Brymen BM035 User manual

Eshop: www.emareg.cz Email: [email protected]
USER'SMANUAL
Mìøící a dílenské pøístroje / Kleové multimetry
uvádí:
BRYMEN BM037, BM035, BM033, BM031
BRIGHTPEOPLESCHOICE

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
1
Themeter meets UL/IEC/EN610101Ed. 3.0, CAN/CSAC22.2No.61010 1 Ed.3.0,
UL/IEC/EN610102032 Ed. 3.0, UL/IEC/EN610102033 Ed. 1.0 to Measurement
CATIII 600VandCATIV 300V,AC&DC.
The accompanied test probeassemblymeetsUL/IEC/EN61010 031 Ed.2.0to the
samemeterratingsorbetter. IEC61010031requiresexposedconductivetestprobe
tipstobe 4mmforCATIII&CATIVratings.Refertothecategorymarkingsonyour
probeassembliesaswellasontheadd onaccessories(likedetachableCapsor
AlligatorClips),ifany,forapplicableratingchanges.
identifiesconditionsandactionsthatcouldresultinseriousinjuryoreven
deathtotheuser.
identifiesconditionsandactionsthatcouldcausedamageormalfunction
intheinstrument.
Thismanualcontainsinformationandwarningsthatmustbefollo wedforoperatingthe
meter safelyandmaintainingthe meter inasafeoperatingcondition.Ifthe meter is
usedinamannernotspecifiedbythemanufacturer,theprotectionprovidedbythe
meter maybeimpaired.
Observepropersafetyprecautionswhenwo rkingwithvoltagesabove3 0 Vrms,42.4
Vpeakor 60VDC.Thesevoltagelevelsposeapotentialshockhazardtotheuser. Do
notexposethisproducttorainormoisture.Themeterisintendedonlyforindooruse.
Keepyourhands/fingersbehindthehand/fin gerbarriers(ofthemeterandthetest
probeassembly,whereapplicable)thatindicatethelimitsofsafeaccessofthehand
held parts during measurements. Inspect lead wires, connectors, and probes for
damagedinsulationorexposedmetalperiodically.I fanydefectsarefound,replace
themimmediately. Optionaloffer premiumsilicon test leadwires
equipwith whiteinner insulation layeraswearindicator. Donot usethem ifthewear
indicatorhasbecomevisible . Onlyusetheprob eassemblyprovidedwiththemeteror
aULListedProbeAssemblytothesamemeterratingsorbetter.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
2
Marking ofElectricalandElectronicEquipment (EEE). Donotdisposeofthis
productasunsortedmunicipalwaste. Contactaqualifiedrecycler
Caution!RefertotheexplanationinthisManual
Caution! Possibility ofelectricshock
Earth(Ground)
Meterprotectedthroughout by DoubleInsulationorReinforcedinsulation
Fuse
Direct Current(DC)
AlternatingCurrent (AC)
Threephase Alternating Current
Applicationaroundandremovalfromhazardousliveconductorsispermitted
isapplicable totestandmeasuringcircuitsconnectedat
voltage MAINS installation. Examples are
measurementsondevicesinstalledbeforethemainfuseorcircuitbreakerinthe
buildinginstallation.
isapplicabletotestandmeasuringcircuitsconnectedto
voltageMAINSinstallation.Examplesare
measurementsondistributionboards(includingsecondarymeters),circuit breakers,
cables, busbars,junctionboxes,swi tches, socketoutlets,stationarymotors in the
fixedinstallation,andequipmentforindustrialuse.
isapplicabletotestandmeasuringcircuitsconnected
directlytoutilizationpoints(socketoutletsandsimilarpoints)ofthel owvoltage MAINS
installation. Examples are measurements on MAINS CIRCUITS of household
appliances,portabletoolsandsimilarequipment.
The instruments conform to CENELEC Lowvoltage directive 2014/35/EU,
Electromagneticcompatibility directive2014/30/EU andRoHSdirective 2015/863/EU.
Thisuser'smanualusesonlyrepresentativemodel(s)forillustrations.Pleaserefer
specificationdetailsforfunctionavailabilitytoeachmodel.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
3
1) Antenna area for NonContactEF
Detection
2) Jaw center indicator (with DCA
polarityforModels037&035), atwhere
best current accuracyisspecified
3) Pushbuttonsforspecialfunctions&
features.
4) Rotary Selector to turn the power
ON/OFF andselectafunction
5) 35/6 digits 6000 counts numeric
LCD display
6) InputJackforallfunctionsEXCEPT
noninvasive Currentfunctions
7) Common (Ground reference) Input
Jack for all functions EXCEPT the
Clampon Current andNonContactEF
Detection functions
8) Jawtriggerforopeningtheclampjaw
9) Hand/FingerBarriertoindicatethe
limitsofsafeaccessofthemeter
10) Clamp Jaw for Clampon Current
magnetic fieldpickup
11) Additional center indicator for AmpTipTM Lowcurrent functions,atwherebest
AmpTipTM currentaccuracyisspecified
Beforeandafterhazardousvoltagemeasurements,testthevoltagefunctionona
knownsourcesuchaslinevoltagetodeterminepropermeterfunctioning

