Bestway SALUSPA VANCOUVER AIRJET PLUS User manual

OWNER’S MANUAL EN
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_封面

IMPORTANT SAFETY INSTRUCTIONS pg 003
PRE-SETUP CHECK LIST pg 007
INSTALLATION pg 009
SET-UP INSTRUCTION IN WINTER pg 009
USING THE SPA pg 013
MAINTENANCE pg 017
DISASSEMBLY AND STORAGE pg 019
TROUBLESHOOTING pg 021
ERROR CODES pg 023
VISIT BESTWAY YOUTUBE CHANNEL
FOR INSTRUCTION VIDEOS
PLEASE VISIT:
BESTWAYCORP.COM/SUPPORT
WE SUGGEST NOT TO RETURN
THE PRODUCT TO THE STORE
QUESTIONS? PROBLEMS?
MISSING PARTS?
For FAQ, Manuals, Videos Or
spare Parts, Please Visit
bestwaycorp.com/support
V
i
s
i
t
w
w
w
.
b
e
s
t
w
a
y
c
o
r
p
.
c
o
m
/
s
u
p
p
o
r
t
f
o
r
h
e
l
p
CONTENTS
2
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

IMPORTANT SAFETY INSTRUCTIONS
WARNING
IMPORTANT SAFETY INSTRUCTIONS
When using this electrical equipment, basic safety precautions should always be
followed, including the following:
READ AND FOLLOW ALL
INSTRUCTIONS.
WARNING – To reduce the risk of injury, do not permit children to use this product
unless they are closely supervised at all times.
A wire connector is provided on this unit to connect a minimum 6 AWG (13.3 mm
2
)
solid copper conductor between this unit and any metal equipment, metal enclosures
of electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit.
DANGER – Risk of injury.
a) Replace damaged cord immediately.
b) Do not bury cord.
c) Connect to a grounded, grounding type receptacle only.
WARNING – This product is provided with a ground-fault circuit-interrupter integrated
with the power plug at the end of the cord. The GFCI must be tested before each
use. With the product operating, push the test button on the GFCI and the product
should not operate. Push the reset button on the GFCI and the product should now
operate normally. When the product fails to operate in this manner, there is a ground
current flowing indicating the possibility of an electrical shock. Disconnect the power
until the fault has been identified and corrected.
DANGER – Risk of Accidental Drowning. Extreme caution must be exercised to
prevent unauthorized access by children. To avoid accidents, ensure that children
cannot use this spa unless they are supervised at all times.
DANGER – Risk of Injury. The suction fittings in this spa are sized to match the
specific water flow created by the pump. Should the need arise to replace the suction
fittings or the pump, be sure that the flow rates are compatible. Never operate spa if
the suction fittings are broken or missing. Never replace a suction fitting with one
rated less than the flow rate marked on the original suction fitting.
DANGER – Risk of Electric Shock. Install at least 5 feet (1.5 m) from all metal
surfaces. As an alternative, a spa may be installed within 5 feet of metal surfaces if
each metal surface is permanently connected by a minimum 6 AWG (13.3 mm
2
) solid
copper conductor to the wire connector on the terminal box that is provided for this
purpose.
DANGER – Risk of Electric Shock. Do not permit any electric appliance, such as a
light, telephone, radio, or television, within 5 feet (1.5 m) of a spa.
WARNING – To reduce the risk of injury:
a) The water in a spa should never exceed 104°F (40°C). Water temperatures
between 100°F (38°C) and 104°F (40°C) are considered safe for a healthy adult.
Lower water temperatures are recommended for young children and when spa
use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing fetal
damage during the early months of pregnancy, pregnant or possibly pregnant
women should limit spa water temperatures to100°F (38°C).
c) Before entering a spa, the user should measure the water temperature with an
accurate thermometer since the tolerance of water temperature-regulating devices
varies.
d) The use of alcohol, drugs, or medication before or during spa use may lead to
unconsciousness with the possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high blood
pressure, circulatory system problems, or diabetes should consult a physician
before using a spa.
f) Persons using medication should consult a physician before using a spa since
some medication may induce drowsiness while other medication may affect heart
rate, blood pressure, and circulation.
WARNING: TO AVOID ELECTRIC SHOCK, DO NOT USE THE SPA WHEN IT IS
RAINING.
WARNING: Water attracts children; Always attach a spa cover after each use.
WARNING: TO REDUCE THE RISK OF INJURY: Never add water that is higher than
104°F (40°C) into the Spa.
CONSULT YOUR PHYSICIAN FOR
RECOMMENDATIONS.
CAUTION:
We strongly recommend not to unfold and inflate the spa if the ambient temperature
is below 59°F(15°C). We suggest inflating the spa indoors, and then continuing set
up outdoors. If the outdoor temperature is lower than 42.8°F(6°C), the spa heater
must always be on. In this mode, the Freeze Shield™ system can keep the internal
temperature between 42.8°F(6°C) and 50°F(10°C) to prevent damage, such as water
freezing in the pipes or the circulation system.
IMPORTANT:
If the Freeze Shield™ system isn’t working, alarms will pop up on the
spa. Be sure to check the status of your spa if the outdoor temperature is below
42.8°F(6°C). In case of a long-term absence from home when there is a risk of
temperatures falling below 42.8°F(6°C), we strongly suggest disassembling the spa
and storing it following the storage procedure.
CAUTION: Do not use the spa alone.
CAUTION: Always enter and exit the spa slowly and cautiously. Wet surfaces are
slippery.
CAUTION: To avoid damage to the pump, the spa must never be operated unless
the spa is filled with water.
CAUTION: Immediately leave spa if the user feels uncomfortable or sleepy.
NOTE: Please examine equipment before use. Notify Bestway
®
at the customer
service address listed on this manual for any damaged or missing parts at the time of
purchase. Verify that the equipment components represent the model that you had
intended to purchase.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with
Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause
undesired operation of the device.
Any changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
To satisfy FCC / IC RF exposure requirements, a separation distance of 20 cm or more
should be maintained between the antenna of this device and persons during device
operation.
To ensure compliance, operations at closer than this distance is not recommended.
Limited by local law regulations, version for North America does not have region
selection option.
SAVE THESE INSTRUCTIONS
WARNING: CHILDREN SHOULD NOT USE SPAS OR HOT TUBS WITHOUT
ADULT SUPERVISION.
WARNING: DO NOT USE SPAS OR HOT TUBS UNLESS ALL SUCTION GUARDS
ARE INSTALLED TO PREVENT BODY AND HAIR ENTRAPMENT.
WARNING: PEOPLE USING MEDICATIONS AND/OR HAVING AN ADVERSE
MEDICAL HISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A SPA OR
HOT TUB.
WARNING: PEOPLE WITH INFECTIOUS DISEASES SHOULD NOT USE A SPA
OR HOT TUB.
WARNING: TO AVOID INJURY, EXERCISE CARE WHEN ENTERING OR EXITING
THE SPA OR HOT TUB.
WARNING: DO NOT USE DRUGS OR ALCOHOL BEFORE OR DURING THE USE
OF A SPA OR HOT TUB TO AVOID UNCONSCIOUSNESS AND POSSIBLE
DROWNING.
WARNING: PREGNANT OR POSSIBLY PREGNANT WOMEN SHOULD CONSULT
A PHYSICIAN BEFORE USING A SPA OR HOT TUB.
WARNING: WATER TEMPERATURE IN EXCESS OF 38°C (100°F) CAN BE
INJURIOUS TO YOUR HEALTH.
WARNING: BEFORE ENTERING THE SPA OR HOT TUB, MEASURE THE WATER
TEMPERATURE WITH AN ACCURATE THERMOMETER.
WARNING: DO NOT USE A SPA OR HOT TUB IMMEDIATELY FOLLOWING
STRENUOUS EXERCISE.
WARNING: PROLONGED IMMERSION IN A SPA OR HOT TUB CAN BE
INJURIOUS TO YOUR HEALTH.
WARNING: DO NOT PERMIT ELECTRIC APPLIANCES (SUCH AS A LIGHT,
TELEPHONE, RADIO, OR TELEVISION) WITHIN 1.5 M OF THIS SPA OR HOT
TUB.
CAUTION: MAINTAIN WATER CHEMISTRY IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
3
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

