CAMDEN WC13 Series User manual

Page 2 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
Page 1 of 18
WC13 Series Restroom Control
INSTALLATION INSTRUCTIONS
Electrified Locks, Relays and Timers
1. GENERAL DESCRIPTION
The Restroom Control Kit allows access in and out of a restroom,
with the ability to secure the door so patrons are aware that the
location is either occupied or vacant.
The CX-WC13 Series of Restroom Control Kits are controlled by
Camden’s advanced relay logic controller, part number CX-33.
CX-33 currently has 15 pre-set modes that will accommodate
most Restroom, Vestibule and Card Access related applications.
The kits are available with many dierent switch/button
congurations including a wireless solution. When used to
control a Restroom application, the modes most often used will
be Mode 7 (normally unlocked) or Mode 8 (normally locked).
Each Restroom Control Kit will have the ability to physically
open the door then allow the patron to lock the door once
inside. When locked the CX-33 will change the color of the inside
PUSH TO LOCK and outside PUSH TO OPEN buttons from
green to red, displaying that the Restroom is in use. When the
inside PUSH TO OPEN is pressed, it will unlock the door, then
physically open the door and change the color of the outside
PUSH TO OPEN and inside PUSH TO LOCK buttons back to
green displaying that the Restroom is now vacant.. The locked
Restroom can be unlocked by either pressing the inside PUSH
TO OPEN which will reset the system back to unlocked, or by
using the crash bar, paddle or turning the knob set to open the
door contact circuit and resetting the CX-33.
The CX-WC13 Series of Restroom Control Kits kit uses Camden’s
trademark Aura boards. The Aura circuit board is installed
behind the outside PUSH TO OPEN and inside PUSH TO LOCK
push buttons on either side of the door and can be seen easily
seen by patrons at a distance.
The coloring of the Auras can be congured in dierent
ways to suit the application. Its color choices are red,
green and blue.
2. INSTALLATION
Operation at a Glance
When the exterior PUSH TO OPEN button is pressed, it will
trigger the PBTN input on its Aura board, causing its N.O. relay
contact to send a momentary closure to DRY 1 on the CX-33,
allowing the door to swing open. When the interior PUSH TO
LOCK button is pressed, it will trigger the PBTN input on its
Aura board, causing its N.O. relay contact to send a momentary
closure to DRY 3, causing the CX-33 to lock the Restroom and
switch the Aura colors from green to red. The inside PUSH TO
OPEN button is wired directly to DRY 2 on the CX-33. When
pressed, the Restroom will unlock and the door will swing open.
The Restroom can also be unlocked by opening the door from
the inside, which will break the door contact circuit, causing the
CX-33 to reset and unlock the door. The Aura’s will switch back
to green signalling the Restroom is now vacant.
Mounting
IMPORTANT: Do not apply power until you have read the
instructions fully and made the required adjustments.
The CX-33 should be mounted in a clean dry location out of
direct contact with the elements. Suitable locations include
inside a metal enclosure, operator header, or above a false
ceiling. The Display & LED’s are visible through the clear plastic
case, which also has cut-outs for the programming buttons and
terminal strips. Once the unit has been wired and adjusted, it
may be tucked up into the operator header or axed using the
supplied Velcro or 2 sheet metal screws.
Note: Some Door Operators provide excessive voltage
levels above their posted values. Always measure voltages
provided on both the VDC & VAC scales sources rst before
applying power to any part of the Restroom Control Kit.
Wiring of this unit is dependent on the mode selected, however
the following commonalities apply: The unit will operate on 12
or 24 volts, AC or DC. Connect to Terminals 1 & 2, which are
non-polarity sensitive. NOTE: We highly recommend the use of
a regulated power supply when powering equipment in certain
modes such as the barrier-free restroom application, where the
strike power may be maintained from a few minutes to many
hours. We oer a low-cost board-only regulated power supply
- CX-PS13 V3, which will supply clean, ltered & regulated 12 or
24VDC power for the strike and CX-33.
Wiring the CX-WC13 Series Restroom Control
Kit is as follows:
Inputs:
Dry 1 & Input: The exterior PUSH TO OPEN button is wired
to the PBTN input on its Aura board. The Aura’s common
and normally open relay contacts are then wired to DRY 1
& Input on the CX-33.
The REM inputs are wired in parallel with all other Aura board
REM inputs being used in the application. Then the paralleled
Aura’s are wired to Relay 3 (N.O.) on the CX-33.
DRY 2 & Input: The interior PUSH TO OPEN is wired directly to
the CX-33’s DRY 2 & Input.
DRY 3 & Input: The interior PUSH TO LOCK is wired to the Aura
boards PBTN input. The Aura’s common and normally open
relay contacts are then wired to DRY 3 & Input on the CX-33.
DRY 4 & Input: The door contact (normally closed when the
door is closed) is wired to DRY 4 & Input.
Power is then run to the power inputs of the Aura boards.
Outputs
Relay 1: Used for lock control. Wire the strike and provide
power (N.O.- Mode 7, & Mode 8).
Relay 2: Used for Door Operator control. Wire the Operator
(N.O.).
Relay 3: Used for Aura color switching. All Aura’s get wired in
parallel and wired to Relay 3 (N.O.).
Note: ensure correct polarity when wiring Aura’s in parallel.
Programming the CX-33
The CX-33 has two Restroom applications (Mode 7 & 8).
Determining which one is correct for you will be based on
whether the Restroom will be normally unlocked (Mode 7)
or normally locked (Mode 8).
Selecting a Mode
To select a mode, press and release the “MENU” button on the
CX-33. Then use the “UP” or “DOWN” buttons to get to Mode
7 or 8. When the screen displays only the Mode number, it is
ready to use.
Editing the Settings for a Mode
Camden builds in typical times for lock release and door
operator activation and is ready to use without changing any
parameters. If you need to change the timing or delay for an
output, it can be done by pressing the “MENU” button within
the mode you selected. Once the option is selected you can
use the “UP or DOWN” buttons to select the timing needed.
The rst option (H & 1 ashing) will be how long relay 1 will be
activated for (0-50 seconds). The second option (d & 1 ashing)
will be how long to wait before activating relay 2 (0-15 seconds).
The third option (H & 2 ashing) will be how long relay 2 will be
activated for (0-50 seconds). The fourth option (d & 2 ashing)
will be how long to wait before activating relay 3 (0-15 seconds).
Factory Reset (Defaulting the CX-33)
To return the CX-33 back to its factory default settings you will
need to remove power, then hold down the “MENU” button
while powering up the CX-33. Once started, you will see the
rmware version listed, then a number “1” will be displayed.
Reconnect your power and press the “MENU” button once then
1. Restroom Control Models 2. Wiring Drawing Reference
3. CX-WC13XFM 4. DRG-CX-WC-13-7 Or DRG-CX-WC-13-8
5. CX-WC13AXFM 6. CX-WC13AXFM-7 Or CX-WC13AXFM-8
7. CX-WC13FM&WEC-10 8. DRG-CX-WC-13-8 Or DRG-CX-WC-13-7
9. CX-WC13AXFM&WEC-10 10.CX-WC13AXFM&WEC-10-7 Or CX-WC13AXFM&WEC-10-7
11.CX-WC13AXFM&WEC-10K2 12.CX-WC13AXFM&WEC-10-8 Or CX-WC13AXFM&WEC-10-8

