WC16PS Series Restroom Control
INSTALLATION INSTRUCTIONS
Electrified Locks, Relays and Timers
1. GENERAL DESCRIPTION
The Restroom Control Kit allows access in and out of a Restroom,
with the ability to secure the door and make patrons aware that
the location is either occupied or vacant while using Camden’s
hands-free SURE-WAVE touchless switches.
The CX-WC16PS Series of Restroom Control Kits are controlled by
Camden’s advanced relay logic controller part number CX-33. The
CX-33 currently has 2 pre-set modes that will accommodate most
Restroom applications, Mode 7 (normally unlocked) or Mode
8 (normally locked). The default Mode for the CX-WC16PS
is Mode 7 (normally unlocked). Each Restroom Control Kit
will have the ability to physically open the door then allow the
patron to lock the door once inside. When locked, the CX-33 will
change the coloring of the inside & outside SURE-WAVE touchless
switches (with the SGLR light ring option) from green to red,
displaying that the Restroom is in use. When the inside WAVE TO
OPEN switch is activated it will unlock the door, then physically
open the door and change the color of the inside & outside
WAVE TO OPEN touchless switches SGLR light ring back to green,
displaying that the Restroom is now vacant. The locked Restroom
can be unlocked by either activating the inside WAVE TO OPEN
touchless switch, or by using the crash bar, paddle or turning the
knob set to open the door. Either method will reset the SGLR light
ring back to green.
The CX-WC16PS Series of Restroom Control Kits kit uses
Camden’s CM-331/42WS-SGLR as the outside WAVE TO OPEN,
the CM-325/42WS as the inside WAVE TO OPEN and the
CM-331/43S-SGLR as the WAVE TO LOCK. The SGLR circuit board
is installed on the front of the outside WAVE TO OPEN and on
the front of the inside WAVE TO LOCK touchless switches making
them easily seen by patrons at a distance.
2. INSTALLATION
Operation at a Glance
When the outside WAVE TO OPEN touchless switch is activated
it will trigger its N.O. relay contact to send a momentary closure
to the CX-WC16PS allowing the door to swing open.
When the interior WAVE TO LOCK touchless switch is activated it
will trigger its N.O. relay contact to send a momentary closure to
the CX-WC16PS to lock the Restroom and switch the SGLR light
ring color from green to red. The inside WAVE TO OPEN. When
activated will unlock the door, and the door will swing open.
The Restroom can also be unlocked by opening the door from
the inside which will break the door contact circuit causing the
CX-WC16PS to reset and unlock the door. The SGLR light ring
will switch back to green signalling the Restroom is
now vacant.
Mounting
IMPORTANT: Do not apply power to the unit until you
have fully read the instructions and have made the
required adjustments.
The CX-WC16PS cabinet should be mounted in a clean dry
location out of direct contact with the elements.
Wiring the CX-WC16PS Series Restroom
Control Kit is as follows:
The CX-WC16PS comes with the CX-33 pre-wired to a labeled set
of two terminal strips. This will make the wiring of the WAVE TO
OPEN/WAVE TO LOCK sensors easier since the wiring manual
will no longer need to be directly referenced for termination
points. A complete wiring diagram is adhered to the inside of
the door to provide a layout of the wiring as a reference when
wiring the eld devices to the kit.
There are two terminal strips that mirror the locations on the
CX-33. The left strip is used for power to the CX-33, the PUSH
TO OPEN (WAVE TO OPEN) and PUSH TO LOCK (WAVE TO LOCK)
sensors, the door position switch, and the Wet trigger. The
right strip is for the outputs to drive the strike (Relay 1), door
operator (Relay 2), SGLR light ring (Relay3), and to provide VDC
power for the door strike.
All SURE-WAVE devices can be powered with 12/24 VAC/VDC.
Note: The SGLR option (light ring) must be installed before
applying power to the sensor.

