manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BRK electronic
  6. •
  7. Smoke Alarm
  8. •
  9. BRK electronic FG225B User manual

BRK electronic FG225B User manual

This manual suits for next models

1

Other BRK electronic Smoke Alarm manuals

BRK electronic 9120LBLA User manual

BRK electronic

BRK electronic 9120LBLA User manual

BRK electronic Dicon M300 User manual

BRK electronic

BRK electronic Dicon M300 User manual

BRK electronic PC910B User manual

BRK electronic

BRK electronic PC910B User manual

BRK electronic Smoke Alarm User manual

BRK electronic

BRK electronic Smoke Alarm User manual

BRK electronic 7010BA User manual

BRK electronic

BRK electronic 7010BA User manual

BRK electronic 83RN User manual

BRK electronic

BRK electronic 83RN User manual

BRK electronic SA340B User manual

BRK electronic

BRK electronic SA340B User manual

BRK electronic 7030BSLA User manual

BRK electronic

BRK electronic 7030BSLA User manual

BRK electronic BRK Electronics User manual

BRK electronic

BRK electronic BRK Electronics User manual

BRK electronic SL177 User manual

BRK electronic

BRK electronic SL177 User manual

BRK electronic 9120 Series User manual

BRK electronic

BRK electronic 9120 Series User manual

BRK electronic FG250 User manual

BRK electronic

BRK electronic FG250 User manual

BRK electronic DS700RF User manual

BRK electronic

BRK electronic DS700RF User manual

BRK electronic FG225 User guide

BRK electronic

BRK electronic FG225 User guide

BRK electronic 4010YR User manual

BRK electronic

BRK electronic 4010YR User manual

BRK electronic Smoke Alarms User manual

BRK electronic

BRK electronic Smoke Alarms User manual

BRK electronic SC9120B User manual

BRK electronic

BRK electronic SC9120B User manual

BRK electronic SC7010BV User manual

BRK electronic

BRK electronic SC7010BV User manual

BRK electronic FG250B Series User manual

BRK electronic

BRK electronic FG250B Series User manual

BRK electronic 4120B User manual

BRK electronic

BRK electronic 4120B User manual

BRK electronic SC7010LBLV User manual

BRK electronic

BRK electronic SC7010LBLV User manual

BRK electronic 7010BSL User manual

BRK electronic

BRK electronic 7010BSL User manual

BRK electronic SA350B User manual

BRK electronic

BRK electronic SA350B User manual

BRK electronic 650M User manual

BRK electronic

BRK electronic 650M User manual

Popular Smoke Alarm manuals by other brands

Dyna-Glo DGY784BDP installation instructions

Dyna-Glo

Dyna-Glo DGY784BDP installation instructions

NOXE LUMENS Installation and user guide

NOXE

NOXE LUMENS Installation and user guide

Develco SMAZB-141 installation manual

Develco

Develco SMAZB-141 installation manual

Kidde PI2010CA user guide

Kidde

Kidde PI2010CA user guide

Honeywell 5800COMBO Installation and setup guide

Honeywell

Honeywell 5800COMBO Installation and setup guide

Gentex 7109CS installation instructions

Gentex

Gentex 7109CS installation instructions

FireAngel Thermoptek ST-622 user manual

FireAngel

FireAngel Thermoptek ST-622 user manual

teko Astra-42A user guide

teko

teko Astra-42A user guide

ELRO FS8110 instruction manual

ELRO

ELRO FS8110 instruction manual

Heiman SMOKI NS-626PHS user manual

Heiman

Heiman SMOKI NS-626PHS user manual

Siemens PE-11C installation instructions

Siemens

Siemens PE-11C installation instructions

Resolution Products RE612 CryptiX quick start guide

Resolution Products

Resolution Products RE612 CryptiX quick start guide

First Alert PC900V user manual

First Alert

First Alert PC900V user manual

Eminent EM6590 E-Domotica user manual

Eminent

Eminent EM6590 E-Domotica user manual

Ei Electronics Ei Ei168RC user manual

Ei Electronics

Ei Electronics Ei Ei168RC user manual

Carrier Kidde Quell Q301 user manual

Carrier

Carrier Kidde Quell Q301 user manual

Family Gard FG225 user manual

Family Gard

Family Gard FG225 user manual

Regin SDD-S65 instruction manual

Regin

Regin SDD-S65 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

9V Battery Powered
Smoke
AlArm
CAT. FG225B/FG250B
Description:
BRK Models FG225 and FG250 are single station smoke alarms specifically designed
for residential and institutional applications including sleeping rooms of hospitals,
hotels, motels, dormitories, and other multifamily dwellings as defined in standard NFPA
101. Models FG225 and FG250 have been fully tested and comply with, UL217, CSFM,
NFPA 72, and NFPA 101 and other agencies that model their codes after the above
agencies.They meet building codes where DC (FG225) and DC with Silence (FG250) smoke
alarms are required and with model building codes published by the ICC.
