1
RFGate 3.1
50
121
23
106
22 50
121
23
106
22
Wireless single channel signal transmission system for safety edges
Original operating instructions
General
1Safety instructions
2Common application
ENGLISH
370046A
05/18
TransmitterReceiver
Warning: Switch off the operating voltage before working on the
system. Only trained, qualied personnel may perform installation
and startup. The unit may only be repaired by the manufacturer. The
switching unit may only be used to protect against dangers on
crushing and shearing points and on automatic industrial doors and
gates (intended use). National and international regulations on
industrial door and gate safety must be complied with. Always
Receiver Transmitter
consider the safety functions of your application as a whole, never just in
relation to one individual section of the system. The installer is responsible
for carrying out a risk assessment and installing the industrial door system
correctly.
i
Battery life up to 2 years, but it is recommended
batteries are changed every 12 months.
2.1 Sliding gate
Up to 7 transmitters can be linked with the same receiver
i
Further transmitters with separate manuals
Batteries
CR2032
Push
button
push
button
2
   
12 34 5 6
8k2
3 456
J1F1
1k2
3 456
J1F1
1k2
i
1 2
ON
1 2
ON
IN1
IN2
8k2
IN1
IN2
i
4.2 DIP switches
4.3 Cable routing, strain relief
3.1 DIP switch setting according to sensor (safety edge, switch contact)
4Receiver
3Transmitter
1
ON *Transmission frequency
869.525 MHz
1
ON 868.15 MHz
*= factory setting
Further instructions see separate transmitter manuals.
Determine the cable routing
Break out the corresponding part of the cover if necessary
 Punch hole into the grommet
 Thread cable
Fix cable with the clamp (➔strain relief)
Cable Ø: 3.1 – 5.2 mm
… or use holes
in the base plate
Break out …
Hint:
Power supply Outputs: Relay contacts are shown unpowered Conductor cross section 0.25 – 0.75 mm2
4.1 Wiring: Power supply and outputs with control
Control unit with
NC input
Control unit with
1.2 kOhm NC input
12–36V
AC/DC
+/~ –/~
Control unit with
8.2 kOhm input
Remove J1!
Example: RFGate 3.2.T
Sensor connection DIP switch Sensor connection DIP switch Note:
IN1 = active
IN2 = not used
3
1 2
ON
1
ON
i
ON
OK?
2x
*
2x
5Installation sequence set-up
6Programming
6.
Transmitter:
install
4.
Transmitter:
insert
batteries
1.
Check DIP
switch settings
5.
Pairing (Chapter 6):
transmitter with receiver
Transmitter and receiver and
further transmitters must be at
least 0.5 m apart
Code saved
LED goes out
7.
Transmitter:
wire
3.
Turn on power
supply
2.
Install and wire
receiver
8.
System test: press
safety edge on gate
6.1 Pairing transmitter with receiver
2.
On the
transmitter
On the
receiver
Press and release button Beep Wait 2 beeps
10 sec.
1.
On the receiver
Press
button
Beep LED
lights up
Release
button
Beep
BeepBeep
6.2 Clear pairings
6.3 Memory full
Press button
and keep pressed
Short beepsBeep WaitRelease
button
10 sec.
2 beeps
Beep
10 sec.
On the receiver All pairings
deleted
At power on,
or when program
button is pressed
Beep Beep Beep Beep
Beep Beep
Beep
* Quality of
the radio connection
1 beep: strong signal
2 beeps: good signal
3 beeps: medium signal
4
3x
OK?
  
