Thismanualcontainsinformationandwarningsthatmustbefollowedforoperatingthe
metersafelyandmaintainingthemeterinasafeoperatingcondition.Ifthemeteris
usedinamanner notspecifiedbythemanufacturer,theprotectionprovidedbythe
metermaybeimpaired.
identifiesconditionsandactionsthatcouldresultinseriousinjuryoreven
deathtotheuser.
identifiesconditionsandacti onsthatcouldcausedamageormalfunction
intheinstrument.
Toreducetheriskoffireorelectricshock,donotexposethisproducttorainor
moisture.Themeterisintendedonlyforindooruse.
Observepropersafetyprecautionswhenworking withvoltagesabove33Vrms,46.7
Vpeakor70VDC.Thesevoltagelevelsposeapotentialshockhazardtotheuser.
Beforeandafterhazardousvoltagemeasurements,checkthevoltagefunctionona
knownsourcesuchaslinevoltagetodeterminepropermeter functioning.
Themeter meets UL/IEC/EN610101Ed. 3.0, CAN/CSAC22.2No.61010 1 Ed.3.0,
UL/IEC/EN610102033 Ed. 1.0 toMeasurementCATIII1kVandCAT IV600V,AC&
DC.
The accompanied test probeassemblymeetsUL/IEC/EN61010 031 Ed. 1.1 to the
same meterratingsorbetter. IEC61010031requiresexposedconductivetestprobe
tipstobe 4mmforCATIII&CATIVratings.Refertothecategorymarkingsonyour
probeassembliesaswellasontheadd onaccessories(likedetachableCapsor
AlligatorClips),ifany,forapplicableratingchanges.
Keepyourhands/fingersbehindthehand/fing erbarriers(ofthemeterandthetest
probeassembly, whereapplicable)thatindicatethelimitsofsafeaccessofthehand
held parts during measurements. Inspect lead wires, connectors, and probes for
damagedinsulationorexposedmetalbeforeusingthe meter.Ifanydefectsarefound,
replacethemimmediately.Onlyusetheprobeassemblyprovidedwiththemeterora
ULListedProbeAssemblytothesamemeterratingsorbetter.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
Disconnectthetestleadsfromthetestpointsbeforechangingfunctions.
MarkingofElectricalandElectronicEquipment(EEE).Donotdisposeofthis
productasunsortedmunicipalwaste.Contactaqualifiedrecycler
Caution!RefertotheexplanationinthisManual
Caution!Possibilityofelectricshock
Earth(Ground)
MeterprotectedthroughoutbyDoubleInsulationorReinforcedinsulation
Fuse
DirectCurrent(DC)
AlternatingCurrent(AC)
3 ThreephaseAlternatingCurrent
isapplicabletotestandmeasuringcircuitsconnectedat
voltage MAINS installation. Examples are
measurementsondevicesinstalledbefore themainfuseorcircuitbreakerinthe
buildinginstallation.
isapplicabletotestandmeasuringcircuitsconnectedto
voltageMAINSinstallation.Examplesare
measurementsondistribu tionboards(includingsecondarymeters),circuit breakers,
wiring,includingcables,bus bars,junctionboxes,switches,socket outletsinthefixed
installation,andequipmentforindustrialuseandsomeotherequipmentsuchas
stationarymotorswithpermanentconnectiontothefixedinstallation.
isapplicabletotestandmeasuringcircuitsconnected
directlytoutilizationpoints(socketoutletsandsimilarpoints)ofthelow voltage MAINS
installation. Examples are measurements on MAINS CIRCUITS of household
appliances,portabletoolsandsimilarequipment.
The instruments conform to CENELEC Lowvoltage directive 2014/35/EC,
Electromagneticcompatibilitydirective2014/30/EU andRoHSdirective2011/65/EU.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
Note:Topofthelinemodelisusedasrepresentativeforillustrationpurposes.Please
refertoyourparticularmodelforfunctionavailability.
Theanalogbargraphprovidesavisualindicationofmeasurement likeatraditional
analog meter needle. It is excellent in detecting faulty contacts, identifying
potentiometerclicks,andindicatingsignalspikesduringadjustments.
1) 41/2 digits 20000
counts &35/6 digits 6000
counts selectable dual
displays
2)Pushbuttons forspecial
functions&features
3)Selectorto turn the
PowerOnorOffandSelect
afunction
4)InputJackfor mA/µA
functionpositiveinput
5)Common (Ground
reference)InputJackforall
functions
6)InputJackforall
functions EXCEPTA, mA
and µA functions
7) Input JackforA function
positiveinput

