Borg & Overstrom T2 User manual

Borg & OverströmGB01
Dispense Options
Contents
NOTE: This booklet to be left with
appliance following installation
Component/Feature Overview
Operation
Functions & Controls
General Safety
CO2 Bottle Installation
Fault Finding
User Guide
Chilled AmbientSparkling
T2/T2+ Tap systems

General Safety
- Always place the dispenser in its vertical position,
on a surface which can capably support its weight.
- During use this machine must remain in
its upright position.
- Adequate ventilation must be allowed for - we
recommend using the supplied ventilation ducting kit.
- Keep the machine away from sunlight, heat and moisture.
- The environment where this machine is installed must be
free of dust and corrosive/explosive gases.
Basic Troubleshooting
Problem/Report Possible Cause Suggested Action
No Water Dispensing Water Pressure Regulator Contact your distributor
No Sparkling Water -
If applicable
No CO2 pressure Check CO2 bottle, regulator and non- return
valve. Supply pressure should be 58 psi (3.5-
4bar), replace as necessary
Carbonator Tank Not Filling Contact your distributor
Poor Quality Carbonation -
If applicable
Air in Carbonator Tank Isolate the power supply and operate the spar-
kling water tap until gas is expelled. Allow gas
to expel for 5 seconds. Switch on power supply
and allow the tank to rell
Residue in Carbonator Tank After prolonged use, a surface lm can develop
within the carbonator tank. Refer to cleaning
and sanitising instructions
Carbonator Tank is Overlled If pump runs continuously, contact your
distributor
Warm Drinks Insufcient cooling air ow through the fridge Check that the ventilation kit has been installed
correctly.
Compressor not running Contact your distributor
PCB not operating
Fridge failure
General Safety
Refer to instruction manual for full fault codes and diagnostics.

This appliance can be used by children aged from 8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall
not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
The unit should be isolated from the electricity supply before removal of any covers. Great care must be
employed when working with high pressure carbon dioxide, and in no cases should the maximum operating
pressure of 0.4MPa (4 bar) be exceeded.
• The appliance is not suitable for installation in an area where a water jet could be used.
• The appliance has to be placed in a horizontal position.
WARNING: Keep ventilation openings in the appliance enclosure or in the built-in structure clear of obstruction.
WARNING: When positioning the appliance, ensure the supply cord is not trapped or damaged.
WARNING: Do not locate multiple portable socket-outlets or portable power supplies at the rear of the appliance
This appliance is intended to be used in household and similar applications such as:
• Staff kitchen areas in shops, ofces and other working environments
• Farm houses and by clients in hotels, motels and other residential type environments
• Bed and breakfast type environments
• Catering and similar non-retail applications
A-weighted emission sound pressure level is below 70 dB(A)
Waste Electrical Products
• The WEEE symbol indicates that this item contains electronic components which must be
collected and disposed of separately.
• Never dispose of electrical waste in general municipal waste. Collect and dispose of such
waste separately.
• Make use of the return and collection systems available to you, or your local recycling
programme. Contact your local authority or place of purchase to nd out what schemes
are available.
• Electrical and electronic equipment contains hazardous substances which, when disposed
of incorrectly, may leak into the ground. This can contribute to soil and water pollution
which is hazardous to human health; and endangers wildlife.
• It is essential that consumers look to re-use or recycle electrical or electronic waste to avoid
it going to landll sites or incineration without treatment.
R290/R600a is a refrigerant-grade propane used on a wide range of commercial
refrigeration and air conditioning units. A highly pure propane, it has a low environmental
impact and nominal global warming potential (GWP), meaning it possesses no qualities that
can destroy the ozone layer. R290/R600a also is the preferred hydrocarbon alternative of
the Environmental Protection Agency (EPA), substituting more harmful uorocarbon refrigerants
like R22, R134a, R404a and R502. Units with R290/R600a can only be maintained and
repaired by authorized technicians who are properly trained and certied.R290/R600a

Component/Feature Overview
Contents:
1 no T2 Tap
1 no Top Plate with Control Panel
1 no Drip Tray
1 no 1.0m x 6mm Insulated Water Pipe
1 no Connector Cable
1 no Waste Drain Pipe
1 no Fixings Set
Main Body
Faucet
Control Panel
T2 Tap
Drip Tray
Tap Mounting Plate
Connector Cable
Please Note:
Mains Installation Kit & Filters are
supplied as extra items according
to individual ordering requirement.
Water Inlet
Top Panel
Unit Carry Handle
Side Panel
Front Panel
Chilled Water Outlet
Power Connection
On/Off Switch
*Sparkling versions only
Contents:
1 no ProCore or ProCore+ Unit
1 no 2.0m Power Cord Set
1 no Co2 Regulator with Gauge & Connection tube*
1 no Ventilation Ducting Kit
ProCore™ Undercounter
CO2 Inlet*
Tap Connection
Easy-t Ventilation
Base
Ventilation Chimney

