Type 2509
Cable plug
Conduit Connection, UR approved
Operating Instructions
SYMBOLS
→designates a procedure which you must carry out.
Warning of serious or fatal injuries:
Danger!
In case of imminent danger.
Warning!
In case of potential danger.
Address
Germany / Deutschland / Allemagne
Bürkert Fluid Control Systems
Sales Center
Christian-Bürkert-Str. 13-17
D-74653 Ingelngen
Tel. + 49 (0) 7940 - 10-91 111
Fax + 49 (0) 7940 - 10-91 448
E-mail: [email protected]
International: www.burkert.com
Manuals and data sheets on the Internet : www.burkert.com
© Bürkert Werke GmbH & Co. KG, 2018
Operating Instructions 1803/00_EN-EN_00810635 / Original DE
1 SYSTEM
DESCRIPTION
1.1 General description
The cable plug Type 2509 with UL certication consists
of a polyamide housing without integrated electronics.
The connector is in accordance with DIN EN 175301-803
(previously DIN 43650 Form A).
1.2 Functions
The cable plug Type 2509 is used for joining conduit con-
nections to solenoid coils.
2 TECHNICAL DATA
2.1 Conformity
The cable plug Type 2509 conforms to the EU directives
according to the EU Declaration of Conformity (where
applicable).
2.2 Standards
The applied standards, which are used to demonstrate
conformity with the EU Directives, are listed in the EU type
test certicate and/or the EU Declaration of Conformity
(where applicable).
2.3 Operating conditions
Certication UR le no. E238288
Self-Declared Operating Conditions
Operating temperature –40 °C...+90 °C
(–40 °F...+194 °F)
Degree of protection NEMA 4X (IP65)
2.4 Mechanical data
Dimensions see data sheet
(approx. 33 x 33 x 59 mm)
Materials
Housing Polyamide
Seal NBR
Contacts Copper alloy, silvered
Cable outlet Contact insert can be rotated
by
4 x 90° after removal
Poles 2-pole + protective conductor /
3-pole + protective conductor
Electrical connection 3 or 4 terminals in the contact
insert Wire diameter AWG18
Thread of the
conduit screw
connection 1/2 “ NPT
Approved conduit connections
•for use with exible conduit only
2.5 Electrical data
Power supply 0 ... 250 V AC/DC
Max. electrical current 6 A
2.6 Pin assignment
Details of the pin assignment can be found in the data
sheet for the corresponding valve.
english
3 ASSEMBLY
3.1 Safety instructions
Warning!
Risk of injury from improper assembly.
▶Assembly may only be carried out by authorized
technicians and with the appropriate tools.
Risk of injury from unintentional activation of the
system and uncontrolled restart.
▶Secure system against unintentional activation.
▶Following assembly, ensure a controlled restart.
3.2 Electrical connection
Danger!
Risk of electric shock.
▶Before reaching into the device, switch o the power
supply and secure to prevent reactivation.
▶Observe applicable accident prevention and safety
regulations for electrical equipment.
7 mm max.
approx. 100 mm
Figure 1: Remove cable insulation
→Remove cable insulation to a length of approx. 100
mm (see „Figure 1“).
→Remove contact insert from housing (see „Figure 2“).
→Feed wire conductors under the strain relief through
the housing.
→Remove the insulation from the wire conductors to a
max. length of 7 mm (1/4 “) (see „Figure 1“).
→Connect the cable plug in accordance with the pin
assignment of the valve. Tighten the screws on the
terminals to
max. 0.5 Nm (4.4 in-lb).
→Re-t the contact insert into the housing.
→Lay the wire conductors beside one another under
the strain relief. Tighten the screws on the strain relief
to max. 0.5 Nm (4.4 in-lb).
→Fit the cover and screw onto the housing.
Seal
Contact insert
Housing
Strain relief
Screw
Clamping piece
Cover
Figure 2: Exploded view of cable plug Type 2509
3.3 Installing the cable plug
Warning!
Risk of short circuit if the screw connection is not
sealed.
▶Ensure that the seal is tted correctly.
▶Carefully attach the cable plug.
The cable outlet can be rotated by 4 x 90°.
max. 1 Nm
Seal
max. 6.75 Nm
Figure 3: Installing the cable plug
→Fit the conduit connection and tighten the screw con-
nection. Observe tightening torque of max. 6.75 Nm
(60 in-lb).
→Use screw to attach the cable plug to the coil.
Observe tightening torque of max. 1.0 Nm (8.8 in-lb).

Other manuals for 2509

3

Other Burkert Cables And Connectors manuals

Burkert BBS-04 User manual

Burkert

Burkert BBS-04 User manual

Burkert 2509 User manual

Burkert

Burkert 2509 User manual

Burkert 2509 User manual

Burkert

Burkert 2509 User manual

Burkert 2510 User manual

Burkert

Burkert 2510 User manual

Popular Cables And Connectors manuals by other brands

ATEN UN-201 user manual

ATEN

ATEN UN-201 user manual

Marmitek Split TS14 user manual

Marmitek

Marmitek Split TS14 user manual

Manhattan 207454 instructions

Manhattan

Manhattan 207454 instructions

Siemens 3WN6 manual

Siemens

Siemens 3WN6 manual

Viessmann 9565 0 Operation manual

Viessmann

Viessmann 9565 0 Operation manual

Scame 899.AS5AR312 Assembly instructions

Scame

Scame 899.AS5AR312 Assembly instructions

Festo NEBM-M12G8-E S1G9-V4 Series Assembly instructions

Festo

Festo NEBM-M12G8-E S1G9-V4 Series Assembly instructions

Lenze L-force EYF A Series Mounting instructions

Lenze

Lenze L-force EYF A Series Mounting instructions

TE Connectivity EP-II instruction sheet

TE Connectivity

TE Connectivity EP-II instruction sheet

TE Connectivity Miniature AMP-IN Application Specification

TE Connectivity

TE Connectivity Miniature AMP-IN Application Specification

Echogear EGAV-CMIWSB owner's guide

Echogear

Echogear EGAV-CMIWSB owner's guide

Staubli PV-KST4 UR Series Assembly instructions

Staubli

Staubli PV-KST4 UR Series Assembly instructions

Philips MWS2823T Specifications

Philips

Philips MWS2823T Specifications

Philips Coil Cord US2-P70051 Specification sheet

Philips

Philips Coil Cord US2-P70051 Specification sheet

Bogen CK10 installation guide

Bogen

Bogen CK10 installation guide

Paradyne HotWire 5034 installation instructions

Paradyne

Paradyne HotWire 5034 installation instructions

Thermon Terminator DL Installation procedures

Thermon

Thermon Terminator DL Installation procedures

Festo NEBC-M8G4-ES-S1G9-RS2 Series Instructions & assembly

Festo

Festo NEBC-M8G4-ES-S1G9-RS2 Series Instructions & assembly

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.