manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bacharach
  6. •
  7. Measuring Instrument
  8. •
  9. Bacharach 0012-9015 User manual

Bacharach 0012-9015 User manual

Other Bacharach Measuring Instrument manuals

Bacharach Neutronics 5100E User manual

Bacharach

Bacharach Neutronics 5100E User manual

Bacharach 300 User manual

Bacharach

Bacharach 300 User manual

Bacharach HGM300 Guide

Bacharach

Bacharach HGM300 Guide

Bacharach 0024-8555 User manual

Bacharach

Bacharach 0024-8555 User manual

Bacharach MGC100 Operation manual

Bacharach

Bacharach MGC100 Operation manual

Bacharach HGM300 Guide

Bacharach

Bacharach HGM300 Guide

Bacharach 3010 Operation manual

Bacharach

Bacharach 3010 Operation manual

Bacharach Gas Pup User manual

Bacharach

Bacharach Gas Pup User manual

Bacharach PUR-CHEK PRO User manual

Bacharach

Bacharach PUR-CHEK PRO User manual

Bacharach SF6 Portable Monitor User manual

Bacharach

Bacharach SF6 Portable Monitor User manual

Bacharach LS-20B User manual

Bacharach

Bacharach LS-20B User manual

Bacharach PCA 2 Parts list manual

Bacharach

Bacharach PCA 2 Parts list manual

Bacharach Monoxor II User manual

Bacharach

Bacharach Monoxor II User manual

Bacharach Ultra MAC 2000 Series Installer manual

Bacharach

Bacharach Ultra MAC 2000 Series Installer manual

Bacharach 11-9026 User manual

Bacharach

Bacharach 11-9026 User manual

Bacharach Draftrite User manual

Bacharach

Bacharach Draftrite User manual

Bacharach Neutronics 5124BE-N1-WO User manual

Bacharach

Bacharach Neutronics 5124BE-N1-WO User manual

Bacharach Leakator Jr. User manual

Bacharach

Bacharach Leakator Jr. User manual

Bacharach Tru Pointe Operating manual

Bacharach

Bacharach Tru Pointe Operating manual

Bacharach Monoxor Plus User manual

Bacharach

Bacharach Monoxor Plus User manual

Bacharach MGS-250 User manual

Bacharach

Bacharach MGS-250 User manual

Bacharach Fyrite INSIGHT PLUS User manual

Bacharach

Bacharach Fyrite INSIGHT PLUS User manual

Bacharach CO2 Analyzer 3150 Instruction Manual

Bacharach

Bacharach CO2 Analyzer 3150 Instruction Manual

Bacharach Fyrite Tech 50 Operation and maintenance manual

Bacharach

Bacharach Fyrite Tech 50 Operation and maintenance manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SLING PSYCHROMETER
Configuration Operation Maintenance
Part Number: 0012-9015
November 2017, Rev. 7
For Use with Spirit Thermometers
P/N 0012-7012 (30° to 110° F, Red Spirit)
P/N 0012-7043 (–5° to 50° C, Blue Spirit)
Discontinued Mercury Thermometers
P/N 0012-7011 (30° to 110° F, Mercury)
P/N 0012-7013 (–5° to 50° C, Mercury)
CAUTION: Damage to thermometers or
plastic case will result if instrument is
exposed to direct sunlight or excessive
heat for prolonged periods.
WARRANTY
Bacharach, Inc. warrants to Buyer that at the time of delivery this Product will be free from defects in material
and manufacture and will conform substantially to Bacharach Inc.’s applicable specifications. Bacharach’s
liability and Buyer’s remedy under this warranty are limited to the repair or replacement, at Bacharach’s option,
of this Product or parts thereof returned to Seller at the factory of manufacture and shown to Bacharach Inc.’s
reasonable satisfaction to have been defective; provided that written notice of the defect shall have been given
by Buyer to Bacharach Inc. within one (1) year after the date of delivery of this Product by Bacharach, Inc. For
full details concerning this warranty, contact Bacharach Inc.
Product Leadership Training Service Reliability
Sling Psychrometer
2 0012-9015 Rev 7
Overview
1. Remove cap (B)
then immerse
end of body to
saturate wick
(A).
A. Wick
B. End cap
C. Psychrometer body
D. Wet bulb thermometer
E. Tube
F. Dry bulb thermometer
G. Screws
H. Thermometer clips
