manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BARRON
  6. •
  7. Safety Equipment
  8. •
  9. BARRON Exitronix LED-90 Series User manual

BARRON Exitronix LED-90 Series User manual

IMPORTANT SAFEGUARDS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
When using electrical equipment, basic safety precautions should always be followed including the following:
• DISCONNECT AC POWER SUPPLY BEFORE SERVICING.
• Installation and servicing of this equipment should be performed by qualified service personnel only.
• Ensure that the electrical wiring conforms to the National Electrical Code NEC® and local regulations,
if applicable.
• Do not mount near gas or electrical heaters.
• Do not use outdoors.
• Equipment should be mounted in locations and at heights where it will not be readily subjected to tampering
by unauthorized personnel.
• The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
• Any modification or use of non-original components will void the warranty and product liability.
• Do not use this equipment for other than intended use.
• Allow battery to charge for 24 hours before first use.
SAVE THESE INSTRUCTIONS!
Technical Support ■ (623) 580-8943 ■ [email protected]
LED-90 Series
Installation Instructions
10070145 REV 2 - 08/2020 1800-533-3948 www.barronltg.com
Wall/Ceiling Mount - Back Power Feed
1. Insert a flat screwdriver underneath both of the locking tabs on the
bottom of the fixture to loosen and separate the enclosure from
the backplate. (Fig. 1)
2. Punch out the center knockout and any desired knockouts for
mounting to the J-box located in the backplate.
3. Route wires out through the center hole of the backplate.
4. Make electrical connections; see Electrical Connections section.
5. Secure the backplate to the J-box using appropriate hardware
(provided by others).
6. Connect the battery to the PCB. (Fig. 2)
7. Snap the front cover back onto the backplate.
Wall/Ceiling Mount - Top Power Feed
1. Insert a flat screwdriver underneath both of the locking tabs on the
bottom of the fixture to loosen and separate the enclosure from
the backplate. (Fig. 1)
2. Punch out the conduit entry knockout from the top flange and any
desired knockouts for securing to the mounting surface located in
the backplate.
3. Secure the backplate to the mounting surface using appropriate hardware (provided
by others).
4. Secure flexible conduit (not provided) to the access hole and route wires through the
conduit to the J-box.
5. Make electrical connections; see Electrical Connections section.
6. Connect the battery to the PCB. (Fig. 2)
7. Punch out the conduit entry knockout from the top of the enclosure.
8. Snap the front cover back onto the backplate.
Fig. 1 Conduit Entry
Knockout
Backplate
Power
Connector
Locking Tabs
Fig. 2
Battery
Connector
Conduit Entry
Knockout
Use Flexible Conduit Only.
LED-90 Series
Installation Instructions
10070145 REV 2 - 08/2020 2800-533-3948 www.barronltg.com
Electrical Connections
All electrical connections should be made inside the
J-box. Make electrical connection as follows:
120VAC 277VAC
White - Common White - Common
Black - 120VAC Orange - 277VAC
Green - Ground Green - Ground
Note: Cap unused leads to prevent shorting.
Remote Lamp Connection - 3.6V, 3W Max
(Option)
If the fixture is equipped with remote capability,
remove the jumper from the remote wire coming from
the PCB and replace it with the remote wire adapter
(included). All electrical connections should be made
inside the J-box. Make remote connections as
follows:
Yellow - Positive (+)
White - Negative (-)
LED
Indicator
Battery
PCB
Test
Button
Lamp
Red (277VAC)
Black (120VAC)
White (Com)
Backplate
Power
Connector
Lamp
Remote Connector
(If Equipped)
Yellow (+)
White (-)
Red (+)
Black (-)
LED-90 Series
Installation Instructions
10070145 REV 2 - 08/2020 3 800-533-3948 www.barronltg.com
Self-Test/Self-Diagnostics (G2)
Operation
The purpose of this option is to provide Self-testing and Self-diagnostic capabilities to the emergency unit. At predetermined
intervals, the emergency unit will automatically switch into battery mode. Refer to the Self-Test Feature section below for
timing details. The emergency unit will also perform various Self-diagnostic tests to determine if there are any faults. Visual
signaling will alert maintenance personnel to a fault of the emergency unit electronics, battery, and/or battery charger. The
circuitry continuously monitors the operating condition of the emergency unit and battery charging circuit/battery supply
voltage. Refer to the LED Indicator section below for fault reporting details.
Self-Test Feature
• The emergency unit will automatically switch to battery mode every 30 days for a period of 30 seconds.
• The emergency unit will automatically switch to battery mode every 180 days for a period of 30 minutes.
• The emergency unit will automatically switch to battery mode every 365 days for a period of 90 minutes.
LED Indicator
Once the unit is properly installed according to the installation instruction sheet and AC power is supplied, the unit will turn on
and the Self-diagnostic test function will initiate. After this, the bi-color LED will indicate the status of the unit.
• A steady green LED indicates that normal AC power is being supplied to the emergency unit and the battery is charged.
• A blinking green LED indicates that the unit is in battery mode. Refer to the Test Button Feature section below for
manual test details.
• A red/green flashing LED indicates that the battery is charding.
• A red LED indicates whenever the Self-diagnostic system has detected a fault condition. Refer to the chart below to
determine the fault condition:
Test Button Feature
MANUAL TEST – Pressing the test button will switch the unit into battery mode for a set amount of time. The desired length
of the test is determined by the number of times the test button is pressed.
• Pressing the test button once will switch the unit into battery mode for a period of 30 seconds. The LED indicator will
continuously blink green 1 time during this period.
• Pressing the test button twice within 2 seconds will switch the unit into battery mode for a period of 30 minutes. The
LED indicator will continuously blink green 2 time during this period.
• Pressing the test button 3 times within 2 seconds will switch the unit into battery mode for a period of 90 minutes. The
LED indicator will continuously blink green 3 time during this period.
RESET – Pressing and holding the test button for 3 seconds will cancel a test. Pressing and holding the test button for 6
seconds will reset the LED to a steady green. If multiple faults are present, it may be necessary to repeat this procedure for
each remaining fault indicated by the blinking red LED.
Use in accordance with local building codes.
Red LED Indication
Steady Red
Blinking 1 Time
Blinking 2 Times
Blinking 3 Times
Blinking 4 Times
Blinking 5 Times
Unit Fault
Battery is Disconnected
Electronics Failure
Battery Failure
N/A
Emergency Lamp
Remote Lamp (If Equipped)
Corrective Action
Check Battery Connection
Check Battery Then Consult Factory
Check Battery Then Consult Factory
N/A
Check Lamp Connections Then Consult Factory
Check Remote Lamp Connections Then Consult Factory
LED-90 Series
Installation Instructions
10070145 REV 2 - 08/2020 4800-533-3948 www.barronltg.com

