ECHO-5
Ultrasonic Motion Detector
INSTRUCTION MANUAL
GENERAL
The Echo-5 Volumetric Ultrasonic Motion Detector (hereinafter referred to as
the detector) detects an intruder’s movement in the protection area sending an
intruder alarm to a central monitoring station, or to a message sending system,
or to a control indicating equipment by opening the alarm loop using contacts
of the detector’s executive relay.
The detector forms a continuous volumetric detection area in the protected
premises.
The detector provides:
- Three-color light indication of operating modes and interferences;
- Selecting indication modes depending on protection tactics assigned for the
premises (automatically restored or selected alarm indication, alarm memory
feature);
- Disabling alarm indication as well as indication of noise/interference and
motion in protected premises (to provide operating the detector in hide
mode) with enabling indication of detector’s powering on, troubles, power
decreasing, and alarm memory;
- Discrete (four-stage) sensitivity adjustment;
- Using several detectors of this type (spaced at distances at least 5 meters
away from each other) in the same protected premises due to quartz-crystal
control of working frequency;
- Automatic self-diagnostics and testing operability of acoustic transducer,
anti-sabotage protection, monitoring jamming environment in the protected
premises, power voltage monitoring;
- Protection against unauthorized opening the detector’s case (messages about
tampering are generated by opening tamper switch contacts).
The detector is designed for round-the-clock operation.
SPECIFICATIONS
1. The maximum volume of a protected area covered by a single detector:
250 square meters (10 m ×5 m ×5 m).
2. The detector provides detecting radial movement of standard target toward
to the detector with any speed within the range of 0.3 m/s to 2 m/s.
3. The detector is to be powered from a dc power supply with rating voltage
of 12 V with effective ripple voltage no more than 100 mV.
4. Maximum switching current of the executive relay: 30 milliamperes at 72 V
max.
5. Maximum detection range: at least 10 m.
6. Pre-operation time: 10 s max.
7. Consumed current:
- in the quiescent mode: 25 milliamperes max;
- in the alarm mode: 20 milliamperes max.
8. Operating temperatures: −10 to +50°С.
9. The detectors design provides:
a) Ingress protection rating: IP30;
b) Deflecting the detector case from the position in which its front panel is
parallel to the supporting surface at an angle of not less than 30 degrees in
any direction.
10.Overall dimensions: 150 mm ×45 mm ×25 mm max (without the bracket).
11.Weight: 75 g max.
INDICATION AND OPERATION
Three status LEDs of the Echo-5 indicate its operation states as shown in Table 1.
Table 1
Event/Status Indicator’s Behavior DIP Switch
Positions
Green Red Yellow
Power On Any
Quiescent Mode Any
Alarm Switch 4: ON
Alarm Memory Switch 3: ON
Trouble Any
Undervoltage Any
Tampering Any
Noise/Interference Switch 4: ON
Motion Switch 4: ON
– Is lit steady for three seconds
– Off
– Flashes each two seconds during 30 minutes
– Flashes periodically while the signal exists (exceeds the pre-set threshold)
After detector’s power has been switched on, the detector is entering the quiescent
mode opening its ТРЕВ contacts for 3 s (the Power On status) and indicating this
state, as shown in Table 1. After having entered the quiescent mode the contacts of
the executive relay close while the LEDs shut off provided that no faults and
interferences have been occurred.
If a hardware failure has been occurred or some willful acts have been taken to
disturb normal operation of the detector (screening the detector’s faceplate by any
sound proof material or damaging transducers), the detector generates a trouble
message opening ТРЕВ contacts for 30 minutes and indicating this status as shown in
Table 1.
If the power voltage has dropped below (8.0 ±0.5) V, the detector generates an
Undervoltage message by opening ТРЕВ contacts for 30 minutes and indicates this
state as shown in Table 1.
A Noise/Interference status is indicated as shown in Table 1 in case of en external
noise in the protected area.
A Motion status is indicated as shown in Table 1 when a moving entity (a person or a
large thing) is detected.
The detector generates an Alarm message by opening ТРЕВ contacts for 3 s and
indicates this state as shown in Table 1 if the alarm indication is enabled (DIP switch
4 is set to ON).
Indication of Alarm Memory is performed as shown in Table 1 since five minutes
after generating the alarm message if DIP switch 3 is set to ON.
Indication of noise, motion and alarms is enabled only if DIP switch 4 is set to ON.
If there are several statuses to be indicated simultaneously, then alarm memory,
troubles and undervoltage messages are indicated one-by-one. When trouble and
undervoltage messages are being generated, noise/interference and motion indication
is not performed.
When the detector’s cover is open, the detector generates a Tampering message by
opening its ВСКР contacts which are coupled with the in-built tamper switch.
STANDARD DELIVERY
Find the following unpacking the Echo-5:
−Echo-5 Ultrasonic Motion Detector: 1 pc.
−
Bracket: 1 pc.
−
This Instruction Manual: 1 pc.
−
Cross Recessed Round Head Thread Cutting Screw 3×8.01.016: 1 pc.
−
Slotted Countersunk Flat Head Thread Cutting Screw 3×10.01.016: 2 pcs.
−
Slotted Round Head Thread Cutting Screw 3×20.01.016: 1 pc.
−
Countersunk Flat Head Tapping Screw 3×25.016: 2 pcs.
−
Wall Plug: 2 pcs.
MOUNTING THE DETECTOR
MOUNTING LOCATION
Select a mounting location for the detector taking into account the following
considerations:
a) The optimum installation height for the detector is (2.0±0.5) m;
b) The protected assets should be spaced no more than 10 m away from the
detector;
c) The maximum of ultrasonic energy is emitted normally to its faceplate
surface so the main part of the protected area should be in front of it;
d) The detector case can be deflected from the position in which its front
panel is parallel to the supporting surface at an angle of not less than 30
degrees in any direction;
e) Enclosing surfaces (cubicle divisions, large pieces of furniture) can alter
the detection area (verified empirically). Carpets and soft furniture absorb
ultrasound and reduce range of the detector (within 25%). In areas with
smooth walls and floors or in premises with furniture with a smooth finish
or glass that reflect ultrasound, the detection range can increase;
f) Masking the detector with decorative curtains is prohibited because this
can decrease its sensitivity;
g) In large premises (if at least one dimension exceeds 10 meters) or to
provide several local protected areas, several detectors can be used in the
same premises;
h) The detectors with coverage areas opposite to each other should be placed
at a distance of at least 5 meters from each other.
To avoid false alarms:
a) DO NOT install the detector above a radiator, next to an AC, a door, a
window, a sash, blinds, or plants which branches can vary under the
influence of air movement in the premises;
b) DO NOT use the detector in a room with acoustic noise level of more than
75 dB relative to the standard zero of 2.10
-5
Pa (this noise level
approximately corresponds to a loud conversation between two people
indoors).
MOUNTING INSTRUCTIONS
Select the installation scheme and mount the detector to a wall or ceiling at a
height of (2.0±0.5) meters above the floor. Then wire the detector.
Hint: To remove the detector cover, insert the blade of a screwdriver into
the notch at the edge of the case and moving the blade along the perimeter
of the notch separate the detector’s cover from its base.
The layout of the detector’s PCB along with the DIP switches, the terminals,
and the tamper switch on it is shown below:
ADJUSTING THE DETECTOR
1.Ensure the detector is mounted and wired properly and detector’s case and
PCB are secured properly.
2.Make sure the detection range is set to minimum value (DIP switch 1 is OFF
and DIP switch 2 is ON).
3.Enable the alarm indication mode setting DIP switch 4 to ON position.
4.Power up the detector. Its ТРЕВ contacts shall be open for 3 s, all LEDs
being lit steady. Ensure no interference/noise is being indicated for at least
60 s provided that all is OK.
5.Walking through places where intruder’s movement can happen, cause the
detector to trigger. If necessary, increase the detection range by setting DIP
switches 1 and 2 as shown in Table 2.
Table 2
Switch 1 Switch 2 Range
OFF ON Min
ON ON Mid_1
OFF OFF Mid_2
ON OFF Max
6.Finally, arm the detector.
NECESSARY ARRANGEMENTS
In the premises where the detector is installed, for the period of protection the
measures should be provided to ensure:
1)The best closure of the premises (closing all doors, windows, sashes, and other
openings);
2)Creating a normal noise environment (shutting off mechanical ventilation, air
conditioners, electric heaters, fans, rings, bells, audio equipment, power switching
devices and other appliances);
3)No people, animals, and birds.
ZAO NVP Bolid, 4 Pionerskaya Str., Korolev 141070, Moscow
Region, Russia
Phone/fax: +7 495 775-7155
Email: [email protected], overs[email protected]
www.bolid.com

