BRK electronic PC910VB User manual

CAT. PC910VB
10-YEAR
LITHIUM POWER
10 years of continuous protection.
No battery change required. Provides
audible notice when alarm has reached
its end of life.
VOICE WARNING
WITH LOCATION
Exclusive! A voice will tell you the
programmed location of the unit and
danger detected.
TAMPERPROOF
SEALED ALARM
Powercell cannot be removed.
ELECTROCHEMICAL CO
SENSOR
Most accurate technology available for
detecting carbon monoxide as com-
pared to other sensing technologies.
PHOTOELECTRIC
Photoelectric technology is generally
more sensitive at detecting large par-
ticles, which tend to be produced in
greater amounts by smoldering fires.
SILENCE FEATURE
Silences nuisance alarms.
Description:
BRK Model PC910V is a battery operated, 3V lithium power cell single station smoke
and CO alarm specifically designed for residential and institutional applications in-
cluding sleeping rooms of hospitals, hotels, motels, dormitories, and other multifamily
dwellings as defined in standard NFPA 101. Model PC910V has been fully tested
and complies with, UL217, UL2034 CSFM, NFPA 72, NFPA 720, NFPA 101 and other
agencies that model their codes after the above agencies. It meets building codes
where tamperproof 10-year sealed lithium battery operated smoke and CO alarms
are required and with model building codes published by the ICC.
BRK Model PC910V is a state of the art smoke and CO combination alarm designed
to provide early warning of a fire or carbon monoxide danger. It features a fully insect
screened Photoelectric smoke sensing chamber and an electrochemical CO sensor
and “Voice Warning with Location”. This exclusive feature incorporates a voice that
will speak one of 11 pre-programmed locations and the danger detected. When the
alarm sounds (if programmed for “basement”, for example) it will speak “Warning,
evacuate, smoke in basement”. It features a Sweeping Horn Tone that has a lower
and varying frequency that makes it easier for the elderly with normal age related
hearing loss to hear the horn. It has a sealed 10-year lithium power cell power supply
that is permanently installed, a full function test switch, a silence feature to silence
unwanted nuisance alarms, a red LED light that indicates DC power or alarm. The
tamperproof design will not allow the powercell to be removed. The low power warn-
ing indicator will cause the alarm to “chirp” when it reaches the end of its service
life and needs to be replaced. Upon end of life, the unit meets UL requirements for
disabling the alarm and non-reinstallation of unit to mounting bracket. It also features
a tamper resistant locking pin that locks alarm to the mounting bracket. Perfect for
apartment, dormitory or hotel applications.
The compact, low profile design com-
plements any décor. Designed for
wall or ceiling mounting.
Includes mounting
anchors and
screws.
Sealed 3V Lithium Power Cell
10-YEAR SEALED
SMOKE & CO
COMBO
ALARM
CAT. PC910VB
ARCHITECTURAL AND ENGINEERING SPEC
TECHNICAL SPECS
SHIPPING SPECS
INSTALLATION OF ALARM
The smoke and CO combination alarm shall be a BRK Model PC910V and shall provide
at a minimum the following features and functions:
1. A photoelectric smoke sensing chamber and an electrochemical CO sensor.
2. A Voice Warning of danger detected (Smoke and/or Carbon Monoxide) in addition to
speaking one of 11 pre-programmed locations, e.g. “Warning, Evacuate, Smoke in
Basement”.
3. The unit shall have a lower and varying horn frequency to make it easier for the
elderly with normal age related hearing loss to better hear the horn.
4. A fully screened sensing chamber to resist entry of small insects thereby reducing
the probability of unwanted alarms and be capable of self restoring.
5. Powered by a sealed 10-year lithium powercell with a tamperproof design. The
tamperproof design shall not allow the powercell to be removed. A low power
warning indicator shall cause the alarm to “chirp” when it reaches the end of
its service life and needs to be replaced. Upon end of life, the unit shall meet UL
requirements for disabling the alarm and the non-reinstallation of unit to
mounting bracket.
6. A visual LED power-on indicator to confirm unit is receiving power or is in alarm.
7. A full function test button. The test button should check all alarm functions by
stimulating the chamber to simulate a smoke and CO condition, causing the unit to
alarm.
8. Two Silence features - Low Battery Silence: Silence low battery chirp for up to 8
hours. Alarm Silence: Temporarily silence unwanted nuisance alarms.
9. A tamper resistant locking pin that locks alarm to the mounting bracket.
10. The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and
relative humidity between 10% and 90%.
11. The unit shall contain mounting hardware and shall be listed for wall or ceiling
mounting.
12. The unit shall at a minimum meet the requirements of UL217, UL2034, CSFM, NFPA
72, NFPA 720, NFPA 101, ICC.
Alarm Dimensions: 4.92”L x 4.92”W x 0.96”H
Weight: 5.6 oz
Operating Voltage: 3V Lithium Power Cell
Temperature Range: 40°F (4°C) to 100°F (38°C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Test/Silence: Electronically simulates smoke or CO condition, causing
the unit to alarm. Press and hold test/silence button.
Alarm Reset: Automatic when smoke or CO clears
Smoke Sensor: Photoelectric
CO Sensor: Electrochemical
Indicator Lights/Sounds:
DC Power: Intermittent Red LED
Local Alarm: Audio Alarm, Voice with location, rapidly flashing red LED
Listing: Listed to UL217 and UL2034 Standards
Individual Carton Dimensions 4.94 ”L x 1.31”D x 6.63”H
Weight 0.45 lbs.
Cube 0.03 ft3
UPC 0 29054 01186 2
Master Carton Dimensions 10.50 ”L x 8.13”W x 6.38”H
Master Pack 12
Weight 3.0 lbs.
Cube: 0.32 ft3
I2of5: 200 29054 01186 6
Pallet Information
Cases per Layer 19
Number of Layers: 8
Cases per Pallet: 152
Units per Pallet: 912
Cube: 62.2 ft3
Weight: 527 lbs.
©2013 BRK Brands, Inc. a Jarden Corporation
Company (NYSE: JAH)
3901 Liberty Street Road
Aurora, IL 60504-8122
All rights reserved
First Alert is a registered trademark of the First Alert Trust
BRK is a registered trademark of BRK Brands, Inc.
CM3182
brkelectronics.com
Installation of this smoke alarm must conform to NFPA 72. Always check your local
building codes. Follow all instructions for placement as outlined in the user’s manual in
sections titled “Recommended Locations for Smoke Alarms” and “Locations to Avoid for
Smoke Alarms”.
THE PARTS OF THIS SMOKE & CO ALARM
1. Test/Silence button
2. LED alarm light
3. Activate/Deactivate Switch
4. Locking tab slot (Break out Tab)
5. Locking tab
6. Mounting bracket
7. “This way up” Arrow
8. Mounting Slots
9. Speaker Grill
MOUNTING
BRACKET
TOP VIEW SIDE VIEW
4.9” 4.3”
4.9”
1”
4.3”
1
2
3
4
5
6
7
8
8
Activate/Deactivate
Switch-Detail
Break and remove tab then
slide switch to deactivate
OFF - ON - DISCHARGE
9

