Boyd PB4000 Dimensional drawing

1
PBM-001
Rev 2
Product Informaon Manual
PEDO Bench
Includes Models: PB4000 & PB4001
12900 44th Street North
Clearwater, Florida 33762
800-255-2693 * 727-561-9292
FAX: 727-561-9393 SALES
FAX: 727-573-1682 SERVICE
www.boydindustries.com
PB4000
PB4001

2
PBM-001
Rev 2
Table of Contents
Title Page
Table of Contents
Introducon
Applicaon of Product
Warranty Statement
Safety Precauons
About Your Product
Descripon of Product Line
General Product Informaon
Product Specicaons
Feature Operaon
Drawer Removal / Installaon and Adjustment
Unpacking and Installaon Procedure
Light Post Installaon (Oponal)
General Maintenance and Care
Cleaning Informaon
Infecon Control
Service Informaon
Authorized Representave (Europe Only)
1
2
3
4
5-8
9
10
11
12

3
PBM-001
Rev 2
Intended Use and Application of Product
This product is designed to allow dental procedures to be performed in a horizontal posion with an adjustable back rest and
head rest. The PEDO bench has built in storage for non-ammable items. The delivery system (PB4000 only) is located close to the
head of the bench (either le or right hand are available) to allow for easy access.
Warranty Statement
All Boyd manufactured products are warranted against defects in material or workmanship only. No other warranes are
expressed or implied. This warranty shall extend for three (3) years for parts and one (1) year for labor. The Boyd warranty only
covers products manufactured by Boyd. Products distributed, not manufactured, by Boyd carry the stated manufacturer’s
warranty.
The warranty period commences upon invoice date of the equipment. Wrien noce of breach must be submied to Boyd
Industries, Inc. within this period. Boyd reserves the right to repair or replace, at its sole discreon, the item in queson.
Warranty is voided if items are misused or product is improperly maintained or installed. The warranty does not cover any
alteraon of the product from its original condion or if product is used in any way other than the product’s design intent.
An authorized service technician must perform all service and maintenance. Any warranty labor must be rst approved by Boyd.
Failure to coordinate warranty service may result in denial of warranty repair. Wrien log and receipts for service must be
maintained to validate the warranty on Boyd manufactured products.
No claim for consequenal damages will be allowed. Freight damage or mishandling by any third party will not be considered a
warranty item. Improper installaon by a third party causing damage to the equipment is not a warranty item.
Introducon
Congratulaons
on your purchase of the Boyd PEDO Bench
Boyd Industries, Inc. has spent years designing and developing the best products available in the world today. The following
features make your Boyd product the most advanced and funconal product available in the market:
PB4000 & PB4001:
Manually adjustable seat back
Cabinet drawer storage
Oponal aached light
Oponal instrument tray
PB4000 Only:
3-Way Syringe
Dry hand piece hook up
Wet hand piece hook up
High Volume Evacuaon (HVE)
Saliva ejecon (SE)
PSI indicator
Oponal assistant package
Oponal boled (clean) water system

4
PBM-001
Rev 2
PEDO Bench
Safety Precauons
Read instrucons:
All safety and operang instrucons including this manual should be read before this product is installed or operated.
Follow instrucons:
All use and operaon instrucons should be followed.
Owners manual:
Retain manual for future reference regarding safety and operaon instrucon.
Heed warnings:
Adhere to all warnings and cauons on the equipment and in the manual.
Accessories:
Do not use any accessories not recommended by Boyd as they may cause hazards.
Cleaning:
See General Maintenance and Care secon
Servicing:
Do not aempt to service this product yourself. Refer any repairs to a qualied service representave.
Heat / Open ame:
Equipment must be installed away from heat sources such as radiators, heat registers or other sources of heat or open ame.
Weight restricon:
This bench is designed to safely support a paent weight of 300 lbs. (136.07 kg) that is evenly distributed across the seat. Always
use the anchoring system to ensure stability of this product. Do not aempt to place all of a paent’s weight on the back rest
with it in a raised posion.