WARNING
IMPORTANT SAFETY INSTRUCTIONS
When using this electrical equipment, basic safety precautions should always be
followed, including the following:
READ AND FOLLOW ALL
INSTRUCTIONS.
WARNING – To reduce the risk of injury, do not permit children to use this product
unless they are closely supervised at all times.
A wire connector is provided on this unit to connect a minimum 6 AWG (13.3 mm
2
)
solid copper conductor between this unit and any metal equipment, metal enclosures
of electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit.
DANGER – Risk of injury.
a) Replace damaged cord immediately.
b) Do not bury cord.
c) Connect to a grounded, grounding type receptacle only.
WARNING – This product is provided with a ground-fault circuit-interrupter integrated
with the power plug at the end of the cord. The GFCI must be tested before each
use. With the product operating, push the test button on the GFCI and the product
should not operate. Push the reset button on the GFCI and the product should now
operate normally. When the product fails to operate in this manner, there is a ground
current flowing indicating the possibility of an electrical shock. Disconnect the power
until the fault has been identified and corrected.
DANGER – Risk of Accidental Drowning. Extreme caution must be exercised to
prevent unauthorized access by children. To avoid accidents, ensure that children
cannot use this spa unless they are supervised at all times.
DANGER – Risk of Injury. The suction fittings in this spa are sized to match the
specific water flow created by the pump. Should the need arise to replace the suction
fittings or the pump, be sure that the flow rates are compatible. Never operate spa if
the suction fittings are broken or missing. Never replace a suction fitting with one
rated less than the flow rate marked on the original suction fitting.
DANGER – Risk of Electric Shock. Install at least 5 feet (1.5 m) from all metal
surfaces. As an alternative, a spa may be installed within 5 feet of metal surfaces if
each metal surface is permanently connected by a minimum 6 AWG (13.3 mm
2
) solid
copper conductor to the wire connector on the terminal box that is provided for this
purpose.
DANGER – Risk of Electric Shock. Do not permit any electric appliance, such as a
light, telephone, radio, or television, within 5 feet (1.5 m) of a spa.
WARNING – To reduce the risk of injury:
a) The water in a spa should never exceed 104°F (40°C). Water temperatures
between 100°F (38°C) and 104°F (40°C) are considered safe for a healthy adult.
Lower water temperatures are recommended for young children and when spa
use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing fetal
damage during the early months of pregnancy, pregnant or possibly pregnant
women should limit spa water temperatures to100°F (38°C).
c) Before entering a spa, the user should measure the water temperature with an
accurate thermometer since the tolerance of water temperature-regulating devices
varies.
d) The use of alcohol, drugs, or medication before or during spa use may lead to
unconsciousness with the possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high blood
pressure, circulatory system problems, or diabetes should consult a physician
before using a spa.
f) Persons using medication should consult a physician before using a spa since
some medication may induce drowsiness while other medication may affect heart
rate, blood pressure, and circulation.
WARNING: TO AVOID ELECTRIC SHOCK, DO NOT USE THE SPA WHEN IT IS
RAINING.
WARNING: Water attracts children; Always attach a spa cover after each use.
WARNING: TO REDUCE THE RISK OF INJURY: Never add water that is higher than
104°F (40°C) into the Spa.
CONSULT YOUR PHYSICIAN FOR
RECOMMENDATIONS.
CAUTION:
We strongly recommend not to unfold and inflate the spa if the ambient temperature
is below 59°F(15°C). We suggest inflating the spa indoors, and then continuing set
up outdoors. If the outdoor temperature is lower than 42.8°F(6°C), the spa heater
must always be on. In this mode, the Freeze Shield™ system can keep the internal
temperature between 42.8°F(6°C) and 50°F(10°C) to prevent damage, such as water
freezing in the pipes or the circulation system.
IMPORTANT:
If the Freeze Shield™ system isn’t working, alarms will pop up on the
spa. Be sure to check the status of your spa if the outdoor temperature is below
42.8°F(6°C). In case of a long-term absence from home when there is a risk of
temperatures falling below 42.8°F(6°C), we strongly suggest disassembling the spa
and storing it following the storage procedure.
CAUTION: Do not use the spa alone.
CAUTION: Always enter and exit the spa slowly and cautiously. Wet surfaces are
slippery.
CAUTION: To avoid damage to the pump, the spa must never be operated unless
the spa is filled with water.
CAUTION: Immediately leave spa if the user feels uncomfortable or sleepy.
NOTE: Please examine equipment before use. Notify Bestway
®
at the customer
service address listed on this manual for any damaged or missing parts at the time of
purchase. Verify that the equipment components represent the model that you had
intended to purchase.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with
Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause
undesired operation of the device.
Any changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
To satisfy FCC / IC RF exposure requirements, a separation distance of 20 cm or more
should be maintained between the antenna of this device and persons during device
operation.
To ensure compliance, operations at closer than this distance is not recommended.
Limited by local law regulations, version for North America does not have region
selection option.
SAVE THESE INSTRUCTIONS
WARNING: CHILDREN SHOULD NOT USE SPAS OR HOT TUBS WITHOUT
ADULT SUPERVISION.
WARNING: DO NOT USE SPAS OR HOT TUBS UNLESS ALL SUCTION GUARDS
ARE INSTALLED TO PREVENT BODY AND HAIR ENTRAPMENT.
WARNING: PEOPLE USING MEDICATIONS AND/OR HAVING AN ADVERSE
MEDICAL HISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A SPA OR
HOT TUB.
WARNING: PEOPLE WITH INFECTIOUS DISEASES SHOULD NOT USE A SPA
OR HOT TUB.
WARNING: TO AVOID INJURY, EXERCISE CARE WHEN ENTERING OR EXITING
THE SPA OR HOT TUB.
WARNING: DO NOT USE DRUGS OR ALCOHOL BEFORE OR DURING THE USE
OF A SPA OR HOT TUB TO AVOID UNCONSCIOUSNESS AND POSSIBLE
DROWNING.
WARNING: PREGNANT OR POSSIBLY PREGNANT WOMEN SHOULD CONSULT
A PHYSICIAN BEFORE USING A SPA OR HOT TUB.
WARNING: WATER TEMPERATURE IN EXCESS OF 38°C (100°F) CAN BE
INJURIOUS TO YOUR HEALTH.
WARNING: BEFORE ENTERING THE SPA OR HOT TUB, MEASURE THE WATER
TEMPERATURE WITH AN ACCURATE THERMOMETER.
WARNING: DO NOT USE A SPA OR HOT TUB IMMEDIATELY FOLLOWING
STRENUOUS EXERCISE.
WARNING: PROLONGED IMMERSION IN A SPA OR HOT TUB CAN BE
INJURIOUS TO YOUR HEALTH.
WARNING: DO NOT PERMIT ELECTRIC APPLIANCES (SUCH AS A LIGHT,
TELEPHONE, RADIO, OR TELEVISION) WITHIN 1.5 M OF THIS SPA OR HOT
TUB.
CAUTION: MAINTAIN WATER CHEMISTRY IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
4
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