Page 4 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
Page 3 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
CM-55GR WIRING DIAGRAM (TYPICAL) - PUSH TO LOCK CM-55GR WIRING DIAGRAM & CM-2520 COMBO SWITCH
CX-33
Menu Up Down
LED 1
LED 2
LED 3
Display
Multi-function Relay
Push to open Push to Lock
Aura insert
Power
12/24
AC/DC
Dry 1
Input
Dry 2
+ wet
- Input
Input
Dry 3
Input
Dry 4
Input
Com
N/C
Com
N/O
N/C
Com
N/O
N/C
N/O
Relay 1 Relay 2 Relay 3
- REM + - PBTN + EN RF/TX- PWR+
NC COM NO PWR AC/DC
Wiring Diagram & Cm-2520 Combo switch
Power & Relay
Terminal Strip
Dipswitch Switch mounng holes (x2)
Box mounng screw locaons
(hidden under circuit board)
(x4)
CM-54 Enclosure
12 / 24 V
AC/DC
Power
Wire Access Hole
Push to Lock
Aura insert
CX-33
Menu Up Down
LED 1
LED 2
LED 3
Power
12/24
AC/DC
Dry 1
Input
Dry 2
+ wet
- Input
Input
Dry 3
Input
Dry 4
Input
Com
N/C
Com
N/O
N/C
Com
N/O
N/C
N/O
Relay 1 Relay 2 Relay 3
Display
Multi-function Relay
- REM + - PBTN + EN RF/TX- PWR+
NC COM NO PWR AC/DC
SW2 Dipswitch Switch mounng holes (x2)
Box mounng screw locaons
(hidden under circuit board)
(x4)
CM-54 Enclosure
Wiring Diagram (Typical)
12 / 24 V
AC/DC
Power
Power & Relay
Terminal Strip
Wire Access Hole
Note:
1. Power terminals are not polarity sensitive.
2. Typical installation shown, where remote device
changes LED colour. If it's desired to have switch
activation change LED colour, then set REMote/
LOCal dip on SW1 to local, and do not wire to
the REMOTE terminals.
Note:
1. Power terminals are not polarity sensitive.
2. Typical installation shown, where remote device
changes LED colour. If it's desired to have switch
activation change LED colour, then set REMote/
LOCal dip on SW1 to local, and do not wire to
the REMOTE terminals.

