manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bante Instruments
  6. •
  7. Analytical Instrument
  8. •
  9. Bante Instruments MS400C User manual

Bante Instruments MS400C User manual

Other Bante Instruments Analytical Instrument manuals

Bante Instruments D0scan10 User manual

Bante Instruments

Bante Instruments D0scan10 User manual

Bante Instruments MS200 User manual

Bante Instruments

Bante Instruments MS200 User manual

Popular Analytical Instrument manuals by other brands

Fieldmann FDLM 1050 user manual

Fieldmann

Fieldmann FDLM 1050 user manual

Dewetron DEWE-30-16 Technical reference manual

Dewetron

Dewetron DEWE-30-16 Technical reference manual

Cocraft NLT04 Original instructions

Cocraft

Cocraft NLT04 Original instructions

EXTOL PREMIUM 8820043 Translation of the original user manual

EXTOL PREMIUM

EXTOL PREMIUM 8820043 Translation of the original user manual

M&C GENTWO PMA1000 instruction manual

M&C

M&C GENTWO PMA1000 instruction manual

MICRO-EPSILON optoncdt 1700 instruction manual

MICRO-EPSILON

MICRO-EPSILON optoncdt 1700 instruction manual

RIDGID SeeSnake Compact quick start guide

RIDGID

RIDGID SeeSnake Compact quick start guide

CONDTROL XP4 PRO user manual

CONDTROL

CONDTROL XP4 PRO user manual

Extech Instruments BR200 user manual

Extech Instruments

Extech Instruments BR200 user manual

Teledyne 3000PA operating instructions

Teledyne

Teledyne 3000PA operating instructions

Olympus IPLEX FX Series instructions

Olympus

Olympus IPLEX FX Series instructions

Bosch GLM 50 C Professional Original instructions

Bosch

Bosch GLM 50 C Professional Original instructions

Reflecta DigiEndoscope instruction manual

Reflecta

Reflecta DigiEndoscope instruction manual

Chinavision CVACZ-G696 Use manual

Chinavision

Chinavision CVACZ-G696 Use manual

Fuji Electric ZKMA instruction manual

Fuji Electric

Fuji Electric ZKMA instruction manual

Teledyne 3300TA operating instructions

Teledyne

Teledyne 3300TA operating instructions

RIDGID micro CA-25 Operator's manual

RIDGID

RIDGID micro CA-25 Operator's manual

Würth MASTERVISION MINI REC operating instructions

Würth

Würth MASTERVISION MINI REC operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

MS400C Hotplate Magnetic Stirrer
USER MANUAL
Bante Instruments Inc.
1 IMS400C
Introduction
Thank you for selecting the MS400C hotplate magnetic stirrer. This
manual provides a step-by-step guide to help you operate this stirrer.
Please carefully read the following instructions before use.
Environmental Conditions
Before unpacking, ensure that current environmental conditions meet
the following requirements.
•Relative humidity is less than 80%
•Ambient temperature between 0° C (32° F) and 40° C (104°F)
•No corrosive gas exists and well-ventilated area
Packing List
The following list describes all components of the stirrer. If any items
are missing or damaged, contact the supplier immediately.
•Magnetic stirrer • Stir bar
•Temperature probe
Stirrer Overview
Keypad
Key
Function
Time
Set the stirring time
° C
Set the heating temperature
Enter
Confirm the settings
Exit
Exit the setting, heating or timed stirring mode

