General safety information and warning
WARNING
2
Electrical service supply must be 120V 60Hz.
Follow all local building,safety and electrical codes as well as NEC(National Electrical Code) and OSHA
(Occupational Safety and Health Act).
This unit must be properly grounded.
Always disconnect the power supply prior to servicing the fan, motor or junction box.
Do not bend or kink the power wires.
Do not install where the room air temperature will exceed 104ºF (40ºC).
This ventilation fan is approved for use in a ceiling over a bathtub or shower when installed o n a ground-fault
circuit interrupter (GFCI) protected circuit. Do not use fan over a bathtub or shower that is not approved for
that application and marked accordingly.
Do not use to exhaust hazardous or explosive vapors.
Do not install in a cooking area.
Use this unit in the manner intended by the manufacturer. If you have any questions,please call customer service.
Installation work must be carried out by a qualifed person, in accordance to all local and safety codes, including
the rules for re-rated constructions.
Exercise care not to damage existing wiring when cutting or drilling into walls or ceilings.
Fans should always be vented to the exterior and in compliance with local codes. Do not vent exhaust air in
spaces within walls, ceiling, attic, crawl space or garage.
Do not use this fan with any solid state control device.
Prior to service or cleaning this unit, shut off power supply at the panel and lock to prevent the power from
being turned on.
Duct work should be installed in a straight line with minimal bends.
Duct work size must be a minimum of the discharge and should not be reduced. Reducing the duct size can
increase fan noise.
The switch should not be accessible from inside of bathtub or shower.
The fan is to be mounted at least 7 feet (2.1 m) above the foor.
If this unit is to be installed over a tub or shower, it must be marked as a appropriate for the
application. When the fan is going to install in the bathroom, the fan and the tub need to be more than 1.0 meter
between each other, the fan required to install at the other side of the tub in ceiling. Acceptable for use over a
bathtub or shower when installed in a GFCI protected branch circuit.
The housing of ventilation fan NO: B-1
The wheel assembly of ventilation fan: B
Combine B-1 and B first,and then mounted to the ceiling.