only applicable tools when installing the Axis product. Using excessive force with
power tools could cause damage to the product.
•Do not use chemicals, caustic agents, or aerosol cleaners.
•Use aclean cloth dampened with pure water for cleaning.
•Use only accessories that comply with the technical specication of the product. These
can be provided by Axis or athird party.
•Use only spare parts provided by or recommended by Axis.
•Do not attempt to repair the product yourself. Contact Axis support or your Axis reseller
for service matters.
•The power supply shall be plugged in to asocket outlet installed near the product and
shall be easily accessible.
•Use alimited power source (LPS) with either arated output power limited to ≤100 Wor a
rated output current limited to ≤5A.
Trans ortation
NONO
NOTICETICE
TICE
•When transporting the Axis product, use the original packaging or equivalent to prevent
damage to the product.
Battery
The Axis product uses a3.0 VCR2032 lithium battery as the power supply for its internal real-time
clock (RTC). Under normal conditions this battery will last for aminimum of ve years.
Low battery power affects the operation of the RTC, causing it to reset at every power-up. When
the battery needs replacing, alog message will appear in the product’s server report. For more
information about the server report, see the product´s setup pages or contact Axis support.
The battery should not be replaced unless required, but if the battery does need replacing, contact
Axis support at www.axis.com/techsup for assistance.
6
Available from A1 Security Cameras

AXIS P13 Series
Lithium coin cell 3.0 Vbatteries contain 1,2-dimethoxyethane; ethylene glycol dimethyl ether
(EGDME), CAS no. 110-71-4.
WARNING
•Risk of explosion if the battery is incorrectly replaced.
•Replace only with an identical battery or abattery which is recommended by Axis.
•Dispose of used batteries according to local regulations or the battery manufacturer's
instructions.
7
Available from A1 Security Cameras

AXIS P13 Series
Installation Guide
This Installation Guide provides instructions for installing AXIS P13 4/P13 5 Network Camera
on your network. For other aspects of using the product, see the User Manual available at
www.axis.com
Installation Ste s
1. Make sure the package contents, tools and other materials necessary for the installation
are in order. See page 9.
2. Study the hardware overview. See page 10.
3. Study the specications. See page 14.
4. Install the hardware. See page 17.
5. Access the product. See page 18.
. Set the focus. See page 18.
Package Contents
• Network Camera
- AXIS P13 4
- AXIS P13 5
• Connector kit
• Camera stand
• Allen key TR20
• Printed materials
- Installation Guide (this document)
- Extra serial number label (2x)
- AVHS Authentication key
9
Available from A1 Security Cameras

AXIS P13 Series
Hardware Overview
1tatus LED
2Built-in microphone
3micro D card slot
4Audio in
5Audio out
6Network connector (PoE)
7Power LED
8Network LED
9Control button
10 I/O connector
11 Iris connector
12 Power connector (DC)
13 R 485/422 connector
10
Available from A1 Security Cameras

AXIS P13 Series
AXI P1364 AXI P1365
1Focus ring
2Lock screw for focus ring
3Zoom puller
LED Indicators
Note
•The Status LED can be congured to be unlit during normal operation. To congure, go
to Setup >System Options >Ports &Devices >LED.See the online help for more
information.
•The Status LED can be congured to ash while an event is active.
•The Status LED can be congured to ash for identifying the unit. Go to Setup >System
Options >Maintenance .
Status LED Indication
Green Steady green for normal operation.
Amber Steady during startup. Flashes when restoring settings.
Network LED Indication
Green Steady for connection to a100 Mbit/s network. Flashes for
network activity.
Amber Steady for connection to a10 Mbit/s network. Flashes for
network activity.
Unlit No network connection.
11
Available from A1 Security Cameras

