EPIC 10 User Manual P/N 5400321 Rev. H
Founded in 1986, BIOLASE, Inc. specializes in lasers for medicine
and dentistry that feature proprietary and patented technologies for
minimally invasive surgeries, reducing pain and improving clinical
results.
Only BIOLASE combines the leading laser technology – continuously
improved through ongoing clinical R&D and engineering – with
unmatched training, practice integration support and service.
BIOLASE leads the global dental laser market with over 21,000 lasers in
use today and the most complete family of dental lasers – from diode
lasers to the most advanced all-tissue laser, the WaterLase iPlus™.
About BIOLASE
BIOLASE, Inc.
4 Cromwell
Irvine, CA 92618 USA
949.361.1200
888.424.6527
biolase.com
MT Promedt Consulting GmbH
Altenhofstrasse 80
D-66386 St. Ingbert/Germany
+49 6894 581020
mt-procons.com
Copyright © 2014 BIOLASE, Inc. All rights reserved. EPIC, iLase, ezLase, ezTip, LaserWhite, Deep Tissue Handpiece,
ComfortPulse, WaterLase, and WaterLase iPlus are either trademarks or registered trademarks of BIOLASE,
Incorporated in the United States and/or other countries. All other trademarks are property of their registered
owners. Subject to change without notice.
User Manual
EPIC 10 User Manual P/N 5400321 Rev. H
Made in the USA
5400321 Rev. H User Manual, EPIC 10_Cover.indd 1 9/11/2014 1:26:21 PM

TABLE OF CONTENTS
Table of Contents....................................................................................................................... 1
Introduction................................................................................................................................ 4
1.Packaging............................................................................................................................... 5
1.1 System Parts List.............................................................................................................. 5
1.2 Facility Requirements....................................................................................................... 5
2. Equipment Description........................................................................................................... 6
2.1 General ............................................................................................................................ 6
2.2 Base Console................................................................................................................... 6
2.3 Control Panel.................................................................................................................... 6
2.4 Surgical Delivery System.................................................................................................. 7
2.5 Fiber Optic Connection..................................................................................................... 7
2.6 Single-Use Tips................................................................................................................ 8
2.7 Surgical Handpiece Assembly.........................................................................................10
2.8 Whitening/Contour Handpiece (Optional Accessory) .......................................................11
2.9 Deep Tissue Handpiece (Optional Accessory).................................................................12
3. Safety....................................................................................................................................13
3.1 Precautions .....................................................................................................................13
3.2 Safety Instructions...........................................................................................................13
3.3 Safety Features...............................................................................................................14
Energy Monitor ..................................................................................................................14
System Monitor..................................................................................................................14
Power Switch.....................................................................................................................15
Access Key Code...............................................................................................................15
Control Button....................................................................................................................15
Wireless Footswitch...........................................................................................................15
Remote Interlock................................................................................................................16
Emergency Stop ................................................................................................................17
Functional Display..............................................................................................................17
3.4 Safety Classification........................................................................................................17
4. Operation Instructions...........................................................................................................18
4.1 System setup...................................................................................................................18
Epic™10 User Manual pg. 1 5400321 Rev H