Page 6 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
Page 5 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
FLUSH MOUNT RESTROOM INSTALLATION
Flush
Aura Enclosure
Black Vinyl
Dry Wall
Bracket
8-32 x 1 1/2
Phillips Screw
(2pcs)
#6x3/8 Phillips
self-tapping screw
(2pcs)
Label
Aura Insert
Aura Board
Plastic spacer
6-32 Phillips
Screw (2pcs)
(For Use only on CM-2520/48)
1. Prepare the cut-out for the unit and t in the dry wall bracket.
2. Slide in the black vinyl behind the ush aura enclosure and t
them inside the dry wall bracket.
Note: Black vinyl does not come with the CM-45/4 - 4 1/2"
'Push To Open'.
3. Ensure the two mounting holes on the bracket and the Flush
aura enclosure align. Use the 8-32 phillips screws to completely
tighten in place.
4. Place the aura board inside the ush aura enclosure, making
sure the screw holes on the aura board align with the screw
holes inside the Flush aura enclosure. Use the #6 x 3/8"
self-tapping screws to tighten Aura board in place.
5. Place the Aura insert inside the Flush aura enclosure, making
sure the mounting screw holes on the aura insert and the ush
aura enclosure align.
FOR CM-45/455SE1, CM-45/855SE1 & CM-45/4 SWITCHES
a. Use the 6-32 hex head screws to tighten the aura
insert slightly.
b. Fit in the assembled Push plate by locating the screws
with the holes on the backplate.
c. Fit the hex key through the hole on the face plate and
completely tighten the 6-32 screws in place.
FOR CM-2520-4855SE1 COMBO SWITCH
a. Fit the plastic spacer inside the aura insert
b. Place the combo switch Inside the aura insert, making sure
the mounting holes on the aura and on the back plate align.
c. Use the 6-32 Phillips screws to tighten in place
7. Apply the label to the black vinyl as required.
Note:
Use this drawing for the follow Restroom
Control Models:
1. CX-WC13XFM - Illuminated switch system
2. CX-WC13AXFM - Illuminated switch system
3.CX-WC13XFM & WEC-10 - Illuminated switch
and emergency call system
4. CX-WC13AXFM & WEC-10K2 - Illuminated switch
and emergency call system
SURFACE MOUNT RESTROOM INSTALLATION
1. Place the white vinyl behind the surface aura enclosure and
place them against the mounting wall.
2. Use the #10 x 1'' pan head screws with the green pvc anchors
provided to hold the white vinyl and the aura enclosure against
the wall .
Note: White vinyl does not come with the CM-45/4 - 4 1/2"
'Push To Open'.
3. Place all the square rubber pads inside the ush aura enclosure.
Insert the aura board inside the ush aura enclosure, making
sure the screw holes on the aura board align with the screw
holes inside the surface aura enclosure. Use the #6 x 3/8"
self-tapping screws to tighten Aura board in place.
4. Place the Aura insert inside the surface aura enclosure, making
sure the mounting screw holes on the aura insert and the
surface aura enclosure align.
FOR CM-45/454SE1, CM-45/854SE1 & CM-45/4 SWITCHES
a. Use the 6-32 hex head screws to tighten the aura
insert slightly.
b. Fit in the assembled CM-45/4 by locating the screws
with the holes on the backplate.
c. Fit the hex key through the hole on the face plate and
completely tighten the 6-32 screws in place.
FOR CM-2520-4854SE1 COMBO SWITCH
a. Fit the plastic spacer inside the aura insert
b. Place the combo switch Inside the aura insert, making sure
the mounting holes on the aura and on the back plate align
c. Use the 6-32 Phillips screws to tighten in place.
5. Apply the label to the black vinyl as required.
Note:
Use this drawing for the follow Restroom
Control Models:
1. CX-WC13XSM - Illuminated switch system
2. CX-WC13ASFM - Illuminated switch system
3. CX-WC13XSM & WEC-10 - Illuminated switch
and emergency call system
4. CX-WC13AXSM & WEC-10K2 - Illuminated switch
and emergency call system
White Vinyl
Label
#10x1'' Pan Head
screw (4pcs)
5/8'' x 5/8''
Square Rubber Pad
(4pcs)
Surface
Aura Enclosure
#6x3/8'' Phillips
self-tapping screw
(2pcs)
Aura Insert
Aura Board
Plastic spacer
6-32 Phillips
Screw (2pcs)
(For Use only on CM-2520/48)
Inside
Wall Switch
(always unlocks
& opens door)
FILENAME :
WC-13 -7 wiring diagram_R2
DRAWING No: DRG-CX -WC-13-7
WC-13 Washroom Package Wiring Diagram (normally unlocked)
SCALE: NONE DRAWN BY : DGW REV: 2DATE : 03/07/17
Magnetic
Contact
Switch
Fail-Safe Electric
Strike Shown
Outside Wall Switch
CM-45/455SE1 (or similar)
Inside ‘Push-to-Lock’
CM-45/855SE1 (or similar)
MOV
Wire MOV (supplied)
directly to strike
(If Fail-Secure lock is used,
wire to Terminals 1 & 2)
N.C.
Contacts closed
when Door
is closed
12 / 24 VDC
Power
For Strike
12/24V
Power
Remote
N.O.
Relay
Output
LED 1
LED 2
LED 3
DISPLAY
Relay 1 Relay 2 Relay 3
N/C
N/O
COM
N/C
N/O
COM
N/C
N/O
COM
POWER
12/24V
AC/DC
DRY 1
DRY 2
DRY 3
DRY 4
+ WET
INPUT
INPUT
INPUT
INPUT
- INPUT
MENU UP DOWN
0.0.7
Door Operator
12/24V
Power
Remote
N.O.
Relay
Output
Important:
Ensure wiring polarity is consistent
from Relay 3 to each Aura Remote
Input terminals
+
-
Part# 40-82D003
CAMDEN DOOR CONTROLS
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
12 - 24 V
AC/DC
Power
PUSH
TO
OPEN
PUSH
TO OPEN
PUSH
TO
LOCK
CX-33
Note:
This Drawing should be used in addition
to each products respective Installation
Manual (not in place of).
Aura
Dip Switch
Settings
1REM/LOC
RELAY
SPEAKER
2
3
Enable
ON
1RED
GREEN
BLUE
RED
GREEN
BLUE
2
3
Active Color
ON
1
2
3
Idle Color
ON
= Switch Position
Inside
Wall Switch
(always unlocks
& opens door)
FILENAME :
WC-13 -7 wiring diagram_R2
DRAWING No: DRG-CX -WC-13-7
WC-13 Washroom Package Wiring Diagram (normally unlocked)
SCALE: NONE DRAWN BY : DGW REV: 2DATE : 03/07/17
Magnetic
Contact
Switch
Fail-Safe Electric
Strike Shown
Outside Wall Switch
CM-45/455SE1 (or similar)
Inside ‘Push-to-Lock’
CM-45/855SE1 (or similar)
MOV
Wire MOV (supplied)
directly to strike
(If Fail-Secure lock is used,
wire to Terminals 1 & 2)
N.C.
Contacts closed
when Door
is closed
12 / 24 VDC
Power
For Strike
12/24V
Power
Remote
N.O.
Relay
Output
LED 1
LED 2
LED 3
DISPLAY
Relay 1 Relay 2 Relay 3
N/C
N/O
COM
N/C
N/O
COM
N/C
N/O
COM
POWER
12/24V
AC/DC
DRY 1
DRY 2
DRY 3
DRY 4
+ WET
INPUT
INPUT
INPUT
INPUT
- INPUT
MENU UP DOWN
0.0.7
Door Operator
12/24V
Power
Remote
N.O.
Relay
Output
Important:
Ensure wiring polarity is consistent
from Relay 3 to each Aura Remote
Input terminals
+
-
Part# 40-82D003
CAMDEN DOOR CONTROLS
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
12 - 24 V
AC/DC
Power
PUSH
TO
OPEN
PUSH
TO OPEN
PUSH
TO
LOCK
CX-33
Note:
This Drawing should be used in addition
to each products respective Installation
Manual (not in place of).
Aura
Dip Switch
Settings
1REM/LOC
RELAY
SPEAKER
2
3
Enable
ON
1RED
GREEN
BLUE
RED
GREEN
BLUE
2
3
Active Color
ON
1
2
3
Idle Color
ON
= Switch Position

