14
Operating Instructions
Programmable
isolating amplifier
SINEAX TV 809
TV 809 Be 147 802 08.04
Camille Bauer Ltd
Aargauerstrasse 7
CH-5610 Wohlen/Switzerland
Phone +41 56 618 21 11
Fax +41 56 618 24 58
e-mail: [email protected]
http://www.camillebauer.com
The following symbols in the
Operating Instructions indicate safety
precautions which must be strictly
observed:
2. Scope of supply (Fig. 1 and 2)
Isolating amplifier, one of the two versions (1)
Order Code: Significance of the 1st to 7th digits
809 – x x x
3Housing with screw terminals,
not pluggable
9Housing with screw terminals, pluggable
1Standard / Power supply 24 … 60 V DC, AC
2Standard / Power supply 85 … 230 V DC, AC
3[EEx ia] IIC / Power supply 24 … 60 V DC, AC
4 [EEx ia] IIC / Power supply 85 … 110 V DC / 230 V AC
1Input current max. final value 100 mA (Standard)
2Input current max. final value 1.5 mA
Contents
1. Read first and then … ................................................................... 1
2. Scope of supply ............................................................................ 1
3. Brief description ............................................................................ 1
4. Overview of the parts .................................................................... 2
5. Technical data ............................................................................... 2
6. Mounting ....................................................................................... 2
7. Electrical connections ................................................................... 2
8. Configuring the isolating amplifier ................................................ 3
9. Accessories and spare parts ........................................................ 4
10. Commissioning ............................................................................. 4
11. Maintenance ................................................................................. 4
12. Releasing the isolating amplifier ................................................... 4
13. Dimensional drawings ................................................................... 4
1. Read first and then …
The proper and safe operation of the device assumes
that the Operating Instructions are read and the safety
warnings given in the various Sections
6. Mounting
7. Electrical connections
8. Configuring the isolating amplifier
10. Commissioning
are observed.
The device should only be handled by appropriately
trained personnel who are familiar with it and authorised
to work in electrical installations.
Unauthorized repair or alteration of the unit invalidates
the warranty.
Fig. 1
1Operating Instructions (2) each in German, French and English
1 Ex approval (3), only for Ex version devices
3. Brief description
The purpose of the isolating amplifier SINEAX TV 809 is to electrically
insulate input and output signals, respectively to amplify and/or change
the signal level or type (current or voltage) of the input signals.
An explosion-proof “intrinsically safe” [EEx ia] IIC version rounds off this
series of SINEAX TV 809.
Measured variables and measuring ranges are programmed with the aid
of a PC, a programming cable and the programming software. Specific
measured variable data such as output signal, transmission characteristics
and various functions in combination with the alarm function can also be
programmed.
Isolating amplifier supplied as standard versions are configured as
follows:
–Measuring input: 4 … 20 mA
–Measuring output: 4 … 20 mA
–Response time: 80 ms
–Mains ripple suppression: For frequency 50 Hz
(1)
809 – x x x x x
(2)
0Without alarm function
1With built-in alarm relay
0Without test records
DWith test records in German
EWith test records in English
13. Dimensional drawings
Fig. 8. SINEAX TV 809 in carrying rail housing P12/17 clipped onto a top-hat rail
(35 ×15 mm or 35 ×7.5 mm, acc. to EN 50 022), screw terminals not pluggable.
63
69.2
17.5 114
Fig. 9. SINEAX TV 809 in carrying rail housing P12/17 St clipped onto a top-hat rail
(35 ×15 mm or 35 ×7.5 mm, acc. to EN 50 022), screw terminals pluggable.
63
85
17.5 114
10. Commissioning
Switch on the measuring input and the power supply.
The power supply unit must be capable of supplying a
brief current surge when switching on. The isolating
amplifier presents a low impedance at the instant of
switching which requires a current Istart of …
…I
start ≥160 mA for the version with a power supply range
of 24 – 60 V DC, AC
or
…I
start ≥35 mA for the version with a power supply range
of 85 – 230 V DC, AC
11. Maintenance
No maintenance is required.
12. Releasing the isolating amplifier
Release the instrument from a top-hat rail as shown in Fig. 7.
Fig. 7


























