BENTEL SECURITY srl reserves the right to modify the technical specifications of this product ithout prior notice.
IMPORTANT: The following information is for disassembled Control Panels ONLY.
Ensure that the Manual you are using corresponds to, or is higher than the one requested
on the “RELEASE ISSUES” label (see below).
Manual Release
Firmware Release
Software Release
RELEASE ISSUES
OK32 1.01
Installation Manual
User Manual
Keypad Prog. Man.
Main Unit Manual
Kyo Unit Software
1.1
1.1
1.1
1.1
5.10
If the Manual/ YO Unit Software release does not correspond, DO NOT attempt to as-
semble or install the Control Panel.
The Manual Release Number can be found at the bottom of the last page, between the
Code and Date, as shown in the Fig. below.
ISTUCBLEUNKYO 190503 P70
1.2
Manual
Release
Number
DateCode
KYO 4 M – KYO 8 M – KYO 8W M – KYO 32 M – KYO 4 P – KYO 8 P – KYO 8W P – KYO 32 P
KYO 8G L-SW1 – KYO 8G L-SW2 – KYO 32G L-SW1 – KYO 32G L-SW2
KYO 8GWP-SW1 – KYO 8GWP-SW2 – KYO 8GWL-SW1 – KYO 8GWL-SW2
KYO 8G P-SW1 – KYO 8G P-SW2 – KYO 32G P-SW1 – KYO 32G P-SW2
Hereby, Bentel Security, declares the above mentioned Control Panels to be in compliance with the
essential requirements and other relevant provisions of 1999/5/EC Directive.
The complete R&TTE Declaration of Conformity for each Panel can be found at
www.bentelsecurity.com/dc.html.
These Control Panels comply ith
Installation of these systems must be carried out strictly in accordance ith the instructions
described in this manual, and in compliance ith the local la s and byla s in force.
The above mentioned Control panels have been designed and made
to the highest standards of quality and performance.
The manufacturer recommends that the installed system should be completely tested at least once a month.
BENTEL SECURITY Srl shall not assume the responsibility
for damage arising from improper application or use.
The above mentioned Control panels have no user-friendly components, therefore,
should be serviced by authorized personnel only.
CEI 79-2 2 ed. 1993
a.
®®

3
®®
Section 1 - Introduction .............................................................5
Certification Formalities ......................................................................................... 5
General Features ..................................................................................................... 5
About the System ....................................................................................................
Control panel Versions ...........................................................................................
Components and Accessories .............................................................................. 8
Technical Specifications ........................................................................................ 9
Section 2 - Identification of Components .............................. 10
KYO 4 M — KYO 8 M — KYO 8W M — KYO 32 M ................................................. 10
KYO 4 P — KYO 8 P — KYO 8W P — KYO 32 P .................................................... 11
KYO 8G P-SW1 — KYO 8GWP-SW1 — KYO 32G P-SW1 ..................................... 12
KYO 8G P-SW2 — KYO 8GWP-SW2 — KYO 32G P-SW2 ..................................... 13
KYO 8G L-SW1 — KYO 8GWL-SW1 — KYO 32G L-SW1 ..................................... 14
KYO 8G L-SW2 — KYO 8GWL-SW2 — KYO 32G L-SW2 ..................................... 15
Section 3 - Mounting the Components .................................. 19
Introduction ........................................................................................................... 19
Boxes and Accessories ....................................................................................... 19
Installing the Transformer and Mains Screw Terminal - Fused ......................... 20
Metal box (BOX-M) ............................................................................................ 20
Plastic box (BOX-P) .......................................................................................... 21
Mounting K4-K8-K8W-K32 PCBs .......................................................................... 22
Metal box (BOX-M) ............................................................................................ 22
Plastic box (BOX-P) .......................................................................................... 22
Installing ‘G’ series PCBs (K8G-K8GW-K32G) ..................................................... 23
Plastic box (BOX-P) .......................................................................................... 23
Metal box BOX-L ............................................................................................... 23
Installing the Switching Power Supply ................................................................ 24
Installing BAQ15T12 Switching Power Supplies ............................................. 24
Installing BAQ35T12 Switching Power Supplies ............................................. 25
Replacing BAQ35T12 Fuse ............................................................................. 25
Earthing the PCB ................................................................................................... 26
Marking Ticket ....................................................................................................... 26
Connecting the KST Thermal Probe .................................................................... 26
Connecting the NC2/VOX Voice Board ................................................................. 2
Metal box ........................................................................................................... 27
Plastic box ........................................................................................................ 27
PCB Identification Label ....................................................................................... 28
TABLE OF CONTENTS