Call: 1.877.226.3369 / 905.366.3377
Visit: www.camdencontrols.com
Opening New Doors to
Innovation, Quality and Support!
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
Page 8 of 18Page 7 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
File: WC13 Restroom Controls
Manual_Eng_R1.indd
Revision: March 1st 2021
Part No: 40-82B230
Questions? Call us toll-free at 1-877-226-3369 or technical support 905-366-3377 (ext. 505)
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
Notes:
Item Part Number Description
60-31A037 Red/Green Aura PC Board
60-42C012 Square Aura Insert
CX-33 Advance Logic Relay Control
CX-MDA Magnetic Door Contact
60-42C019
Mounting Box, Flush Aura Enclosure.
Flame/Impact Resistant Black Polymer (ABS)
6-1/2"W X 6-1/2"H X 2"D
60-42C010
Mounting Box, Surface Aura Enclosure.
Flame/Impact Resistant Black Polymer (ABS)
5-1/4"W X 5-1/4"H X 2"D
Black Vinyl & Sign for Flush Aura Enclosure
CM-SFE1 Black Vinyl & English Label
“DOOR LOCKED WHEN RED/OCCUPIED WHEN GREEN’’
CM-SFF1 Black Vinyl & French Label “LIBRE/OCCUPÉ’’
CM-SFFE1
Black Vinyl & English Label
“DOOR LOCKED WHEN RED/OCCUPIED WHEN GREEN’’
Black Vinyl & 2-sided French Label “LIBRE/OCCUPÉ’’
White Vinyl & Sign for Surface Aura Enclosure
CM-SE1 White Vinyl & English Label
“DOOR LOCKED WHEN RED/ OCCUPIED WHEN GREEN’’
CM-SF1 White Vinyl & French Label “LIBRE/OCCUPÉ’’
CM-SEFE1
White Vinyl & English Label
“DOOR LOCKED WHEN RED/OCCUPIED WHEN GREEN’’
White Vinyl & 2-sided French Label “LIBRE/OCCUPÉ’’
ORDERING INFORMATION FOR REPLACEMENT PARTS

Page 9 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
Inside
Wall Switch
(always unlocks
& opens door)
FILENAME :
WC-13-7 wiring diagram_R2
DRAWING No: DRG -CX -WC-13-7
WC-13 Washroom Package Wiring Diagram (normally unlocked)
SCALE: NONE DRAWN BY : DGW REV: 2DATE : 03/07/17
Magnetic
Contact
Switch
Fail-Safe Electric
Strike Shown
Outside Wall Switch
CM-45/455SE1 (or similar)
Inside ‘Push-to-Lock’
CM-45/855SE1 (or similar)
MOV
Wire MOV (supplied)
directly to strike
(If Fail-Secure lock is used,
wire to Terminals 1 & 2)
N.C.
Contacts closed
when Door
is closed
12 / 24 VDC
Power
For Strike
12/24V
Power
Remote
N.O.
Relay
Output
LED 1
LED 2
LED 3
DISPLAY
Relay 1 Relay 2 Relay 3
N/C
N/O
COM
N/C
N/O
COM
N/C
N/O
COM
POWER
12/24V
AC/DC
DRY 1
DRY 2
DRY 3
DRY 4
+ WET
INPUT
INPUT
INPUT
INPUT
- INPUT
MENU UP DOWN
0.0.7
Door Operator
12/24V
Power
Remote
N.O.
Relay
Output
Important:
Ensure wiring polarity is consistent
from Relay 3 to each Aura Remote
Input terminals
+
-
Part# 40-82D003
CAMDEN DOOR CONTROLS
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
12 - 24 V
AC/DC
Power
PUSH
TO
OPEN
PUSH
TO OPEN
PUSH
TO
LOCK
CX-33
Note:
This Drawing should be used in addition
to each products respective Installation
Manual (not in place of).
Aura
Dip Switch
Settings
1REM/LOC
RELAY
SPEAKER
2
3
Enable
ON
1RED
GREEN
BLUE
RED
GREEN
BLUE
2
3
Active Color
ON
1
2
3
Idle Color
ON
= Switch Position