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
4
Inputs are madethroughthetestlead terminals . Defaults at Function.
Press button momentarilyto select function.
Note:
and functionsareequippedwithlow passfilter,andarecapableof
dealing with (VariableFrequencyDrives)signals. Italsoimprovesreadingstability
innoisyelectricalenvironments.
Inputsaremadethroughthetestlead terminals .
Pressthejawtriggerandclampthejawsaroundconductor(s)ofonlyonesinglepoleof
acircuitforloadcurrentmeasurement s.Makesurethejawsarecompletelyclosed,or
elseitwillintroducemeasurementerrors.Enclosi ng conductor(s) of more than one
pole ofacircuit may resultindifferentialcurrent(likeidentifyingleakagecurrent)
measurements. Align the conductor(s) to the Jaws center indicators (Regular or

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
5
AmpTip indicatorswhereapplicable)as muchaspossibletogetthebestmeasuring
accuracy. For removal, press the jaw trigger and remove the jaws from the
conductor(s).
Adjacentcurrent carryingdevicessuchastransformers,motorsandconductorwires
may affect measurement accuracy. Keep the jaws away from them as much as
possibletominimizeinfluence.
This Clamponmeterseriesisdesignedtodirectlyapplyaroundorremovefrom
uninsulatedhazardousliveconductors.Butstill,individualprotectiveequipmentmust
beusedifhazardouslivepartsintheinstallationwheremeasurementistobecarried
outcouldbeaccessible. Donotusethemetertomeasurecurrentsabovetherated
frequency(400Hz).C irculatingcurrents may cause themagneticcircuitsoftheJaws
reachahazardoustemperature.
Input is made via theclampjaws wherebestaccuracyisspecifiednearthe jaw TIP
CENTER area for lowcurrentmeasurementsofthin conductors. Defaults at .
Press buttonmomentarilyto select forModels035&037.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
6
Input is made via theclampjaws wherebestaccuracyisspecifiedatthe jaw CENTER
area. Defaultsat . Press buttonmomentarilyto select forModels
035&037.
Inputsaremadethroughthetestlead terminals . Defaults at .
Press buttonmomentarilyto select thesubject functions insequence. For
Models035&031, function islocated inanindependentrotary
switchposition
This function is having improved convenience forcheckingwiringconnectionsand
operationofswitches. Resistancethresholdisbeingused. A continuous beep tone
togetherwithflashing display backlight indicateacompletewire. Such audible and
visibleindicationsimprovecontinuityreadabilities innoisyworkingenvironments.
Forwardvoltagedrop(forwardbiased)foragoodsilicondiode
isbetween0.400Vto0.900V.Ahigherreadingindicatesaleakydiode(defective).A

