CAMDEN CV-550SPK V3 User manual

Page 1 of 7
CV-550SPK V3
Waterproof Keypad/Reader/Controller
INSTALLATION INSTRUCTIONS
Door Activation Devices
(1) Keypad CV-550SPK V3
(1) User Manual
(1) Screw driver
(4) Wall plugs
(6 x 27 mm, used for mounting)
(4) Self tapping screws
(3.5 x 27 mm, used for mounting)
(2) 6-32x1” Pan head machine
screws to mount to single gang
switch box.
THIS PACKAGE INCLUDES:
3. DIMENSIONS
1. DESCRIPTION
The CV-550SPK V3 is a back-lit single door multifunction standalone
access control keypad with a Wiegand input/output interface.
It is suitable for mounting either indoors or outdoors in harsh
environments. It is housed in a strong, sturdy and vandal proof Zinc
Alloy electroplated case. The supplied shield will provide greater
visibility of the illuminated status LED'S as well as keeping weather
elements off of the face of the keypad. The electronics are fully potted
so the CV-550SPK V3 is waterproof and conforms to IP68.
The CV-550SPK V3 supports up to 20,000 users in either a Card, 4-to-
6-digit PIN, or a Card + PIN option. The built-in card reader supports
125KHZ HID 26/34/37-bit cards/tags, as well as the EM format. The
PIN output data can be congured for either 26 bit, 4-bit or 8-bit burst
modes making it compatible with most Access systems.
These features make the CV-550SPK V3 an ideal choice for door
access for commercial and industrial applications such as factories,
oces, warehouses, laboratories, banks, and prisons.
2. SPECIFICATIONS
Input Power 10 - 28V AC/DC
Standby Current 35mA (Input VDC12V)
Operating Current: 100mA (Input VDC12V)
Working Humidity 0-95%
Working
Temperature -40°C - 60°C (-40F – 140F)
Alarm Output
(Digital) 1A @ 30VDC
Lock Relay 1A @ 30VDC
Read Range 5 cm
Users 20,000
Reader Format HID/ EM
Reader Bit Pattern 8 Bit Burst, 26, 34 or 37 bit
Keypad Format 26 bit standard, 4 bit or 8 bit burst
IP Rating 68
Note: When the keypad is idle the LED is solid RED. In
programming mode, the LED is ashing RED. The Master code
for programming must be changed to congure any part of the
CV-550SPK and its parameters. All changes must be done within
programming mode.
5"
[127mm]
3 1/4"
[82mm] 1 1/8"
[29mm]
Surface Mounting
Hole
5 7/8"
[150mm]
31
2"
[90mm]
4 1/8"
[104mm]
3 1/4"
[83mm]
2 3/8"
[61mm]
Ø1/2"
[13mm]
Wire Harness
Access
Single Gang
Mounting Hole
Single Gang
Mounting Hole
Surface Mounting
Hole
Surface Mounting
Hole
Surface
Mounting
Hole
Surface Mounting
Hole
5 7/8"
[150mm]
31
2"
[90mm]
4 1/8"
[104mm]
3 1/4"
[83mm]
2 3/8"
[61mm]
Ø1/2"
[13mm]
Wire Harness
Access
Single Gang
Mounting Hole
Single Gang
Mounting Hole
Surface Mounting
Hole
Surface Mounting
Hole
Surface
Mounting
Hole
2 3/8"
[61mm]
Ø1/8"
[4mm]
6 Places
Ø5/8"
[16mm]
3 1/4"
[83mm]

