1 WARNINGS AND SAFETY
b The boilers manufactured in our factories are checked even in
the smallest details in order to protect users and installers against
possible injury. After working on the product, qualied personnel
must check the electrical wiring, in particular the stripped part of
leads,whichmustnotprotrudefromtheterminalboardandavoiding
possible contact with live parts of the leads themselves.
b This installer and user manual constitutes an integral part of the
product:make sure they arealways kept with theappliance, even
if it is transferred to another owner or user, or moved to another
heatingsystem.Incaseoflossordamage,pleasecontactyourlocal
TechnicalAssistanceServiceforanewcopy.
b Thisboilermayonlybeinstalledandservicedbypersonnelqualied
in accordance with current regulations.
b The installer must instruct the user about the operation of the
applianceandaboutessentialsafetyregulations.
b Thisboilermustonlybeusedfortheapplicationitwasdesignedfor.
Themanufactureracceptsno liabilitywithinor withoutthecontract
for any damage caused to people, animals and property due to
installation,adjustmentandmaintenanceerrorsortoimproperuse.
b After removing the packaging, make sure the content is in good
condition and complete. Otherwise, contact the dealer from whom
youpurchasedtheappliance.
b The safety valve outlet must be connected to a suitable collection
and venting system. The manufacturer declines all liability for any
damage caused due to any intervention carried out in the safety
valve.
b Thesealofthecondensatedrainageconnectionlinemustbesecure,
andthelinemustbefullyprotectedagainsttheriskoffreezing(e.g.
byinsulatingit).
b Checkthattherainwaterdrainagechanneloftheuegasestting
and the relative connection pipe are free of obstructions.
b Disposeofallthepackagingmaterialsinthesuitablecontainersat
the corresponding collection centres.
b Dispose of waste by being careful not to harm human health and
without employing procedures or methods which may damage the
environment.
b Attheendofitslife,theproductshouldbenotbedisposedofassolid
urbanwaste,butratheritshouldbehandedovertoadifferentiated
waste collection centre.
b Duringinstallation,informtheuserthat:
- intheeventofwaterleaks,thewatersupplymustbeshutoffand
theTechnicalAssistanceCentremustbecontactedimmediately
- periodically check that the operating pressure of the hydraulic
system is comprised between 1 and 1.5 bar. If it is not, request
thepromptinterventionoftheTechnicalAssistanceCentreorelse
professionallyqualiedpersonnel.
b Iftheboilerisnotusedforalongperiodoftime,itisrecommended
to perform the following operations:
- turnthemainapplianceswitchandthemainsystemswitchto“off”
- closethefuelandwatervalvesfortheheatingsystem
- emptytheheatingcircuitifthereistheriskoffreezing
b Boiler maintenance must be carried out at least once a year; this
shouldbebookedinadvancewiththeTechnicalAssistanceCentre
toensurethenecessarysafetystandards.
Forsafetyreasons,pleaserememberthat:
a Theapplianceisnottobeusedbychildrenorunassistedpeoplewith
disabilities.
a Itisforbiddentotouchtheappliancewhilebarefootorifpartsofyour
bodyarewet.
a It is forbidden to activate electric devices or appliances such as
switches,household appliancesand so onif younotice a smellof
fuelorunburnedfuel.Inthiscase:
- ventilatetheroombyopeningthedoorsandwindows;
- close the fuel shut-off device;
- requestthepromptinterventionoftheTechnicalAssistanceCentre
orelseprofessionallyqualiedpersonnel.
a Anytechnicalorcleaningoperationisforbiddenbeforedisconnecting
theappliance from themain power supplyby turning thesystem’s
mainswitchto“OFF”andthemainswitchoftheboilerto“OFF”.
INSTALLATION MANUAL
EN ENGLISH
a Do not modify the safety or adjustment devices without the
manufacturer’sauthorisationandpreciseinstructions.
a It is prohibited to pull, detach or twist the electrical cables coming
from the appliance even if it is disconnected from the mains power
supply.
a Avoid blocking or reducing the size of the air vent openings in
the installation room, do not leave inammable containers and
substances in the room where the appliance is installed.
a Do not leave ammable containers and substances in the room
where the device is installed.
a Itisforbiddentodispersethepackagingmaterialintheenvironment
andleaveitwithinchildren’sreachasitmay be a potentialsource
ofdanger.Itmustbedisposedinaccordancewiththepresentlaw.
a The condensate drain outlet must be turned towards the drain outlet
avoidingtheformationofmoresiphons.
a Nevercarryoutanyworkonthegasvalve.
2
DESCRIPTION
The EXCLUSIVE boilershaveanewACC(ActivateCombustionControl)
system. This new control system, developed by Beretta, ensures
functionality,efciencyandlowemissionsunderanyconditions.
TheACCsystemusesanionisationsensorimmersedintheburnerame,
whose information allows the control board to operate the gas valve that
regulatesthefuel.
This sophisticated control system provides the auto-regulation of the
combustion,sothereisnoneedforaninitialcalibration.TheACCsystemis
abletoadapttheboilertooperatewithdifferentgascompositions,different
outlet pipes lengths and different altitudes (within the specied design
limits).
TheACCsystemcanalsoperformanauto-diagnosticoperationthatlocks
outtheburnerbeforethepermittedupperemissionlimitisexceeded.
EXCLUSIVE isatypeCcondensingwall-hungboilerthatisabletooperate
as follows:
- CASE A: only heating with no external storage tank connected. The
boilerdoesnotprovidedomestichotwater.
- CASE B: only heating with an external storage tank managed by a
thermostat: inthiscondition,theboilerdelivershotwatertothestorage
tankwheneverademandismadebytherelativethermostat.
- CASE C: only heating with an external storage tank (accessory kit
availablebyrequest)managedbyatemperatureprobefortheproduction
ofDHW.Ifthestoragetankisnotsuppliedbyourcompany,makesure
thattherelativeNTCprobehasthefollowingcharacteristics:10kOhmat
25°C,B3435±1%.
Depending on the fume discharge accessory used, it is classied in
categories B23P;B53P; C13,C13x; C33,C33x; C43,C43x; C53,C53x;
C63,C63x;C83,C83x;C93,C93x.
In B23P conguration (when installed indoors), the appliance cannot
be installed in bedrooms, bathrooms, showers or where there are open
replaceswithoutaproperairow.Theroomwheretheboilerisinstalled
musthaveproperventilation.Detailedrequirementsfortheinstallation of
theue,thegaspipingandforventilatingtheroom,canbefoundinUNI
7129-7131.
IncongurationC,theappliancecanbeinstalledinanytypeofroom(there
arenolimitationsduetoventilationconditionsorroomvolume).
3 INSTALLATION
3.1 Cleaning the system and characteristics of the
water
Inthecaseofanewinstallationorreplacementoftheboiler,itisnecessary
tocleantheheatingsystem.
To ensure the device works well, top up the additives and/or chemical
treatments (e.g. anti-freeze liquids, lming agents, etc.) and check the
parameters in the table are within the values indicated.
PARAMETERS UM HEATING CIRCUIT
WATER FILLING WATER
pH value 7-8 -
Hardness °F -<15
Appearance - clear
Fe mg/kg 0,5 -
Cu mg/kg 0,1 -
b Before installation, wash all system piping carefully in order to
removeanyresiduesthatmayimpairtheoperationoftheappliance.