4Multifunction Control Panel
®®
Section 4 - Installing the Control anel ................................. 29
Mounting the Control Panel .................................................................................. 29
Opening and Closing the Control Panel ............................................................... 30
Section 5 - Installing the NC2/VOX......................................... 32
General Features ................................................................................................... 32
Additional VOX-REM Modules ............................................................................... 32
Installing Additional VOX-REM Modules .......................................................... 32
Record / Play Messages ....................................................................................... 33
Selecting Messages ........................................................................................ 34
Recording Alarm Messages ............................................................................ 34
Playing Messages ............................................................................................ 34
Programming ........................................................................................................ 35
Activation ............................................................................................................... 35

5
®®
Section 1 - Introduction
This Manual is designed for anyone using a Control panel from the KYO range.
Most of the features described in this Manual are included on all KYO Control
panels (refer to Table 1.1). Ho ever, some features are included on certain
models only, in such cases, the Control panel ill be specified.
8 Programmable Input Zones (4 for KYO 4 M and KYO 4 P)
Expandable to 32 Input Zones ia optional M-IN/6 Input Expanders (for
KYO 32 series Control panels)
1 Balanced 24h Tamper Zone
1 Programmable Alarm Output: 1A relay (3A on ‘G’ models)
General Features
SECTION 1 - INTRODUCTION
Control Panel
Certification Formalities
The KYO-Unit series can be purchased as out-of-the-box Control pan-
els, or as separate package components. Bentel ecurity .r.l declares
that KYO-Unit separate package components comply with the essen-
tial requirements and other relevant provisions of Directive R&TTE
1999/5/CE — only when they are assembled by a security professional,
and are used as part of one of the Control panels provided for in
ection 3, and indicated in Table 1.1. in this Manual. Bentel ecu-
rity .r.l. declares that CE Certification is not applicable when KYO
separate package components are improperly assembled or used.
Table 1.1 - Version
Version
Component
PCB Box Transf. TRF Power Supply
BAQ15T12
Power Supply
BAQ35T12
KYO 4 M K4 BO X-M
KYO 8 M K8 BO X-M
KYO 8W M K8W BO X-M
KYO 32 M K32 BO X-M
KYO 4 P K4 BO X-P
KYO 8 P K8 BO X-P
KYO 8W P K8W BO X-P
KYO 32 P K32 BO X-P
KYO 8G P-SW 1 K8G BO X-P
KYO 8GWP-SW1 K8G W BO X-P
KYO 32G P-SW 1 K32G BO X-P
KYO 8G P-SW 2 K8 G BO X-P
KYO 8GW P-SW 2 K8G W BO X-P
KYO 32G P-SW 2 K32G BO X-P
KYO 8G L-SW 1 K8G BO X-L
KYO 8GW L-SW 1 K8G W BO X-L
KYO 32G L-SW 1 K32G BO X-L
KYO 8G L-SW 2 K8G BO X-L
KYO 8GW L-SW 2 K8 G W BO X-L
KYO 32G L-SW 2 K3 2G BO X-L