Page 2 of 13
WC16PS SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
Wiring the Outside WAVE TO OPEN Sensor
(CM-331/42WS-SGLR)
Wire in power to the TB1 terminal block on the back lower left
side (not polarity sensitive). On terminal block TB3, wire the
common and normally open poles of the relay to Dry1 & Input
on the CX-33. The Remote terminal (TB2) will be wired in parallel
with the Remote terminal (TB2) of the Inside WAVE TO LOCK.
Then it’s wired to Relay 3 (common & normally open) of the
CX-33. Install the SGLR (light ring) circuit board on the front-face
of the Outside WAVE TO OPEN sensor.
Conrm the DIP switch settings using the legend below. Adjust
the range accordingly with POT1 and POT 2 for the desired
activation time.
Wiring the Inside WAVE TO OPEN Sensor
(CM-325/42WS)
Wire in power using the two red wires (not polarity sensitive).
Next, connect the Blue wire (normally open) and the green wire
(common) to Dry2 & Input on the CX-33.
The range and the activation time can be adjusted from the
front-face of the sensor. The range adjustment is on the top and
the activation time is located on the bottom.
Wiring the Inside WAVE TO LOCK Sensor
(CM-331/43WS)
Wire in power to the TB1 terminal block on the back lower left
side (not polarity sensitive).
On terminal block TB3, wire the common and normally open
poles of the relay to Dry3 & Input on the CX-33.
The Remote terminal (TB2) will be wired in parallel with the
Remote terminal (TB2) of the Outside WAVE TO OPEN. Then it’s
wired to Relay 3 (common & normally open) of the CX-33.
Install the SGLR (light ring) circuit board on the front-face of the
Inside WAVE TO LOCK sensor.
Conrm the DIP switch settings using the legend below. Adjust
the range accordingly with POT1 and POT2 for the desired
activation time.
Once all eld devices are wired to the CX-WC16PS then AC
power can be wired in.
IMPORTANT: Do not apply power to the unit until you
have fully read the instructions and have made the
required adjustments.
The supplied CX-TRX-5024 transformer will have its secondary
terminals wired to the terminals on the top of the left terminal
strip marked as “AC”.
Next, wire the primary terminals to the AC feed to be used.
Conrm your connections and apply power by turning on the
electrical panels breaker.
Selecting a Mode
The CX-WC16PS has two Restroom applications built in (Mode 7
& 8). The default mode for the CX-WC16PS is Mode 7
(normally unlocked).
Determining which mode is correct for you will be based on
whether the Restroom will be normally unlocked (Mode 7) or
normally locked (Mode 8).
There are three LED displays that will allow you to see what mode
you have selected when advancing through the modes.
To change the mode of the CX-WC16PS, simply press the
MENU button once and use the UP button to advance to the
desired mode.
Editing the Settings for a Mode
Camden builds in typical times for lock release and door
operator activation and is ready to use without changing any
parameters. If you need to change the timing or delay for an
output, it can be done by pressing the “MENU” button within the
mode you selected.
Once the option is selected you can use the “UP or DOWN”
buttons to select the timing needed. The rst option
(H & 1 ashing) will be how long relay 1 will be activated for
(0-50 seconds).
The second option (d & 1 ashing) will be how long to wait
before activating relay 2 (0-15 seconds).
The third option (H & 2 ashing) will be how long relay 2 will be
activated for (0-50 seconds).
The fourth option (d & 2 ashing) will be how long to wait before
activating relay 3 (0-15 seconds).
The fth option (H & 3 ashing) will be how long relay 3 will be
activated for (0-50 seconds). See chart below.
Factory Reset (Defaulting the CX-33)
To return the CX-33 back to its factory default settings you will
need to remove power, then hold down the “MENU” button
while powering up the CX-33.
Once started you will see the rmware version listed then a
number “1” will be displayed. Reconnect your power and press
the “MENU” button once then use the “UP” or “DOWN” button to
advance to the desired mode.
Fully test the operation of the CX-WC16PS for proper
functionality.