7Standard operation
9Technical data
8Optional cover xation (against vandalism)
10 EU Declaration of Conformity
11 WEEE
12 Contact
7.1 Receiver LED indicator 7.2 Warning indicator for low battery voltage
Input
actuated
LED red
LED
Receiver: 3 beeps every minute
To nd out which transmitter has low
battery voltage:
Press each edge. A beep indicates the low
battery.
Safety
OK
LED green
Battery voltage
low
Receiver
Supply voltage 12–36 V ACDC
Transmitter memory 7
Output 2 relays 24 V, 0.5 A
Power consumption 0.5 W @ 12 V; 1.2 W @ 24 V
Standard transmitter
Battery power 2x Lithium 3 V Type CR2032
Power consumption Transmitting: 17 mA standby: 16 µA
System
Frequency bands 869.525 MHz & 868.15 MHz
Range Under optimum conditions up to 100 m
Protection class
IEC 60529
IP65
Working temperature –20 °C to +55 °C
Beep
See attachment
Drill a hole (Ø 3.5 mm) at the marked
position
Close the cover
 Tighten the screw (3.5 mm x 8 mm
self-tapping,T15) enclosed
To avoid the cover removal without
tools:
Use screw to attach the cover.
Devices with this symbol must be treated separately during disposal. This must be done in accordance with the laws of
the respective countries for environmentally sound disposal, processing and recycling of electrical and electronic equipment.
Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, www.bircher-reglomat.com | Swissdoor ApS, Stenhuggervej 2, 5471 Søndersø , www.swissdoor.dk

Other BBC Bircher Transmitter manuals

BBC Bircher XRF-TI User manual

BBC Bircher

BBC Bircher XRF-TI User manual

BBC Bircher XRF-T.2 Operating instructions

BBC Bircher

BBC Bircher XRF-T.2 Operating instructions

BBC Bircher RFGate 3.1 370046C User manual

BBC Bircher

BBC Bircher RFGate 3.1 370046C User manual

BBC Bircher RFGate 3.W.T User manual

BBC Bircher

BBC Bircher RFGate 3.W.T User manual

BBC Bircher XRF-T.2 User manual

BBC Bircher

BBC Bircher XRF-T.2 User manual

BBC Bircher XRF-1 User manual

BBC Bircher

BBC Bircher XRF-1 User manual

BBC Bircher XRF-T.2 User manual

BBC Bircher

BBC Bircher XRF-T.2 User manual

BBC Bircher XRF-TI User manual

BBC Bircher

BBC Bircher XRF-TI User manual

Popular Transmitter manuals by other brands

Nice P1S BD instructions

Nice

Nice P1S BD instructions

alphatronics BA 2 user manual

alphatronics

alphatronics BA 2 user manual

Nolan NSTX3C2 Series user guide

Nolan

Nolan NSTX3C2 Series user guide

WebGate WebEye A10 user guide

WebGate

WebGate WebEye A10 user guide

Bear TA Bear TA user manual

Bear TA

Bear TA Bear TA user manual

Philips SHB1900 user manual

Philips

Philips SHB1900 user manual

Emerson Rosemount 3051 Series quick start guide

Emerson

Emerson Rosemount 3051 Series quick start guide

Endress+Hauser Cerabar S PMC71 operating instructions

Endress+Hauser

Endress+Hauser Cerabar S PMC71 operating instructions

Motorline professional M170 User's and installer's manual

Motorline professional

Motorline professional M170 User's and installer's manual

Westlock Controls Corporation D510 Installation and operation manual

Westlock Controls Corporation

Westlock Controls Corporation D510 Installation and operation manual

DEMAG DRC-10 operating instructions

DEMAG

DEMAG DRC-10 operating instructions

Lectrosonics HMA-941 Series quick start guide

Lectrosonics

Lectrosonics HMA-941 Series quick start guide

PCB Piezotronics IMI SENSORS 682C03 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 682C03 Installation and operating manual

Dwyer Instruments Magnehelic 605-1 Installation and operating instructions

Dwyer Instruments

Dwyer Instruments Magnehelic 605-1 Installation and operating instructions

WEVI VW-5 operating instructions

WEVI

WEVI VW-5 operating instructions

DogWatch IB-200 operating instructions

DogWatch

DogWatch IB-200 operating instructions

Datcon DT1012 operating instructions

Datcon

Datcon DT1012 operating instructions

Traxxas TQ 6516 owner's manual

Traxxas

Traxxas TQ 6516 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.