Page 2 of 7
CV-550SPK V3 WATERPROOF KEYPAD
INSTALLATION INSTRUCTIONS
Enter Programming Mode
Press the star (*) key for 2 seconds until it beeps then press
8 8 8 8 8 8 #.
The LED will now be ashing Red.
Exit Programming Mode Press the star key (*) to get a solid Red LED.
Change Admin Password
00 New 6-digit code #, New 6-digit code # (must be 6 digits).
The keypad cannot be congured until the Master Code has
been changed from its default to any other 6-digit PIN.
Default Master Code
Power up while holding the * key. The LED will turn orange
and you will hear a double beep.
This will only default the Master Code for programming. All
other data will not be affected.
Restore Conguration to Factory Defaults For assistance call the Camden Technical Support line at
1-905-366-3377.
Delete All Users Card/PIN Data Press 20 0000 #Deletes All User Card/PIN data.
Stand-Alone Operation (All Card/PIN Data stored in the CV-550SPK V3)
Single Door Stand-Alone 03 1 # Stand-Alone Mode
ID#
This refers to the memory address of where the Card or PIN
data is stored. It is not the PIN to unlock the door.
Keep track of where data is stored to easily edit or delete any
individual record.
Add a Card (Automatically Generates ID#)
10 Read Card #
Multiple Entries 10 Read Card, Read Card, Read Card, Read
Card #. This will increment the ID# (storage location) by one
for each card added.
Add a Card or PIN
(To a Specic ID#)
11 ID# (4-Digit PIN or Card) #
Multiple Entries 11(ID) #, (User PIN or Card) #, (ID) #, (User
PIN or Card) #
This will allow you to pick a unique ID # (storage location) to
add the card or PIN to.
Delete Card (by Reading) 21 Read Card Multiple Deletes 21 Read, Read, Read, #
Delete by ID# (Card or PIN) 22 ID# # Multiple Deletes 22 ID# #, ID# #, ID# #
Door Access Mode
30 0 # (Card Only) Users must only use a Card or Tag.
30 1 # (Card + PIN) Users must read their Card or Tag then
type in their PIN then #.
Note: Press * for 2 seconds (beep), read card press 1234#,
New PIN then #, New PIN then #.
30 2 # (Card or PIN) Users can use either their Card, Tag or
PIN number.
Unlock Duration 34 (1-999 seconds) #

Page 3 of 7
CV-550SPK V3 WATERPROOF KEYPAD
INSTALLATION INSTRUCTIONS
Wiegand Out to Access System (Card/PIN stored in Access System)
Reader Mode Step 1) 03 0#
(Enables data lines to be connected to an Access Controller)
Facility Code Step 2) 60 (0-255) # (Must match Access Controller)
Set D0 & D1 Output Step 3) 61 0 #
(Enables D0 & D1 Wiegand Output data format)
Set Output Bit Length Step 4) 62 (26-66) # (Example of 26 bit: 62 26 #)
PIN Output (5 Digits) Step 5) 64 4 # (1–5-digit key + # key buffered output)
Set 4/8 Bit Burst Output Step 6) 64 (0, 2) # (0 = 4 bit burst, 2 = 8 bit burst, conrm
with Access manufacturer)
Alarm Conguration (D.H.O/F.E.)
Door Held Open (D.H.O.)
35 (0-99) # The set time starts once the door is unlocked, then
it will generate the alarm if the door is not closed. Timing is in
minutes. Closing the door resets the alarm.
Door Forced Open (F.E.) 40 (0-99) #
Door opened with no valid PIN or Card immediately triggers
an alarm.
Timing is in minutes. Master Programming Code resets alarm.
4. WIRING CONNECTIONS FOR DC OR AC POWER
The CV-550SPK V3 keypad can be powered by either DC or AC power within a range of 10V – 28V. When wiring for DC power use
the red wire for positive and the black wire for ground. When wiring for AC power use the red wire (AC1) to one AC wire and light
green wire (AC2) to the other AC wire.
Note: Conrm you are using the light green wire and not the dark green Data 0 wire.
Stand Alone Access Control Keypad
AC2
AC1
D_IN
OPEN
GND
NO
COM
NC
Light Green
RED
BROWN
YELLOW
BLACK
BLUE
PURPLE
ORANGE
Camden Model: CV-550SPK V3
Stand Alone Access Control Keypad
AC2
AC1
D_IN
OPEN
GND
NO
COM
NC
Light Green
RED
BROWN
YELLOW
BLACK
BLUE
PURPLE
ORANGE
Camden Model: CV-550SPK V3
Power
Supply
DC
10-28V
+ve
-ve
Not Used
Relay contacts
To trigger door
strike or
Maglock
Power
Supply
AC
10-28V
Not Used
Relay contacts
To trigger door
strike or
Maglock
Camden Model: CX-TRP-612DC
Camden Model: CX-TRP-4016
Wiring for DC Power (AC1 & gniriW)DNG for AC Power (AC1 & AC2)
Note: Connect corresponding power as shown above to prevent damage to the keypad.

