B.Well MED-420 User manual

Instructions for Use
EN
MED-420
Electric massager with soft
heating function
Deep relaxation and
stress relief
1. INTRODUCTION
Thank you for purchasing B.Well Shiatsu massager!
Massager B.Well MED-420 is designed for a deep relaxing massage of the neck, lower back, feet, shoul-
ders, calf muscles, thighs, buttocks. The massager’s work is based on the principles of “Shiatsu” massage.
Massage by the “Shiatsu” method involves the impact on certain points on the body by alternating
pressure with the fingertips and palms.
Massager MED-420 imitates massage “Shiatsu” with 4 massage heads of different sizes, where large
and small massage heads on each side repeat the movements of the palm and the thumb. This method
of massage helps to effectively deal with stress and fatigue, relieves muscle tension, improves blood
flow, reduces heaviness and swelling. The massager will help you relax at home, you can take it along
on the road: there are 2 adapters included (for use from the mains and for use in the car). The massager
itself has a strong elastic belt for attaching to the seat back.
2. APPLICATION
Device for massage of the neck, lower back, feet, shoulders, calf muscles, thighs, buttocks
Individual use
3. MAIN BENEFITS
Massager B.Well MED-420 has 2 adapters (for use from the mains in the room and from the car). For
your better comfort, the length of the cord is increased to 2 meters. Massager B.Well MED-420 has the
function of changing the direction of movement of the massage heads (clockwise and counterclockwise).
An automatic change of direction is programmed with a frequency of 1 minute for better relieving and
kneading of trigger points.
Massager B.Well MED-420 has two speeds: fast and slow. At a fast speed there is heating and kneading.
On the slow – a deep muscle workout and relaxation. Massager B.Well MED-420 is equipped with a
soft heating function, which is necessary for deep muscle workout, activation of nerve endings and the
release of humoral factors that have a beneficial effect on the human body.
The recommended time for massage* at home is 15 minutes. A professional massage program is
designed for this time. Follow the instructions developed by B.Well specialists. MED-420 will turn itself
off at the end of the procedure , so that the effect on the body is beneficial and safe.
We recommend to refer to the scheme of the manual. The massage scheme and time are recommended
by B.Well specialists.
4. PRODUCT, ACCESSORIES
Front side Back side
1
2 3
45
6
7
8 9
1main body 6zipper
2switch on/off, changing the rotation of massage heads button 7power connector
3speed changing and heating button 8mains adapter
4massage heads 9car adapter
5belt for fixing the device in the car
5. INSTRUCTIONS FOR USE
Connect the massager to a power source.
Press the button to start the massage session.
The button adjusts the direction of movement of the massage heads.
Press the button to change the direction of the heads.
The button for the main massage allows you to adjust the speed of the massage heads,
turn on and off the heating function for the main massage procedure.
Sequentially press the button to change the speed of rotation of the massage heads
and turn on / off the heating function.
* We recommend to do a massage in clothes
Press the button to pause the massage session.
Disconnect the massager from the power source after use.
6. CONTROL SCHEME, RECOMMENDED MASSAGE AREAS
Massager MED-420 has 2 buttons with cyclic switching of functions:
1“Preparation for massage” button
а“ON/OFF” function. Turns on at fast speed with heating.
bFunction of changing direction of massage heads
2“Basic massage” button
cSpeed change function
dHeating function (illuminated by warm light).
Sequentially pressed: fast speed without heating, slow speed without heating, slow speed with
heating, fast speed with heating
a
b
c
d
1 2
We recommend to do a massage, focusing on the following images:
neck and shoulder massage
lower back and buttock massage
thighs and calf muscle massage
feet massage
Methodical recommendation for effective massage
The massage effect on the body is a complex physiological process in which mechanical, humoral and
neuro-reflex factors are involved. As a result, occurs not only mechanical kneading of the muscles, but
the improvement of lymph and blood circulation, increases the outflow of excess interstitial fluid and
decreases the swelling. Biologically active substances (histamine, acetylcholine) enter the blood, that
leads to an improvement in well-being and an increase in tone and vitality.
The first stage. Carrying out preparatory activities before the main massage procedure.
1. Turn on button 1.
2. Perform a preparatory massage session for 3 minutes.
The massage heads move clockwise, then counterclockwise, then clockwise again. After 3 minutes, turn
on button 2for the main massage.
The main stage of the massage “Shiatsu”
Pressing button 2activates massage heads at fast speed. Do massage in this mode for 2 minutes. The
massage heads will automatically move in one direction, then in the other direction, working out the
muscles and preparing the body to tonic effect by neuroreflex mechanism.
Press button 2again to activate the massage heads at slow speed. Within 3 minutes, massage by
rotating the massage heads in one direction and the other. At this stage, there will be additional stimula-
tion of nerve endings that are in the skin, tendons, ligaments, fascia, muscles, which will manifest itself
in the form of an improvement in the functioning of various organs and systems. At this stage, there is a
feeling of calm, stress will decrease.
The third press of button 2will start the heating mode when the massage heads rotate at a slow
speed. Spend a session of 3 minutes in this mode. It will allow biologically active substances (histamine,
acetylcholine) to enter the bloodstream. You will feel a general improvement in well-being. The tone of
the body will increase, the mood will improve.
The fourth press of button 2will start the heating mode with the rapid rotation of the massage heads.
At this stage, will again take place work with muscles. Problem areas will be worked out, discomfort in
painful areas will decrease. The massage time in this mode is 2 minutes.