4.2 Operation - Turn on the Epic 10.......................................................................................19
4.3 Settings Screen...............................................................................................................20
4.4 Pairing the Footswitch to the Laser console.....................................................................20
4.5 Control Button .................................................................................................................22
4.6 Entering READY or STANDBY Modes ............................................................................22
4.7 READY Mode..................................................................................................................22
4.8 Wireless Footswitch.........................................................................................................23
4.9 Peak Power Display ........................................................................................................23
4.10 Pulse Mode Selection....................................................................................................23
4.11 Using the Epic 10 Touch Screen Display......................................................................25
4.12 Procedures Button.........................................................................................................26
4.13 Turn the Laser Console Off............................................................................................26
5. Specifications........................................................................................................................27
5.1 General ...........................................................................................................................27
5.2 Electrical..........................................................................................................................27
5.3 Laser...............................................................................................................................27
5.4 Other Light Sources.........................................................................................................28
6. Contraindications, Warnings & Precautions ..........................................................................29
6.1 Contraindications.............................................................................................................29
6.2 Warnings and Precautions...............................................................................................29
Prescription Statement.......................................................................................................29
Eyewear.............................................................................................................................29
Anesthesia.........................................................................................................................29
Adjacent Structures............................................................................................................29
Suction...............................................................................................................................30
Plume Removal..................................................................................................................30
Clinical Use........................................................................................................................30
Training..............................................................................................................................30
7. Clinical Applications..............................................................................................................31
7.1 Introduction......................................................................................................................31
7.2 Indications for Use...........................................................................................................31
7.3 Soft Tissue Surgery and Other Dental Use......................................................................32
Tip Initiation: Parameters and Method (Not required if using pre-initiated tips)...................32
Epic™10 User Manual pg. 2 5400321 Rev H

Pre-programmed Settings for Dental Procedures...............................................................33
7.4 Table of Pre-Programmed Settings..................................................................................34
7.5 Teeth Whitening Procedure.............................................................................................35
7.6 Pain Therapy...................................................................................................................35
Pain Therapy – Adverse Effects.........................................................................................36
Pain Therapy – Warnings and Precautions........................................................................36
Recommended Use...........................................................................................................37
Using the Deep Tissue Handpiece.....................................................................................37
Using the Whitening/Contour Handpiece ...........................................................................37
8. Maintenance .........................................................................................................................38
8.1 Daily Maintenance...........................................................................................................38
8.2 Cleaning and Sterilization Procedures.............................................................................38
Cleaning and Disinfecting Instructions-Surgical Handpiece, Reusable Fiber Optic Cable ..38
Manual Cleaning of the Surgical Handpiece:......................................................................39
Steam Sterilization for Surgical Handpiece, Single Use Tips..............................................39
Disinfecting the Whitening/Contour Handpiece ..................................................................40
Disinfecting the Deep Tissue Handpiece............................................................................40
8.3 Installing/Replacing the Console Battery Pack.................................................................40
8.4 Changing the Wireless Footswitch Batteries....................................................................41
8.5 Transportation.................................................................................................................42
8.6 Storage............................................................................................................................42
9. Calibration.............................................................................................................................43
10. Software Specification.........................................................................................................43
11. Troubleshooting ..................................................................................................................43
APPENDIX A – Tip Guide.........................................................................................................46
APPENDIX B – Labeling...........................................................................................................47
APPENDIX C – Safety Precautions for Lithium-Ion Battery Packs ............................................51
APPENDIX D – Accessories.....................................................................................................54
APPENDIX E – Electromagnetic Compatibility..........................................................................55
APPENDIX F – Wireless Equipment Compliance Statement.....................................................59
Epic™10 User Manual pg. 3 5400321 Rev H

INTRODUCTION
The Epic™ 10 diode laser is a surgical and therapeutic device at the cutting edge of technology,
designed for a wide variety of oral soft tissue procedures and dental whitening, as well as for
use in providing temporary relief of minor pain.
The Epic 10 utilizes a solid state diode as a semiconductor source for invisible infrared
radiation. The energy is delivered to the treatment site via flexible fiber connected at one end to
the laser source and the other end to the Handpiece. Various types of single use, disposable
tips are designed and optimized for different applications. The device is activated by means of
a wireless footswitch.
This is a prescription device that is indicated for professional use only by licensed medical and
dental practitioners. The use of this device requires proper clinical and technical training. This
manual provides instructions for those professionals that have completed the appropriate
training.
When used and maintained properly, the Epic 10 will prove a valuable addition to your practice.
Please contact BIOLASE Customer Service at 1-800-321-6717 in the U.S. for any service
needs. If you are located outside the USA, please contact your BIOLASE-authorized distributor.
Epic™10 User Manual pg. 4 5400321 Rev H