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
7
zeroreadingindicatesashorteddio de(defective).Anover rangedisplayindicatesan
opendiode(defective).Reversethetestleadsconnections(reversebiased)acrossthe
diode.Thedigitaldisplayshowsover rangeifthediodeisgood.Anyotherreadings
indicatethediodeisresistiveorshorted(defective).
Whenthedisplayreadingdropsacross0.850V,
themeteralertsashortbeeptosignalareasonableforwardvoltagedropofcommon
diodes. However, if the reading further drops below 0.100V, the meter gives a
continuous beeptonetogetherwithflashingdisplaybacklighttoindicateashorted
diodeoracompletewire.Itissimilartothatof function but
,instead,isbasedonvoltagethresholdtoindicateacompletewire.
Using , or functioninalivecircuit
willproducefalseresultsandmaydamagethe meter.Inmanycases , thesuspected
component(s) must be disconnected from the circuit to obtain an accurate
measurementreading.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
8
Defaults at highsensitivity . T Ifitistoo
sensitiveforyourapplications,press button momentarily to select lower
sensitivity .ThedetectedElectricField strengthisindicatedasaseriesofbar
graphsegmentsonthedisplayplusvariablebeeptones.
Anantennaislocatedalongthetop rightend of
the stationaryclampjaw ,whichdetectselectricfieldsurrounds energized conductors.
Itisidealfortracinglivewiringconnections,locatingwiringbreakageandtodistin guish
betweenliveorearthconnections.
Formorepreciseindicationoflivewires,suchas
distinguishingbetween Liveand Groundconnections,use onesingle probe to test via
terminal for direct metal ProbeContact EFDetection to achieve the most
distinctiveindication.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
10
Inputsaremadethroughthetestlead terminals / . Defaults at
function. Press button momentarilytwotimes to select function.
The functionisdesignedespeciallyforHVAC/Rflamesensorapplications.The
0.1 Aresolutionisusefulforidentifyingtheminutecurrentchangesinflamedetector
applications.Flamesignalcurrentcheckshouldindicatesteadyflame signalofatleast
2 Aforarectificationtype,or1.5 Aforanultraviolettype(8 Aforselfchecking
systems).Ifaflamesignalcurrentwithinadequatestrengthorfluctuationbeyond10%,
checkthefollowingtoavoidtheriskofunwantedflamerelaydropout:
Forgasoroilflames(Minipeeper):
Lowsupplyvoltage
Detectorlocation
Defectivedetectorwiring
Dirtyviewingwindows
FaultyMinipeeper
Foroilflames(Photocell):

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
11
Detectorlocation&wiring
Smokyflameorpoorlyadjustedairshutter
FaultyPhotocell
Temperature over 165oF (74oC)atphotocell
Forgasflames(FlameRod):
Ignitioninterference(Aflamesignalcurrentdifferencewiththeignitionbothon
andoffgreaterthan0.5 Aindicatesthepresenceofignitioninterference)
Insufficientground(mustbeatleast4timesthedetectorarea)
Flameliftingoffburnerhead(ground),ornotcontinuouslyincontactwiththe
flame rod
Temperatureinexcessof600 oF (316 oC)attheflameelectrodeinsulator
causingshorttoground.
Inputsaremadethroughthetestlead terminals / . Defaultsat .
Press button momentarily to select (Celsius) and (Fahrenheit) in
sequence ( selection can beleftout asfactory calibration default forcountriesthat
onlyacceptmetricunits).
Besuretoinsertthebananaplugtype KtemperaturebeadprobeBkp60withcorrect
polarities.Bananapinstotype KsocketadapterBkb32(Optionalpurchase)can
beusedtoacceptothertypeKprobesusingstandardminiatureplug.
Temperature accuracies assume meter interior has the same temperature of the
ambient(isothermalsta ge)foracorrectjunctionvoltagecompensation.Allowthe
meterandthetype Kprobesettoreachisothermalstageforasignificantchangeof
ambienttemperature.Itcantakeuptoanhourforchanges>5°C.
Discharge capacitor(s) before making capacitance measurements. Large value
capacitors should be discharged through an appropriate resistance load. Using
Capacitancefunctioninalivecircuitwillproducefalseresultsandmaydamagethe
meter.Inmanycasesthesuspectedcomponent (s) must be disconnectedfromthe
circuittoobtainaccuratemeasurementreadings.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
13
feature freezesthedisplayforlaterview. LCD turnson. Pressthe
buttonmomentarilytotoggle the feature.
mode allowstheusertooffsetthemeterconsecutivemeasurements
with the main display displayingreadingasthereferencevalue. LCD turns on.
Press the ( ) button foronesecond or moreto toggle mode. When
in functions(Models035&037only),however, mode instead willbe
activated.
mode (Models035&037only) isafeature to temporarily offset
residue readings caused byresidualmagneticfield of the jawsin functions. Press
the ( ) button foronesecond ormore to apply. Themeter displays
oneach activation before continuing measurements.Applythis mode repeatedly to get
azero reading beforemakingany measurementsforbestmeasuringaccuracy.
The meterwillgive 3shortbeeps,however,towarnfornullactivationifthe display
reading isbeyondareasonableresidue of 5to5DCA.
Press buttonmomentarilytoactivate recording mode.LCD &
turnon.Themeterbeepswhennew (maximum) or (minimum) reading is
updated. Pressthebuttonmomentarilytoreadthe , ,and (active
measurement) readings insequence. Pressthebuttonfor1second ormore to exitthis
mode. AutoPowerOff is disabledautomaticallyinthismode.
Press button foronesecond ormore to activate mode (Instantaneous
PEAKHOLD) tocapture currentor voltage peakvaluesin durationasshortas 5ms.
LCD & turnon.Themeterbeepswhennew (maximum) or
(minimum)readingisupdated . Pressthebuttonmomentarilyto toggle the and
readings. Pressthebuttonfor1second ormore to exit this mode.AutoPower
Off is disabledautomaticallyinthismode.
Press the buttonfor1second ormore to toggle the LCD backlight. The
modeturnstheLCDbacklightoffautomatically after idling for 10 minutes to extend
batterylife. See section for disabling .

