Blonder tongue Clearview+ User manual

All Rights Reserved. Specifications subject to change without notice. All trademarks are property of their respective owners.
© Blonder Tongue Labs, Inc. ISO 9001:2015 Certified P/N: 651251900A |Rev: 090920
Quick Guide
HD Transcoder
MPEG-2 / H.264 (AVC) / H.265 (HEVC)
for up to 24 SPTS Programs
Stock # Model Name Description
6557 1 Clearview+ MPEG-2, H.264 (AVC), H.265 (HEVC) to MPEG-2, H.264
(AVC), H.265 (HEVC) HD Transcoder

2Clearview+
Quick Guide
Product Introducon
The Clearview+™is a professional grade video and audio Transcoder in a 1RU form factor, designed to accept up to twenty-
four (24) HD or SD programs simultaneously, using up to 1Gb of data throughput. The unit can accept IP video transport
streams in MPEG-2, H.264, or H.265, and output these IP transport streams to any combinaon of MPEG-2, H.264, and H.265
formats. Product features include transrang capability of specic video bit rates, and specic video resoluons.
The Clearview+hardware-based video compression technology provides superior Transcoding quality at low bit rates, perfect
for Live Linear Broadcasng. The unit was designed to support a wide range of video and audio inputs and outputs, as well
as Dolby® Digital Audio capability to reduce capital and operaonal costs.
Features:
• Stand-alone 1RU Transcoder for the Advanced Transrang of IPTV signals
• SD to HD upscaling or HD to SD downscaling
• IP input up to 24 SPTS MPEG-2, H.264 (AVC), H.265 (HEVC) HD programs
• IP output up to 24 SPTS MPEG-2, H.264 (AVC), H.265 (HEVC) HD programs
• Primary and secondary Audio types: Dolby® Digital AC3, AAC, MPEG1-Layer2 (pass-through only), and MP3
• 1080i to 720p or 720p to 1080i resoluon conversions yields improved compability/bandwidth savings
• 24 front panel Status LEDs, one (1) per each program stream
• Front panel Temperature LED
• Easy-to-use GUI for monitoring and control
Before You Begin
You will nd the following items in the box:
• Clearview+Transcoder (QTY=1)
• Power Cord with IEC C13 line socket and 3-pin Type B NEMA 5 plug (QTY=1)
The Clearview+ is designed to be installed in a standard 19-inch (483 mm) rack (EIA 310-D, IEC 60297, and DIN 41494 SC48D).
To install, secure the unit's front panel to the rack by inserng four (4) machine screws, with cup washers, through the
four (4) mounng holes in the front panel. A 1RU open space is recommended above the unit for venlaon.
Step 1: Setup and Install of the Unit
1
To power the unit up, connect the IEC line cord to the receptacle on the rear panel. Then connect the other end to a
120 VAC power outlet. The input power receptacle is equipped with a fuse-holder and fuse (SLO-BLO, 3.0 Amp, 250V).
2
DO NOT BLOCK THE UNIT'S AIR INTAKE OR AIR DISCHARGE OPENINGS
The Unit performance will be degrated without proper venlaon.
Excessive heat will shorten the life of the unit.
WARNING
For safe and reliable operaon, the ground pin of the power cord must be grounded properly.

3
Clearview+
Quick Guide
Step 2: Connecng to a PC/Laptop
ETHERNET ACCESS:
Local or remote communicaon with the unit is only possible through a GUI-based menu via web browser (Chrome or Firefox
is recommended). Before you can communicate with the unit, you must congure your computer's IP address to be in the
same subnet as the units default IP address. To do so, follow these steps:
Connect one end of the Ethernet cable to the “Control” port on the unit front-panel interface. Connect the other end
of the Ethernet cable to your computer.
The factory default IP address of the Control port is “172.16.70.1”. In order to communicate with the Control port, you
must rst change your computer's IP address.
1
2
The following steps explain how to do this for a computer with Windows 7, Windows 8.x or Windows 10 operang soware:
(a) On your computer, navigate to the “Network and Sharing Center”.
(Note: It can be found using the search box in the Start Menu or for Windows 8.x, the Start Screen)
(b) Once open, click on “Change Adapter Sengs” on le hand side of the window.
(c) Right-click on the “Local Area Connecon”, and then click on the “Properes”.
(d) A dialog box entled “Local Area Connecon Properes” will appear. In this box, double-click on the “Internet
Protocol Version 4 (TCP/IPv4)”.
(e) A dialog box entled “Internet Protocol Version 4 (TCP/IPv4) Properes” will appear. Select the “Use the following
IP address” opon and enter the following addresses:
IP address: 172.16.70.2
Subnet mask: 255.255.255.0
No need to enter a value for the Default Gateway.
Click OK to close the dialog box. Your computer is now ready to communicate with the unit.
IMPORTANT NOTE ON PORT CONFIGURATION
The “Control” port and “IP Video” port should not be congured to be within the same IP subnet.
The “Control” port and “IP Video” port should also not be physically connected to the same network
without proper network segmentaon.
It is possible to access the unit's user interface via the “IP Video” port by using the IP address assigned
to XC1.
Step 3: Login to the Controller
An Ethernet Cable should be connected between your PC and the “Control” port on the unit. Open a Web browser (Chrome
or Firefox recommended) and type hp://172.16.70.1 in to your web browser to view and congure your Clearview+. Enter
the username “Admin” and “pass” as the password and click [LOG IN].