1.PACKAGING
1.1 SYSTEM PARTS LIST
The Epic 10 laser system includes the following:
1. Laser Console (lithium ion battery pack already installed)
2. Screen Protectors box (Peel-off clear screen cover - qty. 30)
3. Delivery System (installed)
4. Assorted Surgical Tips
5. Surgical Handpiece box (contains two (2) Surgical Handpieces)
6. Three (3) pairs of protective laser eyewear (two (2) pairs of doctor safety glasses,
one (1) pair of darker patient safety glasses)
7. DC power supply and power cord (one (1) US and one (1) International)
8. User Manual
9. Welcome Kit (Welcome Letter, BIOLASE store information, Quick Setup Guide,
Guide to Online Training & Product Registration Card, Limited Warranty Information)
10. Laser Warning Sign
11. Tip Initiation Kit
12. Remote Interlock cable
13. Philips-head screwdriver (for installing Footswitch batteries)
14. Footswitch
15. AAA batteries (2)
NOTE:
The laser ships with the lithium ion battery pack already installed.
NOTE:
Use proper care when transporting the unit. Refer to Section 8 in this User
Manual for instructions.
WARNING:
No modification of this equipment is allowed.
1.2 FACILITY REQUIREMENTS
Electrical Supply (100-240V ~):
1.5A, 50/60Hz
Environmental Requirements:
Temperature: 20-25 ºC
Humidity: 15-95%, Non-condensing
Epic™10 User Manual pg. 5 5400321 Rev H

2. EQUIPMENT DESCRIPTION
2.1 GENERAL
The Epic 10 system consists of three components:
● Base Console
● Delivery System
● Wireless Footswitch
2.2 BASE CONSOLE
The Console has a Display Panel (Touch Screen and Control Button) in front. It can be powered
by an external mains power supply or an internal replaceable lithium ion battery pack, 14.4V,
2.9 Ah.
2.3 CONTROL PANEL
ITEM ITEM DESCRIPTION
CONTROL
Button Activates the controls and display; places
the unit into STANDBY or READY mode.
LED
Indicator
Amber indicates unit is in STANDBY
mode.
Green indicates unit is in READY
mode.
Blinking green indicates the emission
of laser power.
Blinking blue indicates pairing
between the footswitch and laser
console is active
Figure 2.1: Control Panel (Front View)
LED Indicator
LED Indicator
Control Button
Fiber Storage Channel
Epic™10 User Manual pg. 6 5400321 Rev H

2.4 SURGICAL DELIVERY SYSTEM
NOTE:
All fiber optic cables, Handpieces & tips are shipped non-sterile.
The Epic 10 Delivery System with surgical Handpiece consists of:
•Re-useable Fiber Optic Assembly
•Re-useable Surgical Handpiece (Figures 2.9)
•Disposable Tips (Appendix A)
NOTE:
The fiber optic cable is detachable from the console. The Handpiece is a Re-usable
accessory and will require cleaning and sterilization prior to each patient treatment.
Tips are intended for single-use only and must be disposed of after each patient use.
Proper tip disposal in a biohazard medical waste Sharps container is required. Tips
must be steam sterilized prior to use. For instructions on cleaning and sterilization of
the Handpiece and tips Refer to Section 8.
2.5 FIBER OPTIC CONNECTION
The Epic10 ships with the fiber optic cable already attached.
To disconnect the fiber optic cable from the laser console, make sure the laser console is
turned off and the cable is completely unwound from the console base, grab the fiber optic
access plug and slowly pull it straight back from the optical access port (Figure 2.3).
To re-install the fiber optic cable, make sure the laser console is turned off. The fiber optic
cable is attached to the console by inserting the optical access plug (Figure 2.2) into the optical
access port (Figure 2.3).
For storage, wind the cable in the fiber storage channel around the base of the console in a
counterclockwise direction (Figure 2.1).
CAUTION:
Do not connect or disconnect the fiber while the laser console is turned on. Only
connect or disconnect the fiber when the laser console is turned off.
NOTE:
Make sure you hear the fiber optic “click” into place; if you do not hear it “click,”
remove the fiber optic and reinstall it.
CAUTION: Do not bend the fiber optic at a sharp angle, as it is can break. Make sure it is
not caught or pinched between the housing and the fiber optic access plug.
Epic™10 User Manual pg. 7 5400321 Rev H

