3. Set aside the enclosure and drill a hole at the cable entry location.
4. Mount two screws in the wall, or into wall anchors, leaving at least 1/8” from the wall to the
underside of the screw head.
5. Test fit the enclosure back half against the wall. Check for a secure fit, still allowing for removal of
the TEMP-WALLMOUNT from the wall.
6. From the location of the ARC Solo RJ splitter, route the TEMP-WALLMOUNT cable through the wall
and the rear of the enclosure. The length of the cable does not affect calibration, and it may be
extended as required.
7. Attach the cable to the terminal block on the front half of the TEMP-WALLMOUNT.
8. Secure the two halves of the TEMP-WALLMOUNT using the 3/4” screws, being careful not to over
tighten them.
9. Place the TEMP-WALLMOUNT against the wall and secure it to the mounting screws.
10. Plug the connector of the TEMP-WALLMOUNT into one of the four available input jacks on the ARC
Solo RJ splitter.
TEMP–STACK Sensor
1. Select a location on the equipment ducting that is flat and able to support the weight of the TEMP-
STACK and its mounting hardware. Make certain there are no obstructions on the inside of the
ducting or cavity.
2. Using the mounting base as a template, mark the location of all mounting holes.
3. Drill or cut a hole approximately 3/4” in diameter for the TEMP-STACK probe.
4. Thread the 3/8” brass pipe fitting onto the base, and secure the base to the surface using the
supplied sheet metal screws.
5. Insert the TEMP-STACK into the brass mount and secure it with the locking nut. Be certain to not
tighten excessively, as this may deform the compression sleeve. Check for a secure fit, still allowing
for adjustment of the probe depth.
6. Plug the connector of the TEMP-STACK into one of the four available input jacks on the ARC Solo
splitter.
Remote Control Setup
ARC Solo
•To enter your license key, go to the ARC Solo web page and select System/Basic Settings. Enter
your license key in the Sensors Authorization box.
•To select between Fahrenheit or Celsius, go to the ARC Solo web page and select System/Basic
Settings in firmware version 1.0.57 or System/Sensors in firmware version 1.0.58 or higher.
•To map the sensor to a meter channel, go to the ARC Solo web page and select system/sensors.
Use the provided drop-down boxes to assign each active temperature sensor to an ARC Solo
meter channel.
No calibration is necessary. Please refer to your ARC Solo manual for detailed instructions on meter
setup.