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
Beforeandafterhazardousvoltagemeasurements,testthevolta gefunctionona
knownsourcesuchaslinevoltagetodeterminepropermeterfunctioning.
Pressthe buttonmomentarilytotoggle the subjectfunctions. Lastselection
willbesavedaspowerupdefaultforrepeatmeas urementconvenience. For
function,pressthe buttonmomentarilytoselectotherranges manually when
needed.For function, defaultissetto 600Vrangetobestcopewiththe
measurementsofmostVariableFrequencyDrives(VFD). Press the button
momentarily toselect1000V rangewhenneeded.
TurnRotaryKnobto functionpositionformeasurements.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
Pressthe buttonmomentarilyto select the subject functions.Lastselection
willbesavedaspowerupdefaultforrepeatmeasurementconvenience.
functionis havingimproved convenience forcheckingwiring
connectionsandoperationofswitches.Acontinuousbeeptone togetherwithflashing
display backlightindicateacompletewire. Suchaudibleandvisibleindicationsimprove
continuity readabilities innoisyworkingenvironments.
Conductance istheinverseofResistance,thatisS=1/ or nS=1/G .Itvirtually
extends the Resistance measurements to the order of GigaOhms for leakage
measurements.
Usingresistance, continuity or nS functioninalivecircuitwillproducefalseresults and
may damage the instrument. In many cases the suspected component must be
disconnectedfromthecircuittoobtainanaccuratereading

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
Whenenteringthe 200 range manually by buttonforhighprecisionlow
resistancemeasurement,this featurewillpromptyoutoshorttheinputsfor temporary
testlead resistance calibration onthisrange.
The fastestwayisto shorttheleadstoauto rangetothe 200 range, thenpress the
button momentarily. Thedisplaysho Keepshortingtheleads for
further 3secondsuntilthedisplayshowszero . Theleadresistanceisthen temporarily
compensated.
Thecompensationvaluestaysuntilthenextmeterpowerreset,and canbeashigh as
5 .Ifyouneedacompensation valuethatishigherthanthat,Relative Zero modeis
recommended.
Pressthe buttonmomentarilytotoggle the functions. Lastselectionwillbe
savedaspowerupdefaultforrep atmeasurementconvenience.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
Dischargecapacitorsbeforemakinganymeasurement.Largevaluecapacitorsshould
bedischargedthroughanappropriateresistanceload.
Normalforwardvoltagedrop(forwa rdbiased)foragoodsilicondiodeisbetween
0.400Vto0.900V.Areadinghigherthanthatindicatesaleakydiode(defective).A
zeroreadingindicatesashorteddiode(defective).AnOLindicatesanopendiode
(defective).Reversethetestleadsconnect ions(reversebiased)acrossthediode.The
digitaldisplayshowsOLifthediodeisgood.Anyotherreadingsindicatethediodeis
resistiveorshorted(defective).

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
Pressthe buttonmomentarilytotoggle the subjectfunctions. Lastselection
willbesavedaspowerupdefaultforrepeatmeasurementconvenience.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
Press buttonmomentarilytotoggle C and Freadings.Lastselectionwillbe
savedaspowerupdefaultforrepeat measurementconvenience.
Note:Besuretoinsertthebananaplugtype KtemperaturebeadprobeBkp60with
correct polarities.YoucanalsouseaplugadapterBkb32(Optionalpurchase)
with banana pins to typeK socket to adapt other standard typeK mini plug
temperature probes.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
µ
Press the buttonmomentarilytotoggle the or of the subject
functions. Lastselectionwillbesavedaspowerupdefault forrepeatmeasurement
convenience.
Pressthe buttonfor1secondormoretotoggletheLCDbacklight.Thebacklight
willalsobeturnedoffautomaticallyafterapproximate10minutes toextendbatterylife.
Press the buttonmomentarilytoselectmanual ranging,andthemeterwill
remainintherangeitwasin,theLCD turnsoff.Pressthebuttonmomentarily
againtoselectanadjacentrange.Pressandholdthebuttonfor1secondormoreto
resumeautoranging.
RelativeZeroallowstheusertooffsetthemeterconsecutivemeasurementswiththe
maindisplay displayingreadingasthereferencevalue. LCD turnson. Pressthe
button momentarily to toggleRelativeZeromode.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
Theholdfeaturefreezesthedisplayforlaterview. LCD turnson. Pressthe
buttonmomentarilytotoggletheholdfeature.
Pressthe button foronesecondormoreto togglebetweenthe Standard
6000 counts and 20000 counts High Resolution modes. Theanalogbar graph full
scale shows and accordingly. Last selectionis savedaspowerupdefault.
20000 counts High Resolution modeisavailabletoAC/DCVoltage(exceptVFD
ACV+Hz),AC/DCCurrentandResistancefunctions.
Press
turnon.ThemeterbeepswhenanewMAX(maximum)orMIN(minimum)
readingisupdated.PressthebuttonmomentarilytoreadtheReal time,MAXandMIN
readings in sequence. Press the button for 1 second or more to exit MAX/MIN
recordingmode.Whenactivated,AutoPowerOffisdisabledautomatically.
Press buttonmomentarilytoactivateCREST(InstantaneousPeakHold) mode
tocapturevoltageorcurre ntsignaldurationasshortas 5ms.
turnon.PressthebuttonmomentarilytoreadtheMAX and MIN readings insequence.
Press the button for 1 second or more to exit CREST mode. AutoPowerOff is
disabledautomaticallyinthismode.
or inputjackwhenother