Figure 2.2: Fiber Optic Access Plug
Figure 2.3: Optical Access Port
2.6 SINGLE-USE TIPS
The tips are single-use accessories and are provided in three core diameters: 200μm, 300μm,
and 400μm, in different lengths (see Appendix A).
CAUTION:
Tips are single-use only to avoid cross-contamination and are designed to
withstand only a single sterilization cycle; they must be disposed of after use in
a biohazard medical waste Sharps container.
Always visually inspect the tip prior to use to make sure it is free of debris or
damage.
CAUTION:
Be aware that the metal/plastic cannula on the tips may become hot during
use. Avoid contact of the cannula with any tissue.
To connect the tip, first connect the handpiece to the fiber, then insert the tip firmly into the
distal end of the handpiece as far as it will go, and tighten by turning clockwise (Figure 2.4).
Bend the metal cannula according to the specific procedure requirements (Figure 2.7).
Remove the fiber tip by twisting the tip counterclockwise (Figure 2.5).
NOTE:
To provide proper laser operation, do not connect tips when the handpiece is
disconnected from the fiber.
Epic™10 User Manual pg. 8 5400321 Rev H

Tip Assembly
Figure 2.4: Insert the fiber tip into the handpiece (only when the handpiece is connected to the fiber) and
twist clockwise until snug
Figure 2.5: Remove the fiber Tip by twisting the tip counterclockwise
Correct Bend
Incorrect Bend
Figure 2.6: When installing the tip, make sure it is
seated properly (thread correctly) Figure 2.7: Bending the tip cannula
WARNING:
When the aiming beam is not present or has a significantly asymmetrical shape:
►For tips that require initiation: change the tip
►For tips that do not require initiation: change the tip; press to bypass
initiation requirement.
Epic™10 User Manual pg. 9 5400321 Rev H

2.7 SURGICAL HANDPIECE ASSEMBLY
►To connect the Handpiece to the fiber optic assembly, push the Handpiece on the fiber
shaft until it clicks on and is secured at connected position.
Fiber Shaft Protective Cap
Handpiece
Figure 2.8: Connecting the Handpiece to the fiber optic assembly
Figure 2.9: Surgical Handpiece Assembly fully assembled
►Disconnect the handpiece from the fiber optic assembly (Figure 2.10) by
1. Taking the handpiece body in one hand and the shaft in the other,
2. Pushing the two buttons on the Fiber Shaft,
3. Pulling the handpiece with the ring to separate.
Figure 2.10: Disconnect the Handpiece from the fiber optic assembly by pressing both buttons at the
base of the Fiber Shaft
Epic™10 User Manual pg. 10 5400321 Rev H

2.8 WHITENING/CONTOUR HANDPIECE (OPTIONAL ACCESSORY)
NOTE:
The Whitening/Contour Handpiece is reusable and equipped with a disposable non-
sterile protective shield for single patient use. The Handpiece is non-sterile and
requires disinfection before and after each patient treatment. This Handpiece
cannot be sterilized in the autoclave. For disinfection instructions refer to
Section 8.
Always wipe the disposable shield with alcohol prior to use. The disposable shield is
for single-use only to avoid cross-contamination. Dispose of when treatment session
is completed.
Figure 2.11: Whitening/Contour Handpiece
Figure 2.12: Disposable Non-Sterile Shield
The area of Laser Energy Output for the Whitening/Contour Handpiece is 35mm x 8mm =
2.8cm2Spot Size.
To connect the Handpiece to the fiber optic cable, push the Handpiece onto the fiber shaft until
it clicks on and is secured.
To disconnect the Handpiece from the fiber optic assembly:
•Take the Handpiece body in one hand and the shaft in another.
•Press both buttons at the base of the Fiber Shaft.
•Pull the Handpiece from the ring to separate.
Epic™10 User Manual pg. 11 5400321 Rev H