4Clearview+
Quick Guide
IMPORTANT
A reboot is required aer applying a conguraon le.
The user is also able to reboot the unit and upload/download conguraon les. Once downloaded, the sengs can be
applied to the unit or the user can choose to set the unit back to the default factory sengs with a click of a buon.
System Sengs
To change the System and Ethernet Sengs, including unit idencaon and locaon, go to the “System” tab (shown next
page).
This secon provides status messages, temperatures, and fan RPM for the Host system as well as each transcoder used.
The page also features a recent logged message box beneath the main status area which shows the 10 most recent entries
within the Event Log. To see a more in-depth log of event messages, click the “Log” tab located on the right side of the
navigaon menu at the top.
Step 4: Basic Conguraon
System Status
Once you are logged into the unit, you will be presented with the “System Status” page (“Status” tab):
Status Page - Full View
The Ethernet Sengs that can be changed are “IP Address”, “Subnet Mask”, “Default Gateway”, “Primary DNS”, and
“Secondary DNS”. In addion, the network sengs for each transcoder slave are individually congurable.
This secon also allows the user to individually congure the network sengs for each numbered transcode pair (XC1 to XC12).
Click “Apply Sengs” in order to save new or changed sengs.

5
Clearview+
Quick Guide
Step 4: Basic Conguraon (connued)
REMINDER
If the IP Address is changed, the procedure in Step 3 must be repeated using the new IP address in place
of the default IP address in order to re-access the control panel.
System Page - Full View
On this page, the user is able to set up the Video and Audio Pipeline sengs, located on the right side.
The visual representaon of the transcode pipeline on the le side is interacve. Clicking on a Transcode block displays the
corresponding sengs in the “Video/Audio Pipeline Sengs” table, located on the right side. The corresponding tab is also
highlighted for persistent indicaon of the Transcode pipeline sengs currently being shown.
Step 5: Transcoder Conguraon
Transcoders: Sengs
The nal informaon to setup within the unit is located in the “Transcoders:” > “Sengs” tab.
Transcoders: Settings Page - Example

6Clearview+
Quick Guide
Step 5: Transcoder Conguraon (connued)
Transcoders: Status
The informaon shown on this screen indicates the status of each transcoder. A visual status of the pipeline is also shown
on the le side. When hovering over a Transcode block, the corresponding status table highlights.
Transcoders: Status Page - Visual and Informational Status
Pipeline Status States
Light Gray (Red Queson Mark): The transcoder has not been detected yet.
Light Gray: The transcoder is disabled.
Dark Gray (Orange Arrow): The transcoder is idle.
Green: The transcoder is acve.
Red: The transcode has failed.

7
Clearview+
Quick Guide
Troubleshoong
For technical support please contact us at 1-800-523-6049 between the hours of 8am and 5pm EST.
Please refer to the User Manual for addional informaon.
Non-Standard Network Conguraon
Example network conguraon:
1. The Video Source/Sink device's control port is congured to be at 192.168.3.18.
2. The Clearview+ IP Video ports are congured to be at 192.168.6.60 - 192.168.6.71 (XC1 at “192.168.6.60”, XC2 at
“192.168.6.61”, etc.) with subnet masks of 255.255.0.0.
3. The Management PC is congured to be at 192.168.3.5 with a subnet mask of 255.255.0.0.
Note: The subnet mask of the Video Source/Sink device must be congured to be on the same subnet mask as
the Management PC.
Accessing devices from the Management PC:
• To access the Video Source/Sink device, go to hp://192.168.3.18
• To access the Clearview+unit, go to hp://192.168.6.60
Note: Addional Clearview+ units sharing the same network with a single Video Source/Sink device need to have
their transcoder (XC1-12) IP addresses assigned to avoid collisions with XC IP addresses on other Clearview+
units. In other words, all XC IP addresses on a network *must* be unique across all Clearview+units.

One Jake Brown Road
Old Bridge, NJ 08857-1000 USA
732-679-4000 • Fax 732-679-4353
www.blondertongue.com
Returning Product for Repair (or Credit)
A Return Material Authorizaon (RMA) Number is required on all products returned to Blonder Tongue, regardless
if the product is being returned for repair or credit. Before returning product, please contact the Blonder Tongue
Service Department at 1-800-523-6049, Ext. 4256 or visit our website: www.blondertongue.com for further
informaon.
Product and Documentaon Updates
Download the latest User Manual (PDF) by vising our website. Navigate to the product page by entering the full Model
Name or Stock Number in the search eld. Upon reaching the product page, the “User Manual” download link will be
located beneath the product image. Firmware Updates are available under “Tech Support” in the “Resources” secon
of the website. General instrucons for the FTP site, as well as updang your rmware, are provided on this page.
This manual suits for next models
1
Table of contents
Other Blonder tongue Transcoder manuals

Blonder tongue
Blonder tongue AQT8 Series User manual

Blonder tongue
Blonder tongue Clearview 4:2 User manual

Blonder tongue
Blonder tongue Clearview 4:2 User manual

Blonder tongue
Blonder tongue AQT8-QAM User manual

Blonder tongue
Blonder tongue FlexCoder User manual

Blonder tongue
Blonder tongue NXG-CV8 User manual

Blonder tongue
Blonder tongue AQT8-IP User manual

Blonder tongue
Blonder tongue Clearview 4:2 12 User manual

Blonder tongue
Blonder tongue Clearview 4:2 SD User manual