Ultrasonic Rodent Repellent System Control Panel:
Features:
1. 2 x 16 alpha numeric LCD with back light
2. Power ON LED indication.
3. 4 keys for menu navigation.
4. Power amplifier output for connecting ultrasonic
transducers.
5. Audible tone for transducer testing
6. User selectable wave sweep time, & wave sweep delay
setting. Default sweep time is 1 ms (1 to 10ms). Default
Sweep delay 2 sec (1 to 10 sec).
7. A volt free contact is provided in the panel to monitor the
power on healthy status of the panel.
Menu Setup
1. Menu navigation can be achieved using Up, Down, Enter & Exit
2. To enter to the menu, Press Enter.
3. All the parameters are factory programmed and no manual
settings are required.
4. To test the operation of transducer, press “Enter” from
main screen & press up /down key till you see “TEST
Transducers”.
5. Press Enter key. An audible sound will be heard from all
transducers. This ensures that all the transducers are
working normally.
6. To change the site name, navigate the menu to select
“SITE NAME” by pressing UP/DOWN key.
7. Press Enter to edit the Site Name. Press Enter to save
& Exit.
Modbus Integration
All the parameters sent in the panel can be monitored through
MODBUS RTU protocol via any standard BMS. Refer Modubus
document for details.