manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BRK electronic
  6. •
  7. Smoke Alarm
  8. •
  9. BRK electronic 7010BA User manual

BRK electronic 7010BA User manual

120V AC, 60Hz Wire-in
with 9V Battery Backup
PHOTOELECTRIC
Photoelectric technology is generally
more sensitive at detecting large
particles, which tend to be produced in
greater amounts by smoldering res.
LATCHING ALARM
INDICATOR
Remembers which unit initiated an alarm.
OPTIPATH 360
TECHNOLOGY™
Provides 360 degrees of direct access to
the smoke sensing chamber.
SILENCE FEATURE
Silences nuisance alarms.
TWO LOCKING
FEATURES
Pins are provided to lock battery drawer
and/or alarm to base. Perfect for
apartment, dormitory or hotel applications.
END OF LIFE
SIGNAL
Provides audible notice when alarm needs
to be replaced after 10 years.
Description:
BRK Model 7010BA (Cat. 7016BTCA) is a wire-in, 120V AC 60Hz single and/or
multiple station photoelectric smoke alarm specically designed for residential
and institutional applications including sleeping rooms of hospitals, hotels, motels,
dormitories and other multi-family dwellings as dened in standard NFPA 101. Model
7010BA complies with ULC S531, NFPA 72, HUD, FHA and other agencies that
model their codes after the above agencies. Alarms are interconnectable with up to
18 devices, of which 12 can be smoke alarms.
BRK 7010BA features a photoelectric smoke sensing chamber, an 85dB horn, a
9V battery back-up and a “silence” feature. Optipath 360 technology provides
360 degrees of direct access to the smoke sensing chamber. Alarm Latch: Easily
identies initiating alarm even after alarm condition has subsided. The “Perfect
Mount” system features a gasketless base and a mounting bracket that keeps the
alarm secure over a wide rotation range to allow for true alignment. This will allow
ne-tuning on the positioning to compensate for out of aligned wall studs and to keep
the wording level when wall mounting. Battery installation and removal can occur
while the unit is mounted to the ceiling or wall via the side load battery compartment.
Other Contractor Preferred features include a dust cover to keep alarm clean during
construction, keyhole slots in the mounting bracket eliminate the need to remove the
electrical box screws for installation. Two locking features are provided to prevent
battery theft and/or theft of the unit. Connection to AC power is made with a “Quick-
Connect” wiring harness. Installation is quick, easy and cost effective.
Model 7016BTCA
Model 7010BA
CAT. 7016BTCA
SMOKE
ALARM
PHOTOELECTRIC
ARCHITECTURAL AND ENGINEERING SPECS
The smoke alarm shall be a BRK Model 7010BA (Cat. 7016BTCA) and shall provide at a
minimum the following features and functions:
1. A photoelectric smoke sensing chamber.
2. A fully screened sensing chamber to resist entry of small insects thereby reducing the
probability of unwanted alarms.
3. Powered by 120V AC, 60Hz and have a monitored 9V battery backup and a solid state
piezo horn rated at 85dB at 10 ft.
4. A visual LED power-on indicator to conrm unit is receiving power or is in alarm.
5. A full function test button. The test button should check all alarm functions by stimulating
the chamber to simulate a smoke condition, causing the unit to alarm.
6. Latching & silence features: Alarm Latch to easily identify initiating alarm after alarm