Pressing button 2for the fifth time will turn off the heating. This is the final stage of the massage,
aimed at relaxation and calmness. The massage heads will run at fast speed back and forth for 2 min-
utes. At the end of this time, the massager will turn off automatically. The session is over! Don’t rush to
get up right away. Wait a little in a relaxed state, feel the healing power of Shiatsu massage.
7. CONTRAINDICATIONS AND PRECAUTIONS
ATTENTION! If the following symptoms apply to you, please consult a specialist
before using the massager:
In the case of pregnancy or recent birth, physical injury, heart or pacemaker disease, diabetes or
other sensitivity disorders, phlebitis and/or thrombosis, joint dysfunction, inflammation or injury,
osteoporosis, high temperature, Vertebral or spinal deformities, increased risk of clotting, pins/
screws/artificial joints or other medical devices implanted in the body.
Precautions:
1. Use the device only for the intended purpose specified in this manual.
2. Do not use the device under the blanket or under the cushion. This can lead to fire.
3. Do not sit on massage massage heads.
4. Do not fall asleep during the procedure.
5. Avoid water hitting the massager, power plug, power cord.
Immediately disconnect the device from the power supply if it was in the water.
6. Disconnect the power cord if you do not use a massager.
7. Do not use damaged power cord or plug.
8. Do not spray essential oil, paint or pesticides.
9. Do not use in wet places such as bathrooms.
10. Do not leave the massager under direct sunlight.
11. Do not open the case and do not replace the internal parts.
12. Do not place near fire and combustible materials.
13. Keep out of reach of children.
8. CLEANING AND STORAGE
ATTENTION! Before you start cleaning, you must disconnect the device from the power
and wait for the complete cooling.
If the product is contaminated, wipe it with a soft, slightly damp cloth on the outside or use a dry
cloth;
Store the massager in a dry, cool place, do not expose directly to sunlight;
Do not use sprays, gasoline, solvents to clean the massager.

9. TROUBLESHOOTING AND SOLUTIONS
NOTE, in the event of a malfunction, it is necessary to disconnect the massager from
electricity and let it cool for 60 minutes.
Possible problems Cause, troubleshooting
Does not turn on
Make sure the massager is plugged in
Connect the appliance to a different power socket
Turn off the massager, repeat the procedure after
10 minutes
Sudden stop during the massage session
Power turned off accidentally
The massager has a 15 minute automatic timer, the time
limit has been reached
10. TECHNICAL SPECIFICATIONS
Name: Electric massager with soft heating function
Model: MED-420
Power (W): 24W
Electrical parameters: 100-240 V (AC), 50/60 Hz, 0.6 A (max); direct current
12V(DC), 2.0 A
Number of massage heads: 4
Direction of rotation of massage heads: clockwise and counterclockwise
Number of speeds: 2
Heating function: Yes, 38-42
°C
Autoswitch off: Yes, in 15 minutes
Package size: 32 × 10,5 × 20 cm
Weight in package: 1.4 kg
Number of adapters: 2 (from mains – 200 cm length; from car –
length 185 cm (including adapter))
Protection against electric shock: Class II
Degree of protection against electric shock
(leakage currents): Type B
Set:
Massager – 1 pc.
Mains adapter – 1 pc.
Car adapter – 1 pc.
Instruction manual with warranty card – 1 pc.
11. NOTES
The massager has a heating function, note if there is an increased sensitivity to heat.
Children should use this massager under the supervision of their parents.
Immediately stop the session and consult a doctor if severe redness appears on the skin.
If you feel any discomfort during use, stop using the massager immediately and consult with a
doctor.
After use, turn off the switch, disconnect the power plug.
We recommend drinking 500 ml of water or hot tea after the massage to accelerate the body’s
metabolism.
If the power cord is damaged, you should contact the maintenance department for replacement or
purchase from the manufacturer.
12.COMPLIANCE WITH STANDARDS
The submitted sample of the above equipment fulfil the requirements of following directives:
Low Voltage Directive 2014/35/EU
Electromagnetic Compatibility Directive 2014/30/EU
13.DISPOSAL
Products should be disposed of according to accepted standards and should not be disposed of together with
household waste.
The production date – the first four digits of the serial number of the device – is indicated on the war-
ranty card and the box.
The first and second digits are the week number, the third and fourth are the year of production.
14. GUARANTEE OBLIGATIONS
Warranty period for the massager is 2 years.
The policy of the company B.Well provides constant improvement of products. Therefore, the company
reserves the right to make complete or partial changes to the products without prior notice and in
accordance with production requirements.
15. WARRANTY
Serial number (SN):
Date of sale:
Seller’s signature:
Seal of seller’s company:
16. DESCRIPTION OF THE SYMBOLS USED ON THE PACKAGE
REFER TO THE INSTRUCTION
MANUAL BEFORE USE
45
0 OPERATING CONDITION,
TEMPERATURE 0 to 45 °С
MANUFACTURER’S
NAME
CE MARK -15
55 STORAGE CONDITION,
TEMPERATURE -15 to 55 °С ARTICLE NUMBER
RoHS MARK USE INDOORS SERIAL NUMBER
RECYCABLE
CLASS OF PROTECTION
AGAINST ELECTRIC SHOCK
(CLASS II)
KEEP DRY
DISPOSAL FOR SEPARATE
COLLECTION POLARITY OF D.C. POWER CONNECTOR
Last revision 2023-W17
Electric massager B.Well MED-420
DEVICE IS NOT A MEDICAL PRODUCT
B.Well Swiss AG, Bahnhofstrasse 24,
9443 Widnau, Switzerland • www.bwell-swiss.ch
IM_MED-420_EN_for_A4_1723_SN
Other B.Well Massager manuals