Page 3 of 13
WC16PS SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
Display (M) Description ( Mode you are in) Parameters (1-15 )
H, then 1 Relay 1 Hold Time 0.0 to 50 seconds
d, then 1 Relay 2 Delay Time 0.0 to 15 seconds
H, then 2 Relay 2 Hold Time 0.0 to 50 seconds
d, then 2 Relay 3 Delay Time Depends on Mode
H, then 3 Relay 3 Hold Time 0.0 to 50 seconds
dSets the display ON or OFF during operating mode ON or OFF
AInput delay on Activate. If other than 0.0 is selected, the input must
be held in for the time period chosen before the CX-33 will activate. 0.0 to 10 seconds
1Set Dry Input 1 to activate on normally open or normally closed contact. N/O OR N/C
2Set Dry Input 2 to activate on normally open or normally closed contact. N/O OR N/C
3Set Dry Input 3 to activate on normally open or normally closed contact. N/O OR N/C
4Set Dry Input 4 to activate on normally open or normally closed contact. N/O OR N/C
5Set Wet Input 5 to activate on normally open or normally closed contact. N/O OR N/C
Mounting
The Sure-Wave™ may be mounted in single or double gang electrical boxes, and 4 x 4 boxes.
NOTE: The sealing gasket (included) is recommended for outdoor or wet locations.
If using with Automatic doors install in accordance with ANSI A156.10 / A156.19.
Select from one of the following mounting subsections :

Page 4 of 13
WC16PS SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
SINGLE GANG ELECTRICAL BOX MOUNT - CM-331/43S-SGLR
1. a) If using an in-wall box ensure the box is plumb and
square, and ush with the wall surface. (See Diagram 1)
b) If using a surface box, ensure it is secure & plumb.
2. Bring your 4 or 6-conductor wire through the back or side
of the enclosure and leave approximately 6” tail for
wiring connection.
3. Make the electrical connections to the device according to
the wiring section.
4. Using the dip switch located on the end of the unit, set the
operating mode.
5. Attach the unit to the enclosure using the two #6-32
screws provided.
6. Apply power and adjust range and time delay via the
potentiometers on the front of the unit.
7. Attach the faceplate to the unit using the two black
#6-32 x 1/2’’ machine screws or tamperproof screws.
NOTE: Do not overtighten!
8. Apply the label as required.
Wall Wall
CM-331/42S-SGLR Label CM-331/42SW-SGLR Label
CM-331/42S-SGLR Label
CM-331/43S-SGLR Surface Mount CM-331/43S-SGLR Flush Mount

Page 5 of 13
WC16PS SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
DOUBLE GANG ELECTRICAL BOX MOUNT - CM-331/42SW-SGLR - CM-325/42SW
5502 Timberlea Blvd.
Mississauga, ON Canada L4W 2T7
Tel: (905) 366-3377
www.camdencontrols.com
A.OLISA MAR-20 Double Gang Surewave
mounting Exploded
CM-331/42S-SGLR Label
CM-331/42SW-SGLR
CM-325/42SW Faceplate
Note:
CM-325/42SW Does not
come with a Label Wall
Adapter Plate
CM-331/42SW-SGLR & CM-325/42SW Flush Mount
1. a) If using an in-wall box ensure the box is plumb and
square, and ush with the wall surface.
b) If using a surface box, ensure it is secure & plumb.
c) If using a 4 x 4 box, ensure the box is plumb and square,
and ush with the wall surface, then attach the metal
adaptor plate (included in the packages) to the box using
appropriate fasteners.
2. Bring your 4 or 6-conductor wire through the back or side
of the enclosure and leave approximately 6” tail for
wiring connection.
3. Make the electrical connections to the device according
to the wiring section.
4. Using the dip switch located on the end of the unit, set the
operating mode.
5. Attach the unit to the enclosure using the two #6-32
screws provided.
6. Apply power and adjust range and time delay via the
potentiometers on the front of the unit.
7. Attach the faceplate to the unit using the two black
#6-32 x 1/2’’ machine screws or tamperproof screws.
NOTE: Do not overtighten!
8. Apply the label as required
(only for the CM-331/42SW-SGLR).

