●WARNING! NEVER allow brake fluids, gasoline, petroleum-based products or penetrating oils to come into contact with plastic
parts. They contain chemicals that can damage, weaken, or destroy plastic.
1.8 BATTERY AND CHARGER SAFETY RULES
1) Charge only 14.4V battery pack with your charger supplied in this kit, other types may burst causing damage or personal injury.
2) Do not charge battery when temperature is below 10℃(50℉) or above 40℃(104℉).
3) Do not attempt to use a step-up transformer, an engine generator or DC power receptacle.
4) Do not short the battery pack; a battery short can cause a large current flow, overheating, possible burn, and even a fire.
5) Do not allow anything to cover or clog the charger vents.
6) Do not touch the terminals with any conductive material.
7) Do not store or carry battery pack in a container, bag or pocket with other metal objects, such as nails, coins, paper clips, fingernail clippers,
keys, etc.
8) Do not expose battery pack to water or rain.
9) Do not store the tool in a location where the temperature may exceed 50℃(122℉).
10) Do not incinerate the battery pack even if it is damaged or no longer holds a charge. The battery pack can explode in a fire.
1.9 Rechargeable Battery Power Tool Safety Rules
1. Battery powered tools are generally in an operative condition. Be aware of possible hazards. Before using charger and tool, read all
instructions and markings on tool, charger and battery pack. Before connecting the charger to the battery pack (plugging into receptacle or
outlet), be sure voltage supplied is same as power requirements specified on charger. A voltage source greater than specified can result in
serious injury to the user. When in doubt, do not plug in the charger.
2. Do not charge the battery pack in wet or damp environment or expose to rain or snow.
3. Do not operate charger or tool if damaged in any way. Do not operate charger with damaged cord. Return product to factory. Incorrect
assembly may result in electrical shock or fire. To prevent damage to cord when disconnecting from power source, grip plug body when
removing it from a receptacle. Make sure cord is not subjected to unnecessary abuse.
4. Unplug charger from outlet when attempting maintenance or cleaning.
5. Do not substitute charger of any other device or use an attachment not recommended by manufacturer. Doing so may result in risk of
electrical shock, fire, or risk to persons.
6. If batteries leak, avoid contact with the liquid. Should contact occur, wash immediately with soap and water and seek medical attention.
7. Do not alter or modify tool. Doing so may result in dangerous conditions.
8. Keep charger free of foreign matter.
9. Do not run tool while carrying it. Operate in a stable, stationary position.
10. The use of any other accessories not specified in this manual may create a hazard.
11. Disassembly or tampering with housing of device is not advised and will void warranty.
12. Do not use force when inserting battery pack. To insert fully, make sure both latches on battery pack have snapped into place.
2.0 Contraindications
1) This device should not be used to treat symptomatic local pain unless causes and conditions of the pain are established and a pain
syndrome has been diagnosed by a qualified healthcare professional.
2) This device should not be used when cancerous tumors are present in the treatment area.
3) Percussion massage should not be applied over skin eruptions (e.g. varicose veins, thrombophlebitis, phlebitis, etc.), swollen areas,
inflamed tissue, infections, or injuries such as sprains, broken bones, bruises and burst blood vessels.
4) Do not use this device over the head, face and neck regions. With special training and techniques some minimal application of the device may
be appropriate for these regions. Consult a trained technician or licensed health care provider for guidance.
5) Do not use this device if patient has a cardiac pacemaker or any implanted defibrillator.
6) Patients with sepsis or any type of bacterial toxemia should not use this device.
7) This device should not be used over poorly enervated areas.
8) Do not use this device if patient has blood clotting, serious arterial circulatory problems in the lower limbs, or is currently taking blood thinning
medication.
9) This device should be not be used by people with epilepsy.
10) Patients with abdominal or inguinal hernia should not use this device.
11) Do not use this device if you have heart disease without consulting your physician.
12) Do not use this device if you have kidney disease without consulting your physician.
Warnings, Cautions, and Adverse Reactions
2.1 WARNINGS
1) This device is optimally used under the continued supervision of a licensed physician or certified practitioner.
2) The long-term effects of percussive massager stimulation are unknown.
3) Percussion Power Massager devices do not have any curative value.
4) Percussion massage is a symptomatic treatment, and, as such, suppresses the sensation of pain, which would otherwise serve as a protective
mechanism.
5) Safety has not been established for the use of percussive massage during pregnancy. Do not use during pregnancy unless directed by your
physician.
6) Percussion massage is not effective for pain from central origin, such as headache.
7) Electronic monitoring equipment (such as ECG equipment, and ECG alarms) may not operate correctly when percussion massager
stimulation is in use.
8) Never use the percussion massager in wet conditions such as bath, shower, pool, hot tub, lake, pond, ocean, etc.
9) Caution should be used in applying percussion massager stimulation to patients suffering from heart disease. Further clinical data is needed to
show there are no adverse results.
10) Never use percussion massagers near the heart. Caution should be used when applying the percussion massager pad anywhere on the front
of the thorax (noted by the breastbone and ribs). Take extreme caution when placing on or near the two large pectoral muscles. Here it can
increase the risk of ventrical fibrillation and lead to cardiac arrest.
11) Percussion massager stimulation should never be placed over the ears, nose, eyes, throat, mouth, near the genitals, or internally.
12) Never use percussion massager stimulation on areas of skin that lack normal sensation.
13) Apply percussion massager pad only to clean, unbroken, healthy skin.