Page 10 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
Inside
Wall Switch
(always unlocks
& opens door)
FILENAME:WC-13 -8 wiring diagram_R2
DRAWING No: DRG -CX -WC -13-8
WC-13 Washroom Package Wiring Diagram (normally locked)
SCALE: NONE DRAWN BY: DGW REV: 2DATE:03/07/17
MOV
N.C.
Contacts closed
when Door
is closed
12 / 24 VDC
Power
For Strike
12/24V
Power
Remote
N.O.
Relay
Output
LED 1
LED 2
LED 3
DISPLAY
Relay 1Relay 2Relay 3
N/C
N/O
COM
N/C
N/O
COM
N/C
N/O
COM
POWER
12/24V
AC/DC
DRY 1
DRY 2
DRY 3
DRY 4
+ WET
INPUT
INPUT
INPUT
INPUT
- INPUT
MENU UP DOWN
0.0.8
PUSH
TO
OPEN
12/24V
Power
Remote
N.O.
Relay
Output
+
-
Part # 40-82D003
CAMDEN DOOR CONTROLS
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
12 - 24 V
AC/DC
Power
Important:
Ensure wiring polarity is consistent
from Relay 3 to each Aura Remote
Input terminals
Door Operator
Fail-Secure Electric
Strike Shown
(If Fail-Safe lock is used,
wire to Terminals 1 & 2)
Wire MOV (supplied)
directly to strike
Magnetic
Contact
Switch
Outside Wall Switch
CM-45/455SE1 (or similar)
Inside ‘Push-to-Lock’
CM-45/855SE1 (or similar)
Aura
Dip Switch
Settings
1REM/LOC
RELAY
SPEAKER
2
3
Enable
ON
1RED
GREEN
BLUE
RED
GREEN
BLUE
2
3
Active Color
ON
1
2
3
Idle Color
ON
= Switch Position
CX-33
PUSH
TO OPEN
PUSH
TO
LOCK
Note:
This Drawing should be used in addition
to each products respective Installation
Manual (not in place of).

Page 11 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
FILENAME:
DRAWING No:
SCALE: NONE DRAWN BY: JML REVISED :DATE:
Outside Wall Switch
CM-45/455SE1
CM-2520/4855SE1
(or similar)
MOV
N.C.
Contacts closed
when Door
is closed
12 / 24 VDC
Power
For Strike
(or similar)
12/24V
Power
Remote
N.O.
Relay
Output
LED 1
LED 2
LED 3
DISPLAY
Relay 1Relay 2Relay 3
N/C
N/O
COM
N/C
N/O
COM
N/C
N/O
COM
POWER
12/24V
AC/DC
DRY 1
DRY 2
DRY 3
DRY 4
+ WET
INPUT
INPUT
INPUT
INPUT
- INPUT
MENU UP DOWN
0.0.7
Door Operator
12/24V
Power
Remote
N.O.
Relay
Output
+
-
Part # 40-82D016
CAMDEN DOOR CONTROLS
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
PUSH
TO
OPEN
PUSH
TO
LOCK
Push
To Open
Inside
‘Push To Open’ (always unlocks & opens door)
& ‘Push to Lock’ combination Switch
WC13AXFM/SM Washroom Package Wiring Diagram (normally unlocked)
CX-WC13AXFM-7 CX-WC13AXFM-7.AI
May 14, 2018
CX-33
12 - 24 V
AC/DC
Power
PUSH
TO OPEN
Important:
Ensure wiring polarity is consistent
from Relay 3 to each Aura Remote
Input terminals
Note:
This Drawing should be used in addition
to each products respective Installation
Manual (not in place of).
Fail-Safe Electric
Strike Shown
(If Fail-Secure lock is used,
wire to Terminals 1 & 2)
Wire MOV (supplied)
directly to strike
Magnetic
Contact
Switch
Aura
Dip Switch
Settings
1REM/LOC
RELAY
SPEAKER
2
3
Enable
ON
1RED
GREEN
BLUE
RED
GREEN
BLUE
2
3
Active Color
ON
1
2
3
Idle Color
ON
= Switch Position