condition has subsided. Silence feature - Temporarily silence unwanted nuisance alarms.
7. Two Locking features - tamper resistant locking pins that lock battery drawer and/or
alarm to mounting bracket.
8. The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and relative
humidity between 10% and 95%.
9. The unit shall have a gasketless base for easy installation and be capable of keeping alarm
secure over a wide rotation range to allow for true alarm alignment.
10. The unit shall have a plug in connector and be capable of interconnection of up to
18 alarms, 12 of which can be smoke alarms.
11. The unit shall at a minimum meet the requirements of ULC S531, NFPA 72, NFPA 101, and ICC.
12. The unit shall have an “End of Life” signal.
TECHNICAL SPECS
Alarm Dimensions: 5.0" Dia. x 2.1" H
Weight: 8.4 oz
Operating Voltage: 120V AC 60Hz w/ 9V battery backup
Temperature Range: 40°F (4°C) to 100°F (38°C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Test/Silence: Electronically simulates smoke condition,
causing the unit to alarm. Press and hold
test/silence button.
Alarm Reset: Unit will remain in latch mode until manually reset
Interconnections: Up to 18 units of First Alert or BRK Smoke,
CO and Heat Alarms. Maximum of 12 smoke
alarms. See user’s manual for details.
Smoke Sensor: Photoelectric
Indicator Lights/Sounds:
AC Power: Constant Green LED
DC Power: Intermittent Red LED
Local Alarm: Red LED ashes rapidly
Latching Alarm: Green LED ashes
Remote Alarm: Audio alarm and Red LED out
End of Life: Horn sounds 5 chirps; pattern repeats once/minute
Listing: Certied to ULC STD S531
SHIPPING SPECS
Individual Carton Dimensions 5.1" L x 2.4" W x 5.1" H
Weight: 0.6 lbs.
Cube: 0.04 ft3
UPC: 0 29054 01043 8
Master Carton Dimensions 10.6" L x 7.9" W x 10.9" H
Master Pack: 12
Weight: 8.2 lbs.
Cube: 0.5 ft3
I2of5: 200 29054 01043 2
Pallet Information
Cases per Layer: 22
Number of Layers: 4
Cases per Pallet: 88
Units per Pallet: 1056
Cube: 53.9 ft3
Weight: 748 lbs.
1. Smoke Alarm
2. Ceiling or Wall
3. Power Connector
4. Wire Nut
5. Junction Box
6. Neutral Wire (White)
7. Interconnect Wire (Orange)
8. Hot Wire (Black)
THE PARTS OF THIS ALARM
1. Mounting bracket
2. Mounting Slots
3. Locking Pins
4. Hot (Black) AC Wire
5. Neutral (White) AC Wire
6. Interconnect (Orange) Wire
7. Pull out Battery Drawer
8. Quick-Connect Plug
A. Unswitched 120VAC 60 Hz source
B. To additional units; Maximum = 18 total
(Maximum 12 Smoke Alarms)
2
8
1
7
6
5
4
3
2
INSTALLATION OF ALARM
Installation of this smoke alarm must conform to all local
electrical codes and Article 760 of the National Electrical
Code (NFPA 70) and NFPA 72. Interconnected units must
meet the following requirements: Total length of wire
interconnecting units should be less than 1000 feet,
be #18 gauge or larger and be rated at least 300V. It is
recommended that all units be on the same fuse or circuit
breaker. If local codes do not permit, be sure the neutral
wire is common to both phases.
© 2021 BRK Brands, Inc. All rights reserved. Distributed
by BRK Brands, Inc., Aurora, Illinois 60504. BRK Brands,
Inc. is a subsidiary of Newell Brands Inc. (NASDAQ: NWL).
brkcanada.ca REV 11/20
Model 7010BA
CAT. 7016BTCA
MOUNTING
BRACKET
TOP VIEW SIDE VIEW
5.0"
2.1"
678
4 3 1
52
A
B
}}
4 3 15

