2
SCOPE OF THIS MANUAL
This manual contains information concerning the installation, opera-
tion and maintenance of Badger’s Magnetoflow®electromagnetic flow
meter models with Primo®Amplifier.
To ensure proper meter performance, the instructions given in this
manual should be thoroughly understood. Keep a copy of this manual
in a readily accessible location for future reference.
TABLE OF CONTENTS
System Description ........................................................................ 2
Unpacking and Inspection ............................................................. 2
Transportation and Handling ......................................................... 2
Meter Installation ............................................................................ 3
Specifications - Detector ............................................................... 5
Grounding ....................................................................................... 6
Specifications - Amplifier ................................................................ 6
Wiring .............................................................................................. 7
Programming ................................................................................... 9
Unit of Measure .......................................................................... 9
Full Scale Setting (Maximum Flow) ......................................... 10
Low Flow Cutoff ........................................................................ 10
Empty Pipe Detection ............................................................... 11
Flow Direction ........................................................................... 11
Filter Dampening ...................................................................... 12
Error List (Messages) .............................................................. 12
Resetting of Totalizers ............................................................. 12
Analog Outputs ......................................................................... 13
Pulse Outputs ........................................................................... 14
Wiring of AMR unit to Mag ....................................................... 14
Frequency Output .................................................................... 15
Flow Alarms .............................................................................. 15
Detector Factor Field Calibration ............................................ 15
Accuracy Test .......................................................................... 16
Meter/Pipe Size ........................................................................ 16
Password Protection ................................................................ 16
Language Selection ...................................................................... 16
Troubleshooting ............................................................................ 17
Error Message Explanation ......................................................... 18
Board Assembly Replacement .................................................... 19
Fuse Replacement ....................................................................... 19
SYSTEM DESCRIPTION
Magnetoflow®electromagnetic flow meters are intended for fluid
metering in most industries including water, wastewater, food and
beverage, pharmaceutical and chemical.
The basic components of an electromagnetic flow meter are two: 1)
The Detector; which includes the flow tube, isolating liner and
measuring electrodes, and 2) the Amplifier, which is the electronic
device responsible for the signal processing, flow calculation, display
and output signals.
Primo
®
Amplifie
Detector
®
The materials of construction of the wetted parts (liner and elec-
trodes) should be appropriate for the specifications on the intended
type of service. Review of the compatibilities consistent with the
specifications is recommended.
All Badger’s Magnetoflow mag flow meters are factory tested and
calibrated. A calibration certificate is included in the shipment of each
meter.
UNPACKING AND INSPECTION
Magnetoflow mag flowmeters are shipped in special shipping con-
tainers. Upon receipt of the meter, perform the following unpacking
and inspection procedures. If damage to the shipping container is
evident, be present when the meter is unpacked.
A) Carefully open the shipping container following any instruc-
tions that may be marked on the exterior. Remove all
cushioning material surrounding the meter.
B) Carefully lift the meter from the container.
C) Retain the shipping box and all packing materials for possible
use in reshipment or storage.
D) Visually inspect the meter for any physical damage such as
scratches, loose or broken parts, or any other sign of damage
that may have occurred during shipment.
NOTE: If damage is found, request an inspection report by
the carrier’s agent within 48 hours of delivery. Then file a
claim with the carrier. A formal claim for equipment
damaged in transit is the responsibility of the customer.
E) Verify that the meter received is consistent with the product
ordered. The detail on the product labels on the detector and
the amplifier should help this verification.
F) All detectors with PTFE liner are shipped from the factory with
a liner protector. This protector maintains the proper form of the
PTFE material and protects it during shipping and storage. Do
not remove this protector until you are ready to install the unit.
G) Storage: If the meter is not to be immediately installed, store
it in its original container in a dry, sheltered location. Storage
temperature: -4 to 158 °F (-20 to 70 °C)
METER INSTALLATION
METER LOCATION GUIDELINES
The following are several guidelines for determination of a good
location for meter installation:
Temperature Ranges
In order to prevent damage to the meter, the maximum temperature
ranges must be observed.
Primo®Amplifier
Ambient temperature: -4 to 140°F (-20 up to +60°C)
Meter with Meter Mount Primo
Fluid temperature: PTFE/PFA, -40 to 212°F (-40 up to +100°C)
Outdoor Installations - Primo Amplifier
The Primo Amplifier can be installed outdoors but with a few
requirements:
1. The ambient environment must not be out of the temperature
ratings for the unit. (-4 to 140 degrees F)
2. The Primo must be protected to some degree from the outside
elements. At a minimum, a roof or shield of sorts should be
fabricated over the unit to protect the LCD display from the
sunlight. It will also keep the unit out of the possibility of a hard
sustained rain which could cause moisture to get into the unit. An
alternative approach would be to simply mount the unit in a
“Hoffman style” outdoor enclosure, eliminating the potential of
either issue arising.
If an indoor environment is within 250 feet of the Mag meter
installation, consideration should be given to increase the cable