Page 12 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
FILENAME :
DRAWING No:
SCALE: NONE DRAWN BY: JML REVISED :DATE:
CM-2520/4855SE1 (or similar)
MOV
N.C.
Contacts closed
when Door
is closed
12 / 24 VDC
Power
For Strike
12/24V
Power
Remote
N.O.
Relay
Output
LED 1
LED 2
LED 3
DISPLAY
Relay 1Relay 2Relay 3
N/C
N/O
COM
N/C
N/O
COM
N/C
N/O
COM
POWER
12/24V
AC/DC
DRY 1
DRY 2
DRY 3
DRY 4
+ WET
INPUT
INPUT
INPUT
INPUT
- INPUT
MENU UP DOWN
0.0.8
PUSH
TO OPEN
12/24V
Power
Remote
N.O.
Relay
Output
+
-
Part# 40-82D016
CAMDEN DOOR CONTROLS
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
PUSH
TO
OPEN
PUSH
TO
LOCK
Push
To Open
Inside
‘Push To Open’ (always unlocks & opens door)
& ‘Push to Lock’ combination Switch
WC13AXFM/SM Washroom Package Wiring Diagram (normally locked)
CX-WC13AXFM-8 CX-WC13AXFM-8.AI
May 14, 2018
CX-33
12 - 24 V
AC/DC
Power
Door Operator
Important:
Ensure wiring polarity is consistent
from Relay 3 to each Aura Remote
Input terminals
Note:
This Drawing should be used in addition
to each products respective Installation
Manual (not in place of).
Outside Wall Switch
CM-45/455SE1 (or similar)
Wire MOV (supplied)
directly to strike
Magnetic
Contact
Switch
Fail-Secure Electric
Strike Shown
(If Fail-Safe lock is used,
wire to Terminals 1 & 2)
Aura
Dip Switch
Settings
1REM/LOC
RELAY
SPEAKER
2
3
Enable
ON
1RED
GREEN
BLUE
RED
GREEN
BLUE
2
3
Active Color
ON
1
2
3
Idle Color
ON
= Switch Position

Page 13 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
PUSH
TO OPEN
N.C.
Door Operator
Remote
+
-
Part# 40-82D017
-V+V
1
2
3
4
LED 1
CX-33
LED 2
LED 3
DISPLAY
Relay 1 Relay 2 Relay 3
N/C
N/C
N/O
N/O
N/O
N/C
COM
COM
COM
POWER
12/24V
AC/DC
DRY 1
DRY 2
DRY 3
DRY 4
+ WET
INPUT
INPUT
INPUT
INPUT
- INPUT
MENU UP DOWN
0.0.7
12-24 VDC
Power for
Strike
Magnetic
Contact
Switch
Contact closed
when door is
closed
12/24V
Power
N.O.
Relay
Output
Outside Wall Switch
CM-45/455SE1 (or similar)
CM-450R/12
CM-AF501SO
CM-AF141SO
+24 VDC Power
Supply
GRY
BLK
N/O N/C
BLK MOV
GRY
CM-2520/4855SE1 (or similar)
12/ 24V
Power
Remote
N.O.
Relay
Output
PUSH
TO
OPEN
PUSH
TO
LOCK
Push To
Open
Inside
‘Push To Open (always unlocks & opens door)
& Push to Lock’ combination Switch
12 - 24 V
AC/DC
Power
Note:
This Drawing should be used in addition
to each products respective Installation
Manual (not in place of).
Important:
Ensure wiring polarity is consistent
from Relay 3 to each Aura Remote
Input terminals
CX-WC13AXFM/SM & WEC10 Single Door Restroom (Normally unlocked)
CAMDEN DOOR CONTROLS
SCALE: NONE
DRAWING No: CX-WC13AXFM-WEC10-7
FILE NAME: WC-13AXFM-7-WEC10 wiring diagram_R1
DRAWN BY: JML DATE: 05-18-2018 REV: 2
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
Fail-Secure Electric
Strike Shown
(If Fail-Secure lock is
used, wire to Terminals
NC & COM)
Wire MOV
(supplied)
directly to strike
Aura
Dip Switch
Settings
1REM/LOC
RELAY
SPEAKER
2
3
Enable
ON
1RED
GREEN
BLUE
RED
GREEN
BLUE
2
3
Active Color
ON
1
2
3
Idle Color
ON
= Switch Position

Page 14 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
PUSH
TO OPEN
N.C.
Door Operator
Remote
+
-
Part# 40-82D017
-V+V
1
2
3
4
LED 1
CX-33
LED 2
LED 3
DISPLAY
Relay 1 Relay 2 Relay 3
N/C
N/C
N/O
N/O
N/O
N/C
COM
COM
COM
POWER
12/24V
AC/DC
DRY 1
DRY 2
DRY 3
DRY 4
+ WET
INPUT
INPUT
INPUT
INPUT
- INPUT
MENU UP DOWN
0.0.7
12-24 VDC
Power for
Strike
Magnetic
Contact
Switch
Contact closed
when door is
closed
12/24V
Power
N.O.
Relay
Output
Outside Wall Switch
CM-45/455SE1 (or similar)
CM-450R/12
CM-AF501SO
CM-AF141SO
+24 VDC Power
Supply
GRY
BLK
N/O N/C
BLK MOV
GRY
CM-2520/4855SE1 (or similar)
12/ 24V
Power
Remote
N.O.
Relay
Output
PUSH
TO
OPEN
PUSH
TO
LOCK
Push To
Open
Inside
‘Push To Open (always unlocks & opens door)
& Push to Lock’ combination Switch
12 - 24 V
AC/DC
Power
Note:
This Drawing should be used in addition
to each products respective Installation
Manual (not in place of).
Important:
Ensure wiring polarity is consistent
from Relay 3 to each Aura Remote
Input terminals
CX-WC13AXFM/SM & WEC10 Single Door Restroom (Normally unlocked)
CAMDEN DOOR CONTROLS
SCALE: NONE
DRAWING No: CX-WC13AXFM-WEC10-7
FILE NAME: WC-13AXFM-7-WEC10 wiring diagram_R1
DRAWN BY: JML DATE: 05-18-2018 REV: 2
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
Fail-Secure Electric
Strike Shown
(If Fail-Secure lock is
used, wire to Terminals
NC & COM)
Wire MOV
(supplied)
directly to strike
Aura
Dip Switch
Settings
1REM/LOC
RELAY
SPEAKER
2
3
Enable
ON
1RED
GREEN
BLUE
RED
GREEN
BLUE
2
3
Active Color
ON
1
2
3
Idle Color
ON
= Switch Position