Page 4 of 7
CV-550SPK V3 WATERPROOF KEYPAD
INSTALLATION INSTRUCTIONS
Wiring the CV-550SPK V3 to a Door Operator
Wiring the CV-550SPK V3 to a Fail Secure Door Strike
PowerSupply
12to24VDC
StandAloneAccessControlKeypad
+12V
ALARM
NC
NO
COM
D_IN
OPEN
GND
RED
GREY
ORANGE
BLUE
PURPLE
BROWN
YELLOW
BLACK
Blue
Green
AlarmAnnunciator
Connectpositive
wiretocoloredwire
representingthe
preferredcolorof
thedomelight.
CamdenModel:CM‐AF142SO
(+ve)
PushtoExit
Switch
Camden
Model:CM‐30
Black (‐ve)
Red (+ve)
(+ve)
+
‐
DoorStrike12VDC
CamdenModel:CX‐ED1079DL
(‐)Blue/Green
(+)Red/Black
Grey
White
Orange
Canbesubstituted
withanormallyClosed
DoorPositionSwitch
NormallyOpen
NormallyClosed
CamdenModel:CV‐550SPK
RefertoCXDoorStrikemanualfor24V
connection.
120VAC
WiringtheCV‐550SPKV3toaFailSecureDoorStrike
Power Supply
12 to 24 VDC
Stand Alone Access Control Keypad
+12V
ALARM
NC
NO
COM
D_IN
OPEN
GND
RED
GREY
ORANGE
BLUE
PURPLE
BROWN
YELLOW
BLACK
Blue
Green
Alarm Annunciator
Connect posive
wire to colored wire
represenng the
preferred color of
the dome light.
Camden Model: CM-AF142SO
(+ve)
Push to Exit
Switch
Camden
Model:CM-30
Black(-ve)
Red(+ve)
(+ve)
+
-
Door Operator
Normally Open
Normally Closed
Camden Model: CV-550SPK V3
120 VAC
Wiring the CV-550SPKV3 to a door operator
Door Posion Switch

Page 5 of 7
CV-550SPK V3 WATERPROOF KEYPAD
INSTALLATION INSTRUCTIONS
Wiring the CV-550SPK V3 to a Maglock
Power Supply
12 to 24 VDC
Stand Alone Access Control Keypad
+12V
ALARM
NC
NO
COM
D_IN
OPEN
GND
RED
GREY
ORANGE
BLUE
PURPLE
BROWN
YELLOW
BLACK
Blue
Green
Alarm Annunciator
Connect posive
wire to colored wire
represenng the
preferred color of
the dome light.
Camden Model: CM-AF142SO
(+ve)
Push to Exit
Switch
Camden
Model:CM-30
Black(-ve)
Red(+ve)
(+ve)
+
-
Maglock
Normally Open
Normally Closed
Camden Model: CV-550SPK V3
120 VAC
Wiring the CV-550SPKV3 to a Maglock
Door Posion Switch
Camden Model: CX-90/91 Series
Wiring the CV-550SPK V3 to an External Card Reader and Door Strike
PowerSupply
12to24VDC
+12V
ALARM
NC
NO
COM
D0
D1
D_IN
OPEN
GND
RED
GREY
ORANGE
BLUE
PURPLE
Green
White
BROWN
YELLOW
BLACK
Blue
Green
AlarmAnnunciator
Connectpositive
wiretocoloredwire
representingthe
preferredcolorof
thedomelight.
CamdenModel:CM‐AF142SO
(+ve)
PushtoExitSwitch
CamdenModel:CM‐30
Black (‐ve)
Red (+ve)
(+ve)
+
‐
NormallyOpen
CamdenModel:CV‐550SPKv3
120VAC
WiringtheCV‐550SPKV3toanexternalcardreaderanddoorstrike
DoorPositionSwitch
5‐16VDC
Ground
Data0
Data1
ExternalWiegandCardReader
NormallyClosed
DoorStrike12VDC
(+)
(‐)
(CanbereplacedwithaMOV)
CamdenModel:
CX‐ED1079
D1
CamdenModel:CV‐7400
StandAloneKeypad
Mustbeconfiguredforsingledoormode

