Adjust the module arrangement to the local
conditions
Do not use silicone containing acetic acid!
SYMBOL DESCRIPTION
DIMENSIONS (see page 27)
SAFETY NOTES
Gloves should be worn during installation to prevent crushing and cutting injuries.
The product may only be used for bathing, hygienic and body cleaning purposes.
Children as well as adults with physical, mental and⁄or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The hot and cold supplies must be of equal pressures.
ELECTRICAL CONNECTION
The electrical connection may only be carried out by an electrician!
Preinstall electrcal power 230 V⁄N⁄PE⁄50 Hz (length: 0.3 m)
The current version of the applicable regulations from VDE, local authorities and
utility companies must be observed for electric installation work.
RESIDUAL CURRENT PROTECTION SYSTEM
The system must be protected via a leakage current protective device (RCD⁄ FI)
with a measurement difference current of ≤ 30 mA.
ELECTRICIAN
The installation and testing work must be performed by a skilled electrician in
observance of VDE 0100 part 701 and IEC 60364-7-701.
INSTALLATION INSTRUCTIONS
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ During installation of the product by qualified trained personnel, make sure that the
entire fastening surface is even and smooth (no protruding seams or tile offset), that
the finish of the wall is suitable to apply the product and has no weak points.
⁄ Observe all current and water lines when drilling!
⁄ The performance of the waste must be of sufficient size.
TECHNICAL DATA
Operating pressure: max. 1 MPa
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure: 1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature: max. 70°C
Recommended hot water temp.: 65°C
Connections: G1⁄2 & G3⁄4
Rate of flow by 0,3 MPa:
10750187 (1 Consumer) 44 l⁄min
10750187 (2 Consumer) 55 l⁄min
10650187 25 l⁄min
10971187 55 l⁄min
28486187 50 l⁄min
Thermal disinfection: max. 70°C ⁄ 4 min
The product is exclusively designed for drinking water!
Safety against backflow
SPARE PARTS (see page 29)
ELECTRICIAN
MAINTENANCE
The check valves must be checked regularly
according to DIN EN 1717 in accordance with
national or regional regulations (at least once
a year).
Water connection DN20
Warm water
TRANSFORMER
Water connection DN20
Cold water
CENTER SHOWER TUB
TURN ON WATER ⁄ TURN OFF
WATER
ILLUMINANT
AREA FOR REQUIRED WALL RE-
INFORCEMENT
The wall must be reinforced in this area.
AMPLIFIER FOR SPEAKER
CONNECTORS
EMPTY PIPE EN20
SAFETY GLOVES MUST BE
WORN
ELECTRICITY ON ⁄ OFF
INSTALLATION SEQUENCE
PLUG OUTLETS
Plug the unused outlet.
PIPE DECLINE
Install water pipes for body showers with a
gradient.
POTENTIAL EQUALISATION
NEUTRAL CONDUCTOR
CONDUCTOR
LIGHT SWITCH
FI PROTECTIVE SWITCH