6Multifunction Control Panel
®®
Auxiliary Open-Collector Outputs (OC):
3 x 150 mA for KYO 4, KYO 8, KYO 8W and KYO 32 series
5 x 500 mA for KYO 8 G, KYO 8 GW and KYO 32 G series
Expandable to 14 x 150 mA Outputs for KYO 32 series
Expandable to 16 x 150 mA Outputs for KYO 32 G series
Metal box (Model M or L) or Plastic Box (Model P)
Accepts Con entional Fire Detectors, and pro ides restoral facility
Supports up to 8 Keypads
Supports up to 16 Readers (ECLIPSE and/or PROXI)
Accepts up to 128 SAT Keys and/or PROXI-CARDs
Manages 4 independent Partitions (8 for KYO 32 and KYO 32 G)
3 Arming Modes (Global, A Mode and B Mode): A and B Mode can be
programmed as: Away, Stay or Stay with no Entry delay
Auto-Arming for each Partition on Daily or Weekly basis
24 Programmable Codes (4 to 6 digits)
Partition Bypass for Patrol purposes with automatic or manual Rearming
Can be programmed from an LCD or LED Keypad
Can be programmed from a computer ia RS232 link cable or ia telephone
Power Supplies:
Integrated 1A linear Power Supply in KYO 4, KYO 8, KYO 8W and KYO 32
1.5A Switching Power Supply in SW1 Models
3A Switching Power Supply in SW2 Models
Touch-tone (MF) or Pulse dialling
Manages 8 Telephone numbers for Alarm and Central Station calls
Supports the following Reporting Formats:
ADEMCO / SILENT KNIGHT - Slow 10 baud - 3/1, 4/1, 4/2
ADEMCO / SILENT KNIGHT - Fast 14 baud - 3/1, 4/1, 4/2
FRANKLIN / SECOA / DCI-VERTEX - Fast 20 baud - 3/1, 4/1, 4/2
RADIONICS - 40 baud - 3/1, 4/1, 4/2
SCANTRONIC - 10 baud - 3/1, 4/1, 4/2
CONTACT ID
CESA
Accepts commands from touch-tone phones (Arm, Disarm, Turn ON/OFF
Main board Outputs; Remote Talk/Listen-in — requires optional NC2/VOX
Voice Board
Manages Voice Calls (requires optional NC2/VOX Voice Board)
Remote Telephone Access ia Dialler or Answer Mode
Remote Talk/Listen-in (requires optional NC2/VOX Voice Board)
256 E ent Logger (can be iewed on computer or LCD Keypad) on Series
32 Models. 128 E ents on Series 4-8 Models.
3 function keys for immediate Alarm calls from Keypad
Programmable Test Call
Teleser ice Management
Double Call
Line-sharing Management
Digital Dialler

7
®®
Section 1 - Introduction
The Control panel is made up of a Control Unit, Digital Communicator and
Modem. It can be controlled from remote Keypads and/or Digital Key/Card
Readers.
The Digital Communicator can call up to 8 Telephone numbers for Teleser ice
and communication to Central Stations. You can program the system to report
e ents using any one of the supported formats.
The NC2/VOX Voice board (accessory item) will allow the Communicator to
send 8 Voice messages to up to 8 Telephone numbers. The NC2/VOX Voice
board also pro ides the Talk/Listen-in feature.
The B-MOD Modem and Management software will allow you to program,
control and Teleser ice (pro ide remote maintenance) from a remote computer.
The B-MOD/ x Modem and the WinBCS software will allow you to program,
control, Teleser ice and Monitor the system from a remote computer.
All E ents, Alarms and Troubles, complete with Customer and E ent details will
be logged on the E ent Logger.
The User can access the system o er the phone, in order to:
Arm/Disarm the system
Turn ON/OFF Reser ed Outputs
Acti ate Talk/Listen-in sessions (NC2/VOX required)
This Control panel can be programmed:
a) on-site, using an LCD or LED Keypad (accessory item);
b) on-site, using an RS232 Computer link;
c) from remote computer, using a modem and downloading software.
About the System
The Control panel
The Digital
Communicator
Voice Messages
using NC2/VOX
Teleservice
Telemonitoring
Programming the
system
Table 1.2 - Functional differences between Models
Model Wireless
Management
Features
Partition Input (Zone) O.C. Output
KYO 4 M
KYO 4 P No 4 4 3 x 150 mA
KYO 8 M
KYO 8 P No 4 8 3 x 150 mA
KYO 8W M
KYO 8W P Yes 4 8 3 x 150 mA
KYO 32 M
KYO 32 P Yes 8 8
Expandable to 32*
3 x 150 mA
Expandable to 14 **
KYO 8G Series No 4 8 5 x 500 mA
KYO 8GW Series Yes 4 8 5 x 500 mA
KYO 32G Series Yes 8 8
Expandable to 32*
5 x 500 mA
Expandable to 16 **
** The M-IN/6 Expander Module manages 6 Inputs
** The M-OUT/6 Expander Module manages 6 OC Outputs — 150 mA (6 x 150 mA)
Control panel Versions
Accessing the system
using a remote
Touch-tone Telephone