AXIS P13 Series
Power LED Indication
Green Normal operation.
Amber Flashes green/amber during rmware upgrade.
Status LED Behavior for Focus Assistant
The status LED ashes when the Focus Assistant is active.
Color Indication
Red The image is out of focus.
Adjust the lens.
Amber The image is close to focus.
The lens needs ne tuning.
Green The image is in focus.
Connectors and Buttons
For specications and operating conditions, see page 14.
Network Connector
RJ45 Ethernet connector with Power over Ethernet (PoE).
NONO
NOTICETICE
TICE
Due to local regulations or the environmental and electrical conditions in which the product
is to be used, ashielded network cable (STP) may be appropriate or required. All cables
connecting the product to the network and that are routed outdoors or in demanding
electrical environments shall be intended for their specic use. Make sure that the network
devices are installed in accordance with the manufacturer’s instructions. For information
about regulatory requirements, see Electromagnetic Compatibility (EMC) 2.
I/O Connector
Use with external devices in combination with, for example, tampering alarms, motion detection,
event triggering, time lapse recording and alarm notications. In addition to the 0VDC reference
point and power (DC output), the I/O connector provides the interface to:
• Digital output –For connecting external devices such as relays and LEDs. Connected
devices can be activated by the VAPIX® Application Programming Interface, output
buttons on the Live View page or by an Action Rule. The output will show as active
(shown under System Options >Ports &Devices)if the alarm device is activated.
12
Available from A1 Security Cameras

AXIS P13 Series
• Digital input –An alarm input for connecting devices that can toggle between an open
and closed circuit, for example: PIRs, door/window contacts, glass break detectors,
etc. When asignal is received the state changes and the input becomes active (shown
under System Options >Ports &Devices).
Power Connector
2-pin terminal block for power input. Use aSafety Extra Low Voltage (SELV) compliant limited
power source (LPS) with either arated output power limited to ≤100 Wor arated output current
limited to ≤5A.
Audio Connector
The Axis product has the following audio connectors:
• Audio in (pink) –3.5 mm input for amono microphone, or aline-in mono signal.
• Audio out (green) –3.5 mm output for audio (line level) that can be connected to
apublic address (PA) system or an active speaker with abuilt-in amplier. Astereo
connector must be used for audio out.
For audio in, the left channel is used from astereo signal.
RS485/RS422 Connector
Two terminal blocks for RS485/RS422 serial interface used to control auxiliary equipment such as
pan-tilt devices.
SD Card Slot
NONO
NOTICETICE
TICE
•Risk of damage to SD card. Do not use sharp tools or excessive force when inserting
or removing the SD card.
•Risk of data loss. To prevent data corruption, the SD card should be unmounted before
removal. To unmount, go to Setup >System Options >Storage >SD Card and click
Unmount.
This product supports microSD/microSDHC/microSDXC cards (not included).
For SD card recommendations, see www.axis.com
Control Button
For location of the control button, see Hardware Overview on page 10.
The control button is used for:
13
Available from A1 Security Cameras

AXIS P13 Series
• Enabling the Focus Assistant. Press and very quickly release the Control button.
• Resetting the product to factory default settings. See page 20.
• Connecting to an AXIS Video Hosting System service or AXIS Internet Dynamic DNS
Service. For more information about these services, see the User Manual.
S ecications
O erating Conditions
The Axis product is intended for indoor use.
Product Temperature Humidity
AXIS P13 4 0°C to 55 °C
(32 °F to 131 °F) 10–85% RH (non-condensing)
AXIS P13 5 0°C to 55 °C
(32 °F to 131 °F) 10–85% RH (non-condensing)
Power Consum tion
NONO
NOTICETICE
TICE
Use alimited power source (LPS) with either arated output power limited to ≤100W
or arated output current limited to ≤5A.
Product Power over Et ernet (PoE) IEEE
802.3af/802.3at Type 1Class 3DC
AXIS P13 4 Max. 7. W, typical 4.3 W8–28 VDC, max. 7.4 W, typical 4.1 W
AXIS P13 5 Max. 7.9 W, typical 4.7 W8–28 VDC, max. 7.7 W, typical 4. W
Connectors
I/O Connector
4–pin terminal block
For an example diagram, see Connection Diagrams on page 17.
14
Available from A1 Security Cameras

