Battenfeld 222905 User manual

1
MECHANICAL VAULT
Instructions #1050227
Product #222905
Revision A

2
• This vault is designed to increase safety of unloaded rearm(s).Completely
unload the rearm(s) before using this device.
• Treat every rearm as if it were loaded.
• Always keep the muzzle pointed in a safe direction when handling
any rearm.
• Read the owner’s manual and instructions supplied with your rearm
before attempting to operate the rearm and use this vault.
• Always store unloaded and locked rearms in a safe place inaccessible to
children and other unauthorized persons. Store ammunition in a separate
locked or secure location.
• Do not store the combination to the vault in the same place as your vault.
• This vault is only part of an effective rearm safety and storage solution,
and should not be a substitute for safe rearm handling or secure storage.
• This vault is designed to be a convenient locking mechanism, but tools,
determination, and time can overcome any vault.
• Always engage the safety and never touch the trigger when placing or
removing the rearm from the vault.
• Always fasten the vault to a secure object. See mounting instructions.
IMPORTANT SAFETY INFORMATION
• This vault features a programmable lock mechanism. Upon removing this
product from the packaging for the rst time, be sure to program the lock to
a unique combination (See programming lock instructions for more details).
• You should document your programmed combination and store this
documented combination in a secure location, so that the combination
can be retrieved if forgotten. Combination should be stored in a secure
location, inaccessible to children and unauthorized individuals.
• If you lose your combination, there are no alternative methods for gaining
entry, rendering the vault unusable.Your vault will have to be destroyed to
access contents.
• Perchlorate Notice –This product may contain a CR coin cell lithium
battery.The State of California requires the following disclosure statement:
“Perchlorate Material – special handling may apply. See www.dtsc.ca.gov/
hazardouswaste/perchlorate”
IMPORTANT

3
CONTENT
LOCKING AND UNLOCKING
TO UNLOCK
• Rotate knob to the CLEAR position (Counter-
clockwise) to clear out any combinations that
may have previously been entered.
• Enter the correct combination. (The default code is: 1, 2, 3, 4, 5)
• Rotate knob to the UNLOCKED position. (Clockwise)
QTY ITEM
A 1 SUPERMAX VAULT
B 4 FENDER WASHERS
C 4 WOOD SCREWS
B
C
A

4
PROGRAMMING LOCK
• The default code is: 1, 2, 3, 4 , 5
• This vault features a programmable lock mechanism. Upon removing this product from the
packaging for the rst time, the vault should be programmed to a unique combination.You
should document your programmed combination and store this documented combination
in a secure location, so that the combination can be retrieved if forgotten.
L-Bracket and
Program Button
TO PROGRAM LOCK:
1. Open the vault and locate
the Program Button as
shown below.
TO LOCKVAULT
• Fully close vault lid.
• Rotate knob to the LOCKED position.
(Counter-clockwise)
• Check to make sure that vault is locked securely.
• Lift up on lid to ensure vault is locked.
• Attempt to rotate the knob to the UNLOCKED position. (Clockwise)

5
2. While the vault is open, turn the knob to the LOCKED position. (Counter-clockwise)
6. Carefully enter the new desired combination, ensuring that the buttons are
rmly pressed.
• Combinations can be a single button, all 5 buttons, or any number of buttons in any order.
Two or more buttons can be pushed simultaneously to create a unique combination (1&2
pushed simultaneously is a different combination then pushing 1 then 2, or 2 then 1). Each
of the 5 buttons can only be pushed once in a lock combination.
7. To save the new combination, turn the knob to the UNLOCKED position. (Clockwise)
8. Before locking the vault closed, lock the locking mechanism and test your code with lid open.
3. Enter the existing code. (The default code is: 1, 2, 3, 4, 5)
4. Push the L-Bracket towards the lock mechanism, which depresses the Program Button.
5. Turn the knob to the CLEAR position (Counter-clockwise) and then release the knob
allowing it to return to the LOCKED position.
Note: You should document your programmed combination and store this
documented combination in a secure location, so that the combination
can be retrieved if forgotten.The Combination should be stored in a
secure location, inaccessible to children and unauthorized individuals.
For more information on programming the lock, see our website for a demonstrational
video. http://www.btibrands.com

6
MOUNTING
TO FASTEN VAULT:
1. Find a location where it will be convenient to mount
and store the vault. Be sure to leave adequate room
for the vault lid to hinge open.
2. Remove the foam from the bottom
of the vault, and use a pencil to mark
the 4 mounting holes on the
mounting surface.
Always fasten the vault to a secure object before use.
3. Move the vault, and pre-drill the 4 marked holes for the mounting screws.
• For hard woods, use a 5/32” drill bit.
• For soft woods, use a 9/64” drill bit.
Hinge
space
4 mounting holes
4 Included fender
washers and wood screws
4. Place vault over pre-drilled holes, and
fasten vault down using the 4 included
fender washers and wood screws.
5. Replace the foam in the bottom of the vault.
(Bottom of vault)

7
INTERNAL LIGHT
This vault includes an internal light kit that automatically activates when the vault is opened.
• The Battery compartment holds 2 CR2032 batteries (Batteries included).The Battery
compartment is stored in a small slit in the internal foam.
• Upon rst use of the vault, remove the plastic tab in the Battery compartment,
to allow the batteries to contact the battery terminals.
• The Battery compartment features an on/off switch to allow the user to turn off the
automatic light, if desired.
Battery
Compartment
Automatic
Light
ON - OFF
Switch
ON - OFF
Switch
Battery
Compartment

8
Table of contents
Other Battenfeld Tools manuals
Popular Tools manuals by other brands

Eskridge
Eskridge 50 Series Service manual

Dolby Laboratories
Dolby Laboratories DP590 quick start guide

Cembre
Cembre ht51 Operation and maintenance manual

RAMSET
RAMSET SDP 1 Operator's manual and maintenance instructions

W&H
W&H assistina 301 plus Instructions for use

Orgapack
Orgapack OR-T 55 operating instructions