5
PBM-001
Rev 2
Descripon of Product Line
About Your PEDO Bench
Model: PB4000 & PB4001
Features: Manual Back
Storage areas
Instrument Tray (Oponal)
Light Assembly (Oponal)
Chair side units (PB4000 only)
Assistant package (Oponal) (PB4000 only)
General Product Informaon
Cabinet: Wood Construcon
Upholstery: Standard upholstery is vinyl
Upgrades are available
Movement: Manual Seat back
Net Weight: 100 lbs (45.35 kg)
Liquid Protecon: Ordinary equipment (IPX1)
Flammable Gases: Not suitable for use in the presence of ammable gases or where such gases may accumulate in
concentraon. (Closed Space)
Operaon Mode: Connuous
Operang Temperature: 5° C to 40° C (41° F to 104° F)
Temperature: Relave Humidity: 20% to 90% @ 30° C - Not condensing
Atmospheric Pressure: 97kPa
Storage / Transportaon Temperature: -10° C TO 50° C (14° F TO 122° F)
Temperature: Relave Humidity: 20% to 90% @ 30° C - Not condensing
Atmospheric Pressure: 45 to 115kPa
Weight Capacity: 350 lbs (158.75 kg) Subject to normal weight distribuon
Note: Do not sit on back of seat secon. This secon is not designed to support the full weight of paent.
Do not li or slide bench using back secon or seat upholstery.
Warning: Do not modify this equipment without authorizaon from Boyd Industries, Inc.

6
PBM-001
Rev 2
27.00
6.50
21.50
25.00
76.00
46.00
18.00
Product Specicaons
PB4000 & PB4001
About Your PEDO Bench (Connued)
Note: Headrest height is adjustable
approximately 6”. TOP VIEW
SIDE VIEW

7
PBM-001
Rev 2
Feature Operaon
About Your PEDO Bench (Connued)
Headrest: The headrest will adjust in and out to comfortably accommodate the paent.
Foot protector: The foot protector snaps on and o for ease of cleaning and replacement.
Backrest: Acvate the release lever on the boom of the back to posion the back secon.
Adjustment release lever is located on the
boom right side of the back secon.
Note: Drawer size, quanty of drawers and toe kick size can be customized per order upon
customer request and aect overall bench height.
Note: Refer to Delivery Unit Product Manual (DSM-
001) for handpiece instrumentaon package.

8
PBM-001
Rev 2
Drawer Removal/Installaon and Adjustment
About Your PEDO Bench (Connued)
Drawer Removal:
1Pull drawer all the way out.
2Press and hold release levers (2) on boom front of drawer and li drawer upward in front unl it is free from slider.
3Disconnue holding release levers.
4Pull drawer o back tabs of slider.
Drawer Installaon:
1Pull sliders (2) all the way out.
2Place drawer loosely on slider.
3Insert tabs on slider (2) into holes (2) on back wall of drawer and front locks should snap into posion.
4Close drawer
Adjustment Height:
Adjust the height of the drawer face by sliding the red tab located under the drawer in the release lever assembly. Push the tab to-
ward the rear of the drawer to raise the drawer face and toward the front of the drawer to lower drawer face.
Release Levers
Drawer Opened Li and Remove
Hole Locaon
Red Adjustment Tab
Tab Locaon
Slider