8Multifunction Control Panel
®®
Table 1.3 - Components and Accessory Items
Code Description
K4 - K8 - K8W - K32 PCB for KYO4, KYO8, KYO8 W and KYO32
K8G - K8GW - K32G PCB for KYO8 G, KYO8 GW and KYO32 G
BOX-M Metal box for M Models
BOX-P Plastic box for P Models
BOX-L Metal box for L Models
TRF 17 Vac - 1.5 A Power Transformer
BAQ15T12 1.5 A Switching Power Supply for SW1 Models
BAQ35T12 3 A Switching Power Supply for SW2 Models
MIA/S or MIA/D LCD Keypad
Alison/S or Alison/DV LCD Keypad (DV Model with built-in Voice Module)
OMNIA/TAST-R LCD Keypad
NC2/TAST LED keypad
ICON/KP LED keypad
Alison/8L or Alison/32LP LED Keypad (32LP Model with built-in PROXI Reader)
ECLIPSE Flush Mount Contactless Key Reader
PROXI Proximity Reader
SAT Digital key for ECLIPSE and PROXI Readers
PROXI-CARD PROXI Card
NC2/VOX Voice Board
VOX-REM Talk/Listen-In Zone Expander Module (Microphone + Loudspeaker)
M-IN/6 6 Input Expander Module
M-OUT/6 6 Output Expander Module (150 mA)
OMNIA/4R 4 relay Module for Output Expanders
KISUNIT Manual Kit
VECTOR/RX and /RX8 Wireless Receiver
ARC20 Wireless Key for Vector/RX and Vector/RX8
AMD10 Wireless Pet Immune PIR for Vector/RX and Vector/RX8
AMC10 Wireless Magnetic Contact for Vector/RX and Vector/RX8
ASD10 Wireless Smoke Detector for Vector/RX and Vector/RX8
AGD10 Wireless Glassbreak Detector for Vector/RX and Vector/RX8
B-MOD Tel es er vi ce M o d em
B-MOD/RX Teleservice and Telemonitoring Modem
SECURITY SUITE Management Software
CVSER/9F9F Computer Serial Link
ADSER/9M25F Adapter for CVSER/9F9F link cable for 25 Pole Serial Ports (DB-25)
KST Thermal Probe (for GModels only)
OVC-Link Output Voltage Control wire (for GModels only)
ASNC Microswitch provides Snatch protection for MIA and ALISON Keypads, and
Snatch/Tam per protection for BOX-P
MINI-ASNC Snatch Microswitch for PROXI-REA DERs
MAXI-ASNC Tamper Microswitch for Metal boxes (BOX-M and BOX-L)
Components and Accessories