This manual suits for next models

1

Other BRK electronic Smoke Alarm manuals

BRK electronic P H O T O & I O N 3120B User manual

BRK electronic

BRK electronic P H O T O & I O N 3120B User manual

BRK electronic SA340B User manual

BRK electronic

BRK electronic SA340B User manual

BRK electronic 100S User manual

BRK electronic

BRK electronic 100S User manual

BRK electronic 4120 AC User manual

BRK electronic

BRK electronic 4120 AC User manual

BRK electronic 9120LBLA User manual

BRK electronic

BRK electronic 9120LBLA User manual

BRK electronic 4010YR User manual

BRK electronic

BRK electronic 4010YR User manual

BRK electronic 650M User manual

BRK electronic

BRK electronic 650M User manual

BRK electronic First Alert Dicon M300 User manual

BRK electronic

BRK electronic First Alert Dicon M300 User manual

BRK electronic PRC710B User manual

BRK electronic

BRK electronic PRC710B User manual

BRK electronic 83R-UK User manual

BRK electronic

BRK electronic 83R-UK User manual

BRK electronic 2002 User manual

BRK electronic

BRK electronic 2002 User manual

BRK electronic 4000LB User manual

BRK electronic

BRK electronic 4000LB User manual

BRK electronic BRK Electronics User manual

BRK electronic

BRK electronic BRK Electronics User manual

BRK electronic 9120 Series User manual

BRK electronic

BRK electronic 9120 Series User manual

BRK electronic SC7010LBLV User manual

BRK electronic

BRK electronic SC7010LBLV User manual

BRK electronic DS700RF User manual

BRK electronic

BRK electronic DS700RF User manual

BRK electronic 650M User manual

BRK electronic

BRK electronic 650M User manual

BRK electronic SC7010LBLV User manual

BRK electronic

BRK electronic SC7010LBLV User manual

BRK electronic 7030BSL User manual

BRK electronic

BRK electronic 7030BSL User manual

BRK electronic SA320B User manual

BRK electronic

BRK electronic SA320B User manual

BRK electronic 7030BSLA User manual

BRK electronic

BRK electronic 7030BSLA User manual

BRK electronic PRC700VB User manual

BRK electronic

BRK electronic PRC700VB User manual

BRK electronic 83RN User manual

BRK electronic

BRK electronic 83RN User manual

BRK electronic First Alert P1010 User manual

BRK electronic

BRK electronic First Alert P1010 User manual

Popular Smoke Alarm manuals by other brands

Linear DXS FORMAT DXS-72 installation instructions

Linear

Linear DXS FORMAT DXS-72 installation instructions

Ei Electronics Heat Alarm Ei 103R Technical specifications

Ei Electronics

Ei Electronics Heat Alarm Ei 103R Technical specifications

Notifier SD-851E manual

Notifier

Notifier SD-851E manual

Snoos Heat Alarm user guide

Snoos

Snoos Heat Alarm user guide

Simplex 2098-9207A installation instructions

Simplex

Simplex 2098-9207A installation instructions

FireClass 601P quick start guide

FireClass

FireClass 601P quick start guide

pyrexx PX-1 operating manual

pyrexx

pyrexx PX-1 operating manual

jablotron JA-110ST quick start guide

jablotron

jablotron JA-110ST quick start guide

Autronica AutroSense Nano Installation handbook

Autronica

Autronica AutroSense Nano Installation handbook

Swegon TBLZ-1-93-a-b Installation

Swegon

Swegon TBLZ-1-93-a-b Installation

Honeywell Fire-Lite Alarms D350RPL Installation and maintenance instructions

Honeywell

Honeywell Fire-Lite Alarms D350RPL Installation and maintenance instructions

Firex 46184 quick guide

Firex

Firex 46184 quick guide

Vivanco SD 3-N operating instructions

Vivanco

Vivanco SD 3-N operating instructions

Chacon 34234 user manual

Chacon

Chacon 34234 user manual

Zipato Z-Wave PH-PSG01 Quick installation guide

Zipato

Zipato Z-Wave PH-PSG01 Quick installation guide

jablotron JA-151ST manual

jablotron

jablotron JA-151ST manual

Kidde 0910UK Installer's guide

Kidde

Kidde 0910UK Installer's guide

System Sensor FAAST LT-200 Setup guide

System Sensor

System Sensor FAAST LT-200 Setup guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.