9
PBM-001
Rev 2
Installaon Procedure
Preassembly Check:
Open shipping cartons carefully and check to see that all parts are received and have not been damaged during shipping.
Unpacking PEDO Bench:
Remove the plasc banding from the carton.
Remove the carton top secon.
Remove the carton side secons.
Remove the Pedo Bench from the carton by removing the shipping cleats.
Note: Li the pedo bench to move it. Do not slide it or the laminate may get chipped. Do not set bench on any plumbing that
may be hanging from the bench while moving.
Unpacking Procedure
Head if Cabinet to cover in-oor
ulies where applicable
Compartment for water
bole at this end.
Installaon:
Place the bench in desired posion. Place the head side of the cabinet over ulies where applicable.
Secure the bench to the oor. There are two (2) angle brackets and two (2) anchors provided with the bench for securing
the bench to the oor. Access the brackets through an opening under the drawers.
Use supplied #8 x 3/4” long screws to aach angle bracket to bench cabinet.
Drill holes in oor cement using bracket for posion and vacuum holes to remove dust.
Install anchors.
Cauon: Failure to anchor the cabinet will create a safety hazard allowing the Pedo Bench to p.
See “CSU Manual” for delivery unit informaon and ulies.
Anchor
Screws
Angle Bracket
Long side up
Flat Washer
Open Area
Remove drawers
to access
Tools Required:
Hammer Drill
5/16 Carbide Masonry Bit
#2 Phillips Screw Driver
Vacuum

10
PBM-001
Rev 2
Light Post Installaon (Oponal)
The light post installs in the locaon shown below on either side of the bench for units manufactured aer
January 2012.
Call Boyd Industries for informaon on aaching a light post on units manufactured prior to this date.
Benches ordered with the light post opon will arrive with the T-nuts installed and holes cleared in the cabinet to
aach the light post in the locaon requested. Use the hardware provided to aach the post to the side of the
bench and adjust the leveler pad so that it touches the oor and helps to support the post.
Retrong an exisng bench:
All units manufactured aer January 2012 have the mount T-nuts installed on both sides for adding a light post at
any me. The holes are covered by the exterior laminate and will need to be opened up to allow for mounng.
Drill holes in the laminate with a 3/16” diameter drill bit from inside the cabinet using the exisng T-nut locaons
as a guide. Once located, clear the holes from the outside and aach light post as noted above.
Route the cord from the light thru the
top of the post and out the hole at the
boom of the post.
Note: Be sure that there is a plasc
sleeve insert in the top of the post
before inserng the light.
Route the cord thru the access hole in
the side of the Pedo Bench and
connect it to the power transformer
inside of the bench.
Use the hardware provided to aach the
light post to the side of the Pedo Bench.
Adjust the leveler so that it
touches the oor.

11
PBM-001
Rev 2
Infecon Control
All established infection control policies should be followed. All work surfaces and patient contact surfaces should be disinfected
between patients and at the end of the day using a product that is EPA registered as ‘hospital disinfectant’ and labeled for
‘tuberculocidal’ activity.
PB4000 Only:
Hand pieces and metal syringe tips must be autoclaved between patients.
Check manufacturer information for details. (270°F @ 20psi for 30 minutes)
SE, HVE, Tubing, Keyboards and work surfaces must be cleaned and disinfected between patients and at the end of each day.
Use a product that is EPA registered as ‘hospital disinfectant’ and labeled for ‘tuberculocidal’ activity.
Two (2) such products are:
Tri-cide (800)342-3096
Medocadcio (800)777-7072
Do not attempt to clean and re-use disposable tips that are designed for one (1) patient use only.
General Maintenance and Care
Cleaning
It is recommended that the chair and equipment be thoroughly cleaned and disinfected in accordance with the appropriate FDA
guidelines. Use only cleaners and disinfectants approved for cleaning vinyl. Do not use strong or harsh cleaners as they may cause
the vinyl color to fade. Apply the cleaner to a towel, not directly to the vinyl. Refer to vinyl manufacturer’s data on Boyd’s website
for cleaning products. (www.boydindustries.com/support)
Technical Service
For parts, service, or technical information contact:
Worldwide: Boyd Industries, Inc.
12900 44th Street North
Clearwater, Florida USA 33762
tel: 1-727-471-5071 (direct service line)
1-800-255-2693
fax: 1-727-561-9393

12
PBM-001
Rev 2
Boyd Industries, Inc
12900 44th Street N
Clearwater, FL 33762 U.S.A
This manual suits for next models
1
Table of contents
Other Boyd Medical Equipment manuals