CONNECTIONS
The control panel alarm command may be as-
signed to the +N terminal or -A terminal. Use of
the +N terminal is advised, as it is equipped with
a wire cutting protection. The +N termianl of the
BENTEL control panels is directly compatible
with the +N terminal of the siren. In fact, when in
standby status, the +N terminal of BENTEL con-
trol panels have a 13.8 V tension, which fails
when the control panel generates alarm status. If
such a terminal is not available on the control
panel in use, use the free contacts of the alarm
relay, as illustrated in figure 1A. If -A is used as
an alarm command, it must be connected to the
terminal on the control panel which closes to
earth in the event of alarm, as illustrated in figure
1B.
In each case, between the +N terminal board
and the siren earth a 13.8 V tension
(min. 0.6 A) is required, this maintains the
standby battery level. Other connections on
the terminal board, depend on the selected
function mode for siren tamper.
AUTOMATIC METHOD (FIG. 3A)
This is the functional method set by the manufac-
turer (jumper J2 and J3 connected).The mi-
croswitches are connected to the siren logic that,
in the event of tamper generate an alarm, inde-
pendent of the status of the +N and -A terminals.
The alarm ceases 40 seconds after the closure
of both microswitches or at the most, after 7 min-
utes (maximum alarm-time). With this function
mode, the control panel does not acknowledge
tamper status, therefore, there is no signalling on
the terminal and no activation of other connected
alarm devices (such as the telephone dialler,
supplementary siren etc.).
NORMAL METHOD 1 (FIG. 3B)
If control panel acknowledgement of tamper status
is required, removal of the J3 jumper is necessary
as well as the closure of the control panel tamper
line on the siren S terminal. In fact, this is closed to
ground, when in standby status, whilst is discon-
nected when one of the microswitches is open (fig.
2A). In this case, the maximum alarm time is 7 min-
utes (max. alarm-time) or less (timeout set on the
control panel).
NORMAL METHOD 2 (FIG. 3C)
If control panel acknowledgement of tamper
status is required, but the control panel tamper
line closes on a device that is not the siren
(e.g. Bentel Electronic key), it is necessary to
disconnect jumpers J2 and J3, present on the
board. In this way, the tamper microswitches
are no longer connected to the siren ground
(fig. 2B), therefore, connect terminal S and S2
to the control panel tamper line. The alarm
timeout is that set on the control panel (maxi-
mum 7 minutes).
Fig. 1 - Activation modes. Fig. 2 - Antitamper microswitches diagrams.