9
®®
Section 1 - Introduction
Technical Specifications
Table 1.4 - Technical Specifications
Control Panels
Specifications
Values
KYO 4 M
KYO 4 MKYO 4 M
KYO 4 M
KYO 8 M
KYO 8 MKYO 8 M
KYO 8 M
KYO 8W M
KYO 8W MKYO 8W M
KYO 8W M
KYO 32 M
KYO 32 MKYO 32 M
KYO 32 M
KYO 4 P
KYO 4 PKYO 4 P
KYO 4 P
KYO 8 P
KYO 8 PKYO 8 P
KYO 8 P
KYO 8W P
KYO 8W PKYO 8W P
KYO 8W P
KYO 32 P
KYO 32 PKYO 32 P
KYO 32 P
KYO 8 G P-SW1
KYO 8 G P-SW1KYO 8 G P-SW1
KYO 8 G P-SW1
KYO 8 GWP-SW1
KYO 8 GWP-SW1KYO 8 GWP-SW1
KYO 8 GWP-SW1
KYO 32 G P-SW1
KYO 32 G P-SW1KYO 32 G P-SW1
KYO 32 G P-SW1
KYO 8 G L-SW1
KYO 8 G L-SW1KYO 8 G L-SW1
KYO 8 G L-SW1
KYO 8 GWL-SW1
KYO 8 GWL-SW1KYO 8 GWL-SW1
KYO 8 GWL-SW1
KYO 32 G L-SW1
KYO 32 G L-SW1KYO 32 G L-SW1
KYO 32 G L-SW1
KYO 8 G P-SW2
KYO 8 G P-SW2KYO 8 G P-SW2
KYO 8 G P-SW2
KYO 8 GWP-SW2
KYO 8 GWP-SW2KYO 8 GWP-SW2
KYO 8 GWP-SW2
KYO 32 G P-SW2
KYO 32 G P-SW2KYO 32 G P-SW2
KYO 32 G P-SW2
KYO 8 G L-SW2
KYO 8 G L-SW2KYO 8 G L-SW2
KYO 8 G L-SW2
KYO 8 GWL-SW2
KYO 8 GWL-SW2KYO 8 GWL-SW2
KYO 8 GWL-SW2
KYO 32 G L-SW2
KYO 32 G L-SW2KYO 32 G L-SW2
KYO 32 G L-SW2
Voltage 230V~50Hz ±10% 100÷240 V~47÷63Hz 230V~50Hz ±10%
Maximum Current draw 0,2 A 0,42 A 0,5 A
Maximum Power 45 W 50 W 115 W
Power Supply Battery-charger 13.8 V_±1% / 1 A 13.8 V_±2% / 1.5 A 13.8 V_±1% / 3 A
Insulation Class I
Maximum Current
available for peripherals 0.6 A 1 A 2.3 A
Max. Battery Charge Current 0.3 A 0.5 A
Battery Housing
(Brand and Type)
12V - 7Ah (17Ah in "L" models)
YUASA NP7-12 FR or Equivalent with UL94-V2 (or superior) Case Flame Class
IP Protection Level IP30
Recognized MF Tones Minimum Level 200 mVpp (-23 dBV)
Operating Temperature +5 ÷ +40º C
Dimensions mm (W x H x D) 235 x 269 x 77 309 x 227 x 89 339 x 488 x 108 309 x 227 x 89 339 x 488 x 108
Weight (without Battery) 2.7 Kg 1.8 Kg 1.2 Kg 5.3 Kg 1.3 Kg 5.4 Kg
Complies with
CEI Normative Laws EN 60950:2000 - EN50081-1:1992 - EN50130-4:1995+A1:1998 - CEI 79-2 2a
ed. 1993
COMPONENTS and ACCESSORY ITEMS
Description Max. Current Draw
(mA) Dimensions (W x H x D) mm
Main
MainMain
Main
Board
BoardBoard
Board
K4-K8-K8W-K32 100 122 x 118
K8G-K8G-K32G 150 166 x 109
Keypad
KeypadKeypad
Keypad
MIA/S and MIA/D 50 164 x 133 x 44
ALISON/S
ALISON/DV 90 143 x 115 x 38
ALISON/8L
ALISON/32LP 90 160 143 x 115 x 38
OMNIA/TAST-R 50 160 x 73 x 30
NC2/ TAST 80 117 x 96 x 25
ICON/KP 80 160 x 73 x 30
Reader
ReaderReader
Reader ECLIPSE 30 20 x 44 x 48
PROXI 30 78 x 108 x 22
Expan-
Expan-Expan-
Expan-
der
derder
der
M-IN/6 (Input) 27 108 x 101 x 34
M-OUT/6 (Output) 11 108 x 101 x 34
NC2/VOX Voice Board 30 58 x 71
VectorRX Receiver 50 146 x 290 x 28

