manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Burda
  6. •
  7. Timer
  8. •
  9. Burda PERFECTCLIME TS2-C User manual

Burda PERFECTCLIME TS2-C User manual

Popular Timer manuals by other brands

SATO TM-29 instruction manual

SATO

SATO TM-29 instruction manual

Full Gauge Controls ICEMATIC quick start guide

Full Gauge Controls

Full Gauge Controls ICEMATIC quick start guide

CEI Ultrak T-3 instructions

CEI

CEI Ultrak T-3 instructions

Raindrip R675CT Installation & programming

Raindrip

Raindrip R675CT Installation & programming

Intermatic P1131 owner's manual

Intermatic

Intermatic P1131 owner's manual

Profile 010200280 instruction manual

Profile

Profile 010200280 instruction manual

Gizmo T4 instructions

Gizmo

Gizmo T4 instructions

Tekmar Timer 031 Data brochure

Tekmar

Tekmar Timer 031 Data brochure

Daikin DST301B61 Operation manual

Daikin

Daikin DST301B61 Operation manual

sisel ENDA ETM2432 manual

sisel

sisel ENDA ETM2432 manual

B&Q TE103 Installation and use instructions

B&Q

B&Q TE103 Installation and use instructions

Hozelock AC Plus 2700 instructions

Hozelock

Hozelock AC Plus 2700 instructions

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

GIC

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

Emos EMT400F quick start guide

Emos

Emos EMT400F quick start guide

FarmTek Polaris operating instructions

FarmTek

FarmTek Polaris operating instructions

Citizen ME2 series instruction manual

Citizen

Citizen ME2 series instruction manual

Primex OneVue Sync B100 install guide

Primex

Primex OneVue Sync B100 install guide

Rain Bird Optima PRT-4 owner's manual

Rain Bird

Rain Bird Optima PRT-4 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Introduction
The TS2-C is a 2kW timer and part of a family of controllers designed to provide energy
saving when used with Quartz Infrared alogen Lamps or other eating and Lighting
Products. The ‘T’ model switches the lamps on for a pre-determined time period of
between 5 and 60 seconds.
The microcontroller-based unit incorporates zero-voltage switching and a soft-start
function to eliminate the lamps’ initial high inrush current – potentially increasing lamp
life by as much as 30%. Installation of the unit is simple and once installed is relatively
maintenance-free.
Applications:
patio areas, smoking shelters, restaurants, warehouses, workshops and garden
lighting.
Installation
Important: Read carefully the following information before installing the unit.
The TS2-C should be fixed securely using the four mounting holes accessible from the
front of the unit. Remove the lid to access the mounting holes.
IMPORTANT! The unit must be orientated with the cable glands facing down.
iring
It is recommended that installation and maintenance of this equipment should be
done with reference to the current edition of the I.E.E. wiring regulations (BS7671) by
suitably qualified/trained personnel. These regulations contain important
requirements regarding safety of electrical equipment (for International Standards
refer to I.E.C/ directive IEC950).
arning! Isolate the mains supply before commencing any work on this unit. Ensure
all earth wires are connected to maintain earth continuity to the lamp fittings.
The unit is fitted with two cable glands. Only one cable should be fitted per gland to
prevent degrading the unit’s IP rating. When fitting two lamps it is recommended that
a junction box is used.
The mains supply connects to the terminal block marked ‘LINE’. Connect the supply
LIVE to the ‘L’ terminal, NEUTRAL to the ‘N’ terminal and EARTH to the ‘E’ terminal.
The lamps connect to the terminal block marked ‘LOAD’. Connect the load LIVE to the
‘L’ terminal, NEUTRAL to the ‘N’ terminal and EARTH to the ‘E’ terminal. If two lamps
are to be fitted they must be wired in parallel.Check all wiring and make sure the cable
glands are tightened.
Mounting Template
Technical Specification
Supply Voltage 230VAC +/- 10%
Supply Frequency 50 z
Switching Capacity 2kW Max.
Lamp On-Time 5 to 60 seconds
Current Consumption (control circuit) 50mA
Terminals 2.5mm
2
Rising Clamp
Operating Temperature -20 to 40°C
Protection Rating IP55
Gland Diameter Max Cable Entry 2.5mm²
Fixings 4 x 3.5Ø holes 97 x 82mm centres
Not for general waste
IMPORTANT!
Drilling of any holes through the enclosure
will immediately invalidate the warranty of
the unit. The unit MUST be orientated with
the cable glands facing down.
TS2-C
INSTRUCTIONS FOR USE
Subject to errors and technical changes
Burda Worldwide Technologies GmbH – Rudolf-Diesel Straße 18 – D-65760 Eschborn
T: +49 6173 324240 - F:+49 6173 3242424 - [email protected] – www.burdawtg.com
Commissioning
Set the on-time preset to a time period of between 5 and 60 seconds. The cermet is
located at the top of the printed circuit board as shown below. Replace the lid and
switch on the mains supply to the unit. Press the push-button on the front of the unit
to switch the lamps on.
iring Diagram