Other BARRON Safety Equipment manuals

BARRON Exitronix 900E Series User manual

BARRON

BARRON Exitronix 900E Series User manual

BARRON EXITRONIX VEX-S Series User manual

BARRON

BARRON EXITRONIX VEX-S Series User manual

BARRON Exitronix CH900X Series User manual

BARRON

BARRON Exitronix CH900X Series User manual

Popular Safety Equipment manuals by other brands

mcmurdo CREWFIT 180N PRO Fitting instructions

mcmurdo

mcmurdo CREWFIT 180N PRO Fitting instructions

PDS WorkSafe AZ 700 Series instruction manual

PDS

PDS WorkSafe AZ 700 Series instruction manual

Klein Tools KONSTRUCT 60447 instructions

Klein Tools

Klein Tools KONSTRUCT 60447 instructions

SDKELI LCSII Operation manual

SDKELI

SDKELI LCSII Operation manual

ABS ABS-Lock DH04-BS manual

ABS

ABS ABS-Lock DH04-BS manual

WaterWarden SmartPool Pool Safety Net Installation & maintenance manual

WaterWarden

WaterWarden SmartPool Pool Safety Net Installation & maintenance manual

Essex Electronics EPOS Technical data

Essex Electronics

Essex Electronics EPOS Technical data

Guardian PBH05 instruction manual

Guardian

Guardian PBH05 instruction manual

Lasermet LS-20 instruction manual

Lasermet

Lasermet LS-20 instruction manual

Protecta AM210 User instruction manual

Protecta

Protecta AM210 User instruction manual

TEUFELBERGER treeMOTION MANUFACTURER'S INFORMATION AND USER INSTRUCTIONS

TEUFELBERGER

TEUFELBERGER treeMOTION MANUFACTURER'S INFORMATION AND USER INSTRUCTIONS

turck IMXK12-AI01 Series quick start guide

turck

turck IMXK12-AI01 Series quick start guide

Reliance 7260 Series Instructions for use

Reliance

Reliance 7260 Series Instructions for use

Climbing Technology CROCODILE manual

Climbing Technology

Climbing Technology CROCODILE manual

FALL SAFE INSPECTOR FS874 instruction manual

FALL SAFE

FALL SAFE INSPECTOR FS874 instruction manual

Clevertronics L10 Jumbo LJELED-40 Series Installation & maintenance instructions

Clevertronics

Clevertronics L10 Jumbo LJELED-40 Series Installation & maintenance instructions

Tractel CSK3 Installation, operating and maintenance manual

Tractel

Tractel CSK3 Installation, operating and maintenance manual

Safety 1st FLAT STEP GATE manual

Safety 1st

Safety 1st FLAT STEP GATE manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.