10 Multifunction Control Panel
®®
SECTION 2 - IDENTIFICATION OF COMPONENTS
The numbers in boldface in square brackets “[ ]”, in this and other Manuals
relevant to this product, refer to the components described in this section.
Fig. 2.1 - KYO 32 M Control panel complete with NC2/VOX Voice Boar (accessory item)
19b
2
19a
17
LE LI
3332 3 4 35 36
56 789a
AC
30 31
COMNC 0201+B
19 20 2221 2423
GRN
25 26
REDBLKYEL
27 2928
03
4
14
11d
15
2
4
12a
2 2
11
9c
10
10
3a
3a
13c
13a
18a
3a
3a
3a
19c
4
11b
11d 9d
18b
KYO8
18c
KYO 4 M KYO 8 M KYO 8W M KYO 32 M

11
®®
Section 2 - Identification of Components
N
L
L
N
51
96
KYO8
9d
11
10 22546 783b 3b
9a
15
2
12a
3c
4
19b
2
11a
19a
4
9c
10
11a
13b
18a
17
3c
12b
12b
14
18b
11f
11e
18c
19c
Fig. 2.2 - KYO 32 Control panel complete with NC2/VOX Voice Boar (accessory item)
KYO 4 P KYO 8 P KYO 8W P KYO 32 P

12 Multifunction Control Panel
®®
Fig. 2.3 - KYO 32G P-SW1 Control panel complete with NC2/VOX Voice Boar (accessory item)
KYO 8G P-SW1 KYO 8GWP-SW1 KYO 32G P-SW1
BPI
+F
LN
1
1
22 5
4683b 3b
11g
15
2
12a
28
2
11a
9b
9c
20b
11a
3c
12b
729a
24
22b
19a
10
4
17
4
12b
10
9e
29b
24
13b
26
9d
18a
18b
11c
11f
11e
13b

13
®®
Section 2 - Identification of Components
Fig. 2.4 - KYO 32G P-SW2 Control panel complete with NC2/VOX (accessory item)
KYO 8G P-SW2 KYO 8GWP-SW2 KYO 32G P-SW2
BPI
+F
11
22 5
4683b 3b
15
2
17
12a
9e
27
2
11a
28
9b
25a
9c
20a
11a
3c
12b
12b
729a
25b
19a
23
22a
21
10
10
26
3d
4
3c
29b
24
13b
9d
18a
18b
11g
11c
11f
11e

14 Multifunction Control Panel
®®
Fig. 2.5 - KYO 32G L-SW1 Control panel complete with NC2/VOX Voice Boar (accessory item)
KYO 8G L-SW1 KYO 8GWL-SW1 KYO 32G L-SW1
BPI
+F
LN
17
11d
15
26
6
1
9e
13c
18b
3a
10
11e
11d
18a
3a
11b
11f
5
2
24
20b
28
22b
19a
24
13c
3a
10
9c
9b
11g
29b
79d829a
12a
11c
4
4
2
3e
16

15
®®
Section 2 - Identification of Components
Fig. 2.6 - KYO 32G L-SW2 Control panel complete with NC2/VOX Voice Boar (accessory item)
KYO 8G L-SW2 KYO 8GWL-SW2 KYO 32G L-SW2
BPI
+F
17
11d
15
26
6
1
9e
13c
18b
3a
10
11e
11d
18a
3a
11b
11f
5
2
24
20a
28
22a
24
3a
10
9c
9b
11g
29b
79d829a
12a
11c
4
4
2
27
21
23
19a
25a
25b
3d
3e
16