AXIS P13 Series
Function Pin Notes Specications
0VDC (-) 10VDC
DC output 2Can be used to power auxiliary equipment.
Note: This pin can only be used as power out. 12 VDC
Max load =50 mA
Congurable
(Input or
Output)
3–
4Digital input –Connect to pin 1to activate,
or leave oating (unconnected) to deactivate. 0to max 30 VDC
Digital output –Connected to pin 1when
activated, oating (unconnected) when
deactivated. If used with an inductive load,
e.g. arelay, adiode must be connected in
parallel with the load, for protection against
voltage transients.
0to max 30 VDC, open
drain, 100 mA
Power Connector
2-pin terminal block for DC power input. Use aSafety Extra Low Voltage
(SELV) compliant limited power source (LPS) with either arated output
power limited to ≤100 Wor arated output current limited to ≤5A.
Audio Connector
3.5 mm audio
connectors (stereo)
1Tip 2Ring 3Sleeve
Audio Input Microphone/Line in Ground
Audio Output Line out (mono) Ground
15
Available from A1 Security Cameras

AXIS P13 Series
RS485/422 Connector
Two 2-pin terminal blocks for RS485/RS422 serial
interface. The serial port can be congured to support:
• Two-wire RS485 half duplex
• Four-wire RS485 full duplex
• Two-wire RS422 simplex
• Four-wire RS422 full duplex point to point
communication
Function Pin Notes
RS485B alt
RS485/422 RX(B) 1RX pair for all modes (combined RX/TX for 2-wire RS485)
RS485A alt
RS485/422 RX(A) 2
RS485/RS422 TX(B) 3TX pair for RS422 and 4-wire RS485
RS485/RS422 TX(A) 4
Important
The recommended maximum cable length is 30 m(98.4 ft).
16
Available from A1 Security Cameras

AXIS P13 Series
Connection Diagrams
I/O Connector
10 V DC (-)
2DC output 12 V, max 50 mA
AI/O congured as input
BI/O congured as output
Install the Hardware
NONO
NOTICETICE
TICE
•Due to local regulations or the environmental and electrical conditions in which the
product is to be used, ashielded network cable (STP) may be appropriate or required. Any
network cables that are routed outdoors or in demanding electrical environments shall be
shielded (STP) and intended for their specic use. Make sure that the midspan is properly
grounded. For information about regulatory requirements, see Regulatory Information 2.
Note
•Make sure that the material is strong enough to support the weight of the camera.
•For more technical specications, see the camera’s User Manual, available on
www.axis.com
17
Available from A1 Security Cameras

AXIS P13 Series
1. Prepare the wall or ceiling for installation of the stand. Use the stand as atemplate and
mark the holes before drilling.
2. Route the network cable through the wall or ceiling. Leave approximately 30 cm (11.8
in) of cable for connecting the camera.
3. If connecting an auxiliary device, for example an I/O, audio, or external power device, to
the camera, repeat the step above as applicable to the specic device.
4. Install the stand on the wall or ceiling and make sure that the screws and plugs are
appropriate for the material (e.g. wood, metal, sheet rock, stone).
5. Install the camera on the stand and tighten the tripod screw.
. Connect all cables to the camera.
7. Aim the camera in the right direction and use the supplied Allen key to tighten the
ball joint.
Access the Product
AXIS IP Utility and AXIS Camera Management are recommended methods for nding Axis products
on the network and assigning them IP addresses in Windows®. Both applications are free and can
be downloaded from www.axis.com/techsup
The product can be used with most operating systems and browsers. The recommended browsers are
• Internet Explorer®with Windows®
• Safari®with OS X®
•ChromeTM or Firefox®with other operating systems.
For more information about using the product, see the User Manual available at www.axis.com
Adjust focus
Follow these instructions to set the focus and zoom.
If the camera is mounted so that you cannot look at the image and access the lens at the same
time, use the Focus Assistant, see Adjust focus with the Focus Assistant on page 19.
1. Open the product’s home page and go to Setup >Basic Setup >Focus.
2. Under the Basic tab, click Open iris.If the button is inactive the iris is already open.
3. If focus has been set before, click Reset to reset the back focus.
4. Loosen the zoom puller and the lock screw for the focus ring on the lens by turning them
counter-clockwise. See Hardware Overview on page 10.
5. Move the zoom puller and the focus ring to set zoom and focus and check the quality of
the image in the image window.
. Re-tighten the zoom puller and the lock screw for the focus ring.
18
Available from A1 Security Cameras