WARNING
IMPORTANT SAFETY INSTRUCTIONS
When using this electrical equipment, basic safety precautions should always be
followed, including the following:
READ AND FOLLOW ALL
INSTRUCTIONS.
WARNING – To reduce the risk of injury, do not permit children to use this product
unless they are closely supervised at all times.
A wire connector is provided on this unit to connect a minimum 6 AWG (13.3 mm
2
)
solid copper conductor between this unit and any metal equipment, metal enclosures
of electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit.
DANGER – Risk of injury.
a) Replace damaged cord immediately.
b) Do not bury cord.
c) Connect to a grounded, grounding type receptacle only.
WARNING – This product is provided with a ground-fault circuit-interrupter integrated
with the power plug at the end of the cord. The GFCI must be tested before each
use. With the product operating, push the test button on the GFCI and the product
should not operate. Push the reset button on the GFCI and the product should now
operate normally. When the product fails to operate in this manner, there is a ground
current flowing indicating the possibility of an electrical shock. Disconnect the power
until the fault has been identified and corrected.
DANGER – Risk of Accidental Drowning. Extreme caution must be exercised to
prevent unauthorized access by children. To avoid accidents, ensure that children
cannot use this spa unless they are supervised at all times.
DANGER – Risk of Injury. The suction fittings in this spa are sized to match the
specific water flow created by the pump. Should the need arise to replace the suction
fittings or the pump, be sure that the flow rates are compatible. Never operate spa if
the suction fittings are broken or missing. Never replace a suction fitting with one
rated less than the flow rate marked on the original suction fitting.
DANGER – Risk of Electric Shock. Install at least 5 feet (1.5 m) from all metal
surfaces. As an alternative, a spa may be installed within 5 feet of metal surfaces if
each metal surface is permanently connected by a minimum 6 AWG (13.3 mm
2
) solid
copper conductor to the wire connector on the terminal box that is provided for this
purpose.
DANGER – Risk of Electric Shock. Do not permit any electric appliance, such as a
light, telephone, radio, or television, within 5 feet (1.5 m) of a spa.
WARNING – To reduce the risk of injury:
a) The water in a spa should never exceed 104°F (40°C). Water temperatures
between 100°F (38°C) and 104°F (40°C) are considered safe for a healthy adult.
Lower water temperatures are recommended for young children and when spa
use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing fetal
damage during the early months of pregnancy, pregnant or possibly pregnant
women should limit spa water temperatures to100°F (38°C).
c) Before entering a spa, the user should measure the water temperature with an
accurate thermometer since the tolerance of water temperature-regulating devices
varies.
d) The use of alcohol, drugs, or medication before or during spa use may lead to
unconsciousness with the possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high blood
pressure, circulatory system problems, or diabetes should consult a physician
before using a spa.
f) Persons using medication should consult a physician before using a spa since
some medication may induce drowsiness while other medication may affect heart
rate, blood pressure, and circulation.
WARNING: TO AVOID ELECTRIC SHOCK, DO NOT USE THE SPA WHEN IT IS
RAINING.
WARNING: Water attracts children; Always attach a spa cover after each use.
WARNING: TO REDUCE THE RISK OF INJURY: Never add water that is higher than
104°F (40°C) into the Spa.
CONSULT YOUR PHYSICIAN FOR
RECOMMENDATIONS.
CAUTION:
We strongly recommend not to unfold and inflate the spa if the ambient temperature
is below 59°F(15°C). We suggest inflating the spa indoors, and then continuing set
up outdoors. If the outdoor temperature is lower than 42.8°F(6°C), the spa heater
must always be on. In this mode, the Freeze Shield™ system can keep the internal
temperature between 42.8°F(6°C) and 50°F(10°C) to prevent damage, such as water
freezing in the pipes or the circulation system.
IMPORTANT:
If the Freeze Shield™ system isn’t working, alarms will pop up on the
spa. Be sure to check the status of your spa if the outdoor temperature is below
42.8°F(6°C). In case of a long-term absence from home when there is a risk of
temperatures falling below 42.8°F(6°C), we strongly suggest disassembling the spa
and storing it following the storage procedure.
CAUTION: Do not use the spa alone.
CAUTION: Always enter and exit the spa slowly and cautiously. Wet surfaces are
slippery.
CAUTION: To avoid damage to the pump, the spa must never be operated unless
the spa is filled with water.
CAUTION: Immediately leave spa if the user feels uncomfortable or sleepy.
NOTE: Please examine equipment before use. Notify Bestway
®
at the customer
service address listed on this manual for any damaged or missing parts at the time of
purchase. Verify that the equipment components represent the model that you had
intended to purchase.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with
Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause
undesired operation of the device.
Any changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
To satisfy FCC / IC RF exposure requirements, a separation distance of 20 cm or more
should be maintained between the antenna of this device and persons during device
operation.
To ensure compliance, operations at closer than this distance is not recommended.
Limited by local law regulations, version for North America does not have region
selection option.
SAVE THESE INSTRUCTIONS
WARNING: CHILDREN SHOULD NOT USE SPAS OR HOT TUBS WITHOUT
ADULT SUPERVISION.
WARNING: DO NOT USE SPAS OR HOT TUBS UNLESS ALL SUCTION GUARDS
ARE INSTALLED TO PREVENT BODY AND HAIR ENTRAPMENT.
WARNING: PEOPLE USING MEDICATIONS AND/OR HAVING AN ADVERSE
MEDICAL HISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A SPA OR
HOT TUB.
WARNING: PEOPLE WITH INFECTIOUS DISEASES SHOULD NOT USE A SPA
OR HOT TUB.
WARNING: TO AVOID INJURY, EXERCISE CARE WHEN ENTERING OR EXITING
THE SPA OR HOT TUB.
WARNING: DO NOT USE DRUGS OR ALCOHOL BEFORE OR DURING THE USE
OF A SPA OR HOT TUB TO AVOID UNCONSCIOUSNESS AND POSSIBLE
DROWNING.
WARNING: PREGNANT OR POSSIBLY PREGNANT WOMEN SHOULD CONSULT
A PHYSICIAN BEFORE USING A SPA OR HOT TUB.
WARNING: WATER TEMPERATURE IN EXCESS OF 38°C (100°F) CAN BE
INJURIOUS TO YOUR HEALTH.
WARNING: BEFORE ENTERING THE SPA OR HOT TUB, MEASURE THE WATER
TEMPERATURE WITH AN ACCURATE THERMOMETER.
WARNING: DO NOT USE A SPA OR HOT TUB IMMEDIATELY FOLLOWING
STRENUOUS EXERCISE.
WARNING: PROLONGED IMMERSION IN A SPA OR HOT TUB CAN BE
INJURIOUS TO YOUR HEALTH.
WARNING: DO NOT PERMIT ELECTRIC APPLIANCES (SUCH AS A LIGHT,
TELEPHONE, RADIO, OR TELEVISION) WITHIN 1.5 M OF THIS SPA OR HOT
TUB.
CAUTION: MAINTAIN WATER CHEMISTRY IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
5
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