Page 6 of 13
WC16PS SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
IN-WALL MOUNTING
SUREWAVE ASSEMBLY
5502 Timberlea Blvd.
Mississauga, ON Canada L4W 2T7
Tel: (905) 366-3377
www.camdencontrols.com
Surewave Exploded
assembly
CM-331/42SW-SGLR
CM-325/42SW Sealing Gasket
Surface Mount Enclosure
#6-32 x 3/4” (2 Pcs)
#6-32 x 1/2”
(2 Pcs)
Polypropylene
Lens Holder Set
CM-331/43S
Sealing Gasket
IR Lens
CM-331/43S Faceplate
CM-331/42SW-SGLR
CM-325/42SW Faceplate
Flush
Smooth Wall Finish
Proper Mounting Improper Mounting
Wall
In-Wall Box
Sure-Wave™
Rough Finished Wall
Recessed Box Unaligned Box
5502 Timberlea Blvd.
Mississauga, ON Canada L4W 2T7
Tel: (905) 366-3377
www.camdencontrols.com
A.OLISA MAR-20 SureWave In-Wall
Mounting Drawing.

Page 7 of 13
WC16PS SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
CX-ED2079 'UNIVERSAL' ELECTRIC STRIKE INSTALLATION
CX-ED2079 ‘Universal’ Electric Strike
1. Prepare the door jamb as per the appropriate drawing.
2. Install mounting brackets to jamb using M5x12 screws
and pressed metal nuts. Do not tighten.
3. Spacers are used to assure ush nal assembly of
faceplate into jamb. Add one of more spacers between
jamb and mounting bracket when face plate extends
beyond the jamb. When the faceplate sits inside the
jamb, spacers must be added between the mounting
bracket & the lip bracket. Make sure clearance hole in
spacer aligns with hole in mounting bracket.
4. Connect wires coming from the low voltage side of the
transformer to wires (black) from strike.
5. Install electric strike jamb by attaching with # 10-32
screws and lockwashers.
6. Secure M5x12 screws holding mounting brackets to jamb.
4. Installation
Mounting Bracket
Spacer
Spacer (Option)
Spacer
M5x12 Flat-Head Screw (2pcs)
Jamp
M5x12 Screw
Vertical Centerline
Note: The products are intended to be installed in accordance
with the installation wiring diagram, mechanical assembly
drawings provided with each product, the local authority having
jurisdiction (AHJ) and the National Electric Code, NFPA 70.
When installed in fail secure mode, the local authority shall be
consulted with regard to the use of possible panic hardware to
allow emergency exit from the secure area.
The electric door strike shall be installed in such a way and
in such a location so as to not impair the operation of an
emergency exit device or panic hardware mounted on the door.
(86mm)
3-3/8”
(187mm)
7-3/8”
(36mm)
1-3/8”
(200mm)
7-7/8”
(86mm)
3-3/8”
(86mm)
3-3/8”
(168mm)
6-3/8”
(31mm)
1-7/32”
(31mm)
1-7/32”
(31mm)
1-7/32”
(105mm)
ESP1B + ESP2B
ESP3B
ESP4B
4-1/8”
(124mm)
4-7/8”
(89mm)
3-1/2”
(155mm)
6-1/8”
(173mm)
6-7/8”
(144mm)
5-11/16”