Drip Tray
Unit Carry Handle
Functions & Controls
How to Use:
• To dispense water press desired water option and
hold. Release to nish dispensing.
EcoMode: EcoMode will activate in the instance of
dispense inactivity or low light levels, identied by the
EcoMode symbol being illuminated.
• To turn EcoMode on/off, tap the chilled icon 7
times and hold on the 7th. Two beeps will indicate
EcoMode is on, and 1 beep will indicated off.
Chilled icon pulsing: Unit is chilling down.
Warning Symbol: ‘Warning triangle’ will illuminate
and ash when fault is present. Fault code can be
identied by ash sequence.
Controls
Warning SymbolEcoMode
Chilled Water Button
Sparkling Water Button
Ambient Water Button
Model shown with chilled, sparkling and ambient water options.
CO2Bottle Installation - Sparkling Water Model Only
Unpack CO2 Regulator and t
elbow tting to spigot outlet.
Connect the assembled CO2
bottle and regulator to the CO2
inlet using a ¼” pipe.
Stand the cylinder in a suitable
place. We recommend between
3.5 - 4 bar (58 PSI) (max). Do
not exceed 4 bar pressure.
Attach regulator to the CO2
bottle and ensure the small vent
pressure relief vent is facing
away. Close regulator and
tighten securely.
OFF
21 3458 PSI

Connectivity
• Download and connect the Borg and Overström App for Bluetooth®touchless dispense.
• Connect a Bluetooth® alarmed waste kit for drainless-overow protection.
• Connect a SenorBeam foot-switch for touchless foot operation dispense.
Installation Requirements
Identify a suitable location for the ProCore unit. It should be positioned within 1.0m of the faucet, and within
2.0m of suitable services connections. Allow enough space to t the ventilation ducting system.
The ProCore unit must be installed in accordance with the relevant requirements of:
• The appropriate building regulations by application of either The Building Regulations (England and Wales),
The Building Regulations (Scotland) or The Building Regulations (Northern Ireland). In territories other than
those listed the local regulations in force must be complied with.
• The Water Supply (Water Fittings) Regulations (England, Wales and Northern Ireland) or The Water Bye-laws
in Scotland.
• The unit must not be installed where it is liable to freeze. If the unit is thought to be frozen it must not be
switched on. It should be allowed to thaw and must then be thoroughly inspected to ensure it is undamaged.
Water: Mains potable water – internally
regulated to 0.3MPa (3 bar)
Ambient room operating temperature:
Min 5°C - Max 35°C
CO2:Food Grade CO2to be supplied
Min mains pressure: 0.05MPa (0.5 bar) dynamic
Electricity: 5A supply – Earth Leakage Protected

Sanitisation Guide
Please note that this sanitisation uid contains an active caustic/alkaline agent.
Always use responsibly and with care remembering that due to it’s alkaline nature
unnecessary concentrated/prolonged contact with materials,
including metals, can cause damage.
Always rinse all contact surfaces after with clean water.
Avoid skin contact and wear protective gloves when handling sanitisation uids.
In the event of any skin contact, ush immediately with clean, cold water.
5 sec
2Ltr
5 sec
1
11
21
31
4
1
51
61
71
8
1
91
10 1
11 1
12
1
13 1
14 1
15 1
16
1
17 1
18 1
19 1
20
Sanitisation Guide
To be completed by a technician or service provider

© Copyright Borg & Overström.
This guide is printed by Borg & Overström and
shall not be reproduced or copied in anyway.
Ref: 701652
Version: 03
Telephone
+44 (0)1362 695 006
Email
sales@borgandoverstrom.com
borgandoverstrom.com
For full distributor
service manual visit:
www.borgandoverstrom.com/manual/t2
Customer services:
aftersales@borgandoverstrom.com
call +44 1362 695 006
Other manuals for T2
3
This manual suits for next models
1
Table of contents
Other Borg & Overstrom Dispenser manuals

Borg & Overstrom
Borg & Overstrom u2 40L User manual

Borg & Overstrom
Borg & Overstrom u1 User manual

Borg & Overstrom
Borg & Overstrom B6 User manual

Borg & Overstrom
Borg & Overstrom U2 User manual

Borg & Overstrom
Borg & Overstrom T1 Tap systems User manual

Borg & Overstrom
Borg & Overstrom C2 User manual

Borg & Overstrom
Borg & Overstrom b5 User manual

Borg & Overstrom
Borg & Overstrom T1 User manual

Borg & Overstrom
Borg & Overstrom T2 User manual