1. Indoor Installation:
Be aware of special requirements if you install the spa indoors.
•
Humidity is a natural side effect with SaluSpa installation. First determine the effects of moisture
on exposed wood, paper, etc. in the proposed location. To minimize these effects, it is best to
provide plenty of ventilation to the selected area. An architect can help determine if more
ventilation is needed.
2. Outdoor Installation:
•
During filling, draining or when in use, water may spill out of the spa. Therefore the SaluSpa
should be installed near a floor drain.
•
Do not leave the spa surface exposed to direct sunlight for long periods of time.
SELECTED LOCATION
IMPORTANT:
Due to the combined weight of the SaluSpa, water, and users, it is extremely
important that the surface where the SaluSpa is installed is smooth, flat, level
and capable of supporting the weight for the entire time the SaluSpa is installed (not on the carpet or
other similar material). If the SaluSpa is placed on a surface which does not meet these
requirements, any damage caused by improper support is not covered under the manufacturer’s
warranty. It is the responsibility of the SaluSpa owner to assure the integrity of the surface at all times.
NOTE:
The warning label must be posted near your spa in a readable position during using your spa.
1. Take out the warning label from the accessory kit.
2. Carefully peel the warning label.
3. Affix the warning label.
To order the warning label, please contact your local Bestway After Sales Service.
ASSEMBLY: THE PROVIDED WARNING LABEL
WARNING
REDUCE THE RISK OF ELECTROCUTION
1. NEVER PLACE AN ELECTRIC APPLIANCE WITHIN 5 FEET OF SPA.
REDUCE THE RISK OF CHILD DROWNING
1. SUPERVISE CHILDREN AT ALL TIMES.
2. ATTACH SPA COVER AFTER EACH USE.
REDUCE THE RISK OF OVERHEATING
1. CHECK WITH A DOCTOR BEFORE USE IF PREGNANT, DIABETIC, IN
POOR HEALTH, OR UNDER MEDICAL CARE.
2. EXIT IMMEDIATELY IF UNCOMFORTABLE, DIZZY, OR SLEEPY. SPA HEAT
CAN CAUSE HYPERTHERMIA AND UNCONSCIOUSNESS.
3. SPA HEAT IN CONJUNCTION WITH ALCOHOL, DRUGS, OR MEDICATION
CAN CAUSE UNCONSCIOUSNESS.
WHEN PREGNANT,
SOAKING IN HOT WATER FOR LONG PERIODS
CAN HARM YOUR FETUS. MEASURE WATER
TEMPERATURE BEFORE ENTERING.
1. DO NOT ENTER SPA IF WATER IS HOTTER THAN 100°F(38°C)
2. DO NOT STAY IN SPA FOR LONGER THAN 10 MINUTES.
6
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