Page 8 of 13
WC16PS SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
CONNECTIONS OPERATIONS
CX-ED2079 ‘Universal’ Electric Strike
Red
Black
Blue
Green
Black
Red
Blue
Green
Black
Red
Blue
Green
(+12V)
( - )
(+24V)
( - )
12V
24V
Varistor
Varistor
Power
Power
5. Connections 6. Operation
POWER
12VDC
Red/Black: +12V
Blue/Green: Ground
A varistor is provided to protect/prevent strike from spikes.
Connect varistor between input wires.
Fail Safe Changing
Fail Secure
24VDC
Red: +24V
Black/Blue: -
Green: Ground
How to modify fail-safe to fail-secure or vice versa.
1. Loosen the screw as per the product diagram below.
2. Rotate the set plate 180° and slide the plate until it
is properly seated.
3. Tighten the screw.
Note: For UL 294 / UL 1034 compliance the door strikes
are to be powered via a UL 294/ UL 603 class 2 power
limited output from a control panel and or power supply.
Furthermore, when powered by AC/DC the units shall use a
UL regulated UL 294/ UL 603 power limited class 2 output
rated 12/24V with AC on indicator.

Page 9 of 13
WC16PS SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
Item Part Number Description
1
60-31A008 Line Powered Surewave, 1 Relay for CM-331/43S-SGLR & CM-331/42SW-SGLR
60-31A006 Touchless IR Sensor Short Range for CM-325/42SW
260-40E035 Advanced Logic Control Relay and 2 Amp Power Supply in pre-wired metal cabinet
3CX-MDA Magnetic Door Contact
460-81C024 English Self-Adhesive Vinyl Sign ‘’WAIT FOR DOOR TO CLOSE’’
CM-331/43S-SGLR Single Gang SureWave Label
560-81C010 Decal Print English Label ‘’LOCKED WHEN RED/UNLOCKED WHEN GREEN’’
660-81C010F Decal Print French Label ‘’PORTE BARRÉE/PORTE DÉBARRÉE’’
760-81C010FE Decal Print English & French Sign ‘’WAIT FOR DOOR TO CLOSE’’
860-81C011 Decal Print English Sign ‘’OCCUPIED WHEN RED VACANT WHEN GREEN’’
Single Gang SureWave Enclosure
9CM-34BL Single Gang Black ABS Box, Surface Mount
2-7/8’’ W x 4-5/8’’H x 1-3/4’’D (73mm x 117mm x 44mm)
10 CM-34AL Single Gang Aluminum Box, Surface mount
2-7/8’’W x 4-5/8’’H x 2’’D (73mm x 117mm x 51mm)
11 CM-34D Single Gang, Extra Deep heavy-duty grey polymer
2-3/4’’W x 4-1/2’’H x 3’’D (70mm x 114mm x 76mm)
CM-331/42SW-SGLR Double Gang SureWave Label
12 60-81C012 Decal Print English Label ‘’OCCUPIED WHEN RED/VACANT WHEN GREEN’’
13 60-81C012F Decal Print French Label ‘’PORTE BARRÉE/PORTE DÉBARRÉE’’
14 60-81C012FE
Decal Print English & French Label
‘’OCCUPÉ QUAND ROUGE LIBRE QUAND VERT’’ &
‘’OCCUPIED WHEN RED VACANT WHEN GREEN’’
ORDERING INFORMATION FOR REPLACEMENT PARTS

Call: 1.877.226.3369 / 905.366.3377
Visit: www.camdencontrols.com
Opening New Doors to
Innovation, Quality and Support!
WC16PS SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
Page 10 of 13
File: WC16PS Restroom Controls
Manual.indd
Rev.: September 13, 2023
Part No: 40-82B239
Questions? Call us toll-free at 1-877-226-3369 or technical support 905-366-3377 (ext. 505)
Notes :
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.

Page 11 of 13
WC16PS SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
RESTROOM SIGNAGE
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
CAMDEN DOOR CONTROLS. ANY
REPRODUCTION IN PART OR AS A
WHOLE WITHOUT THE WRITTEN
PERMISSION OF CAMDEN DOOR
CONTROLS IS PROHIBITED.
5502 Timberlea Blvd.
Mississauga, ON Canada L4W 2T7
Tel: (905) 366-3377
www.camdencontrols.com
A.OLISA 24/01/20
Place Sign
On The Door
Inside The Restroom
At Eye Level
INSIDE THE
RESTROOM
Indicator on switch will turn red when door is locked.
USE ''WAVE TO LOCK'' SWITCH
TO LOCK THIS DOOR
WAIT FOR DOOR TO CLOSE
40-81C024
LOCKED WHEN RED
UNLOCKED WHEN GREEN
WAVE TO OPEN
WAVE
TO LOCK
40-81C024 Door
sign for cx-wc16