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
functions,especiallyvoltagefunction,isselected.
Pressthe buttonwhileturningthemeterontotemporarilydisabletheBeeper
feature.TurntherotaryswitchOFFandthenbackontoresume.
The AutoPoweroff (APO)modeturnsthemeteroffautomaticallytoextendbattery life
afterapproximately20minutesofnorotaryswitchorpushbuttonoperations.Towake
upthemeterfromAPO,pressthe or buttonmomentarilyorturnthe
rotaryswitchOFFandthenbackon.AlwaysturntherotaryswitchtotheOFFpositio n
whenthemeterisnotinuse.
Pressthe buttonwhileturningthemeterontotemporarilydisabletheAuto
PowerOfffeature.TurntherotaryswitchOFFandthenbackontoresume.
Toavoidelectricalshock,disconnectthemeterfromanycircuit,removethetestleads
fromtheinputjacksandturnOFFthemeterbeforeopeningthecase.Donotoperate
withopencase.Installonlythesametypeoffuseorequivalent
Accuracyisspecified foraperiodofoneyearaftercalibration.Periodiccalibrationat
intervalsofoneyearisrecommendedtomaintainmeteraccuracy.
Periodicallywipethe meterandthetestprobeassembly withadampclothandmild
detergent. Donot useabrasivesorsolvents. Allowtodrycompletelybeforeoperating.
Ifthemeterisnottobeusedforperiodsoflongerthan60days,removethebattery
andstoreitseparately
Iftheinstrumentfailstooperate,checkbattery,fuses, leads,etc.,andreplaceas
.
RefertotheLIMITEDWARRANTYsectionforobtainingwarrantyorrepairingservice.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
Four 1.5V AAalkaline batteries (IECLR6)
Fuse(F2) for input:
0.4A/1000Vac&Vdc,IR30kA,Ffuse; orbetter. Dimension:6x32mm
Fuse(F3) forA input:
11A/1000Vac&Vdc, IR20kA,Ffuse; orbetter. Dimension: 10 x38 mm
Loosenthescrewsfromtheaccesscoverofthecasebottom.Lifttheaccesscover.
Replacethebatteriesorfuse.Refastenthescrews.

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
35/6digits6,000counts&41/2 digits 20,000 counts max
Automatic
5persecondnominal
5persecondnominal
40persecondmax
10 C to50 C
Maximumrelativehumidity90%fortemperatureupto28 C
decreasinglinearlyto50%relativehumidityat50 C
2
IP40
20 Cto60 C,<80%R.H.(withbatteryremoved)
Operatingbelow2000m
nominal0.1x(specifiedaccuracy)/ C@(10 C~18 C or
28 C ~50 C),orotherwisespecified
ACTrueRMS
ETLcertified perIEC/UL/EN610101Ed.3.0,IEC/UL/EN610102030Ed. 1.0,
IEC/UL/EN610102033Ed.1.0,IEC/UL/EN61010031Ed.1.1andthecorresponding
CAN/CSAC22.2regulationsto MeasurementCategories:
CATIII1000VAC&DCandCategoryIV600VAC&DC
µA & mA:0.4A/1kV DC/ACrms,IR30kA,FFuse; orbetter
A:11A/1kV DC/ACrms, IR20kA,FFuse; orbetter
V:1100V DC/ACrms
mV, &Others:1000V DC/ACrms
8kV(1.2/50 ssurge)
MeetsEN613261:2013
ACVofModel836,inanRFfieldof1V/m:
TotalAccuracy=SpecifiedAccuracy+30 digits
Performance above1V/misnotspecified
All Other Functions,inanRFfieldof3V/m:
TotalAccuracy=SpecifiedAccuracy+150 digits
Performanceabove3V/misnotspecified
Four Alkaline AA batteries(IECLR6)
8mA typicalfor VFDACV +Hz;6.5mA typicalforotherfunctions
approx.4.6V
Idlefor20minutes