PARTS CHECKS
Please examine equipment before use.
Notify Bestway® customer service of any
damaged or missing parts at the time of
purchase. Verify that the equipment
components represent the model that you
had intended to purchase. For reference
please use the diagrams below.
VANCOUVER AIRJET PLUS S100204 (60028)
— 61" x 24" / 1.55 m x 60 cm
04
P05220
1 06
P05343
1
11
P05320
4
03
P05222
1
09
P05524
2
14
P05344
1
01
P05218
1
07
P05345
1 12
/
2
02
P05340
1
08
P03052
1
13
P61726ASS18
1
05
P05482
1
10
P00217
1
15
P05346
1 16
P6609ASS16
1 17
/
1
2
3 - 5 2-3ºF/h
1.0-1.5ºC/h
320 gal/h
1,211 L/h
0.48-0.69Bar
7-10PSI
213 gal
804 L
1,833 Lb
831 kg
PRE-SETUP CHECK LIST
7
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

MILAN AIRJET PLUS S100204 (60030)
— 77" x 28" / 1.96 m x 71 cm
04
P03427
1
09
P00217
1
15
P6609ASS16
1 16
P05767
1
06
P05343
1
11
/
2
03
P05213
1
14
P05346
1
01
P05209
1
07
P05345
1 12
P61726ASS18
1
02
P05340
1
08
P05524
2
13
P61727ASS18
1
05
P05341
1
10
P05320
6
2
4 - 6 2-3ºF/h
1-1.5ºC/h
320 gal/h
1,211 L/h
0.08Bar
1.2PSI
242 gal
916 L
2,103 Lb
954 kg
8
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

It is important to follow these suggestions if you are setting up the spa during the winter period. This will
prevent damage to the PVC material and extend the life of your product drastically.
•
If the ambient temperature is below 50°F(10°C), we suggest keeping the package indoor where the
temperature is above 59°F(15°C) for at least 2h before inflation. This will make the spa liner more
flexible and easier to set up.
•
Open the package in the same room where the temperature is above 59°F(15°C), and inflate the spa
using the spa heater.
•
Position the spa liner outdoor in the desired position, connect the spa heater and fill with water.
Important: The water temperature used to fill the spa must be above 42.8°F(6°C), otherwise when
you begin to operate with the spa heater, the E03 alarm will appear.
Important: If the Freeze Shield™ system isn’t working, alarms will pop up on the spa. Be sure to check
the status of your spa if the outdoor temperature is below 42.8°F(6°C). In case of a long-term absence
from home when there is a risk of temperatures falling below 42.8°F(6°C), we strongly suggest
disassembling the spa and storing it following the storage procedure. When you assemble the spa, the
automatic warm function will turn on. In this condition, the spa can be used when the temperature is
lower than 42.8°F(6°C).
INSTALLATION
< 50°F(10°C)
>59°F(15°C)
>59°F(15°C)
SET-UP
INSTRUCTION
IN WINTER
9
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

4
123
P6609ASS16
5 min
0.48-0.69Bar
7-10PSI
VANCOUVER
5
7 8
6
2
2
10
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

9 10 11
max
min
MAX.
MIN.
GFCI Test
IMPORTANT: RISK OF ELECTRIC SHOCK. THE GFCI MUST BE TESTED
BEFORE TURNING ON THE PUMP EACH TIME.
WARNING: The GFCI plug must be tested before each use to avoid risk of electric shock.
WARNING: Before inserting plug into a power outlet, make sure the current rate of the power outlet is
suitable for the pump.
WARNING: Do not use the pump if this test fails. For assistance, please visit the support section on our
website, www.bestwaycorp.com.
WARNING: Using an extension lead or multi plug adaptor with the spa heater can cause the plug to
overheat, causing damage to the equipment and surrounding items. The spa is a class I electrical
appliance and must be connected directly to a grounded socket. It is recommended to only use a socket
which is resistant to humidity and capable of high power loading. Regularly check the plug and socket
for signs of damage before using the spa – do not use the spa if the plug or socket is damaged. If you
are unsure about the quality of the electrical supply, please consult a qualified electrician before use.
NOTE: When inflating, you will notice that air will be expelled from the area where the air hose connects
to the pump, this is normal for technique requirements.
NOTE: Do not use an air compressor to inflate the pool.
NOTE: Do not drag the pool on rough ground as this may cause damage to the pool liner.
NOTE: Inflation time for reference only.
1. Plug the GFCI into a power outlet, the indicator turns red.
2. Press the test button, the indicator turns off.
3. Press the reset button, the indicator turns red and the spa is ready for use.
When inflating, you will notice that air will be expelled from
the area where the air hose connects to the pump, this is
normal for technique requirements.
Important: Don't cover the holes on the base of the
inflation hose. This operation will over inflate the liner and
damage the structure.
Do not use an air compressor to inflate the pool.
Do not drag the pool on rough ground as this may cause
damage to the pool liner.
Inflation time for reference only.
11
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

