BYD N95 Operator's manual

Description
The Particulate Respirator DE2322 is designed to help provide respiratory protection for the user. This product has a filter efficiency of 95% or
greater against solid and liquid aerosols free of oil.
This product contains no components made from natural rubber latex.
Foldable
Very close facial fit
≥95% filtrations efficiency against solid
and liquid aerosols free of oil.
Non-sterile
Use instructions
Suitable for protecting the mouth, nose, and chin to airborne particles and block
liquid aerosols.
For adults use only.
Do not wash.
Store in a cool, dry, clean place away from fire and contamination.
Store between -20℃ and 38℃ (-4°F and 100°F) with relative humidity below 80%.
Expiration date: 2 years after production.
Wearing instructions
Fit check
1. Place both hands over mask.
2. Take a deep breath and hold your breath for a few seconds, making sure the mask collapses inward as you inhale.
3. Then exhale and hold your breath for a few seconds, making sure the mask bulges outward as you exhale.
4. If air leaks, reposition the mask, tighten the metallic strip and reposition the elastic bands for a better fit.
Follow steps 1-3 again until a tight seal has been achieved.
5. Masks that have passed the fit check are now safe to use.
6. Facial hair or other facial features may prevent the mask from achieving a proper fit. If a tight seal is not achievable,
please DO NOT use this product.
7. If you experience difficulty breathing, dizziness, or other symptoms, leave the contaminated area immediately.
Unfold the mask and hold it with both hands, with the metallic strip facing up.
Place elastic bands around the neck and head respectively. Put the mask
against your face covering both nose and mouth.
Adjust the metallic strip cover bridge of the nose using two fingers to press
down until achieving a close fit.
Perform a fit check according to instructions.
Picture is for reference only,
actual product may have differences.
3-Step check before use
1. Do not use if packaging has been opened
or damaged.
2. Check if elastic bands are in good condition
and are not damaged.
3. Check that the metallic strip is not broken.
N95
Particulate Respirator

Foldable Non-sterile
Name
Product name
Materials
Product model
Packaging specification
Parameter
N95 Particulate Respirator
Inner layer: polypropylene spunbond nonwoven fabric;
Middle layer: polypropylene melt-blown nonwoven + hot air cotton;
Outer layer: polypropylene spunbond nonwoven fabric ;
Elastic bands: polyester/nylon spandex blend;
Nose clip: aluminum
DE2322 (Foldable)
1pc/bag; 20pcs/box; 960pcs/case
Specifications
Outer layer
Polypropylene
spunbond nonwoven fabric
Middle layer 1
Polypropylene
melt-blown nonwoven Middle layer 2
Hot air cotton
Nose clip
Aluminum
Elastic bands
Polyester/nylon spandex blend
Inner layer
Polypropylene
spunbond nonwoven
fabric Polypropylene melt-blown nonwoven
Polypropylene spunbond
nonwoven fabric
Polypropylene spunbond nonwoven fabric
Hot air cotton
If the mask becomes damaged, soiled, or breathing becomes difficult, leave the contaminated area and replace and refit the new mask.
Time use limitation
Important notice
The following materials are used in the production of N95 Particulate Respirator.
1. To the extent permitted by law, BYD shall not be liable for any loss or damage including any loss of business, loss of profits, or for any
indirect, special, incidental or consequential loss or damage arising from reliance upon any information herein provided by BYD. Nothing
in this statement will be deemed exclude or restrict BYD's liability for death or personal injury arising from its negligence.
2. Staples are used for strap fastening, it is normal that small punctures be found around the staples. Product sampling has been processed
to ensure the respirators meet Part 84 approval requirement.
3. The process of the strap fastening has been strictly controlled. Any enlarged holes resulting from ripped filter material around staple
punctures are considered as damage.
4. Filtering facepieces are to be inspected prior to each use to assure there are no holes in the breathing zone other than punctures around
staples and no damage has occurred.
5. Before occupational use of this respirator, a written respiratory protection program must be implemented meeting all the local
government requirements. In the United States, employers must comply with OSHA 29 CFR 1910.134 which includes medical evaluation,
training, and fit testing.
N95
Particulate Respirator
1. The mask does not eliminate the risk of contracting any disease or infection.
2. Improper use may lead to illness and even death.
3. Use this product immediately after package is opened.
4. Not recommended for more than 8 hours of use.
5. DO NOT sleep while wearing the mask.
6. Avoid hand contact within the interior part of the mask.
7. DO NOT use masks if they expired.
8. For one-time use only. Dispose the mask according to regulations.
9. DO NOT use if package is damaged.
WARNINGS

Foldable Non-sterile
Scan and visit
BYD Care website
Scan and download
BYD Care app
Distributed by
Global Healthcare Product Solutions, LLC
1800 S. Figueroa Street, Los Angeles, CA 90015
1(800)293-2886
www.byd.care
Made in China
Approval and Standard
N95
Particulate Respirator
1. Protection
2. Cautions and Limitations
A- Not for use in atmospheres containing less than 19.5% oxygen.
B- Not for use in atmospheres immediately dangerous to life or health.
C -Do not exceed maximum use concentrations established by regulatory standards.
J -Failure to properly use and maintain this product could result in injury or death.
M-All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations.
N-Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer.
O- Refer to User Instructions and/or maintenance manuals for information on use and maintenance of these respirators.
P- NIOSH does not evaluates respirators for use as surgical masks.
This respirator is approved only in the following configuration:
BYD Precision Manufacture Co.,Ltd.
No.3001 Baohe Road, Baolong Industrial City,
LongGang Street, LongGang District, Shenzhen, Guangdong Province, China
+86-755-8988 8888
TC-
84A-9221
Protection1
N95
Respirator
DE2322
X
Cautions and Limitations2
ABCJMNOP
N95 ‒ Particulate Filter (95% filter efficiency level).
Effective against particulate aerosols free of oil; time use restrictions may apply.
GB 19083-2010 standard
This manual suits for next models
1
Table of contents
Other BYD Respiratory Product manuals