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
20 Atypical
L208mmXW103mmXH64.5mmwithholster
635gmwithholster
Testprobepair, Holster,User'smanual, Bkp60bananaplugtypeK
thermocouple(Model839 only)
BKB32bananaplugtotypeKsocketplugadaptor(Model839
only),BMH01magnetichanger;BMP86xsoftcarryingpouch
VFD; Dualdisplay +Hz Readings; Selectable 6,000 &20,000
Counts Resolution; HighUpdate RecordMAX/MINreadings; Crest MAX/MIN readings;
Relative Zero; Display Hold;LCD Backlight; BeepLitTM Continuity Tester, BeepJackTM
audible&visibleinputwarning
Accuracyis (%readingdigits+numberofdigits)orotherwisespecified,at23 C
5 C &lessthan80%relativehumidity.
TrueRMSvoltage¤t accuraciesarespecifiedfrom1%to100 %ofrangeor
otherwisespecified.MaximumCrestFactor<1. 8:1atfullscale&<3. 6:1athalfscale,
andwithfrequencycomponents fall withinthespec ifiedfrequencybandwidthfornon
sinusoidalwaveforms.
Model 839 Model 836
600.0mV 4),6.000V, 60.00V, 600.0V,1000V 0.7% +3d 0.5% +3d
600.0mV 4),6.000V, 60.00V, 600.0V 1 % +3d
1000V 5) 2 % +3d
600.0mV 4),6.000V, 60.00V, 600.0V 1.8% +4d 2) 2% +40d 1)
1000V Unspecified
3)
600.0mV 4) 2.5% +20d 2) Unspecified
6.000V, 60.00V 2% +20d 2) Unspecified
600.0V, 1000V Unspecified
Inputimpedance:10M ,110pFnominal
1)Add 1%@bandwidth>4kHz~5kHz

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
2)Add20d@reading>80%ofrange
3)Unspecified forreadings <5%ofrange
4)Signalpeakabsolutevalues,includingDC bias, lessthan1100mVpeak
5)40Hz~500Hzonlyformodel836
Model839 Model836
199.99mV 3),1.9999V, 19.999V, 199.99V,1000.0V 0.7% +30d 0.5% +30d
199.99mV 3),1.9999V, 19.999V, 199.99V 1 % +30d
1000.0V 4) 2 % +30d
199.99mV 3),1.9999V, 19.999V, 199.99V 1.8% +40d 2% +40d 1)
1000.0V Unspecified
199.99mV 3),1.9999V, 19.999V,199.99V 2% +40d Unspecified
1000.0V Unspecified
Inputimpedance:10M ,110pFnominal
1)Add 1%@bandwidth>4kHz~5kHz
2)Unspecified forreadings <5%ofrange
3)Signalpeakabsolutevalues,includingDC bias, lessthan1100mVpeak
4)40Hz~500Hzonlyformodel836
600.0V,1000V 4%+5d
600.0V,1000V 2.5%+5d
600.0V,1000V 9%+5d 2)
Inputimpedance:10M ,110pFnominal
1)Unspecifiedforfundamentalfrequency>440Hz
2)Accuracylinearlydecreasesfrom2.5%+5d@200Hzto9.0%+5d@440Hz