I. Roll pin
2. Fill
psychrometer
reservoir with
water. Replace
cap (B).
3. Be sure wick
covers “wet”
bulb. The
other bulb is
dry.
4. Pull body (C)
from tube (E)
until body
hangs free.
5. Use tube
(E) as
handle;
whirl body
(C) about
1-½
minutes.
6. Read wet and dry bulb thermometers;
replace body in tube.
7. Set thermometer readings on upper
two calculator scales.
8. Read % relative humidity as indicated
by arrow.
Sling Psychrometer
0012-9015 Rev 7 3
Operation
1. To ensure WICK (A) is saturated with water and covers spirit reservoir on WET BULB
THERMOMETER (D), remove END CAP (B) and immerse PSYCHROMETER BODY (C) up
to the thermometer reservoirs until WICK is thoroughly wetted.
2. Fill END CAP with water and replace; tighten just enough to prevent leakage. Be sure
reservoir on other THERMOMETER (F) is dry.
3. Pull TUBE (E) clear of BODY so BODY can swivel.
4. Holding TUBE, whirl body two to three revolutions per second (120 to 180 RPM).
5. Continue whirling until temperatures stabilize (1-½ minutes is usually ample).
6. Immediately read WET BULB THERMOMETER (D) and then DRY BULB THERMOMETER
(F). (See application instructions.)
7. Set wet and dry bulb temperatures opposite each other on side rule type calculator
scales, sliding BODY into TUBE as required.
8. Read % R.H. (percent relative humidity) indicated by arrowhead on lower scale.
Application
Wet-bulb temperatures should be read first and as quickly as possible for highest
accuracy. Delay in reading may cause error. In addition, the wick must be kept clean,
saturated with water, and whirled long enough to stabilize temperatures.
The range of the psychrometer is from 10% to 100% R.H., for dry-bulb temperatures of
30° to 100°F (–5° to 50°C).
In addition to the above instructions, barometric pressure and other factors will influence
exact relative humidity determinations to a very minor degree. For precise work, use a
psychrometric chart or set of tables such as W.B. No. 235 “Psychrometric Tables for
Obtaining the Vapor Pressure, Relative Humidity, and Temperature of Dew Point,” which
can be purchased from the Superintendent of Documents, United States Government
Printing Office, Washington, D.C. The accuracy of the Psychrometer, however, is
satisfactory for all except the most exacting work.
Maintenance
WICK (A) should be kept clean. When dirty, cut off WICK below WET BULB THERMOMETER
(D) and pull clean section out of END CAP (B) and slide over bulb on WET BULB
THERMOMETER.
A WICK REPLACEMENT KIT may be purchased separately (refer to parts list). One or two
extra WICKS may be kept in END CAP and will help retain moisture longer. Pack WICKS
loosely to allow thorough water saturation and ample water supply to the WET BULB
THERMOMETER.
THERMOMETERS (D) and (F) are replaceable by backing off SCREWS (G) and loosening
THERMOMETER CLIPS (H). To separate BODY (C) and TUBE (E), drive ROLL PIN (I) out of
eye in PLUG AND SWIVEL ASSEMBLY, which then may be slid out back end of TUBE.
Sling Psychrometer
4 0012-9015 Rev 7
Parts and Accessories
Part
Number
Description
Qty per Assembly 0012-xxxx
7011
7012
7013
7043
0012-0180
Plug and Swivel Assembly
1
1
1
1
0012-0176
Thermometer Clip
2
2
2
2
0012-0007
Wick
1
1
1
1
0002-1740
Screw
2
2
2
2
0002-6858
Roll Pin
1
1
1
1
0006-5456
Cap
1
1
1
1
0012-0012
Friction Ring
2
2
2
2
0012-0194
Body (°F)
1
1
-
-
0012-0018
Body (°C)
-
-
1
1
0012-0006
Tube (°F)
1
1
-
-
0012-0019
Tube (°C)
-
-
1
1
0012-0266
Thermometer, 30 to 110°F, Red Spirit
2
2
-
-
0012-0327
Thermometer, –5 to 50°C, Blue Spirit
-
-
2
2
Part
Number
Description
Qty
0012-0011
Wick Replacement Kit containing
4 Wicks
Bacharach, Inc.
621 Hunt Valley Circle
New Kensington, PA 15068 USA
Pittsburgh, PA USA | Dublin, IRE | Gloucester, UK | Stanardsville, VA USA | Toronto, CAN
mybacharach.com | help@mybacharach.com