2.9 DEEP TISSUE HANDPIECE (OPTIONAL ACCESSORY)
NOTE:
The Deep Tissue Handpiece is reusable and equipped with a disposable non-sterile
protective shield for single patient use. The Handpiece is non-sterile and requires
disinfection before and after each patient treatment. This Handpiece cannot be
sterilized in the autoclave. For instructions on disinfecting the Handpiece, refer to
section 8.
Always wipe the disposable shield with alcohol prior to use. The disposable shield is
for single-use only to avoid cross-contamination. Dispose of when treatment session
is completed.
Figure 2.13: Deep Tissue Handpiece
Remove Red Cap Dust Cover from the Deep Tissue Handpiece.
The Handpiece is now ready to use.
To remove the Handpiece, press and hold both buttons at the base of the Fiber Shaft and pull
the Handpiece away from the shaft.
Slide Handpiece over shaft until it clicks into place
(Figure 2.14).
Figure 2.14
Place protective shield over the adjustable spacer
(Figure 2.15).
Figure 2.15
Loosen the Lock Ring and set the Spacer at the desired spot size
Detent Location (Figure 2.16). Tighten the Lock Ring.
Figure 2.16
Handpiece
Spacer
Disposable
Shield
Red Cap Dust
Cover
Epic™10 User Manual pg. 12 5400321 Rev H

3. SAFETY
3.1 PRECAUTIONS
Failure to comply with precautions and warnings described in this User Manual may lead to
exposure to dangerous optical radiation sources. Please comply with all safety instructions and
warnings.
3.2 SAFETY INSTRUCTIONS
Follow these safety instructions before and during treatments:
•When the laser is in use, all operatory entrances must be marked with an appropriate
warning sign (one (1) included).
•Do not operate in the presence of explosive or flammable materials. Flammable
anesthetics or oxidizing gases such as nitrous oxide (N2O) and oxygen should be avoided.
Solvents of adhesives and flammable solutions used for cleaning and disinfecting should
be allowed to evaporate before laser is used. Attention should also be drawn to the danger
of ignition of endogenous gases.
All persons present in the operatory must wear protective laser eyewear.
NOTE:
For replacement or additional protective laser eyewear, please contact BIOLASE.
CAUTION:
Periodically inspect laser eyewear for pitting and cracking.
LASER
WARNING:
Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
WARNING:
Do not use this unit if you suspect it of functioning improperly or other than
described herein.
CAUTION:
This unit has been designed and tested to meet the requirements of
electromagnetic, electrostatic, and radio frequency interference standards.
However, the possibility of electromagnetic or other interference may still exist.
Relocating the device may help to eliminate the interference.
CAUTION: Always ensure that the proper laser parameters are set before the Epic 10 laser
is used in a clinical setting.
Epic™10 User Manual pg. 13 5400321 Rev H

LASER
WARNING:
Always ensure that the protective laser eyewear is appropriate for the
laser wavelength.
•Do not look directly into the beam or at specular reflections.
•Never direct or point the beam at a person’s eyes.
•Always place the system into STANDBY mode (by pressing the Control Button while in
READY mode) before exchanging Handpieces or disposable tips.
•Toggle the ON/OFF switch (located on the rear of the console) to the OFF (O) position
before leaving unit unattended.
LASER
WARNING:
Do not open unit housing at any time. Danger from optical radiation may
exist.
LASER
WARNING:
Do not aim the laser at metallic or reflective surfaces, such as surgical
instruments or dental mirrors. If aimed directly at these surfaces the laser
beam will reflect and create a potential hazard.
CAUTION:
Be aware that the metal / plastic cannula on the tips may become hot during
use. Avoid contact of the cannula with any tissue.
3.3 SAFETY FEATURES
Energy Monitor
The energy monitor measures and verifies power output. Power deviations of more than ± 20%
from the selected value will cause the display to show the error message: “LASER CURRENT
HIGH/LOW”.
The laser console will not operate until the system first clears the error and then goes into
READY mode. If the error message persists, please contact BIOLASE Service at
1-800-321-6717.
System Monitor
The system monitors the emergency stop switch, remote key, wireless footswitch connection,
and output power. An error in any one of these will stop the system. The text display will indicate
the type of error. Operation will not resume until the error is cleared.
Epic™10 User Manual pg. 14 5400321 Rev H

