Wireless single channel signal transmission system for safety edges
Original operating instructions
General
1Safety instructions
2Common application
ENGLISH
370046C
07/19
TransmitterReceiver
Read these operating instructions thoroughly before putting the
device into operation and keep them for future reference.
Warning: Switch off the operating voltage before working on the
system. Only trained, qualied personnel may perform installation
and startup. The unit may only be repaired by the manufacturer. The
switching unit may only be used to protect against dangers on
crushing and shearing points and on automatic industrial doors and
Receiver Transmitter
gates (intended use). National and international regulations on industrial
door and gate safety must be complied with. Always consider the safety
functions of your application as a whole, never just in relation to one
individual section of the system. The installer is responsible for carrying out
a risk assessment and installing the industrial door system correctly.
i
Battery life up to 2 years, but it is recommended
batteries are changed every 12 months.
2.1 Sliding gate
Up to 7 transmitters can be linked with the same receiver
i
Further transmitters with separate manuals
Batteries
CR2032 Push
button
DIP-
switch
Push button DIP-switch
2
   
12
34 5 6
8k2
3 456
J1F1
1k2
3 456
J1F1
1k2
i
1 2
ON
1 2
ON
IN1
IN2
8k2
IN1
IN2
i
+/~ –/~
4.3 DIP switches
4.2 Status Outputs (relay contacts)
4.4 Cable routing, strain relief
3.1 DIP switch setting according to sensor (safety edge, switch contact)
4Receiver
3Transmitter
1
ON *Transmission frequency
869.525 MHz
1
ON 868.15 MHz
*= factory setting
Further instructions see separate transmitter manuals.
Determine the cable routing
Break out the corresponding part of the cover if necessary
 Punch hole into the grommet
 Thread cable
Fix cable with the clamp (➔strain relief)
Cable Ø: 3.1 – 5.2 mm
… or use holes
in the base plate
Break out …
Hint:
Power supply Conductor cross section 0.25 – 0.75 mm2
4.1 Wiring: Power supply and outputs with control
Control unit with
NC input
Control unit with
1.2 kOhm NC input
12–36V
AC/DC
Control unit with
8.2 kOhm input
Remove J1!
Example: RFGate 3.2.T
Sensor connection DIP switch Sensor connection DIP switch Note:
IN1 = active
IN2 = not used
Terminals
4–5
Terminals
3–6
No power supply closed open
System ready, sensor not pressed 8k2 closed
Sensor pressed closed open
Terminals
4–5
Terminals
3–6
Wicket door open (with RFGate 3.W.T) closed open
Broken cable between sensor and transmitter closed open
Transmitter with empty batteries closed open
3
1 2
ON
1
ON
i
ON
OK?
2x
*
2x
LED
5Installation sequence set-up
6Programming
6.
Transmitter:
install
4.
Transmitter:
insert
batteries
1.
Check DIP
switch settings
5.
Pairing (Chapter 6):
transmitter with receiver
Transmitters and receivers (also
among each others) must be at
least 0.5 m apart
Code saved
7.
Transmitter:
wire
3.
Turn on power
supply
2.
Install and wire
receiver
8.
System test: press
safety edge on gate
6.1 Pairing transmitter with receiver
2.
On the
transmitter
On the
receiver
Press and release button Beep Wait 2 beeps
10 sec.
1.
On the receiver
Press
button
Beep Lights up
orange
Release
button
Beep
BeepBeep
6.2 Clear pairings
6.3 Memory full
Press button
and keep pressed
Short beepsBeep WaitRelease
button
10 sec.
2 beeps
Beep
10 sec.
On the receiver All pairings
deleted
At power on,
or when program
button is pressed
Beep Beep Beep Beep
Beep Beep
Beep
* Quality of
the radio connection
1 beep: strong signal
2 beeps: good signal
3 beeps: medium signal
4
3x
OK?
  
