LASER METER 50 PS 7550
www.burg-waechter.de
LASER METER 50
BURG-WÄCHTER KG
Altenhofer Weg 15
58300 Wetter
Germany
ProfiScale LASER METER 50
Laser Distance Meter
en Operating instructions
BA LaserMeter dp 05/2012
0,5–50m
m2/m3
ft2/ft3
precision
+0,002 m
indirect
measurement
ProfiScale LASER METER 50 PS 7550 2
English |2
On and measurement button
Distance measurement button
Button for surface area and
volume measurement
Button for indirect measurement
EButton for continuous
measuremen
FOff button
GCalling of memoryAnzeige
HDelete button for the last reading
ILighting and unit selection
button
JSubtract button
KAdd button
LReference plane
MEnd stop
1Laser active
2– 4Measurement basis
5Variable measurement functions
Surface area measurement
Volume measurement
Indirect length measurement
6Individual length measurement
7Battery status indicator
8Reading memory
9Failure symbol
10 First reading
11 Second reading
12 Resulting reading of first
measurement
or calculated result
13 Computing operations
+ Add symbol
- Subtract symbol
Introduction
The LASER METER 50 PS 7550 laser distance measurement device is intended
for precision measurement of distances and clearances and for calculation
of surface areas and volumes. In addition, also inaccessible lengths can be
measured by means of indirect distance measurement. Thanks to these and
other functions, it is an ideal measurement device for interior designers,
building companies, real estate agents, craftsmen, etc.
Structure
F G H
A
C
D
E
B
K
J
I
L
1
24
5
13
68
7
10
11
12
9
M
EXTRA
2x
ProfiScale LASER METER 50 PS 7550 3
English |3
Safety instructions
Injuries can occur if the following instructions are not observed:
1. Please read these Operating Instructions attentively before using the device.
Keep the Instructions for future use.
2. The warning labels on the device shall never be made unrecognizable or
removed from the device.
The device is shipped with warning notices in the German language. Please
paste the attached warning labels in your language over the original ones before
the initial commissioning.
3. Never point the laser beam at the eyes of other persons or animals.
Do not look into the laser beam and do not handle the laser light using
optical equipment. This can damage the eyes.
4. Never let children use the laser meter without surveillance. They can
inadvertently injure themselves or other persons.
5. Do not use the device in flammable or explosive environment. Sparks can
be generated in the device, which may cause fire in the environment.
6. Have the measurement device repaired by qualified professionals only and
using original replacement parts. In such a way, the safety of the device can
be preserved.
Attention: The measurement device may loose its precision by a strong impact
and when falling. Whenever in doubt, perform an accuracy check using a
well known measured distance for the sake of certainty. The measurement
device shall be protected from humidity and strong effects of heat caused e.g.
by direct sunshine. Please provide enough time for the device to adjust to the
ambient temperature.
Warranty
Congratulations
that you have decided for the ProfiScale quality measurement technology
by BURG-WÄCHTER. BURG-WÄCHTER provides a warranty of 2 years from
the date of purchase. Excluded from this warranty are damages caused
by inappropriate use, overstrain or improper storage, as well as normal
wear and tear and deficiencies with an insignificant influence on the value
and function of the device. The warranty becomes void in case of any un-
authorized intervention. In the event of a warranty claim, please provide the
complete device incl. its packaging, description and batteries, as well as your
purchase document, to your dealer.Garantie
Technical data
Effective measurement
range
0,05 to 50 m
0,16 to 164 ft
Accuracy ± 0,002 m*
Resolution 0,001 m
Units of measure m, in, ft
Laser type λ=635 nm; Pmax<1 mW
Laser class class II
Type of protection IP 54
Power supply 2 x AAA Micro LR03 batteries
Automatic
shutoff
The laser switches off automatically after
30 seconds.
The device powers off automatically after
3 minutes.
Operating temperature 0°C to 40°C
Storage temperature -10°C to 60° C
Dimensions 115mmx 60 mmx29 mm
Weight approx. 150g
(without batteries)
*The operating range and the accuracy depend on the ambient conditions.
In case of adverse conditions, such as strong sunshine and/or poorly
reflecting measured surfaces, the readings may differ from the values
indicated in the table.
Operation
Insert/replace the batteries
Open the battery compartment cover at the back of the device by first
loosening the safety screw and then pulling the battery compartment cover
up. Then insert the batteries as indicated in the battery compartment. Then
replace and fix the battery compartment cover.
Attention: Remove the batteries when not using the device for a longer
period of time.
Switch the device on
Press the button “A” and, before measurement, check the activated
reference plane.
Reference plane
Three different reference planes can be selected in the measurement device:
• Thedevicerearedge,tobeappliedforexampleonawall
• Thedevicefrontedge,tomeasureforexamplefromasharpedge
• Themovableendstop“M”,inordertomeasurefromcornersorpoorly
accessible places
To change the reference plane, press the button “L”. The active plane is
indicated in the display under “2–4“. Whenever the measurement device is
switched on, the reference plane is set to the device rear edge.
LASER RAdiAtion
Never look into the beam
Laser class 2
EN 60825-1: 2007
Pmax<1 mW; λ=635 nm
ProfiScale LASER METER 50 PS 7550 4
English |4
Measurement functions
Length measurement
Length measurement is preset when the device is switched on. The display
indicates the length measurement symbol. Aim at the end of the measured
distance and press the button “A” again. The reading is indicated below in
the “12” display.
Surface area measurement
