INSTALL THE VENTILATOR
WARNING:
WHENCUTTINGORDRILLINGINTOWALL,
DO NOT CUT EXISTING ELECTRICAL WIRING.
CAUTION:
Do not mount the ventilator above a cook-
ing surface.
CAUTION:
Measure and mark the center of wall open-
ing on inside and outside walls before cutting open-
ing.
1. Cut a 6" diameter opening in the wall.
PLAN THE INSTALLATION
The ventilator can be installed in outside walls walls up to 10" thick.
Walls less than 6" thick will not use the adjustable duct. Choose a
locationwithnoobstructions,suchaswallstuds,plumbingorelectrical
wiring.
The ventilator can be controlled using a wall switch or speed control
(availableseparately).
CAUTION
1. Forgeneralventilatinguseonly.Donotusetoexhausthazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers,keepdrywallspray,constructiondust,etc.offpowerunit.
3. Please read specification label on product for further information
andrequirements.
WARNING
WARNING
TOREDUCE THERISK OFFIRE,ELECTRICSHOCK,ORINJURY
TOPERSONS, OBSERVETHEFOLLOWING:
1 . Usethisunitonlyinthemannerintendedbythemanufacturer.Ifyou
have questions, contact the manufacturer at the address or tele-
phonenumberlisted belowthewarranty.
2. Beforeservicingorcleaningunit,switchpoweroffatservicepanel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
includingfire-ratedconstructioncodesand standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fueling equipment to prevent
backdrafting.Followtheheatingequipmentmanufacturer’sguide-
lineandsafety standards suchasthosepublished by theNational
FireProtectionAssociation(NFPA),and the American Societyfor
Heating,RefrigerationandAirConditioningEngineers(ASHRAE),
andthelocal code authorities.
5. Whencuttingordrillingintowallorceiling,donotdamageelectrical
wiringandotherhiddenutilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. Thisunitmustbegrounded.
READ AND SAVE THESE INSTRUCTIONS
MODEL 512M
THROUGH-THE-WALL VENTILATOR
2. Unplug motor, loosen screw and remove electrical wiring box
cover.
3. Push electrical wiring box into housing and lift out.
Note:Foreasierremovalofwiringbox, remove the motor assembly.
Loosen the mounting screws and rotate the motor assembly
clockwise.
VENTILATOR
GRILLE
WALL
CAP
ADJUSTABLE
DUCT
5¼" TO 10"
WIRE THE VENTILATOR
WARNING:
SWITCHPOWER OFFAT SERVICEPANELANDLOCKSERVICE
PANELBEFOREMAKINGELECTRICALCONNECTIONS.
WHITE
BLACK
120/127 VAC
POWER CABLE
WIRING
BOX GROUND
TAPE HERE
ATTACH GRILLE
BROANMFG.CO.,INC./ANORTEKCOMPANY 926W.StateStreet,Hartford,WI53027
1.Attachpowercabletoelectricalwiringboxandswitchboxusing
the proper connector for the type of cable being used.
2. Make electrical connections. Connect black to black, white to
white and bare or green wire to electrical wiring box using the
green ground screw.
CONNECT THE DUCT
(FOR WALLS 6" TO 10" THICK ONLY - INCLUDING INSIDE AND
OUTSIDE WALL COVERINGS)
1. Stretch the adjustable duct, slide it over the housing and tape it in
place. (You may need to shorten non-tapered end of flexible duct
to fit.)
INSTALL VENTILATOR IN WALL
1. Place ventilator into wall opening. Re-install electrical wiring box
and cover. Plug motor into receptacle in wiring box cover.
2. Fasten ventilator to inside wall with appropriate screws.
1. From outside, slip adjustable duct into wall cap and tape the joint.
2.Compresstheexcessductbackintotheopeningbypositioningthe
wall cap against the outside wall.
3. Fasten wall cap to outside wall and caulk around the edges.
ON/OFF
SWITCH
TAPE HERE
ATTACH WALL CAP
(FOLLOW STEPS 1 & 2 ONLY IF ADJUSTABLE DUCT IS USED)
BROAN ONE YEAR LIMITED WARRANTY
Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or
workmanshipforaperiodof oneyearfrom thedateof originalpurchase.THERE ARENOOTHER WARRANTIES,EXPRESSOR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULARPURPOSE.
During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be
defective under normal use and service.
THISWARRANTYDOESNOT EXTEND TO FLUORESCENT LAMP STARTERSANDTUBES.Thiswarrantydoesnot cover (a)
normalmaintenance and service or(b)any products or parts whichhavebeen subject to misuse, negligence,accident,improper
maintenance or repair (other than by Broan), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not
allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND
EXCLUSIVEREMEDYUNDERTHISWARRANTY.BROANSHALLNOTBELIABLEFORINCIDENTAL,CONSEQUENTIALOR
SPECIALDAMAGESARISINGOUTOFORINCONNECTIONWITHPRODUCTUSEORPERFORMANCE.Somestatesdonot
allowtheexclusion or limitation ofincidentalorconsequentialdamages,so the above limitationorexclusionmaynotapply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty
supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan at the address stated below or telephone: 1-800-637-1453, (b) give the
model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting
warranty service, you must present evidence of the original purchase date.
BROAN MFG. CO., INC., 926 West State Street, Hartford, WI 53027
1
2
3
6
79
8
3
12
10
11
13
* Standard Hardware - May be purchased locally.
Always order replacement parts by “PART NO." - NOT by “KEY NO.”
1 99110454 Grille
2 99260428 #6-32 Sheet Metal Nut (2 req.)*
3 99170245 #8B x 3/8 Sheet Metal Screw (3 req.)*
4 97005322 Motor Mounting Bracket 97005322
5 99080199 Motor
6 99020125 Blade
7 98004932 Wiring Box Cover
8 99150471 #10-32 x 1/2 Green Ground Screw*
9 98005329 Wiring Box
10 97011741 Housing
11 99270982 Receptacle
12 99610012 Adjustable Duct
13 97011740 Wall Cap
DESCRIPTION
NO.
PART
NO.
KEY
1. Spingrilleontoitsmountingscrewuntilthe
grille is tight against the wall.
2. Turn on the power and check for proper
operation of ventilator.
USE AND CARE
WARNING: SWITCH OFF POWER AT SERVICE PANEL AND LOCK
SERVICE PANEL BEFORE CLEANING OR SERVICING THIS VENTI-
LATOR.
TO CLEAN FAN ASSEMBLY:
Unplug motor from black receptacle. Remove the motor assembly by
looseningthemountingscrewsandrotatingthemotorassemblyclockwise.
Gentlyvacuummotor assembly andinsideof housing.
METALANDELECTRICALPARTSSHOULDNEVERBEIMMERSEDIN
WATER.
PERIODICALLY CHECK THE OUTER LOUVER FOR ACCUMULATED
DUST,LINT, ETC.,WHICH MAYINTERFEREWITHPROPERLOUVER
CLOSURE.
WARNING: DO NOT SPRAY WATER INTO LOUVER-DAMAGE TO
THE FAN COULD OCCUR AND WATER COULD ENTER HOUSE.
MOTORLUBRICATION
Themotoris permanentlylubricated.Do not oilor disassemble motor.
SERVICE PARTS
Model512M
5
4
99041808D