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
Model839 Model836
600.0mV 0.09% +1d 0.18% +1d
6.000V, 60.00V 0.045% +1d 0.09% +1d
600.0V,1000V 0.09% +1d 0.18% +1d
Inputimpedance:10M , 110pF nominal
Model839 Model836
199.99mV 0.09% +6d 0.18% +6d
1.9999V, 19.999V,199.99V 0.045% +6d 0.09% +6d
1000.0V 0.09% +6d 0.18% +6d
Inputimpedance:10M , 110pF nominal
Model839 Model836
600.0 0.15% +3d 0.3% +3d
6.000k , 60.00k 0.15% +1d 0.3% +1d
600.0k 0.3% +1d 0.6% +1d
6.000M 2) 0.5% +1d 0.7% +1d
60.00M 3) 1.5% +3d 4)6) 2% +3d 4)6)
60.00nS 3) 2.0% +10d 5)6)
1)Open Circuit Voltage:1.7VDCtypical
2)ConstantTest Current:0.2 ATypical
3)ConstantTestCurrent:0.02 ATypical
4)Add1%@>20M
5)Add30d@<20%of range
6)Add2%@operationtemperature>35oC

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
Model839 Model836
199.99 2) 0.15% +20d 0.3% +20d
1.9999k , 19.999k 0.15% +6d 0.3% +6d
199.99k 0.3% +6d 0.6% +6d
1.9999M 3) 0.5% +6d 0.7% +6d
19.999M 4) 1.5% +30d 5) 2% +30d 5)
1)Open Circuit Voltage:1.7VDCtypical
2)Specifiedwithinputleadresistancebeen offset by or (short)feature
3)ConstantTestCurrent:0.2 ATypical
4)ConstantTestCurrent:0.02 ATypical
5)Add2%@operationtemperature>35oC
ContinuityThreshold:Between20 and350
Responsetime:<30ms
AudibleResponse:Beepsound
VisibleResponse:LCDBacklight
2.700V 1.5%+4d 0.4mA <2.8VDC
20.00nF 1% +8d
200.0nF, 2.000 F, 20.00 F, 200.0 F, 2000 F 1% +2d
20.00mF 2% +2d
1)Accuracieswithfilmcapacitororbetter

Eshop: www.emareg.cz Email: [email protected]
www.eMAReg.cz
40.0 C~0.0 C 1% +2.0 C
0.0 C~50.0 C 1%+ 1.0 C
50.0 C ~1090.0 C 1% +1.5 C
40.0 F~32.0 F 1% +3.6 F
32.0 F~122.0 F 1%+ 1.8 F
122.0 F ~1994.0 F 1% +2.7 F
Accuracies assume meter interior has the same temperature of the ambient
(isothermalstage)foracorrectjunctionvoltagecompensation.Allowenoughtimeto
reachtheisothermalstageforasignificantchangeofambienttemperature.Itcantake
uptoanhourforchanges>5°C.
2)TypeKthermocouplerange&accuracynotincluded
Model839 Model836
600.0 A 1) 0.18% +4d 0.36% +4d 0.2mV/ A
6000 A 1) 0.18% +2d 0. 36% +2d 0.2mV/ A
60.00mA 1) 0.18% +4d 0. 36% +4d 3.0mV/mA
600.0mA 1) 2) 0.3% +3d 0. 5% +3d 3.0mV/mA
6.000A 0.5% +4d 0.6% +4d 30mV/A
10.00A 3) 0.7% +2d 0.8% +2d 30mV/A
1) A/mA DCaccuracieswillbeaffectedbyextremeinteriortemperaturesofthemeter.
Forratedaccuracies,allow6to20minutescooldownintervalaftermeasuringA
currentsof3to10Acontinuously.
2) 400mAcontinuous;>400mAfor<1.1hoursonper >20 minutes off
3)10Acontinuous uptoambient35 oC;<15minsonper>5minsoff@35 oC~50 oC.
>10Ato20A for <30seconds onper >5 minsoff
This manual suits for next models
2
Other Brymen Multimeter manuals

Brymen
Brymen BM061s User manual

Brymen
Brymen BM039F User manual

Brymen
Brymen BM867s User manual

Brymen
Brymen BM821s User manual

Brymen
Brymen BM236R User manual

Brymen
Brymen BM837RS User manual

Brymen
Brymen BM857 User manual

Brymen
Brymen TopTronic TBM315 User manual

Brymen
Brymen BM885 User manual

Brymen
Brymen BM22s User manual

Brymen
Brymen BM905s User manual

Brymen
Brymen BM170D Series User manual

Brymen
Brymen BM161 User manual

Brymen
Brymen BM161s User manual

Brymen
Brymen BM195 User manual

Brymen
Brymen BM2807CSE Series User manual

Brymen
Brymen BM195 User manual

Brymen
Brymen BM821 User manual

Brymen
Brymen TBM195 User manual

Brymen
Brymen BM252 User manual