16 Multifunction Control Panel
®®
Table 2.1 - Identification the Main Unit Parts
Part Description
1Frontplate Screws (2)
2Locations (4) for backplate screws (Ø = 5 mm)
3a Reverse locking PCB supports (see Figure 3.3)
3b PCB location Tabs
3c Locations (2) for PCB screws
3d Arrester for BAQ35T12 Switching Power-Supply/Battery Charger
3e 13 mm plastic support
4Terminal Board
5DB-9 male connector for computer link
6BPI Level Jumper: 12Vk5V 5 V (at default); 12Vj5V 12 V
7Firmware Release label
8Stop Alarm Jumper: Open ( ) Alarms Uninhibited (default);
Stop Alarm Jumper: Closed (K) Alarms Inhibited
9a BATT Fuse: F8A - 250V
9b BPI Fuse (Fuse — protects BPI Bus [+] terminal): F2A - 250V
9c +B Fuse: F5A - 250V (K4, K8, K8W and K32 boards)
+F Fuse: F5A - 250V (Only for 'G' boards)
9d Reserved Jumper
9e Auxiliary Connector for BPI Devices (K8G, K8GW, K32 and K32G boards ONLY)
10 Connector for Tamper and Snatch Microswitches (N.O. at default)
11a Tamper Microswitch for BOX-P (A ccessory Item, code ASNC)
11b Tamper Microswitch for BOX-M and BOX-L (Accessory Item, code MAXI-ASNC)
11c On-Board Tamper Microswitch (Only for 'G' PCBs)
11d Plastic spacers (2): inside the MAXI-A SNC Tamper Microswitch package
11e Snatch Microswitch (A ccessory Item)
11f Snatch Microswitch bracket
11g
Jumper for on-board Tamper-Microswitch [11c]:
Open (J) Microswitch disabled,
Closed (K) Microswitch enabled (at default)
12a Optional Voice Board (Order Code: NC2/VOX — refer to Section 5)
12b Voice Board Holder
13a Earth Wire
13b Earth Wire on PCB - terminal (L=400 mm)
13c Earth Wire on PCB - terminal (L=120 mm)
14 Power Transformer — 220-17Vac-1.5A (Order Code: TRF)
15 Battery wires
16 Cable supports
17 Cable entry
18a Marking ticket
18b Release Label

17
®®
Section 2 - Identification of Components
Table 2.2 - Identification of the Switching Power Supply Components
Part Description
18c Cable Tie Bases
19a Mains Screw Terminal —for Mains and Earth
19b General protection Fuse: F500MA - 250
19c Adhesive Label
20a BAQ35T12 Switching Power Supply
20b BAQ15T12 Switching Power Supply
21 Mains LED (ON = Mains OK)
22a Fine Adjustment Trimmer
22b KST Jumper —If you are connecting a KST Thermal Probe to the battery, this
jumper must be inserted.
23 Auxiliary Terminals for system peripheral (Output = 13.8 Vcc)
24 Screw to secure the Switching Power Supply to the backplate:
1 x BAQ35T12 - 2 x BAQ15T12
25a Screw for the Switching Power Supply
25b Snap Rivet
26 Thermal probe —to be fitted to the battery (Order Code: KST)
27 Fuse —protects Switching Power Supply (F2A-250V)
28 Fuse —protects against Battery polarity inversion (F6.3A -250V)
29a Connector for the Switching Power Supply
29b OVC-Link wire (Output Voltage Control)

18 Multifunction Control Panel
®®
Table 2.3 - Identification of the NC2/VOX Components
Part Description
35 LOC-MIC Jumper: K(at Default) - NC2/VOX Microphone Enabled
LOC-MIC Jumper: J- NC2/VOX Microphone Disabled
36 REM-MIC Jumper: J(at Default) - VOX-REM Remote Microphone Disabled
REM-MIC Jumper: K- VOX-REM Remote Microphone Enabled
37 Terminal board for VOX-REM Module
38 REM-SP Jumper: J(at Default) - VOX-REM Remote Speaker Disabled
REM-SP Jumper: K- VOX-REM Remote Speak Enabled
39 LOC-SP Jumper: K(at Default) - NC2/VOX Speaker Enabled
LOC-SP Jumper: J- NC2/VOX Loudspeaker Disabled
40 Flat Cable
41 Microphone
42 PLAY button
43 RECORD button
44 Status LEDs
Fig. 2.7 - NC2/VOX Voice Boar Components
41
42
43
44 35 36 37
38
40
39