Page 15 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
PUSH
TO OPEN
PUSH
TO LOCK
N.C.
Door Operator
Remote
+
-
Part# 40-82D003
-V+V
1
2
3
4
PUSH
TO OPEN
LED 1
CX-33
LED 2
LED 3
DISPLAY
Relay 1 Relay 2 Relay 3
N/C
N/C
N/O
N/O
N/O
N/C
COM
COM
COM
POWER
12/24V
AC/DC
DRY 1
DRY 2
DRY 3
DRY 4
+ WET
INPUT
INPUT
INPUT
INPUT
- INPUT
MENU UP DOWN
0.0.7
12-24 VDC
Power for
Strike
Magnetic
Contact
Switch
Contact closed
when door is
closed
12/24V
Power
N.O.
Relay
Output
Remote
12/24V
Power
N.O.
Relay
Output
Inside
Wall Switch
(always unlocks
and opens door)
Outside Wall Switch
CM-45/455SE1 (or similar)
Inside PUSH TO LOCK
CM-45/855SE1 (or similar)
CM-450R/12
CM-AF501SO
CM-AF141SO
+24 VDC Power
Supply
GRY
BLK
N/O N/C
BLK
MOV
GRY
12 - 24 V
AC/DC
Power
Note:
This Drawing should be used in addition
to each products respective Installation
Manual (not in place of).
Fail-Safe Electric
Strike Shown
(If Fail-Secure lockis used,
wire to Terminals 1 & 2)
Wire MOV
(supplied)
directly to strike
Aura
Dip Switch
Settings
1REM/LOC
RELAY
SPEAKER
2
3
Enable
ON
1RED
GREEN
BLUE
RED
GREEN
BLUE
2
3
Active Color
ON
1
2
3
Idle Color
ON
= Switch Position
CX-WC13FM & WEC10 Single Door Restroom (Normally unlocked)
CAMDEN DOOR CONTROLS
SCALE: NONE
DRAWING No: DRG-CX-WC-13-7 FILE NAME: WC-13FM-7-WEC10 wiring diagram_R2
DRAWN BY: DGW DATE: 03/08/17 REV: 2
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
Important:
Ensure wiring polarity is consistent
from Relay 3 to each Aura Remote
Input terminals

Page 16 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
PUSH
TO OPEN
PUSH
TO LOCK
N.C.
Door Operative
Remote
+
-
Part# 40-82D003
-V+V
1
2
3
4
PUSH
TO OPEN
LED 1
CX-33
LED 2
LED 3
DISPLAY
Relay 1 Relay 2 Relay 3
N/C
N/C
N/O
N/O
N/O
N/C
COM
COM
COM
POWER
12/24V
AC/DC
DRY 1
DRY 2
DRY 3
DRY 4
+ WET
INPUT
INPUT
INPUT
INPUT
- INPUT
MENU UP DOWN
0.0.8
12-24 VDC
Power for
Strike
Magnetic
Contact
Switch
Contact closed
when door is
closed
12/24V
Power
N.O.
Relay
Output
Remote
12/24V
Power
N.O.
Relay
Output
Inside
Wall Switch
(always unlocks
and opens door)
Outside Wall Switch
CM-45/455SE1 (or similar)
Inside PUSH TO LOCK
CM-45/855SE1 (or similar)
CM-450R/12
CM-AF501SO
CM-AF141SO
+24 VDC Power
Supply
GRY
BLK
N/O N/C
BLK
MOV
GRY
3
4
12 - 24 V
AC/DC
Power
Note:
This Drawing should be used in addition
to each products respective Installation
Manual (not in place of).
Note:
To unlock the door
in this mode an additional
NO contact block is required.
Camden Part# CM-4000/60N
Important:
Ensure wiring polarity is consistent
from Relay 3 to each Aura Remote
Input terminals
Fail-Secure Electric
Strike Shown
(If Fail-Safe lock is
used, wire to Terminals
NC & COM)
Wire MOV
(supplied)
directly to strike
Aura
Dip Switch
Settings
1REM/LOC
RELAY
SPEAKER
2
3
Enable
ON
1RED
GREEN
BLUE
RED
GREEN
BLUE
2
3
Active Color
ON
1
2
3
Idle Color
ON
= Switch Position
CX-WC13FM & WEC10 Single Door Restroom (Normally locked)
CAMDEN DOOR CONTROLS
SCALE: NONE
DRAWING No: DRG-CX-WC-13-8 FILE NAME: WC-13FM-8-WEC10 wiring diagram_R2
DRAWN BY: DGW DATE: 03/08/17 REV: 2
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7