Other bolid Security Sensor manuals

bolid S2000-IK User manual

bolid

bolid S2000-IK User manual

bolid S2000-IPG User manual

bolid

bolid S2000-IPG User manual

bolid S2000-IK Specification sheet

bolid

bolid S2000-IK Specification sheet

bolid S2000-IP-03 User manual

bolid

bolid S2000-IP-03 User manual

bolid IP 212-31 DIP-31 User manual

bolid

bolid IP 212-31 DIP-31 User manual

bolid S2000-BKI User manual

bolid

bolid S2000-BKI User manual

bolid S2000-IK Rev.03 User manual

bolid

bolid S2000-IK Rev.03 User manual

Popular Security Sensor manuals by other brands

Andor Technology Newton user guide

Andor Technology

Andor Technology Newton user guide

GENEVO PRO II manual

GENEVO

GENEVO PRO II manual

Better Water EQSUBWLD Operator's manual

Better Water

Better Water EQSUBWLD Operator's manual

Buckingham BuckCat Series Instructions & warnings

Buckingham

Buckingham BuckCat Series Instructions & warnings

MAKS Water Quick user guide

MAKS

MAKS Water Quick user guide

Milesight EM320-TH-868M user guide

Milesight

Milesight EM320-TH-868M user guide

THORLABS PDAPC3 user guide

THORLABS

THORLABS PDAPC3 user guide

IGM Vega FD 329-3-1 user manual

IGM

IGM Vega FD 329-3-1 user manual

Johnson Controls Tyco SR Series Quick start and installation guide

Johnson Controls

Johnson Controls Tyco SR Series Quick start and installation guide

Energy Saving Sensors HC-7B installation manual

Energy Saving Sensors

Energy Saving Sensors HC-7B installation manual

Baumer UNAM 12N8910/S14O manual

Baumer

Baumer UNAM 12N8910/S14O manual

LOGISTY L3156X instructions

LOGISTY

LOGISTY L3156X instructions

Macurco 6 Series Application guide

Macurco

Macurco 6 Series Application guide

C-LOGIC 645-MD instruction manual

C-LOGIC

C-LOGIC 645-MD instruction manual

Busch-Jaeger Busch-Wachter 220 MasterLINE 6847 Series quick start guide

Busch-Jaeger

Busch-Jaeger Busch-Wachter 220 MasterLINE 6847 Series quick start guide

TimeTec Water Leak Detector user guide

TimeTec

TimeTec Water Leak Detector user guide

Dorlen Water Alert SS-1 instructions

Dorlen

Dorlen Water Alert SS-1 instructions

JFL Alarmes IRA-360 user manual

JFL Alarmes

JFL Alarmes IRA-360 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.