Power Switch
The laser console can be switched ON (I) or OFF (O) using the Power Switch on the back of the
console.
Figure 3.1: Power Switch, DC Power Input, Remote
Interlock Figure 3.2: Power Supply Module with cord
CAUTION:
Use only the Power Supply Module supplied with the Epic 10 laser system
(BIOLASE Part Number 2400129).
Access Key Code
The Access Key Code prevents unauthorized use of the system. It is activated every time the
system is turned on with the Power Switch (refer to Section 4 for code).
NOTE:
Placing the laser in sleep mode by pressing and holding the Control button on the
front panel does not re-set the Access Key Code. Turn the Power Switch OFF (O)
only when the system will not be in use for a long period of time.
Control Button
Once the power switch is set to the ON (I) position, enter the access key code. After setting the
desired parameters for a procedure, press the CONTROL button on the control panel to enter
into READY mode. The aiming beam will illuminate to indicate that the system is ready for use.
Wireless Footswitch
The Epic 10 will not emit laser energy until the user presses down on the Footswitch while the
laser is in READY mode. The footswitch is designed to work using wireless technology.
Power Switch
DC Power
Remote Interlock
Epic™10 User Manual pg. 15 5400321 Rev H

Two (2) AAA batteries are required to power the footswitch (included). (For instructions on how
to replace the footswitch batteries, see Section 4.)
The footswitch is protected by a metal cover. To access, first press down on the cover to
unlatch it. Now the footswitch can be pressed to fire the laser
Figure 3.3: Footswitch
Remote Interlock
This feature allows the laser to be connected to a remote sensor which prevents it from firing
when the sensor is triggered. To install the Remote Interlock, insert the plug (a) at the end of
the connector into the rear of the laser console (Figure 3.1) and attach the two wires (b) at the
other end to a door switch; the laser will stop immediately when the connection to the door
switch is deactivated (when the door is opened).
To override this feature, don’t connect the plug.
Figure 3.4: Remote Interlock Connector
Cover
Footswitch
a
b
Epic™10 User Manual pg. 16 5400321 Rev H

Emergency Stop
Press the red Emergency Laser Stop button to instantly turn off the laser console. The error
screen will display an “Emergency Switch Error” message and the amber LED will begin
flashing. To clear the error, press the Emergency Laser Stop button again; in 2 to 5 seconds the
amber LED will stop flashing and the system will automatically go into STANDBY mode.
Figure 3.5: Emergency Laser Stop (Left Profile View)
Functional Display
The System Color Display with Touch Screen and LED indicators on the control panel show the
functional conditions of the system.
3.4 SAFETY CLASSIFICATION
The following safety classifications are applicable to the device:
•Laser Radiation – Class 4
•Aiming Beam – Class 2
•Type of protections against electrical shock – Class 2
•Degree of protection against electrical shock – Type B Applied Part
•Not protected against water ingress – Ordinary Equipment
•Not suitable for use in presence of flammable anesthetic mixture
•Operation Mode – Continuous Wave and Pulse Mode
•Wireless Footswitch – IPX6
Epic™10 User Manual pg. 17 5400321 Rev H

