OM-PI1010A E V1.10 May 21, 2015
Page 7
PI1010A
CERTIFICATION LABEL
BLAZE KING CATALYST STOVE - POÊLE À BOIS CATALYTIQUE
Room heater, solid fuel type. / Appareil de chauffage approuvé pour type de carburant solide.
MODEL / MODÈLE: PI1010A
Tested to / Testé pour: UL 1482 / ULC S628-93
CERTIFIED IN BOTH UNITED STATES AND CANADA / CERTIFIÉ POUR LES ÉTATS-UNIS ET LE CANADA
MANUFACTURE DATE
JAN FEB MAR APR MAY JUN
JUL AUG SEP OCT NOV DEC
2015 2016 2017 2018 2019 2020
PREVENT HOUSE FIRES - Install and use only in accordance with Blaze King’s installation and operation instructions. Install and use
in a code complying fireplace only. Contact local building or fire officials about restrictions and installation inspection in your area.
Stainless steel flue liner is required in Canada and recommended in the United States.
PRÉVENTION DES INCENDIES: SI CE POËLE N’EST PAS CORRECTEMENT INSTALLÉ, UN INCENDIE PEUT SE PRODUIRE. POUR
RÉDUIRE LE RISQUE D’INCENDIE, SUIVRE LES INSTRUCTIONS D’INSTALLATIONS. Ce poêle encastrable convient à l’installation pour
l’un ou l’autre: Un foyer construit en usine approuvé à l’UL 127 ou à l’ULC S628-93. Une cheminée de maçonnerie est approuvée avec
un conduit de cheminée isolé. Obligatoire au Canada, recommandé aux États-Unis.
Report # 142-S-05-2
EPA Cert. No 586
SN -
PRINCESS INSERT - Encastrable Princess
#02200515.indd
B
AC
Minimum clearances to combustibles / Espaces minimum requis entre l’appareil à tout matériau combustible
(Measured from insert stove sides and top) / (mesuré à partir des côtés et du dessus de l’encastrable)
A Side to combustible wall / Du côté au mur combustible 7in / 178 mm
B Top to bottom of mantel / Du dessus de l’appareil au -dessous de la tablette de manteau 22in / 559 mm
C Side to combustible facing / Côté à tout revêtement combustible 7in / 178 mm
FLOOR PROTECTION / PROTECTION DU PLANCHER:
A non-combustible floor protection is required for all installations extending 16" (in USA) or 18" (in Canada) in front of the door and extending 8" to either side of the door opening. In
addition to the above requirement that portion of the insert which extends out in front of the fireplace hearth must have a minimum of 1" vertical distance to any combustible material.
Une protection non combustible de plancher est exigée pour toutes les installations se prolongeant de 18’’devant la porte et se prolongeant de 8’’ à l’un ou l’autre des côtés de l’ouverture
de la porte. De plus, la partie du poêle encastrable qui se prolonge au- devant du foyer doit avoir un minimum de 1” de distance verticale de n’importe quel matériau combustible.
FLOOR PROTECTION /
A 8" (203 mm) measured from each side of the fuel loading and ash removal openings /
mesuré de chaque coté de l’ouverture de la porte de chargement et du tiroir de cendre.
B 16" (406 mm) in USA / au USA
B 18" (457 mm) in Canada/ au Canada
Electrical rating: (115 VAC, 60 Hz, 0.58 Amps. Risk of electrical shock. Disconnect power before servicing unit. Do not route power cord in front of or beneath heater). Do not remove
bricks or mortar in masonry fireplace. Do not use grate or elevate fire. INSPECT AND CLEAN CHIMNEY FREQUENTLY.
U.S. ENVIRONMENTAL PROTECTION AGENCY - 2015 Standard - certified to comply with 2015 particulate emission standards (EPA test methods 28 and 5G with an emission-rate of 2.0 g/
hr). Not approved for sale after May 15, 2020. This wood heater needs periodic inspection and repair for proper operation. Consult the owner’s manual for further information. It is against
federal regulations to operate this wood heater in a manner inconsistent with the operating instructions in the owner’s manual, or if the catalytic element is deactivated or removed. *ONLY
OPERATE WITH DOORS CLOSED. Open door to feed fire ONLY. *DO NOT OBSTRUCT COMBUSTION AIR OPENINGS. For Use With Solid Wood Fuel Only - Do not burn other fuels, this may
make the catalyst in the combustor inactive. The performance of the catalytic device or its durability has not been evaluated as part of the certification. Combustor part number: Z4400G.
Provide adequate outside air for combustion. *Replace with only ceramic glass, 5 mm. Thickness.
CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURNS. READ THIS LABEL AND INSTRUCTION MANUAL BEFORE
OPERATING HEATER
ATTENTION: CHAUD LORS DU FONCTIONNEMENT. GARDEZ LES ENFANTS, VÊTEMENTS ET MEUBLES
ÉLOIGNÉS. UN CONTACT AVEC LA PEAU PEUT OCCASIONNER DES BRÛLURES. LIRE CETTE ÉTIQUETTE
ET LES INSTRUCTIONS D’INSTALLATION AVANT DE FAIRE FONCTIONNER CET APPAREIL.
Minimum 1" (25.4mm)
Clearance to combustible
/ Dégagement au matériau
combustible
Non-Combustible spark
protection / surface non
combustible pour protéger
contre les tisons et étincelles
MANUFACTURED IN
USA:
Blaze King Industries
146A Street
Walla Walla, WA. 99362
CANADA:
Valley Comfort Systems
1290 Commercial Way
Penticton, B.C. V2A 3H5
Estimation électrique: (115 VAC, 60 Hz, 0.58 Amps. Risque d’électrocution débrancher le courant avant de réparer l’unité. Ne pas faire courir le fil l’alimentation en avant ou en dessous
de l’appareil de chauffage). Ne pas utiliser une grille pour surélever le feu, établir le feu directement sur les briques dans le fond du poêle. Inspecter et nettoyer VOTRE CHEMINÉE
fréquemment.
AGENCE DE PROTECTION DE L’ENVIRONNEMENT U.S.- STANDARD 2015 – certifie conformément aux normes standard d’émissions de particules 2015 (Méthodes de test 28 et 5G EPA avec
un taux d'émission de 2.0 gr/hre). Non approuvé pour la vente après le 15 mai 2020. Cet appareil de chauffage au bois nécessite des inspections périodiques et des réparations pour un
fonctionnement adéquat. Consulter le manuel du propriétaire pour plus d’informations. Il est contre les règlements fédéraux de faire fonctionner cet appareil de chauffage à l’encontre des
instructions d’utilisation fournies dans le manuel du propriétaire, ou si l’élément catalytique a été enlevé ou désactivé. *UTILISER L’appareil UNIQUEMENT AVEC LES PORTES FERMÉES.
Ouvrir la porte SEULEMENT pour alimenter le feu. *NE PAS OBSTRUER L’ENTRÉE D’AIR DE COMBUSTION. Fournir l'apport d’air extérieur adéquat pour alimenter la combustion. Utiliser
uniquement avec des combustibles solides - ne pas brûler aucun autre combustible, ce qui pourrait désactiver le catalyseur de la chambre à combustion. La performance du catalyseur ou
sa longévité n’a pas été évaluée dans le cadre de la certification. Numéro du catalyseur: Z4400G.* Employer seulement un verre en céramique d’une épaisseur de 5mm si le remplacement
de celui-ci est nécessaire.