Page 12 of 13
WC16PS SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
CX-WC16FM-PS Wiring Diagram with CX-WEC10-K2 Integration
FILENAME:
DRAWING No:
SCALE: NONE DRAWN BY: REV:DATE:
CAMDEN DOOR CONTROLS
5502 Timberlea Blvd
Mississauga, Ontario
L4W 2T7
JML Jan 20, 2020 1
CX-WC16FM-PS & CX-WEC10-K2 Wiring Diagram
Door Position Switch
Transformer
CX-TRX-5024
24 VAC, 50 VA
CM-331/42WS-SGLR
Outside
Wall Switch
CM-325/42WS
Inside - Wall Switch
(always unlocks/opens door)
CM-331/43S-SGLR
Inside - Wave to Lock
CX-WEC10-K2
Emergency Call System Wiring
Electric Strike
CX-ED2079
Wire MOV
directly to
strike or
magnet
Connect directly to DPS if no Emergency Call System is installed
Door Operator
120 VAC
N.C.
AC
AC
Outside
Push To Open
Inside
Push To Open
Push To
Lock
DPS NC
DPS COMM
+ WET
-INPUT
*
+ Strike
-Strike
*
Door
Operator
*
LED
Control
*
+ VDC
-VDC
1
2
3
4
CM-AF540SO
CM-AF141SO
GRY
BLK
N/O N/C
BLK
GRY
Model: 60-40E035
WAVE
TO LOCK
12/24V
Power
Remote N.O.
Relay Output
WAVE TO OPEN
12/24V
Power
Remote N.O.
Relay Output
TB1 TB2 TB3 TB1 TB2 TB3
5 6 5 6
WAVE TO OPEN
RED
RED
BLUE
GREEN
POWERRELAY O/P
Surewave
Dip Switch
Settings
Notes
1. CX-33 can be set to Mode 7 (Normally Unlocked)
or Mode 8 (Normally Locked).
2. Mode 7 = Set Set Strike to Fail Safe.
3. Mode 8 = Set Strike to Fail Secure.
1LED
Audio
Fail Safe
EXT
2
3
4
Enable (DIP 1)
ON
1IDL = GREEN
ACT = RED
2
3
4
Mode (DIP 2)
ON
1
2
3
4
Color (DIP 3)
ON
= Switch Position
IMPORTANT:
Ensure wiring polarity is consistent from Relay 3
to each Aura Remote Input terminals
MOV

Page 13 of 13
WC16PS SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
CABINET BASE
L
C
L
C
7-7/8” (200.2 mm)
Cabinet Base Mounting Template
6” (152.7 mm)
6” (152.7 mm)
9-5/8”
(243.9 mm)
11-1/16”
(281.4 mm)
This manual suits for next models
3
Table of contents
Other CAMDEN Controllers manuals
Popular Controllers manuals by other brands

CKD
CKD FLCR-G Series instruction manual

Kutai electronics
Kutai electronics ADVR-054 Operation manual

AC Infinity
AC Infinity AC-CRA5 user manual

Allen-Bradley
Allen-Bradley GuardLogix user manual

Honeywell
Honeywell Pro-Watch 7000 install guide

Emerson
Emerson Dixell XR20T Installing and operating instructions

Rain Bird
Rain Bird RC2-230V user manual

Cooper
Cooper McGraw-Edison VR-32 Installation, operation and maintenance instructions

Flowserve
Flowserve Valtek Mark Safety guide

Eliwell
Eliwell FREE Panel EVP 3300/C installation manual

Lenovo
Lenovo ServeRAID H1110 Product guide

AirCom
AirCom R364-S operating manual