1. The programming connector must not be
connected when > 253 V could be applied to the
SINEAX TV 809 input circuit.
2. The SINEAX TV 809 programming connector must
only be used with the PRKAB 600 resp. 560 and its
ancillary cable.
3. The ancillary cable must first be connected to the
PRKAB 600 resp. 560 before it is connected to the
TV 809 (see arrow).
4. The programming connector is galvanically
connected to the input circuit. Therefore no metal
parts of the plug or socket may be touched.
5. The PRKAB 600 resp. 560 must not be used with
other devices.
6. After programming is complete, the programming
connection must be removed from the TV 809.
Interfaceto PC
DSUB 9p F
to
SINEAX TV 809
Ancillary cableProgramming cable PRKAB 600 resp. 560
FCC
DSUB 9p F
Interface
1 meter
Programming cable PRKAB 560
(for programming the SINEAX TV 809 non-Ex
Ancillary cable SINEAX type TV 809
143 587
1.5 meter
146 557
147 779
9. Accessories and spare parts
Description Order No.
(3)
Configuration software TV 800 plus
for SINEAX TV 809
Windows 95 or higher
on CD, in different languages
(Download free of charge under
http://www.camillebauer.com)
In addition, the CD contains all configuration
programmes presently available for Camille
Bauer products
Operating Instructions TV 809 Bd 147 422
in German
Operating Instructions TV 809 Bf 147 795
in French
Operating Instructions TV 809 Be 147 802
in English
Fig. 2
DSUB 9p F
Interface
1 meter
Programming cable PRKAB 600
(for programming the SINEAX TV 809 Ex
147 787
32
4. Overview of the parts
Figure 3 shows those parts of the device of consequence for electrical
connections and other operations described in the Operating Instructions.
Fig. 3
(4) Top-hat rail 35 ×15 mm or 35 ×7.5 mm (EN 50 022)
(5) Type label
(6) Terminals
ON Green LED to indicate the operating state and limit exceeded. The LED
flashes (option)
(7) Programming connector
5. Technical data
Measuring input
Input variable and measuring range configured
DC current: Type 809 – xx1
Start value/final value between
– 100 and 100 mA, Ri= 15.4 Ω
Any point may be zero
Type 809 – xx2
Start value/final value between
– 1.5 and 1.5 mA, Ri= 1 kΩ
Any point may be zero
DC voltage: EEx version max. 30 V
≤±1.7 V, Ri= 1 MΩ
> ±1.7 to ≤±100 V, Ri= 540 kΩ
> ±100 to ±1000 V, Ri= 5.5 MΩ
Reduced safety
Measuring output
DC current*: Programmable,
reference range – 20 … 20 mA,
start and final values anywhere within the
reference range, also with reversed direction
e.g. 20 … 4 mA
External resistance: Rext max. ≤600 Ωwith 20 mA output
DC voltage*: Programmable,
reference range – 10 … 10 V,
start and final values anywhere within the
reference range, also with reversed direction
e.g. + 10 … – 5 V
Load capacity: Rext min. ≥1000 Ωwith 10 V output
Programming connector on isolating amplifier
Interface: Serial interface
Power supply
DC, AC power pack (DC or 45…400 Hz)
Rated voltages and permissible variations
Nominal voltage UNTolerance Instruments version
24… 60 V DC, AC
85…230 V** DC, AC
DC – 15…+ 33%
AC ±15%
85…230 V AC ±10%
85…110 V DC – 15…+ 10%
Power consumption: ≤1.2 W resp. ≤2.5 VA
DC – 15…+ 33%
AC ±15%
7. Electrical connections
The connections for the leads are fixed or plug-in screw terminals,
depending on the device execution. These are easily accessible at the
front of the isolating amplifier and are suitable for a wire cross-section of
max. 2.5 mm2.
When deciding where to install the isolating amplifier
(measuring location), take care that the limits of the
operating temperature are kept:
–25 and + 55 °C
Simply clip the device onto the top-hat rail (EN 50 022) (see Fig. 5).
Make sure that the cables are not live when making the
connections!
Impending danger by high input voltage or high
power supply voltage, 250 V at contact output.
6. Mounting
The SINEAX TV 809 can be mounted on a top-hat rail.
Fig. 5. Mounting onto top-hat rail 35 ×15 or 35 ×7.5 mm.


