Press the button “C” once in order to select surface area measurement. The
display indicates the symbol for surface area measurement, the first surface
length flashes. Aim at the desired target and press the button “A” once to
take the measurement. The reading is indicated above in the “10” display,
while the second surface length flashes. Use the laser to aim at the next target
and press the button “A” to take the measurement. The reading is indicated
in the “11” display, while the resulting surface area has been calculated and
indicated in “12”.
Volume measurement
Press the button “C” twice in order to select volume measurement. The
display indicates the symbol for volume measurement, the first volume length
flashes. Aim at the desired target and press the button “A” to take the first
measurement. The reading is indicated above in the “10”display, while the
second volume length flashes. Use the laser to aim at the next target and press
the button “A” to take the measurement. Proceed in a similar way for the third
length. The reading is indicated in the “11” display, while the resulting volume
has been calculated and indicated in “12”. Indirect length measurement Using
this function you can measure directly inaccessible distances (e.g. exterior wall
heights), as two or three measurable lengths are mutually related based on
trigonometric functions.
Measurement based on two lengths
Press the button “D” once in order to select indirect length measurement.
The display indicates the indirect measurement symbol, the first length flashes.
Aim at the desired target and press the button “A” once to take the first
measurement. The reading is indicated above in the “10” display, while the
second length in the display flashes. Use the laser to aim at the next target and
press the button “A” to take the measurement. The reading is indicated in the
display, while the resulting length has been calculated and indicated in “12”.
Measurement based on three lengths
Press the button “D” twice in order to select indirect length measurement based
on three lengths. The display indicates the indirect measurement symbol, the
first length flashes. Aim at the desired target and press the button “A” once to
take the first measurement. The reading is indicated above in the “10” display,
while the second length in the display flashes. Use the laser to aim at the next
target and press the button “A” to take the measurement. The reading is
indicated in the display. Proceed in a similar way for the third length. The reading
is indicated in the display, while the resulting length has been calculated and
indicated in “12”.
Continuous measurement
The continuous measurement function is intended for deriving dimensions
for instance from construction plans. The minimum and maximum
values can also be determined in this way. When this function is used,
the measurement device moves relative to the target, while the reading is
updated approx. every 0.5 sec. During this, the minimum distance is indicated
in the “10” display and the maximum distance in the “11” display. The
currently measured value is always indicated in the “12” display. Press the
button “5“ for approx. 3 sec until you receive an indication and move the
measurement device. The distances are indicated in the display. To deactivate
the function, press the button “A”. The function switches off automatically
after 100 measurements.
Computing operations
Addition
This is intended to add two or more lengths. When you have measured
the first length, press the add symbol “K”. The reading is indicated above
in the “10” display, while the “+” symbol in the display flashes. Press the
button “A” again, and the total is indicated in the bottom line. You can
add more values in this way.
Subtraction
When you have measured the first length, press the subtract symbol “J”.
The reading is indicated above in the “10” display, while the “–“ symbol in
the display flashes. Press the button “A” again, and the total is indicated in
the bottom line. In this way, you can subtract more values from each other.
Memory function
The memory function contains the 10 last readings. For this purpose, press
the button “G”. The memory values can be scrolled using the Add and
Subtract buttons (buttons “J” and “K”) and thus shown in the display.
Individual readings can be deleted from the list using the Delete button “H”.
Lighting and unit selection button
The display lighting can be switched on and off by pressing the lighting or
unit selection button briefly. When the button is pressed for a longer time,
the unit of measure of the readings changes (m, ft, in, ft+in).
Causes and removal of errors
The device will help you in case of measurement troubles, as various codes
are indicated in the display.
Error Codes Correction
204 Calculation error Repeat the process
208 Received signal is too weak,
measurement takes too long
Measured distance > 50m.
Measurement with
a target plate
209 Received signal is too strong. Measurement with a target plate
252 Temperature is too high Cool the device down
253 Temperature is too low Warm up the device
255 Device failure Switch the device on and off
several times. In case the error
message persists, please contact
your dealer.
Disposal of the device
Dear customer,
please help us to reduce waste. Should you ever intend to dispose of
this device, please bear in mind that many components of the device
contain precious materials, which can be recycled. Please do not dispose
of this device as common waste, but rather request information from the
responsible local authority on the collecting points for electric waste.
The dustbin symbol indicates:
Discharged batteries or accumulators must not be disposed as
common waste. Please return the batteries/accumulators to
their vendor or the local recycling yard. Their return is free of
charge and it is legally required.
Errors and changes reserved.