Air Valve Check (for spa with quick inflation/deflation valve)
Always check the air valve carefully before inflation to ensure there is not an air leak.
If the air valve is loose, use the provided wrench to fasten the air valve following
these steps:
With one hand, hold the backside of the air valve from the inner side of the spa wall
and turn the wrench clockwise.
NOTE:
1. Do not over tighten.
2. Do not adjust the air valve connector when the spa is in use.
12
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

USING THE SPA
A
B
E
G
C
D
I
J
H
F
Hyperthermia occurs when the internal temperature of the body reaches a level
several degrees above the normal body temperature of 98.6°F(37°C). The symptoms
of hyperthermia include an increase in the internal temperature of the body,
dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include
failure to perceive heat, failure to recognize the need to exit spa or hot tub,
unawareness of impending hazard, fetal damage in pregnant women, physical
inability to exit the spa or hot tub, and unconsciousness resulting in the danger of
drowning.
WARNING – The use of alcohol, drugs, or medication can greatly increase the risk of
fatal hyperthermia.
WARNING: WATER TEMPERATURE IN EXCESS OF 100°F(38°C) CAN BE
INJURIOUS TO YOUR HEALTH.
A. LOCK/UNLOCK BUTTON: The pump has a 5-minute auto-lock, this
light will turn on. To lock or unlock the pump, place a finger over the
lock/unlock button for 3 seconds.
B. POWER-SAVING TIMER BUTTON: Designed to help avoid wasting
power by setting the time and duration of the heating cycle for the spa.
This way, you can enjoy your spa at the time you desire, without needing
to leave the heater on at all times.
STEP 1: Set the heating duration
1. Press the button unit the LED starts to flash.
2. Press the or button to adjust the heating duration (From 1-999 hours).
3. Press the button again to confirm the heating duration.
STEP 2: Set the number of hours FROM NOW when the heater will activate
1. After setting the heating duration, the LED starts to flash.
2. Press the or button to adjust the hours until time of activation (From 0-999 hours).
3. Press button again or simply touch nothing for 10 seconds to confirm the setting. The
LED will light steadily, and the countdown to heater activation will begin.
To modify the timer settings: Press the button and use the or button to adjust.
Cancel the setting: Press the button for 2 seconds.
NOTE: After setting, the screen flashes the current temperature and time alternately.
NOTE: Timer adjustment (amount of time with the heater ON) may be set from 1 to 999 hours;
Reservation time adjustment (the number of hours FROM NOW when the heater will begin to
function) may be set from 0 to 999 hours. If the timer is set at 0 hour, the heating system will
activate immediately.
Note that the timer is one time per use - the user sets the duration of the heating cycle, and
how many hours from now the heating cycle begins. The timer does NOT repeat until reset.
C. HEAT BUTTON: Use this button to activate the heating system. When
the light above the heat button is red, the heating system is activated.
When the light is green, the water is at the set temperature and the
heating system is at rest.
NOTE: If the heating system is activated the filtration system will
automatically start.
NOTE: After turning off the heating system the filtration system will
continue to operate.
NOTE: If the spa heater is on when the water temperature is below
42.8°F(6ºC), the heating system will warm the water until 50°F(10ºC)
automatically.
13
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

NOTE: The WATER HEATER rate may change in the conditions below:
• When the outdoor temperature is below 59°F(15°C).
• If the cover is not in position when the heating function is activated.
C. HEAT BUTTON: Use this button to activate the heating system. When
the light above the heat button is red, the heating system is activated.
When the light is green, the water is at the set temperature and the
heating system is at rest.
NOTE: If the heating system is activated the filtration system will
automatically start.
NOTE: After turning off the heating system the filtration system will
continue to operate.
NOTE: If the spa heater is on when the water temperature is below
42.8°F(6ºC), the heating system will warm the water until 50°F(10ºC)
automatically.
D. MASSAGE SYSTEM BUTTON: Use this button to activate the
massage system, which has a 30-minute auto-shutoff feature. The light
above the Massage System Button displays red when activated.
IMPORTANT: Do not run the Massage system when the cover is
attached. Air can accumulate inside the spa and cause irreparable
damage to the cover and bodily harm.
NOTE: Heat and massage system work together to create a warm
massage experience.
E/G. TEMPERATURE ADJUSTMENT BUTTONS: Pressing the
Temperature Increase or Decrease buttons will cause the LED to flash.
When it is flashing you can adjust to the desired temperature setting. If
you hold these buttons down the values will rapidly increase or decrease.
The new and desired temperature setting will remain on the LED display
for 3 seconds to confirm the new value.
NOTE: The default temperature is 95°F(35°C).
NOTE: Temperature adjustment ranges from 68°F(20°C) to 104°F(40°C).
I. WATER FILTER BUTTON: This button turns the filter pump on and off.
The light above the Water Filter Button displays red when activated.
F. ON/OFF BUTTON: Press this button for 2 seconds to active the control
panel buttons and the light turns to green. Press this button for 2 seconds
to turn off all currently activated functions.
H. CELSIUS/FAHRENHEIT TOGGLE: The temperature can be displayed
in either Fahrenheit or Celsius.
J. Wi-Fi activation. For more information, please refer to Wi-Fi operation
instructions.
POWER-SAVING TIMER LED:
This flashing LED means you are setting the heating duration. The light will
be on when the heating function starts to work.
This flashing LED means you are setting the number of hours FROM NOW
when the heater will activate. When the light is on, the Power-Saving
Timer function is set.
NOTE: To display the current water temperature, run the filter system for at least a
minute.
The water temperature as tested by an external thermometer may vary from the
temperature as displayed on the spa panel by as much as approximately 35.6°F(2°C).
14
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