Page 6 of 7
CV-550SPK V3 WATERPROOF KEYPAD
INSTALLATION INSTRUCTIONS
5. INSTALLATION
CV-550SPK V3 Wall Flush Mounng with Rain/Privacy Shield:
Note: Make necessary arrangements for wiring before
Mounng the Keypad to the wall.
1. Remove the mang screw located at the boom of the
keypad, allowing you to mount the keypad with the Rain/Privacy
Shield to the wall.
2. Spot drill hole on the wall and take the supplied Self
threading screws to ghten back of the Keypad to the
Rain/Privacy Shield.
3. Place the front of the keypad onto the back of the
keypad then ghten with the mang screw to keep keypad
in place.
Rain/Privacy Shield
CV-550SPK V3
Thread screws
through these
four holes
Rain/Privacy Shield
3"
[76mm]
2"
[50mm]
CV-550SPK V3 Inwall Electrical Box Flush
Mounng with Rain/Privacy Shield:
Note: Thread the Keypad wire through the rain
hood to make necessary arrangements for wiring
before Mounng the Keypad.
1. Remove the mang screw located at the
boom of the keypad, allowing you to mount the
keypad with the Rain/Privacy Shield to the Electrical Box.
2. Take the supplied #6-32 screws and place it
through the center top and boom holes on the
Keypad back plate, through the Rain/Privacy Shield then
ghten screws to keep the plate and Rain/Privacy Shield
onto the electrical box.
3. Place the front of the keypad onto the back
of the keypad then ghten with the mang screw
to keep keypad in place.
Inwall SingleGang
Electrical Box
Rain/Privacy Shield
CV-550SPK V3
6-32 Mounting
Screw
Mating Screw
CV-550SPK V3 Wall Flush Mounng with Rain/Privacy Shield:
Note: Make necessary arrangements for wiring before
Mounng the Keypad to the wall.
1. Remove the mang screw located at the boom of the
keypad, allowing you to mount the keypad with the Rain/Privacy
Shield to the wall.
2. Spot drill hole on the wall and take the supplied Self
threading screws to ghten back of the Keypad to the
Rain/Privacy Shield.
3. Place the front of the keypad onto the back of the
keypad then ghten with the mang screw to keep keypad
in place.
Rain/Privacy Shield
CV-550SPK V3 Thread screws
through these
four holes
Rain/Privacy Shield
3"
[76mm]
2"
[50mm]
CV-550SPK V3 Inwall Electrical Box Flush
Mounng with Rain/Privacy Shield:
Note: Thread the Keypad wire through the rain
hood to make necessary arrangements for wiring
before Mounng the Keypad.
1. Remove the mang screw located at the
boom of the keypad, allowing you to mount the
keypad with the Rain/Privacy Shield to the Electrical Box.
2. Take the supplied #6-32 screws and place it
through the center top and boom holes on the
Keypad back plate, through the Rain/Privacy Shield then
ghten screws to keep the plate and Rain/Privacy Shield
onto the electrical box.
3. Place the front of the keypad onto the back
of the keypad then ghten with the mang screw
to keep keypad in place.
Inwall SingleGang
Electrical Box
Rain/Privacy Shield
CV-550SPK V3
6-32 Mounting
Screw
Mating Screw
Wiring the CV-550SPK V3 to an Access Controller (Wiegand Out)
Single-Door Standalone Access Controller
+12V
ALARM
NC
NO
COM
D_IN
OPEN
GND
Red
Grey
Orange
Blue
Purple
Brown
Yellow
Black
+ - D0 D1
Access Controller
Reader Terminal
D0
D1 White
Green

Call: 1.877.226.3369 / 905.366.3377
Visit: www.camdencontrols.com
Opening New Doors to
Innovation, Quality and Support!
Page 7 of 7
CV-550SPK V3 WATERPROOF KEYPAD
INSTALLATION INSTRUCTIONS
File: 40-82B304_CV-550SPK_V3.indd
Rev.: June 20th 2022
Part No.: 40-82B304
FCC ID: 2A48H-CV-550SPK
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help
For more comprehensive info refer to document: 40-82B306 CV-550SPK v3 Reference Manual
Other manuals for CV-550SPK V3
1
Table of contents
Other CAMDEN Controllers manuals
Popular Controllers manuals by other brands

Griffin Technology
Griffin Technology PowerMate quick start guide

Paradise Datacom
Paradise Datacom GL33120 instruction manual

Texas Instruments
Texas Instruments Stellaris MDL-BDC24 Getting started guide

Vag
Vag ROTOP Installation and operation instructions

Zonet
Zonet ZFN2601 Quick installation guide

sisel
sisel ENDA ET1413R quick start guide

SEW-Eurodrive
SEW-Eurodrive MOVIFIT compact operating instructions

Larson Electronics
Larson Electronics Golight 2020 instruction manual

Panasonic
Panasonic MINAS A6 Series quick start guide

TIS
TIS ES-10F-CM Manual Installation

YASKAWA
YASKAWA DS031 installation instructions

dIXEL
dIXEL IPC400D SERIES user manual