Also note that, …
…the data required to carry out the prescribed measurement must correspond to those marked on the nameplate of SINEAX TV 809
(measuring input, measuring output and power supply)!
…the resistance in the output circuit may not overrange the current output value
12 V
IAN [mA]
(IAN = current output value)
and not underrange the voltage output value
UAN [V]
10 mA
(UAN = voltage output value)
… the measurement input and output cables should be twisted pairs and run as far as possible away from heavy current cables!
In all other respects, observe all local regulations when selecting the type of electrical cable and installing them!
In the case of “Intrinsically safe” explosion-proof, the supplementary information given on the type examination certifications,
the EN 60 079-14, and also local regulations applicable to electrical installation in explosion hazard areas must be taken into
account.
Rext max. [kΩ] =
Rext min. [kΩ] ≥
(6)
ON
(7)
(6)
(5)
(4)
Measuring mode/application DC voltage DC current
Measuring range limits ≤±1.7 V > ±1.7 to ≤±100 V > ±100 to ±1000 V ≤±100 mA ≤±1.5 mA
=Measuring input
=Measuring output
K = Output contact
(Option)
=Power supply
789
10 11 12 K
Standard
(Non-Ex)
Type of protection
“Intrinsic safety”
[EEx ia] IIC
Light emitting diodes
Green LED: Light after switching on the power supply
Output contact (Option)
Relay: For monitoring the measured value limit.
1 galvanically isolated switching contact
Contact rating: AC: ≤2 A / 250 V (500 VA)
DC: ≤2 A / 125 V (60 W)
Material: Gold flashed silver alloy
Trip point type: Programmable as low or high trip point
Trip point of measured variable
S
G
HGW
S
G
HGW
H Hysteresis GW Trip point
G Safe condition S Alarm condition
High trip point
Low trip point
Trip point adjustment
with PC for trip point: Programmable between – 10 and 110%***
Hysteresis: Programmable between > 0 and 100%***
Energizing and de-
energizing delays: Programmable between 0 to 1080 s
Relay contact position: Programmable
Frontplate signals: The green LED “ON” flashes when the limit
value is exceeded
*The type of output variable (current or voltage) is configurable with software
** An external supply fuse must be provided for DC supply voltages > 125 V
*** In relation to the analog output value range
8. Configuring the isolating amplifier
A PC, the programming cable PRKAB 600 (for Ex instruments) resp.
PRKAB 560 (for non-Ex instruments) plus ancillary cable and the
configuration software TV 800 plus are required to program the isolating
amplifier.
The connections between
“PC ↔PRKAB 600 resp. 560 ↔SINEAX TV 809” can be seen from
Fig. 6. The power supply must be connected in order to configure the
SINEAX TV 809.
The software TV 800 plus is supplied on a CD and runs under Windows
95 or higher.
The menu driven configuration software explains how to configure the
TV 809 and the choice of parameters.
The programming cable PRKAB 600 resp. PRKAB 560 adapts the signal
level and provides galvanic isolation between the PC and the SINEAX TV
809 isolating amplifier.
Continuation see on next page!
24… 60 V DC, AC
Programming
connector
Interface
SINEAX TV 809
PRKAB 600
Ancillary cable
11 12
789
GOSSEN
METRAWATT
CAMILLEBAUER
V624
Power supply
COM
Fig. 6. Configuring a SINEAX TV 809, Ex version.
123
456
–
+
123
456
–
+
123
456
–
+
123
456
–
+
Fig. 4. Switching function,
according to trip point type.

Other Camille Bauer Amplifier manuals

Camille Bauer SINEAX SV 824 User manual

Camille Bauer

Camille Bauer SINEAX SV 824 User manual

Camille Bauer SINEAX TV 808-11 User manual

Camille Bauer

Camille Bauer SINEAX TV 808-11 User manual

Camille Bauer SINEAX TV 808-12 User manual

Camille Bauer

Camille Bauer SINEAX TV 808-12 User manual

Camille Bauer SINEAX TV 809 User manual

Camille Bauer

Camille Bauer SINEAX TV 809 User manual

Camille Bauer SINEAX TV 808-115 User manual

Camille Bauer

Camille Bauer SINEAX TV 808-115 User manual

Camille Bauer SIRAX TV 808-61 User manual

Camille Bauer

Camille Bauer SIRAX TV 808-61 User manual

Camille Bauer SINEAX TV815 User manual

Camille Bauer

Camille Bauer SINEAX TV815 User manual

Camille Bauer GOSSEN METRAWATT SINEAX TV 808-115 User manual

Camille Bauer

Camille Bauer GOSSEN METRAWATT SINEAX TV 808-115 User manual

Camille Bauer SIRAX TV 808-62 User manual

Camille Bauer

Camille Bauer SIRAX TV 808-62 User manual

Popular Amplifier manuals by other brands

Koch LB 120-II operating instructions

Koch

Koch LB 120-II operating instructions

Focusrite OctoPre MkII Dynamic user manual

Focusrite

Focusrite OctoPre MkII Dynamic user manual

SPL Amplifiers Specification sheet

SPL

SPL Amplifiers Specification sheet

Altinex 1-In, 4-Out DA1957CT user guide

Altinex

Altinex 1-In, 4-Out DA1957CT user guide

Whirlwind PA-1 manual

Whirlwind

Whirlwind PA-1 manual

Inter-m PA-120 user guide

Inter-m

Inter-m PA-120 user guide

Arylic B50SE user manual

Arylic

Arylic B50SE user manual

Warwick Pro Tube IV owner's manual

Warwick

Warwick Pro Tube IV owner's manual

Mitsubishi Electric MELSERVO-J4 series instruction manual

Mitsubishi Electric

Mitsubishi Electric MELSERVO-J4 series instruction manual

Rotel RA971 owner's manual

Rotel

Rotel RA971 owner's manual

MRV Communications EM316EDFA-BR user guide

MRV Communications

MRV Communications EM316EDFA-BR user guide

SWR Spellbinder Blue Service manual

SWR

SWR Spellbinder Blue Service manual

LY International Electronics EF-804 manual

LY International Electronics

LY International Electronics EF-804 manual

HP 8447A Operating and service manual

HP

HP 8447A Operating and service manual

Technics SE-A808 Service manual

Technics

Technics SE-A808 Service manual

Marantz SR8012OM owner's manual

Marantz

Marantz SR8012OM owner's manual

Fender Bassbreaker BB 112 Enclosure user manual

Fender

Fender Bassbreaker BB 112 Enclosure user manual

SWR Natural Blonde owner's manual

SWR

SWR Natural Blonde owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.