Page 17 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
PUSH
TO OPEN
N.C.
Door Operator
Remote
+
-
Part# 40-82D018
-V+V
1
2
3
4
LED 1
CX-33
LED 2
LED 3
DISPLAY
Relay 1 Relay 2 Relay 3
N/C
N/C
N/O
N/O
N/O
N/C
COM
COM
COM
POWER
12/24V
AC/DC
DRY 1
DRY 2
DRY 3
DRY 4
+ WET
INPUT
INPUT
INPUT
INPUT
- INPUT
MENU UP DOWN
0.0.7
12-24 VDC
Power for
Strike
Magnetic
Contact
Switch
Contact closed
when door is closed
12/24V
Power
N.O.
Relay
Output
Outside Wall Switch
CM-45/455SE1 (or similar)
CM-AF540SO
CM-AF141SO
+24 VDC Power
Supply
GRY
BLK
N/O N/C
BLK
MOV
GRY
CM-2520/4855SE1 (or similar)
PUSH
TO
OPEN
PUSH
TO
LOCK
Inside
‘Push To Open (always unlocks & opens door)
& Push to Lock’ combination Switch
12 - 24 V
AC/DC
Power
12/ 24
Power
Remote
N.O.
Relay
Output
Push To
Open
Note:
This Drawing should be used in addition
to each products respective Installation
Manual (not in place of).
Important:
Ensure wiring polarity is consistent
from Relay 3 to each Aura Remote
Input terminals
Fail-Safe Electric
Strike Shown
(If Fail-Secure lock is
used, wire to Terminals
NC & COM)
Wire MOV
(supplied)
directly to strike
CX-WC13AXFM/SM & WEC10K2 Single Door Restroom (Normally unlocked)
CAMDEN DOOR CONTROLS
SCALE: NONE
DRAWING No: CX-WC13AXFM-WEC10-7
FILE NAME: WC-13AXFM-7-WEC10K2 wiring diagram_R1
DRAWN BY: JML DATE: 05-22-2018 REV: 2
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
Aura
Dip Switch
Settings
1REM/LOC
RELAY
SPEAKER
2
3
Enable
ON
1RED
GREEN
BLUE
RED
GREEN
BLUE
2
3
Active Color
ON
1
2
3
Idle Color
ON
= Switch Position

Page 18 of 18
WC13 SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
PUSH
TO OPEN
N.C.
Door Operator
Remote
+
-
Part# 40-82D018
-V+V
1
2
3
4
LED 1
CX-33
LED 2
LED 3
DISPLAY
Relay 1 Relay 2 Relay 3
N/C
N/C
N/O
N/O
N/O
N/C
COM
COM
COM
POWER
12/24V
AC/DC
DRY 1
DRY 2
DRY 3
DRY 4
+ WET
INPUT
INPUT
INPUT
INPUT
- INPUT
MENU UP DOWN
0.0.8
12-24 VDC
Power for
Strike
Magnetic
Contact
Switch
Contact closed
when door is closed
12/24V
Power
N.O.
Relay
Output
Outside Wall Switch
CM-45/455SE1 (or similar)
CM-AF540SO
CM-AF141SO
+24 VDC Power
Supply
GRY
BLK
N/O N/C
BLK
MOV
GRY
CM-2520/4855SE1 (or similar)
PUSH
TO
OPEN
PUSH
TO
LOCK
Inside
‘Push To Open (always unlocks & opens door)
& Push to Lock’ combination Switch
12 - 24 V
AC/DC
Power
Fail-Secure Electric
Strike Shown
(If Fail-Safe lock is
used, wire to Terminals
NC & COM)
Wire MOV
(supplied)
directly to strike
Note:
This Drawing should be used in addition
to each products respective Installation
Manual (not in place of).
Important:
Ensure wiring polarity is consistent
from Relay 3 to each Aura Remote
Input terminals
12/ 24
Power
Remote
N.O.
Relay
Output
Push To
Open
CX-WC13AXFM/SM & WEC10K2 Single Door Restroom (Normally locked)
CAMDEN DOOR CONTROLS
SCALE: NONE
DRAWING No: CX-WC13AXFM-WEC10-8
FILE NAME: WC-13AXFM-8-WEC10K2 wiring diagram_R1
DRAWN BY: JML DATE: 05-22-2018 REV: 2
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7
Aura
Dip Switch
Settings
1REM/LOC
RELAY
SPEAKER
2
3
Enable
ON
1RED
GREEN
BLUE
RED
GREEN
BLUE
2
3
Active Color
ON
1
2
3
Idle Color
ON
= Switch Position
This manual suits for next models
5
Other CAMDEN Controllers manuals
Popular Controllers manuals by other brands

CKD
CKD FLCR-G Series instruction manual

Kutai electronics
Kutai electronics ADVR-054 Operation manual

AC Infinity
AC Infinity AC-CRA5 user manual

Allen-Bradley
Allen-Bradley GuardLogix user manual

Honeywell
Honeywell Pro-Watch 7000 install guide

Emerson
Emerson Dixell XR20T Installing and operating instructions

Rain Bird
Rain Bird RC2-230V user manual

Cooper
Cooper McGraw-Edison VR-32 Installation, operation and maintenance instructions

Flowserve
Flowserve Valtek Mark Safety guide

Eliwell
Eliwell FREE Panel EVP 3300/C installation manual

Lenovo
Lenovo ServeRAID H1110 Product guide

AirCom
AirCom R364-S operating manual