Popular Analytical Instrument manuals by other brands

Elditest GE1500 Series manual

Elditest

Elditest GE1500 Series manual

Wohler VIS 700 manual

Wohler

Wohler VIS 700 manual

CONDTROL XP3 user manual

CONDTROL

CONDTROL XP3 user manual

burkle ViscoSampler Directions for use

burkle

burkle ViscoSampler Directions for use

Fluke ESA601 Operators Operator's manual

Fluke

Fluke ESA601 Operators Operator's manual

Wohler VIS Camera Viper 36 Operation manual

Wohler

Wohler VIS Camera Viper 36 Operation manual

Whistler WIC4750 owner's manual

Whistler

Whistler WIC4750 owner's manual

Novascope PTC606000 manual

Novascope

Novascope PTC606000 manual

Emerson RIDGID SeeSnake CSx Via 66528 Operator's manual

Emerson

Emerson RIDGID SeeSnake CSx Via 66528 Operator's manual

Uemsi U-VUE Operation and maintenance manual

Uemsi

Uemsi U-VUE Operation and maintenance manual

Eschenbach Mobilux Digital Inspection operating instructions

Eschenbach

Eschenbach Mobilux Digital Inspection operating instructions

Bühler technologies GAS 222.31 Ex1 Installation and operation instruction

Bühler technologies

Bühler technologies GAS 222.31 Ex1 Installation and operation instruction

SICK MCS300P technical information

SICK

SICK MCS300P technical information

Vivax Metrotech vLoc3 RTK-Pro Quick setup guide

Vivax Metrotech

Vivax Metrotech vLoc3 RTK-Pro Quick setup guide

Depstech DS350 user manual

Depstech

Depstech DS350 user manual

Netzerotools HDV600 user guide

Netzerotools

Netzerotools HDV600 user guide

Atel Electronics ES049A user manual

Atel Electronics

Atel Electronics ES049A user manual

CLAS AC 5039 manual

CLAS

CLAS AC 5039 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.