TABLE OF CONTENTS
1. TECHNICAL DATA ...............................................................................................................4
1.1 AIR DISTRIBUTION (NORMAL OPERATION) .............................................................................................4
2. INSTALLATION....................................................................................................................4
2.1 LOCATING AND MOUNTING THE UNIT .....................................................................................................4
2.2 INSTALLING THE DUCTWORK AND THE REGISTERS.............................................................................6
2.2.1 Fully DucteD SyStem (t-1) (thiS conFiguration allowS recirculation moDe to operate.)............................6
2.2.2 exhauSt DucteD SyStem (t-2) (thiS conFiguration allowS recirculation moDe to operate.) .......................6
2.2.3 SimpliFieD inStallation (t-4) (thiS conFiguration DoeS not allow recirculation moDe to operate.) ..............7
2.3 CONNECTING THE DRAIN (HRV ONLY)....................................................................................................8
2.4 INSTALLING DUAL EXTERIOR HOOD USING TANDEM®TRANSITION KIT (OPTIONAL) .......................8
2.5 INSTALLING THE EXTERIOR HOODS .......................................................................................................9
2.6 CONNECTING THE DUCTS TO THE UNIT.................................................................................................9
2.6.1 DuctS connection .................................................................................................................................10
3. CONNECTIONS................................................................................................................. 11
3.1 ELECTRICAL CONNECTION TO OPTIONAL MAIN WALL CONTROL .................................................... 11
3.1.1 electrical connection to SpeeD, DehumiDiStat or automatic optional main wall control .........................
11
3.1.2 electrical connection to aDvanceD optional main wall control..............................................................
11
3.2 ELECTRICAL CONNECTION TO OPTIONAL AUXILIARY WALL CONTROL ...........................................12
3.2.1 electrical connection to 20-40-60 optional auxiliary wall control.......................................................
12
3.2.2 electrical connection to Dry contact optional auxiliary wall control (e.g. crank timer).....................
12
3.3 CONNECTION TO THE CENTRAL FORCED-AIR SYSTEM.....................................................................13
3.3.1 unit operation uSing aDry contact connection...................................................................................13
3.3.2 unit interconnection with central ForceD-air SyStem (r/c/g/gF).......................................................13
3.3.3 Synchronization with central ForceD-air SyStem Function...................................................................13
4. WIRING DIAGRAM ............................................................................................................14
5. NAVIGATION ON LCD SCREEN.......................................................................................15
5.1 DISPLAY ON LCD SCREEN......................................................................................................................16
5.2 UNIT FIRST BOOT.....................................................................................................................................16
5.3 SETTINGS MODIFICATION.......................................................................................................................16
5.3.1 proceDure to moDiFy min cFm Setting....................................................................................................16
5.3.2 proceDure to moDiFy max cFm Setting...................................................................................................16
5.3.3 proceDure to moDiFy optionS Setting...................................................................................................16
5.3.4 proceDure to moDiFy inDepenDent airFlowS Setting..............................................................................16
5.4 FACTORY SETTINGS RESET...................................................................................................................17
6. USING THIS UNIT..............................................................................................................17
6.1 YOUR VENTILATION SYSTEM ..................................................................................................................17
6.2 INTEGRATED CONTROL ..........................................................................................................................17
6.3 AHU MODE DISPLAY ................................................................................................................................17
7. SERVICE PARTS................................................................................................................18
8. INSTALLER’S TROUBLESHOOTING ...............................................................................20
9. MAINTENANCE.................................................................................................................23
9.1 QUARTERLY ..............................................................................................................................................23
9.2 ANNUAL (AT FALL) ....................................................................................................................................24
10. USER’S TROUBLESHOOTING .......................................................................................24
11. WARRANTY......................................................................................................................25