Designed in Switzerland / Made in EU
LED
BBC Bircher Smart Access, BBC Bircher AG, Wiesengasse 20, CH-8222 Beringen, www.bircher.com
7Standard operation
9Technical data
8Optional cover xation (against vandalism)
10 EU Declaration of Conformity
11 WEEE
12 Contact
7.1 Receiver LED indicator 7.2 Warning indicator for low battery voltage
Input
actuated
LED red Receiver: 3 beeps every minute
To nd out which transmitter has low
battery voltage:
Press each edge. A beep indicates the low
battery.
Safety
OK
LED green
Battery voltage
low
Receiver
Supply voltage 12–36 V ACDC
Transmitter memory 7
Output 2 relays 24 V, 0.5 A
Power consumption 0.5 W @ 12 V; 1.2 W @ 24 V
Standard transmitter
Battery power 2x Lithium 3 V Type CR2032
Power consumption Transmitting: 17 mA standby: 16 µA
System
Frequency bands 869.525 MHz & 868.15 MHz
Range Under optimum conditions up to 100 m
Protection class
IEC 60529
IP65
Working temperature –20 °C to +55 °C
Optional
for external antenna Connector SMA (f)
for antenna with SMA connector (m)
Beep
See attachment
Drill a hole (Ø 3.5 mm) at the marked
position
Close the cover
 Tighten the enclosed screw
(3.5 mm x 8 mm self-tapping,T15)
To avoid the removal of the cover without
tools:
Use screw to attach the cover.
Devices with this symbol must be treated separately during disposal. This must be done in accordance with the laws of
the respective countries for environmentally sound disposal, processing and recycling of electrical and electronic equipment.

Other BBC Bircher Transmitter manuals

BBC Bircher XRF-1 User manual

BBC Bircher

BBC Bircher XRF-1 User manual

BBC Bircher XRF-T.2 User manual

BBC Bircher

BBC Bircher XRF-T.2 User manual

BBC Bircher XRF-TI User manual

BBC Bircher

BBC Bircher XRF-TI User manual

BBC Bircher XRF-T.2 Operating instructions

BBC Bircher

BBC Bircher XRF-T.2 Operating instructions

BBC Bircher Swissdoor RFGate 3.1 370046A User manual

BBC Bircher

BBC Bircher Swissdoor RFGate 3.1 370046A User manual

BBC Bircher XRF-TI User manual

BBC Bircher

BBC Bircher XRF-TI User manual

BBC Bircher XRF-T.2 User manual

BBC Bircher

BBC Bircher XRF-T.2 User manual

BBC Bircher RFGate 3.W.T User manual

BBC Bircher

BBC Bircher RFGate 3.W.T User manual

Popular Transmitter manuals by other brands

Black Box AC1003A-R2 manual

Black Box

Black Box AC1003A-R2 manual

HQ Power MICW43 user manual

HQ Power

HQ Power MICW43 user manual

Black Box CATX Series manual

Black Box

Black Box CATX Series manual

Rocket Fish RF-WHD200 user guide

Rocket Fish

Rocket Fish RF-WHD200 user guide

Metrix ST5484E manual

Metrix

Metrix ST5484E manual

PST PST-UM-2010-EN-2.1 user manual

PST

PST PST-UM-2010-EN-2.1 user manual

Emerson Rosemount OCX8800A manual

Emerson

Emerson Rosemount OCX8800A manual

ABB 3299-96908 manual

ABB

ABB 3299-96908 manual

Harris HT 35CD Technical manual

Harris

Harris HT 35CD Technical manual

Kramer F-121 user manual

Kramer

Kramer F-121 user manual

FONESTAR MSHTM-1200L quick start guide

FONESTAR

FONESTAR MSHTM-1200L quick start guide

NIVELCO EasyTREK SP-500 Pro Installation and programming manual

NIVELCO

NIVELCO EasyTREK SP-500 Pro Installation and programming manual

Intercoax IPIFY ETP-2704T-1R-PKG Quick install guide

Intercoax

Intercoax IPIFY ETP-2704T-1R-PKG Quick install guide

Panlux H-228/M quick start guide

Panlux

Panlux H-228/M quick start guide

ASCOM H952T installation guide

ASCOM

ASCOM H952T installation guide

IMI SENSORS 682B03 Installation and operating manual

IMI SENSORS

IMI SENSORS 682B03 Installation and operating manual

Absolute Process Instruments Cecomp F16DR Series instructions

Absolute Process Instruments

Absolute Process Instruments Cecomp F16DR Series instructions

HumanTechnik InfraLight II operating instructions

HumanTechnik

HumanTechnik InfraLight II operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.