NOTE: The WATER HEATER rate may change in the conditions below:
• When the outdoor temperature is below 59°F(15°C).
• If the cover is not in position when the heating function is activated.
Ambient Temperature
50ºF(10ºC)
59ºF(15ºC)
68ºF(20ºC)
77ºF(25ºC)
86ºF(30ºC)
Water Temperature
50ºF(10ºC)
59ºF(15ºC)
68ºF(20ºC)
77ºF(25ºC)
86ºF(30ºC)
Set Temperature
104ºF(40ºC)
104ºF(40ºC)
104ºF(40ºC)
104ºF(40ºC)
104ºF(40ºC)
Heating Duration
32 h
26 h
20 h
14 h
9 h
IMPORTANT
To reach 104°F(40°C), the heating duration required is based on the starting water
temperature and ambient temperature, the data below is purely for reference. To
display the current water temperature, run the filter system for at least a minute.
Power Rate Massage Tube Blower Heat Element Water Pump
11.3A at 20ºC 0.7A
110-120V AC,
60Hz, Single Phase
12A at 20ºC 6.5A
• Be sure to cover the spa with the spa
cover whenever the heating function is
activated. Leaving the spa uncovered
will increase the heating duration
required.
• When the spa is assembled with water,
do not switch off the spa heater if the
temperature is lower than 42.8°F(6ºC).
WINTER USE INSTRUCTIONS
•
You can keep the spa on during winter when the temperature is lower than
42.8°F(
6°C
)
. The Freeze Shield™ system automatically keeps the water temperature
between
42.8°F(
6°C
)
and
50°F(
10°C
)
, and it will prevent the water from freezing.
Important:
If the water temperature is below
42.8°F(
6°C
)
, the spa heater must always
be on. In this mode, the Freeze Shield™ system can keep the internal temperature
between
42.8°F(
6°C
)
and
50°F(
10°C
)
to prevent damage, such as water freezing in the
pipes or the circulation system.
Important:
If the Freeze Shield™ system isn’t working, alarms will pop up on the spa.
Be sure to check the status of your spa if the outdoor temperature is below
42.8°F(
6°C
)
. In case of a long-term absence from home when there is a risk of
temperatures falling below
42.8°F(
6°C
)
, we strongly suggest disassembling the spa
and storing it following the storage procedure.
•
Any damage as a result of using the spa in these conditions is the responsibility of the
customer. Do not use the spa when the ambient temperature reaches 14°F(-10°C).
NOTE: To display the current water temperature, run the filter system for at least a
minute.
The water temperature as tested by an external thermometer may vary from the
temperature as displayed on the spa panel by as much as approximately 35.6°F(2°C).
15
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

Bestway Smart HubTM Connection Guide
Download Bestway Smart HubTM App from the Apple Store/Google Play Store.
NOTE: The device can only be connected to one mobile phone at a time. If you
need to connect to another mobile phone, press the Wi-Fi button for 3 seconds.
When the indicator light flashes slowly, the device will clear the connection
information from the previous mobile phone. Please follow the instructions to
connect the new phone to the pump.
NOTE: Before connecting the app to the pump, please make sure that your mobile
device is close to the pump and the Wi-Fi signal is strong.
NOTE: This app supports Android 7.0 and above or iOS 10.0 and above.
NOTE: The device only supports distributing 2.4G network, but does not support
5G network.
NOTE: It is not recommended to use public Wi-Fi. When connected to public Wi-Fi,
you may have issues with the input verification codes during log-in.
STEP 1: Ensure your mobile device is connected to Wi-Fi.
STEP 2:Plug in the spa. Press and hold the
Wi-Fi button
on your pump for 3 seconds to begin syncing. The
Wi-Fi indicator light should be flashing slowly.
NOTE:
Ensure the spa is plugged in and test the PRCD.
STEP
3
:
Open the
Bestway Smart HubTM
App on your mobile device. Follow the step-by-step guide to sync
with your app.
○ Login or register your account.
○ Once the Wi-Fi network has been found, input your Wi-Fi password.
○ Change to the Wi-Fi service to: BW-LayZSPA-xxx Password: 123456789
(Andriod system will skip this step and start the connection process directly)
○ Go back to the app, and wait until the connection process is finished.
Now you can control your SaluSpa by both mobile device and control panel.
Disconnect
Press the button for 3 seconds until the Wi-Fi indicator flashes slowly.
Sharing function
Note: Only one person can scan the Shared QR code generated each time. If you want to share it with other
devices, you must generate a new Shared QR code each time. The Shared QR code expires after 15 minutes.
The sharing function can only be used when users are in the same country.
16
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

Cover Maintenance
The cover shall be cleaned inside and out periodically using a suitable solution that
includes adequate disinfection (e.g. 10 mg/l of Free Chlorine).
Filter Cartridge Maintenance
To ensure your spa water stays clean, check and clean your filter cartridges every
day follow the steps below.
NOTE: We recommend changing your filter cartridges every week or, if the filter
cartridges remain soiled and discolored, they should be replaced.
CAUTION: You must ensure the pump is unplugged before beginning spa
maintenance to avoid risk of injury or death.
MAINTENANCE
Adding Air: Your spa will require additional air to be added from time to time.
Changes in temperature from day to night will change the pressure in the spa and
may cause a certain amount of deflation. Please follow the assembly instructions and
inflate to the accurate pressure needed.
When you need to use the pump for inflation, please block the hoses to prevent
water from escaping, then disconnect the pump, screw on the cap (P00217) to avoid
water coming out from the air pipe.
Filter Set
Filter Cartridge
Water Maintenance
Many pollutants in the water settle on surfaces below the water line. These
pollutants can cause bacterial, algal or fungal growth. It is recommended that spas
are cleaned as regularly as necessary. After a time, tenacious stains or biofilms may
develop on the accessible surfaces below the water line or high concentrations of
salts or unwanted reaction by-products may also occur. Depending on hygienic
condition, cleanliness, visibility, odour, debris and stains, it is recommended to
change the water completely and clean/disinfect the spa. When emptying the spa,
the regulations and the instructions for draining the water shall be observed.
Keeping your spa water clean and chemically balanced is necessary. Simply
cleaning the filter cartridge is not enough for proper maintenance, we recommend
you use pool chemicals to maintain water chemistry and chlorine or bromine tablets
(do not use granules) with the chemical dispenser.
Water quality will be directly related to frequency of use, number of users and
overall maintenance of the spa. The water should be changed every
3 days if there is no chemical treatment being performed with the water.
It is highly recommended to use tap water for spa filling to minimize the influence of
unwanted content, such as minerals. Barefoot areas and relaxing areas shall be
cleaned as well. No cleaning water may flow into the spa or spa water cycle. The
dirt and cleaning agents shall be rinsed carefully to drain in the spa surround.
Note: We recommend you take a shower before using your SaluSpa, as cosmetic
products, lotions, and other residues on the skin can quickly degrade water
quality.To use the chemical dispenser, please follow the below instruction.
P00217
P05524
17
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