19
®®
Section 3 - Mounting the Components
SECTION 3 - MOUNTING THE COMPONENTS
Introduction
Please read this section to get an o erall iew of the steps in ol ed in installing
Control panels from the KYO Unit range.
The end of the stranded conductor must not be soft soldered in places here it is
subject to contact pressure. The Mains iring must comply ith the rules for
double or reinforced insulation. Use an adhesive cable grip to secure the ires
to the terminal boards.
Boxes and Accessories
Metal and Plastic boxes are a ailable.
The Metal Box (BOX-M) kit includes the following parts:
18 Balance Resistors — 10 Kohm
4 plastic PCB supports
1 x 12cm Earth wire (Yellow-Green) with eyelet [13c]
4 hexagonal nuts — M3
2 Parker screws — 2.9 x 7.5 to secure the Frontplate
The Plastic Box (BOX-P) kit includes the following parts:
18 Balance Resistors — 10 Kohm
1 x 40 cm Earth wire (Yellow-Green) without eyelet [13b]
2 Parker screws — 2.9 x 7.5 to secure the PCB
1 Parker screw — 2.9 x 9.5 to secure the BAQ35T12 Switching Power Supply
2 Parker screws — 3.9 x 9.5 to secure the Frontplate
1 Parker screw — 3 x 14.2 to secure the Mains Screw Terminal
2 Parker screws — 3 x 8 to secure the Transformer or BAQ15T12.
The Large Metal Box (BOX-L) kit includes the following parts:
18 Balance Resistors — 10 Kohm
1 x 13 mm plastic support for the PCB
4 plastic supports for the PCB
2 x 12 cm Earth wire (Yellow-Green) with eyelet [13c]
1 hexagonal nut — M3
1 plastic Snatch microswitch bracket [11e]
2 x 3mm cogged metal washers
2 screws 3x6
2 screws 3x8
2 Parker screws — 2.9 x 7.5 to secure the frontplate
1 “Protected En iroment” label
Metal box BOX-M
Plasti box BOX-P
Large Metal Box
BOX-L

20 Multifunction Control Panel
®®
The Transformer (see Fig. 3.1) package includes the following parts:
1 Mains Screw Terminal - Fused [19a] — 500 mA
1 Adhesi e Label [19c] for the Mains Screw Terminal
1 x 12 cm Earth wire (Yellow-Green) with eyelet [13a] for earthing the
Metal box or Transformer
To install the Transformer (Order Code T F), work carefully through the fol-
lowing steps (refer to Fig. 3.1).
Metal box (BOX-M)
1.Stick the label [19c] onto the backplate (one aperture must be positioned
o er the fixed screw, and the other o er the Mains Terminal [19a] screw
location.
2.Fit the Mains Screw Terminal [19a] onto the fixed screw (as indicated on
the label) then, using the hexagonal nut, secure it to the backplate.
3.Mount the Transformer onto the 2 fixed screws (M3x10) on the backplate
of the Metal box.
4.Fit the eyelet terminal [13a] to the fixed screw (as shown in Fig. 3.2a) then,
using two hexagonal nuts, secure the transformer to the backplate.
5.Connect the Transformer primary ( ED wires) to terminals [N] and [L].
6.Connect the free end of the Earth wire [13a] to the [QQ
QQ
Q] terminal on the
Mains Screw Terminal [19a] (as shown in Fig. 3.2a).
Use the cable tie bases (refer to [18c] in Fig. 2.1) to bunch the Red ires of the
Transformer and the Earth ire [13a].
Installing the Transformer and Mains Screw Terminal - Fused
71.75 mm
Fixed screws
M3x10 71.75 mm
Metal Box — BOX-M Plastic Box — BOX-P
Screw Location Ø 2.5mm
[19c]
[19a]
[19c]
[19a]
M3 Nut to secure
Mains Terminal Screw to secure
Terminal board
Fig. 3.1 - Installing the Transformer an Mains Terminal boar
Other manuals for KYO 4 M
3
This manual suits for next models
19
Table of contents
Other Bentel Security Security System manuals

Bentel Security
Bentel Security KRP10 User manual

Bentel Security
Bentel Security CALL-FPI User manual

Bentel Security
Bentel Security KYO Series Owner's manual

Bentel Security
Bentel Security Wave Series User manual

Bentel Security
Bentel Security HS900 User manual

Bentel Security
Bentel Security ECHO User manual

Bentel Security
Bentel Security CALL-R24 User manual

Bentel Security
Bentel Security Base-2 User guide

Bentel Security
Bentel Security Wave/WSB User manual

Bentel Security
Bentel Security LADY-PI User manual