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
14
The modeturnsthemeteroffautomaticallytoextendbatterylifeafter idling 32
minutesofnospecifiedactivities,whereapplicable,below:
1) Rotaryswitchorpushbuttonoperations
2) Significantmeasuringreadingsofabove8.5%ofranges
3) Nonoverrange readings for Resistance,ContinuityorDiodefunction
4) NonzeroreadingsforHzfunction
Inotherwords,themeterwilli ntelligently reset the modewhenitisundernormal
measurements. To wake up the meter from , press the button
momentarily andrelease, orturnthe rotary switchOFFandthenbackon.Alwaysturn
the rotary switchtotheOFFpositionwhenthe meterisnotinuse.
Pressandhold the button whilepoweringon themeter can disable both
and features temporarilyduringthepoweronsession . The LCD will display
toconfirmselectionbefore the button isreleased.
Pressandhold the button whilepoweringon themeter can shortenthe
idlingtimeto5seconds temporarilyduringthepoweronsession .Itisdesignedmainly
for productioninspection.
Pressandhold the button whilepoweringon themeter can holdandshowall
LCDsegmentsb efore the button is released.Itisdesignedmainlyforproduction
inspection.
Toavoidelectricalshock,disconnect themeterfromanycircuit,removethetestleads
fromtheinputjacksandturnOFFthemeterbeforeopeningthecase.Donotoperate
withopencase.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
15
Iftheinstrumentfailstooperate,checkbatteriesandtestleadsetc.,andreplaceas
.
Refer to the LIMITED WARRANTY section for obtaining calibration, repairing or
warrantyservice.
Accuracyisspecifiedforaperiodofoneyearafter calibration. Periodiccalibrationat
intervalsofoneyearisrecommendedtomaintainmeteraccuracy.
Periodicallywipethemeterandthetestprobeassemblywithadampclothandmild
detergent.Donotuseabrasivesorsolvents.Allo wtodrycompletelybeforeoperating.
Ifthemeterisnottobeusedforperiodsoflongerthan60days,removethe batteries
and storethem separately
Themeterusesstandard1.5VAAA Size(IECR03)batteryX2
Loosenthe 2 captivescrewsfromthe bottom case.Liftthe bottom case. Replacethe
batteries. Replacethebottom case.Refastenthescrews.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
16
35/6digits6000counts
Automatic
5persecondnominal
0 C to40 C
Maximum relative humidity 80% for temperature up to 31 C
decreasinglinearlyto50%relativehumidityat40 C
2
20 Cto60 C,<80%R.H.(withbatteryremoved)
Operatingbelow2000m
nominal0.1x(specifiedaccuracy)/ C@(0 C 18 Cor
28 C 40 C),orotherwisespecified
TrueRMS
Certified per IEC/UL/CSA_C22.2_#/EN standards:
610101Ed. 3.0, 610102032 Ed.3.0,610102033 Ed. 1.0&61010031 Ed.2.0 to
Measurement CategoriesCATIII600VandCATIV300Vac & dc
6.0kV(1.2/50 ssurge)
Currentvia jaws: 600Adc/Aac rms at<400Hz
Voltageviaterminals:660Vdc /920Vac rms
Otherfunctions viaterminals: 600Vdc/Vac rms
MeetsEN613261:2013
DCAandACAFunctions,inanRFfieldof1V/m:
Total Accuracy= Specified Accuracy+ 40 digits ataround87MHz
DC AandOhmFunctions,inanRFfieldof1V/m:
Total Accuracy= SpecifiedAccuracy + 25 digits
OtherFunctions,inanRFfieldof3V/m:
Total Accuracy= Specified Accuracy+ 20 digits
1.5VAAASizebatteryX2
Typical 14mA forCurrentfunctions ofModels037& 035;4mA
for others
Belowapprox.2.85V forCapacitance&Hz
Belowapprox.2.5V forotherfunctions
Idlefor32 minutes
5 Atypical
188x66x32mm