NOTE: Remove the chemical dispenser from spa when the spa is in use.
IMPORTANT: After performing chemical maintenance and before using the spa, use
a test kit (not included) to test the water chemistry. We recommend maintaining your
water as below table.
Important: Add chemical liquid in small doses and in
the center of the pool avoid directly contact of the
chemical with the spa surface, the direct contact of
chemical with spa material will damage the material
and discolored the surface.
NOTE: Damage resulting from chemical imbalance is not covered by the warranty.
Pool chemicals are potentially toxic and should be handled with care. There are
serious health risks from chemical vapors and the incorrect labeling and storage of
chemical containers. Please consult your local pool supply retailer for more
information about chemical maintenance. Pay close attention to the chemical
manufacturer’s instructions. spa damage resulting from misuse of chemicals and
mismanagement of spa water is not covered by the warranty.
Important: Over usage of chemical will discolored the printing and all points of the
spa material, in worse case damage the structure of the spa liner.
pH
7.4-7.6
Total Alkalinity
80-120ppm
Free Chlorine
2-4ppm
Using chemical tablets (not included):
Using chemical liquid (not included):
Water Maintenance
Many pollutants in the water settle on surfaces below the water line. These
pollutants can cause bacterial, algal or fungal growth. It is recommended that spas
are cleaned as regularly as necessary. After a time, tenacious stains or biofilms may
develop on the accessible surfaces below the water line or high concentrations of
salts or unwanted reaction by-products may also occur. Depending on hygienic
condition, cleanliness, visibility, odour, debris and stains, it is recommended to
change the water completely and clean/disinfect the spa. When emptying the spa,
the regulations and the instructions for draining the water shall be observed.
Keeping your spa water clean and chemically balanced is necessary. Simply
cleaning the filter cartridge is not enough for proper maintenance, we recommend
you use pool chemicals to maintain water chemistry and chlorine or bromine tablets
(do not use granules) with the chemical dispenser.
Water quality will be directly related to frequency of use, number of users and
overall maintenance of the spa. The water should be changed every
3 days if there is no chemical treatment being performed with the water.
It is highly recommended to use tap water for spa filling to minimize the influence of
unwanted content, such as minerals. Barefoot areas and relaxing areas shall be
cleaned as well. No cleaning water may flow into the spa or spa water cycle. The
dirt and cleaning agents shall be rinsed carefully to drain in the spa surround.
Note: We recommend you take a shower before using your SaluSpa, as cosmetic
products, lotions, and other residues on the skin can quickly degrade water
quality.To use the chemical dispenser, please follow the below instruction.
Important: Don't use granulate tablet or throw the tablet directly in the water, the
chemical will deposit on the bottom and damage the material and discolored the PVC.
C
o
n
-
l
o
i
n
5
18
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

DISASSEMBLY AND STORAGE
DRAINING THE SPA
1. 2.
3. 4.
5.
NOTE: Dry the spa pool.
P00217
NOTE: Lift up the spa when there is
only a little water left. Damages to
the handles are not covered under
the warranty.
NOTE: Dry the spa pool
2. 3. 4.
6.
1. 5.
8.
Only for Drop stitch Spa
19
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英

CLEANING THE SPA
Detergent residues and dissolved solids from bathing suits and chemicals may build
up on the spa walls. Use soap and water to clean the walls and rinse thoroughly.
NOTE: DO NOT use hard brushes or abrasive cleaners.
Make sure the spa and pump are completely dry. This is essential to extend the life of
the spa. We recommend using the pump to blow dry the spa, pump and pipes.
Remove the filter sets and discard the used filter cartridges. Re-attach the two
stopper caps onto the spa’s inlet and outlet valves. It is recommended you store the
spa in its original package in a warm [ above 59°F(15°C) ] and dry place.
DEFLATION
Your spa is equipped with a deflation function to remove all the air from inside the
chamber to make it easier to pack and store.
REPAIR
For PVC part.
If the spa is torn or punctured, use the provided underwater adhesive repair patch.
1. Clean area to be repaired.
2. Carefully peel patch.
3. Press patch over area to be repaired.
4. Wait 30 seconds before inflation.
For Tritech PVC material.
If the spa is torn or punctured, use the provided PVC repair patch and glue (not included) following these steps:
1. Clean and dry area to be repaired.
2. Cut the provided PVC patch to appropriate size.
3. Use glue (not included) to coat the one side of the newly cut patch. Make sure the glue is evenly distributed.
4. Wait for 30 seconds and then place the cut patch with glue over the damaged area.
5. Smooth out any bubbles of air that may be trapped underneath, and press firmly for two minutes.
6. The product is once again ready for use. Repeat this process should further leaks occur.
7. Wait 30 minutes before inflation.
Screw valve
Quick inflation/deflation valve
P61727ASS18
P61726ASS18
P05344
P61726ASS18
20
303021246561_14.0x21.0cm_60028,60030_美规AirJetPlus说明书21季_英
This manual suits for next models
2
Table of contents
Languages:
Other Bestway Spa Accessories manuals
Popular Spa Accessories manuals by other brands

Spa Natural
Spa Natural SN14 SAFETY PRECAUTIONS AND USER MANUAL

Zodiac
Zodiac Nature2 Express owner's manual

glass 1989
glass 1989 MAWI Installation & maintenance manual

Tellur
Tellur TLL331261 user manual

OAKWORKS
OAKWORKS PerformaLift Series Instruction & maintenance manual

Leisure Concepts
Leisure Concepts Covermate III installation guide