2
For the initial test tap water is ok and no nutrients are needed. (For an actual grow we
suggest distilled or filtered water).
2. Verify the reservoir level sensor and pressurize the system.
On the mobile app, place the AeroKit in maintenance mode using the button called
“Maintenance Mode” from the kit status screen.
Under the section, Procedures select the option “Prime System (Auto Valve model).”
If your readings appear to be outside of a margin of 5% error you can add additional
water that should stabilize the reading.
3 Gal ≈ 35%
4 Gal ≈ 47 %
Max fill is 8.5Gal = 100%
. Pressurize the system
Press the “OK” button on the lower half of the screen to the right of number 1.
The system will automatically run the pumps to flush and prepare for system
pressurization. This will take one minute.
Press the “OK” button on the lower half of the screen to the right of number 3.
The system will automatically load up the accumulator tank and pressurize to ≈ 100 psi.
This will take about 2 to 3 minutes.
Once pressurization completes, exit the screen using the “Back” button and exit from
maintenance mode using the check ✓ icon.
Launch the 24 hour initial baseline test
We highly suggest that you perform a 24 hour initial baseline test. This test will run a specific
grow plan designed to fully engage all of your AeroKit’s system.
On the mobile app, select the “Load A Grow Plan” button from the AeroKit status screen.
Select the Grow Plan called, 24 hour baseline test