AXIS P13 Series
7. On the Focus page, click Fine-tune focus automatically and wait until automatic ne
tuning is completed.
8. Click Enable iris.If the button is inactive the iris is already enabled.
9. If needed, make further adjustments under the Advanced tab. See the online help for
more information.
Adjust focus with the Focus Assistant
Note
•The view in front of the camera should not be changed during focus adjustment. If the
camera is moved, or if anger or other object is placed in front of the lens, restart the
procedure.
•If movements in front of the camera cannot be avoided, the Focus Assistant should not
be used.
•If the control button is not released within two seconds, AXIS Dynamic DNS Service
is enabled instead of the Focus Assistant.
•If the camera is mounted so that the control button cannot be accessed, you can still
use the Focus Assistant. Follow the instructions but enable the Focus Assistant before
mounting the camera.
1. Open the product’s home page and go to Setup >Basic Setup >Focus.
2. Under the Basic tab, click Open iris.If the button is inactive the iris is already open.
3. If focus has been set before, click Reset to reset the back focus.
4. Mount or place the camera so that it cannot be moved.
5. Loosen the zoom puller by turning it anti-clockwise. Move the puller to set the zoom
level. Retighten the zoom puller.
. Set the camera to its extreme distant-focus position by loosening the lock screw for the
focus ring and turning the focus ring fully clockwise.
7. Press and quickly release the control button. When the status indicator ashes, the
Focus Assistant is enabled.
8. Gently turn the focus ring anti-clockwise until it stops.
9. Turn the focus ring slowly clockwise until the status indicator ashes green.
10. To exit the Focus Assistant, press the control button. If you cannot access the control
button, the Focus Assistant is switched off automatically after 15 minutes.
11. Re-tighten the lock screw for the focus ring.
12. Open the Live View page in the web browser and check the quality of the image.
13. On the Focus page, click Fine-tune focus automatically and wait until automatic ne
tuning is completed.
14. Click Enable iris.If the button is inactive the iris is already enabled.
19
Available from A1 Security Cameras

AXIS P13 Series
15. If needed, make further adjustments under the Advanced tab. See the online help for
more information.
Reset to Factory Default Settings
Important
Reset to factory default should be used with caution. Areset to factory default will reset
all settings, including the IP address, to the factory default values.
Note
The installation and management software tools are available from the support pages
on www.axis.com/techsup
To reset the product to the factory default settings:
1. Disconnect power from the product.
2. Press and hold the control button and reconnect power. See Hardware Overview on
page 10.
3. Keep the control button pressed for 15–30 seconds until the status LED indicator ashes
amber.
4. Release the control button. The process is complete when the status LED indicator turns
green. The product has been reset to the factory default settings. If no DHCP server is
available on the network, the default IP address is 192.168.0.90
5. Using the installation and management software tools, assign an IP address, set the
password, and access the video stream.
. Refocus the product.
It is also possible to reset parameters to factory default via the web interface. Go to Setup >
System Options >Maintenance and click Default.
Further Information
For the latest version of this document, see www.axis.com
The User Manual is available at www.axis.com
Visit www.axis.com/techsup to check if there is updated rmware available for your network
product. To see the currently installed rmware version, go to Setup >About.
Visit Axis learning center www.axis.com/academy for useful trainings, webinars, tutorials and
guides.
20
Available from A1 Security Cameras
Other manuals for P13 Series
7
This manual suits for next models
2
Table of contents
Languages:
Other Axis Security Camera manuals

Axis
Axis Q60-S User manual

Axis
Axis Fixed Dome Network Camera AXIS P3301 User manual

Axis
Axis XF60-Q2901 User manual

Axis
Axis AXIS P3354 User manual

Axis
Axis 231D User manual

Axis
Axis Q60 Series User manual

Axis
Axis AXIS 213 PTZ User manual

Axis
Axis AXIS M2014-E User manual

Axis
Axis P1311 User manual

Axis
Axis P3364-VE User manual