4. OPERATION INSTRUCTIONS
4.1 SYSTEM SETUP
•Place the unit in a clean, dry, and well-ventilated area.
•Verify power switch is in the OFF (O) position.
•Epic 10 will work using either DC power or the rechargeable battery pack:
oDC Power: Connect the power cord of the power supply to the laser console and plug
into a wall outlet
oRechargeable Battery: The Epic 10 is shipped with the battery pack already installed;
to charge the battery pack, connect the power cord of the DC power supply to the
laser console and plug into a wall outlet. Before first use, fully charge the battery (at
least 3 hours). Once the battery is charged, unplug the power cord from the wall outlet
and the laser console. The laser console will run on battery power alone.
NOTE:
To fully charge the battery, plug the power supply in and then turn the laser console
ON (I) at the Power Switch. The laser console will start to charge and the unit will go
into sleep mode (with the screen off) after 5 minutes; if the power supply is plugged in
but turned OFF (O) at the Power Switch, the battery will still charge, but at a slower
rate.
CAUTION:
Do not connect or disconnect the fiber while the laser console is turned on.
Only connect or disconnect the fiber when the laser console is turned off.
CAUTION:
Do not cover or block ventilation channels. These channels provide an air-flow
path to cool the unit.
CAUTION:
Do not bend the fiber optic at a sharp angle, as it is can break. Make sure it is
not caught or pinched between the housing and the fiber optic access plug.
•Remove protective cap from the end of the fiber shaft (see Figure 2.8).
•Carefully connect the Handpiece to the fiber optic assembly (see Figure 2.9).
•Insert the selected tip and tighten it clockwise until snug (see Figure 2.4).
•Wind any excess fiber optic cable onto the fiber spool counterclockwise around the base
of the console (see Figure 2.1).
•The Handpiece is now ready to use.To store the Handpiece, place it
in the Handpiece holder located at the top of the laser console .
Epic™10 User Manual pg. 18 5400321 Rev H

LASER
WARNING:
Never point the laser at a person’s eyes.
LASER
WARNING:
Never operate the laser without a fiber tip attached.
LASER
WARNING:
All persons present in the operatory must wear protective eyewear when
the laser is in use.
4.2 OPERATION - TURN ON THE EPIC 10
Ensure that the battery has enough charge for operation, or connect the power supply cord to
the power connector on the laser console and plug the cord into a wall outlet.
Turn the Power Switch at the rear of the console to the ON (I) position. The “BIOLASE” logo
screen will appear (Figure 4.1). After three (3) seconds the Epic 10 “Welcome” screen will be
displayed (Figure 4.2).
Figure 4.1
Figure 4.2
Figure 4.3
•Enter the three digit access code using the touch screen. The Access Key Code is 888.
(If the incorrect code is entered, an ‘X’ appears briefly in the window (Figure 4.3); press
the ‘X’ or wait 3 seconds to revert back to the Welcome screen; re-enter the correct
code.
•The system will go to the HOME screen which identifies three procedure categories to
choose from: Soft Tissue, Whitening, Pain Therapy.
Figure 4.4: Home Screen
Wireless Signal
Strength Indicator
Laser Console Battery
Strength Indicator
Settings Button
Epic™10 User Manual pg. 19 5400321 Rev H
Other manuals for epic 10
3
Table of contents
Other Biolase Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Nasco Healthcare
Nasco Healthcare C.H.A.R.L.I.E instruction manual

Handicare
Handicare 1000 Smart XL user manual

DeRoyal
DeRoyal TRANSITION Instructions for use

Diamedica
Diamedica Baby CPAP 10 Instructions for use

NightBalance
NightBalance Sleep Position Trainer manual

Getinge
Getinge MAQUET CRITICAL CARE Service manual

Nidek Medical
Nidek Medical Mark 5 Nuvo Lite Service manual

Iron Bow
Iron Bow vCLINiC CLINiC-VC-10XIR-A01 Installation and user guide

RIDGID
RIDGID SeeSnake MINIPak manual

Richard Wolf
Richard Wolf ENDOCAM Logic HD instruction manual

Abbott
Abbott FreeStyle Libre 3 Getting started

Mizuho
Mizuho MST-7300B Instructions for use