Other BRK electronic Security System manuals

BRK electronic D702MC User manual

BRK electronic

BRK electronic D702MC User manual

BRK electronic C0250B User manual

BRK electronic

BRK electronic C0250B User manual

BRK electronic MPG120 User manual

BRK electronic

BRK electronic MPG120 User manual

BRK electronic First Alert SC9120LBLA User manual

BRK electronic

BRK electronic First Alert SC9120LBLA User manual

BRK electronic 7030BSL User manual

BRK electronic

BRK electronic 7030BSL User manual

BRK electronic First Alert SC9120BA User manual

BRK electronic

BRK electronic First Alert SC9120BA User manual

BRK electronic CO910V User manual

BRK electronic

BRK electronic CO910V User manual

Popular Security System manuals by other brands

Utilitech UT-6168 installation instructions

Utilitech

Utilitech UT-6168 installation instructions

StopSleep StopSleep user guide

StopSleep

StopSleep StopSleep user guide

Lorex SHS-4QM Series Quick setup guide

Lorex

Lorex SHS-4QM Series Quick setup guide

Brandson Rauchmelder user manual

Brandson

Brandson Rauchmelder user manual

inVue Zips ZB1000 manual

inVue

inVue Zips ZB1000 manual

CrucialTrak BACS Tube Quick user guide

CrucialTrak

CrucialTrak BACS Tube Quick user guide

DSC SEA-B-QUE user manual

DSC

DSC SEA-B-QUE user manual

Kidde KF30 user manual

Kidde

Kidde KF30 user manual

First Alert FA1660C Installation and setup guide

First Alert

First Alert FA1660C Installation and setup guide

RAB Lighting Sound Alert installation manual

RAB Lighting

RAB Lighting Sound Alert installation manual

Siren R3+ user guide

Siren

Siren R3+ user guide

Zoom Dialer 26 Installation and user guide

Zoom

Zoom Dialer 26 Installation and user guide

CareAlert CA-0813 Operation and instruction manual

CareAlert

CareAlert CA-0813 Operation and instruction manual

eTIGER S2 manual

eTIGER

eTIGER S2 manual

Samsung SSC17WEB user guide

Samsung

Samsung SSC17WEB user guide

switel BC 110 operating instructions

switel

switel BC 110 operating instructions

ARGSeguridad ZDAS-300 user manual

ARGSeguridad

ARGSeguridad ZDAS-300 user manual

Solar Ajax quick start guide

Solar

Solar Ajax quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.