Increase value or stirring speed

Decrease value or stirring speed
Connectors
1 Socket for temperature probe
2 Power switch
3 Fuse
Safety Notes
•Before connecting the power supply, ensure that the local mains
power voltage meets the requirements of the stirrer and that the
power outlet is properly grounded.
•Ensure that the cable of the temperature probe and power cord are
kept clear of the hot plate.
•Do not use a metal container.
•Do not heat or stir volatile or flammable liquids.
Stirring
1. Place stir bar into the container and fill the liquids to be stirred.
2. Place container in the center of the top plate.
3. Press the power switch to ON position.
4. Press the or key, the stir bar will begin to rotate after 5
seconds, the display will show the stirring speed.
MS400C I2
5. When desired stirring is completed, press the power switch to OFF
position. Remove container from the top plate.
•If you need to stir a high viscosity liquid, we recommend to set a
slower stirring speed.
•If the stir bar is not running smoothly, try moving the container
slightly, the stir bar should be in the center of the container.
Stirring Time
The MS400C magnetic stirrer has a built-in clock chip, which allows for
time management during stirring and heating.
1. Press the Time key, the display shows 000 min.
2. Press the / key to set a desired stirring time.
3. Press the Enter key, the timer begins countdown until it reaches
zero, the stirrer will stop running.
To exit the setup without saving changes, press the Exit key.
Heating
1. Insert the plug of the temperature probe into the jack socket on the
rear panel of stirrer.
2. Place the temperature probe into the liquid.
3. Press the ° C key, the display shows 000°C.
4. Press the / key to set a desired temperature.
5. Press the Enter key to begin the heating.
•The hot plate will not heat if the temperature probe is not attached.
•While heating a liquid, the temperature probe must be immersed.
Otherwise, the hot plate will heat continuously and will go into a
fault condition.
•During the heating process, the Heating icon will show in sequence
as follows:
•When the liquid reached the target temperature, the Heating icon
will continuously flash.
•Press the ° C key, then press the Exit key, the hot plate will stop
working.
Temperature Calibration
During the heating, if the temperature reading displayed differs from
that of an accurate thermometer, please follow the steps below to
calibrate the temperature probe.
1. Turn off the stirrer.
2. Press and hold the and keys for 5 seconds, then turn on the
stirrer.
3. Press the / key to modify the temperature value.
4. Press the Enter key to save.
3 IMS400C
Appendix
Optional Accessories
Order Code
Description
TP-100P
Temperature probe, stainless steel body
STB-S
Stir bar, PTFE material, 30 (L) ×7(Ø ) mm
Specifications
Model
MS400C
Stirring Volume
0 to 2000 ml
Stirring Speed
0 to 2500 rpm
Heater
300 W
Hot plate Temperature
300° C
Timer Range
0 to 999 minutes
Top Plate Size
135 (L) ×135 (W) mm (5.3 ×5.3 in.)
Top Plate Material
Ceramic coating
Display
Segmented LCD, 95×35 mm (3.74×1.37 in.)
Power Requirements
AC 220V/50Hz
Dimensions
230 (L)×180 (W) ×120 (H) mm (9 ×7×4.7 in.)
Weight
2.2 kg (4.8 lb)
Troubleshooting
Fault
Cause and Corrective Action
Stir bar is not running
The screw under the top plate is loose.
Hot plate is not heating
Temperature probe is not connected to the
stirrer or the heater has damaged.
Office: 4715 Castlewood St., Sugar land, TX 77479, USA
Tel: (+1) 346-762-7358
E-mail: [email protected]
Factory: F3, Building 2, No.2185, Laifang Rd., Shanghai 201615, China
Tel: (+86) 21-6404-1598
E-mail: banteinstrument@hotmail.com
www.bante-china.com
Disposal
This product is required to comply with the European Union’s Waste
Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC and
may not be disposed of in domestic waste. Please dispose of this
product in accordance with local regulations at the collecting point
specified for electrical and electronic equipment.
Warranty
The warranty period for stirrer is one year from the date of shipment.
Above warranty does not cover the stir bar. Out of warranty products
will be repaired on a charged basis.
The warranty on your stirrer shall not apply to defects resulting from:
•Improper or inadequate maintenance by customer.
•Unauthorized modification or misuse.
•Operation outside of the environment specifications of the
products.
For more information, please contact the supplier.
The information in this document is subject to change without notice.
Copyright © Bante Instruments Inc, 2022. All rights reserved.