CARNES VCDK040C User manual

MODELS
VCDK040C • VCDK050C • VCDK070C
CARNES COMPANY, 448 S. Main St., P.O. Box 930040, VERONA, WI 53593-0040 • Phone: 608.845.6411 • Fax: 608.845.6470 • www.carnes.com • [email protected]
Form 11217-A
Page 1
CEILING/WALL-MOUNT
VENTILATORS • 120V
READ AND SAVE THESE INSTRUCTIONS
WARNING
CAUTION
TABLE OF CONTENTS
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or telephone number listed.
Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the serv-
ice disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating
equipment manufacturer’s guidelines and safety standards
such as those published by the American Society for
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
To reduce the risk of fire, use only metal ductwork.
If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Interrupter) - protected branch cir-
cuit.
Never place a switch where it can be reached from a tub or
shower.
This unit must be grounded.
1.
2.
3.
For general ventilating use only. Do not use to exhaust haz-
ardous or explosive materials and vapors.
To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust, etc.
off power unit.
Please read specification label on product for further infor-
mation and requirements.
•
•
•
•
•
“TYPICAL INSTALLATION”
This sections shows a common installation in new and
existing, frame construction.
-Mounting (new construction)
-Mounting (existing construction)
-Wiring
-Ducting (straight-through blower discharge)
“DUCTING OPTIONS”
-Blower Discharge Positions
-Ducting (right-angle blower discharge)
“USE AND CARE”
“WARRANTY”
“SERVICE PARTS”
This manual is divided into sections as follows:
FORM 11217-A, Page 1
MODELS
VCDK040C • VCDK050C • VCDK070C
TYPICAL INSTALLATION
MOUNTING
(New Frame Construction)
10” ROUND DUCT
Grille
(Install after
Ceiling is
Finished)
7-1/2” x 11-1/4” TO 10”
ROUND TRANSITION
MOUNTING
FRAME
(Built on Site)
CEILING
JOIST
(24” Centers
Shown)
Factory-shipped unit installed in new construction.
10” ROUND
DUCT
Grille
7-1/2” x 11-1/4” TO
10” ROUND
TRANSITION
MOUNTING
FRAME
(Built on Site)
CEILING
JOIST
(24” Centers
Shown)
Factory-shipped unit installed in existing construction.
MOUNTING
(Existing Frame Construction)
FINISHED
CEILING
MATERIAL
2
MOUNTING
BRACKETS
TYPICAL INSTALLATION
WIRING
COVER PLATE
WHITE
TO
WHITE BLACK
TO
BLACK
120 VAC
LINE IN
Use U.L. approved connectors to wire per local codes. Connect
ground wire to bottom of conduit box.
IMPORTANT:
Remove shipping tape from damper.
Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork.
Use duct tape to make ductwork connections secure and air-tight.
DUCTING OPTIONS
BLOWER DISCHARGE POSITIONS
Horizontal discharge
position. (Factory Shipped)
Vertical discharge
position.
DUCT CONNECTOR
(Intake)
DUCT
CONNECTOR
(Intake)
DUCT CONNECTOR
(Discharge) DUCT
CONNECTOR
(Discharge)
Housing Disassembled and
Rotated To Be Re-Assembled
To Position Shown
FACTORY SHIPPED
MODELS
VCDK040C • VCDK050C • VCDK070C
DUCTING
(Vertical blower discharge)
WARRANTY
ROOF CAP
10”
ROUND
DUCT
7-1/2” x 11-1/4”
TO 10” ROUND
TRANSITION
Typical ductwork connection to a ventilator converted to
vertical discharge.
3
Seller warrants products manufactured by it and supplied here-
under to be free from defects in materials and workmanship under
normal use and proper maintenance for a period of twelve months
from date of shipment. If within such period any such products
shall be proved to Seller’s reasonable satisfaction to be defective,
such products shall be repaired or replaced at Seller’s option.
Seller's obligation and Buyer’s exclusive remedy hereunder shall
be limited to such repair and replacement and shall be condi-
tioned upon Seller’s receiving written notice of any alleged
defects no later than 10 days after its discovery within the war-
ranty period and, at Seller’s option, the return of such products to
Seller, f.o.b. its factory, when such return is feasible. Seller