BRK Models FG225 and FG250 are state of the art smoke alarms designed to provide
early warning of a fire. They feature a fully insect screened dual ionization smoke
sensing chamber, an 85dB horn, a supervised 9V battery power supply, a full function
test switch, a silence feature (FG250 only) to silence unwanted nuisance alarms, a
red LED light that indicates DC power or alarm. Each also feature a tamper resistant
locking pin that locks alarm cover to prevent removal of battery. Perfect for apartment,
dormitory or hotel applications. The compact, low profile design complements any
décor. Battery installation and removal can occur while the unit is mounted to the
ceiling or wall via the hinged cover. When voltage drops to a pre-set warning level, the
horn will “chirp” approximately once per minute to indicate a fresh battery is needed.
To insure the battery is always replaced properly, the cover is designed to resist closing
when the battery is missing. Designed for wall or ceiling mounting. Includes mounting
anchors and screws. Both models are approved for use in recreational vehicles.
DUAl IoNIZATIoN
Dual Ionization sensing chamber.
Generally more effective at
detecting small particles produced
by flaming fires. Sources may
include paper or kitchen grease.
SIleNCe FeATUre
(FG250 only) Silences nuisance alarms.
HINGeD CoVer
DeSIGN
Fast and easy installation
and battery replacement
TAmPer reSISTANT
loCkING PIN
Locks alarm cover to prevent
removal of battery. Perfect for
apartment, dormitory or hotel
applications.
9V BATTerY
INClUDeD
APProVeD For
rV USe
Available in the following versions:
FG225B Carbon Zinc Battery
FG250B Silence with Carbon Zinc Battery
FG250AB Silence with Alkaline Battery
FG250LB Silence with Lithium Battery
Listed to
Standard
UL 217
Listed to
Standard
UL 1971
Individual Carton Dimensions 4.38 ”L x 1.75”W x 4.38”H
Weight .67lbs.
Cube .02 ft3
UPC FG225B: 0 29054 00303 4
FG250B: 0 29054 00300 3
FG250AB: 0 29054 00311 9
FG250LB: 0 29054 00310 2
Master Carton Dimensions 9.2 ”L x 5.5”W x 5.1”H
Master Pack 6
Weight 3.2 lbs.
Cube .15 ft3
I2 of 5 FG225B: 600 29054 00303 6
FG250B: 600 29054 00300 5
FG250AB: 600 29054 00311 1
FG250LB: 600 29054 00310 4
Pallet Information
Cases per Layer 36
Number of Layers 9
Cases per Pallet 324
Units per Pallet 1,944
Cube 55.0 ft3
Weight 1,107lbs.
Alarm Dimensions: 4.25” dia x 1.6”H
Weight: 4.8 oz.
Operating Voltage: 9V Battery Powered
Temperature Range: 40˚F (4˚C) to 100˚F (38˚C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Test/Silence:
(FG250)
Electronically simulates smoke condition, causing
the unit to alarm
Alarm Reset: Automatic when smoke clears
Smoke Sensor: Dual Ionization
Indicator Lights:
DC Power: Intermittent Red Light
Listing ETL to UL217 Standard
brkelectronics.com
INSTALLATION OF ALARM
SHIPPING SPECS:
TECHNICAL SPECS:
CAT. FG225B/FG250B
©2008 BRK Brands, Inc. a Jarden Corporation
company (NYSE: JAH)
3901 Liberty Street Road
Aurora IL 60504-8122
All rights reserved
BRK is a registered trademark of BRK
Brands,Inc.
CM2885
ARCHITECTURAL AND ENGINEERING SPEC
1. A dual ionization sensing chamber.
2. The unit shall be capable of self restoring.
3. A fully screened sensing chamber to resist entry of small insects
thereby reducing the probability of unwanted alarms.
4. Powered by a supervised 9V battery and a solid state piezo horn
rated at 85dB at 10 ft.
5. A visual LED power-on indicator to confirm unit is receiving power or
is in alarm.
6. A full function test button. The test button should check all alarm
functions by stimulating the chamber to simulate a smoke condition,
causing the unit to alarm. Model FG250 also has a silence feature to silence
unwanted nuisance alarms.
7. A tamper resistant locking pin that locks alarm cover to prevent removal
of battery.
8. The unit shall be capable of operating between 40°F (4°C) and
100°F (38°C) and relative humidity between 10% and 90%.
9. The unit shall contain mounting hardware and shall be listed for wall
or ceiling mounting.
10. The unit shall at a minimum meet the requirements of UL217, CSFM,
NFPA 72, NFPA 101, ICC.
11. The unit shall be suitable for use in Recreational Vehicles.
Installation of this smoke alarm must conform to NFPA 72. Always check
your local building codes. Follow all instructions for placement as outlined
in the user’s manual in sections titled “Recommended Locations for
Smoke Alarms” and “Locations to Avoid for Smoke Alarms”.
4.25”
FRONT
VIEW
SIDE
VIEW
Back
View
1.6”
1
2
3
4
5
7
6
8
1. “Open Here”
2. “No Battery” tab
3. Test button or
Test/Silence button (FG250 only)
4. Smoke alarm base
5. Mounting slots
6. Install 9V battery here
7. Locking pin slot
8. Locking pin: Remove and insert in 7
The parts of this smoke alarm
7