Other Broan Fan manuals

Broan QTR140L User manual

Broan

Broan QTR140L User manual

Broan QTXE110S User manual

Broan

Broan QTXE110S User manual

Broan 678 User manual

Broan

Broan 678 User manual

Broan 349BR User manual

Broan

Broan 349BR User manual

Broan QTR070C User manual

Broan

Broan QTR070C User manual

Broan FRESH IN FIN-180B User manual

Broan

Broan FRESH IN FIN-180B User manual

Broan HD50L User manual

Broan

Broan HD50L User manual

Broan XB50 User manual

Broan

Broan XB50 User manual

Broan B6LC Manual

Broan

Broan B6LC Manual

Broan 655 Installation instructions manual

Broan

Broan 655 Installation instructions manual

Broan 345GOBK User manual

Broan

Broan 345GOBK User manual

Broan InVent 80 CFM Series Installation guide

Broan

Broan InVent 80 CFM Series Installation guide

Broan ZB90LC User manual

Broan

Broan ZB90LC User manual

Broan 157 User manual

Broan

Broan 157 User manual

Broan ERV200 ECM User manual

Broan

Broan ERV200 ECM User manual

Broan SOLITAIRE Series User manual

Broan

Broan SOLITAIRE Series User manual

Broan ULTRA SILENT QTXE080 User manual

Broan

Broan ULTRA SILENT QTXE080 User manual

Broan QTRE080C2S User manual

Broan

Broan QTRE080C2S User manual

Broan ZB110HL User manual

Broan

Broan ZB110HL User manual

Broan VENTILLATION FAN QTR100 User manual

Broan

Broan VENTILLATION FAN QTR100 User manual

Broan MP100 User manual

Broan

Broan MP100 User manual

Broan 355SOBK User manual

Broan

Broan 355SOBK User manual

Broan HUMIDITY SENSING FAN QTRE100S User manual

Broan

Broan HUMIDITY SENSING FAN QTRE100S User manual

Broan XB50L1 User manual

Broan

Broan XB50L1 User manual

Popular Fan manuals by other brands

Hunter 21538 Manual de Installatión y Operatión

Hunter

Hunter 21538 Manual de Installatión y Operatión

Hunter 21562 Parts guide

Hunter

Hunter 21562 Parts guide

Hunter 20081008 Owner's guide and installation manual

Hunter

Hunter 20081008 Owner's guide and installation manual

Somogyi home TF 32/BK instruction manual

Somogyi

Somogyi home TF 32/BK instruction manual

Hunter Leti installation manual

Hunter

Hunter Leti installation manual

NuAire MRXBOX95-WHIH Installation and Maintenance

NuAire

NuAire MRXBOX95-WHIH Installation and Maintenance

Elta Ezifit In-Wall SEIE Installation and maintenance instructions

Elta

Elta Ezifit In-Wall SEIE Installation and maintenance instructions

Martec Malibu Series installation guide

Martec

Martec Malibu Series installation guide

Lunos AB 30/60 installation instructions

Lunos

Lunos AB 30/60 installation instructions

Xpelair WX6 Installation and maintenance instructions

Xpelair

Xpelair WX6 Installation and maintenance instructions

S&P TD-1000/250 3V manual

S&P

S&P TD-1000/250 3V manual

ORIGO Crudus TF342 instruction manual

ORIGO

ORIGO Crudus TF342 instruction manual

Sealey STF29T instructions

Sealey

Sealey STF29T instructions

Pullman Holt F500 Specifications

Pullman Holt

Pullman Holt F500 Specifications

PASCO PS-6206 Product guide

PASCO

PASCO PS-6206 Product guide

AERMEC VED Technical manual

AERMEC

AERMEC VED Technical manual

Parrot Uncle BBHDA199A manual

Parrot Uncle

Parrot Uncle BBHDA199A manual

Hurricane CLASSIC 16" OSCILLATING WALL MOUNT FAN Instructions for use

Hurricane

Hurricane CLASSIC 16" OSCILLATING WALL MOUNT FAN Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.