WIRE THE VENTILATOR
WARNING:
SWITCHPOWER OFFAT SERVICEPANELANDLOCKSERVICE
PANELBEFOREMAKINGELECTRICALCONNECTIONS.
WHITE
BLACK
120/127 VAC
POWER CABLE
WIRING
BOX GROUND
TAPE HERE
ATTACH GRILLE
BROANMFG.CO.,INC./ANORTEKCOMPANY 926W.StateStreet,Hartford,WI53027
1.Attachpowercabletoelectricalwiringboxandswitchboxusing
the proper connector for the type of cable being used.
2. Make electrical connections. Connect black to black, white to
white and bare or green wire to electrical wiring box using the
green ground screw.
CONNECT THE DUCT
(FOR WALLS 6" TO 10" THICK ONLY - INCLUDING INSIDE AND
OUTSIDE WALL COVERINGS)
1. Stretch the adjustable duct, slide it over the housing and tape it in
place. (You may need to shorten non-tapered end of flexible duct
to fit.)
INSTALL VENTILATOR IN WALL
1. Place ventilator into wall opening. Re-install electrical wiring box
and cover. Plug motor into receptacle in wiring box cover.
2. Fasten ventilator to inside wall with appropriate screws.
1. From outside, slip adjustable duct into wall cap and tape the joint.
2.Compresstheexcessductbackintotheopeningbypositioningthe
wall cap against the outside wall.
3. Fasten wall cap to outside wall and caulk around the edges.
ON/OFF
SWITCH
TAPE HERE
ATTACH WALL CAP
(FOLLOW STEPS 1 & 2 ONLY IF ADJUSTABLE DUCT IS USED)
BROAN ONE YEAR LIMITED WARRANTY
Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or
workmanshipforaperiodof oneyearfrom thedateof originalpurchase.THERE ARENOOTHER WARRANTIES,EXPRESSOR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULARPURPOSE.
During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be
defective under normal use and service.
THISWARRANTYDOESNOT EXTEND TO FLUORESCENT LAMP STARTERSANDTUBES.Thiswarrantydoesnot cover (a)
normalmaintenance and service or(b)any products or parts whichhavebeen subject to misuse, negligence,accident,improper
maintenance or repair (other than by Broan), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not
allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND
EXCLUSIVEREMEDYUNDERTHISWARRANTY.BROANSHALLNOTBELIABLEFORINCIDENTAL,CONSEQUENTIALOR
SPECIALDAMAGESARISINGOUTOFORINCONNECTIONWITHPRODUCTUSEORPERFORMANCE.Somestatesdonot
allowtheexclusion or limitation ofincidentalorconsequentialdamages,so the above limitationorexclusionmaynotapply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty
supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan at the address stated below or telephone: 1-800-637-1453, (b) give the
model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting
warranty service, you must present evidence of the original purchase date.
BROAN MFG. CO., INC., 926 West State Street, Hartford, WI 53027
1
2
3
6
79
8
3
12
10
11
13
* Standard Hardware - May be purchased locally.
Always order replacement parts by “PART NO." - NOT by “KEY NO.”
1 99110454 Grille
2 99260428 #6-32 Sheet Metal Nut (2 req.)*
3 99170245 #8B x 3/8 Sheet Metal Screw (3 req.)*
4 97005322 Motor Mounting Bracket 97005322
5 99080199 Motor
6 99020125 Blade
7 98004932 Wiring Box Cover
8 99150471 #10-32 x 1/2 Green Ground Screw*
9 98005329 Wiring Box
10 97011741 Housing
11 99270982 Receptacle
12 99610012 Adjustable Duct
13 97011740 Wall Cap
DESCRIPTION
NO.
PART
NO.
KEY
1. Spingrilleontoitsmountingscrewuntilthe
grille is tight against the wall.
2. Turn on the power and check for proper
operation of ventilator.
USE AND CARE
WARNING: SWITCH OFF POWER AT SERVICE PANEL AND LOCK
SERVICE PANEL BEFORE CLEANING OR SERVICING THIS VENTI-
LATOR.
TO CLEAN FAN ASSEMBLY:
Unplug motor from black receptacle. Remove the motor assembly by
looseningthemountingscrewsandrotatingthemotorassemblyclockwise.
Gentlyvacuummotor assembly andinsideof housing.
METALANDELECTRICALPARTSSHOULDNEVERBEIMMERSEDIN
WATER.
PERIODICALLY CHECK THE OUTER LOUVER FOR ACCUMULATED
DUST,LINT, ETC.,WHICH MAYINTERFEREWITHPROPERLOUVER
CLOSURE.
WARNING: DO NOT SPRAY WATER INTO LOUVER-DAMAGE TO
THE FAN COULD OCCUR AND WATER COULD ENTER HOUSE.
MOTORLUBRICATION
Themotoris permanentlylubricated.Do not oilor disassemble motor.
SERVICE PARTS
Model512M
5
4
99041808D