Troubleshooting Guide Version 021 BRUKER BIOSPIN 3
Contents
Contents ............................................................................ 3
1 Installation Problems ......................................................... 5
1.1 Sample Eject (Lift) Problems .............................................................. 5
Sample lift air flow ..........................................................................5
Sample holder tray slamming ..........................................................5
Light barrier ....................................................................................5
Seals ..............................................................................................6
Seating of the adapter collar ...........................................................6
Alignment of the adapter collar, seal ring and brown interface tube ..6
Sample lift air bypass ......................................................................6
Interface tube inside the adapter collar ............................................6
1.2 Sample Insert (Down) Problems ......................................................... 7
NMR CASE or magnet not level ......................................................7
BST shim stack with sharp edges ....................................................7
Sample lift air bypass ......................................................................7
Too much sample lift air flow ...........................................................8
Sample holder tray does not advances firmly ..................................8
Alignment of the adapter collar, seal ring and brown interface tube ..8
Interface tube inside the adapter collar ............................................8
1.3 Sample holder tray does not advance at all ......................................... 9
1.4 The sample holder tray advances when the eject air is turned OFF ..... 9
1.5 The motion controller does not work ................................................. 10
1.6 The sample holder tray slams samples when advancing ................... 12
1.7 The adapter collar does not fit to the shim stack ............................... 12
1.8 The NMR CASE does not fit ............................................................. 12
1.9 The sample spin rate goes up to 150 Hz ........................................... 13
1.10 Intermittent problems ........................................................................ 13
1.11 Sample lift (eject) sometimes hangs on top of the BST and does NOT go
up into the NMR Case ......................................................................13
1.12 Sample lift (eject) always hangs on top of the BST and does NOT go up
into the NMR Case ...........................................................................14
1.13 Sample lift (eject) hangs just below the top of the sample holder tray 14
1.14 Sample insert (down) sometimes hangs on top of the sample holder tray
..........................................................................................................14
1.15 Sample insert (down) sometimes hangs at the white ring on top of the
adapter collar ................................................................................... 14
1.16 The sample holder tray does not advance away from position 0 ........ 15
1.17 Sometimes the tray rotates in the wrong direction ............................. 15
1.18 Sometimes the tray does not rotate ................................................... 15
1.19 Sometimes samples stuck in brown interface tube (inside the adapter col-
lar) ................................................................................................... 16