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
17
202gforModels037&035;158gforModels033&031
26mmmax
Testlead set, User'smanual, Softcarryingpouch, Bkp60bananaplug
typeK thermocouple(Models037&033 only),
BKB32bananaplugtotypeKsocketplugadaptor
(Models037&033 only)
AmpTipTM lowcurrentrange;MAX/MINRecordingmode; MAX/MIN
Crest (PeakHold) mode; RelativeZero mode; Display Hold; EFDetection (NCV);
BeepLitTM Feature
Accuracyis (%readingdigits+numberofdigits)o rotherwisespecified,at23 C
5 C.
MaximumCrestFactor< 2 : 1atfullscale&< 4 : 1athalfscaleorotherwisespecified,
andwith frequencyspectrumnotexceeding thespecifiedfrequencybandwidthfornon
sinusoidalwaveforms.
RANGE Accuracy
600.0V 1.0% + 5d
InputImpedance:10M , 100pFnominal
RANGE Accuracy
50Hz ~60Hz
600.0V 1.5%+5d
InputImpedance:10M , 100pFnominal
Applicability: Voltage and NoninvasionCurrent functions
Accuracy:Add +/ 250digitstospecifiedaccuracyforchanges>5ms induration
ContinuityThreshold:Between30 and 480
Continuity ONResponse Time: 15ms approx.
AudibleIndication:Beepsound
Visible Indication:LCDBacklight

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
18
RANGE Accuracy
600.0 , 6.000k (Allmodels) 1.0% + 5d
60.00k , 600.0k , 6000k (Models037&033only)
Open Circuit Voltage:1.0VDCtypical
RANGE Accuracy 1)
200.0 F, 2500 F 2.0% + 4d
1)Accuracies withfilmcapacitororbetter
RANGE Accuracy
3.000V 1.5% +5d
TestCurrent:0.3mAtypically
OpenCircuitVoltage:<3.5VDCtypically
Short Beep Alert Threshold:Dropacross0.850V
: <0.100V
AudibleIndication:Beepsound
VisibleIndication: LCDBacklight
RANGE Accuracy BurdenVoltage
200.0 A,2000 A 1.0% + 5d 3.5mV/ A

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
19
RANGE Accuracy 1)2)
40.0 oC~99.9 oC 1.0% + 1.0oC
100 oC~400 oC 1.0% + 1oC
40.0 oF ~211.8 oF 1.0% + 2.0oF
212 oF~752 oF 1.0% + 2oF
1)Accuraciesassumemeterinteriorhasthesametemperatureoftheambient
(isothermalstage)foracorrectjunctionvoltagecompensation.Allowthe meter and
the typeK probeset toreachisothermalstageforasignificantchangeofambient
temperature.Itcantakeuptoanhourforchanges>5°C.
2)TypeKthermocouplerange&accuracynotincluded
RANGE Accuracy1)
50Hz ~60Hz
60.00A 1.0% + 5d
1)Inducederrorfromadjacentcurrentcarrying conductor:
<0.01A/A forModels037,035
<0.06A/A forModels033,031
RANGE Accuracy1)2) 3)
60.00A 1.0% + 5d
1)Inducederrorfromadjacentcurrentcarryingconductor:<0.01A/A
2)SpecifiedwithDCZeromode appliedtooffsetthenonzeroresidualreadings,ifany
3)Add5dtothespecifiedaccuracy@< 4A
This manual suits for next models
3
Other Brymen Multimeter manuals

Brymen
Brymen BM905s User manual

Brymen
Brymen BM878 User manual

Brymen
Brymen BM157 User manual

Brymen
Brymen BM839 User manual

Brymen
Brymen BM867s User manual

Brymen
Brymen BM859s User manual

Brymen
Brymen BM161 User manual

Brymen
Brymen TBM061 User manual

Brymen
Brymen EEVblog BM235 User manual

Brymen
Brymen TBM161 User manual

Brymen
Brymen BM805s User manual

Brymen
Brymen BM230 Series User manual

Brymen
Brymen BM857 User manual

Brymen
Brymen BM885 User manual

Brymen
Brymen BM170D Series User manual

Brymen
Brymen BM061s User manual

Brymen
Brymen TopTronic TBM315 User manual

Brymen
Brymen BM161s User manual

Brymen
Brymen BM789 User manual

Brymen
Brymen BM252 User manual