reserves the right to satisfy its warranty obligation in full by reim-
bursing Buyer for all payments it makes hereunder, and Buyer
shall thereupon return the products to Seller. Seller shall have the
right to remedy such defects.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND
IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WAR-
RANTIES (EXCEPT TO TITLE) INCLUDING BUT NOT LIMITED
TO IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS
FOR A PARTICULAR PURPOSE, PERFORMANCE, OR OTH-
ERWISE, and in no event shall the Seller be liable for claims
(based upon breach of express or implied warranty, negligence,
product liability, or otherwise) for any other damages, whether
direct, immediate, incidental, foreseeable, consequential, or spe-
cial.
USE AND CARE
Ventilator is designed for continuous operation. If desired, it may
be controlled using an on/off switch or a solid-state, variable
speed control. Follow wiring instructions packed with control,
and adhere to all local and state codes, and the National
Electrical Code.
To clean blower assembly: Remove grille, disassemble two
cabinet halves, unplug blower from housing, remove blower
mounting nuts, and carefully remove blower from housing. Use
appropriate vacuum attachment or a soft cloth and mild soap or
detergent to clean blower discharge area and wheel. DO NOT
ALLOW WATER TO ENTER THE MOTOR. Make sure blower
assembly is completely dry before reinstalling.
Motor is permanently lubricated. Do not oil or disassemble
motor.
WARNING: To reduce the risk of electric shock,
disconnect from power supply before servicing.
Two ways to connect ductwork to a factory-shipped unit.
DUCTING
(Horizontal blower discharge)
7-1/2” x 11-1/4” TO
10” ROUND
TRANSITION
10” ROUND
ELBOW WALL
CAP
10”
ROUND
DUCT
ROOF CAP
MODELS
VCDK040C • VCDK050C • VCDK070C
SERVICE PARTS SERVICE PARTS
KEY NO. PART NO. DESCRIPTION QTY. REQ.
1 384-9201 Mounting Bracket 4
2 998-0028 Screw — #10 x 3/4” Self Drilling 5
3 999-6284 4 MFD Capacitor, VCDK 040C 1
3 999-6286 5 MFD Capacitor, VDCK 050C 1
3 999-6313 7 MFD Capacitor, VCDK 070C 1
4 402-2681 Capacitor Strap 1
5 992-3802 Motor (1/8 HP), VCDK 040C1
5 992-3804 Motor (1/6 HP), VCDK 050C1
5 992-3803 Motor (1/4 HP), VCDK 070C1
6 999-0069 Screw — 1/4-20 x 3/4” 3
7 999-2569 Blower Assembly (9 x 7) 1
8 384-9101 Fan Panel 1
9 384-9121 Discharge Flange 1
10 999-4701 Nut — 1/4-20 8
11 384-9141 Pivot Rod 1
12 384-9131 Damper Blade 1
13 999-0022 Screw — #10 x 1/2” 6
14 384-9181 Conduit Box 1
15 999-9916 Cable Connector 1
16 999-0040 HHCS — 1/4-20 x 7/8” 4
17 384-9111 Ceiling Fan Housing 1
18 384-9161 Housing Angle 1
19 384-9211 Perforated Steel Grille 1
20 999-9928 Cover Plate 1
21 901-0740 Screw Pkg 1
7
4
10
11
13
12 14
15
16
10
2
2
13
5
6
Order replacement parts by PART NO. - not by KEY NO.
9
8
448 South Main Street
P. O. Box 930040
Verona, WI 53593-0040
Phone: 608.845.6411 • Fax: 608.845.6470 • www.carnes.com • [email protected]
4
21
20
18
17
19

This manual suits for next models

2

Other CARNES Fan manuals

CARNES VCDD040I User manual

CARNES

CARNES VCDD040I User manual

CARNES LW/LM Owner's manual

CARNES

CARNES LW/LM Owner's manual

CARNES VW — BELT Assembly instructions

CARNES

CARNES VW — BELT Assembly instructions

CARNES HXBG User manual

CARNES

CARNES HXBG User manual

CARNES VCDK090C User manual

CARNES

CARNES VCDK090C User manual

CARNES VRBK User manual

CARNES

CARNES VRBK User manual

CARNES VCDK040I User manual

CARNES

CARNES VCDK040I User manual

CARNES VCDD090I User manual

CARNES

CARNES VCDD090I User manual

CARNES VFBB Assembly instructions

CARNES

CARNES VFBB Assembly instructions

CARNES LW/LM Owner's manual

CARNES

CARNES LW/LM Owner's manual

CARNES VCDD210I Administrator Guide

CARNES

CARNES VCDD210I Administrator Guide

Popular Fan manuals by other brands

Siegenia AEROTUBE 1 quick reference

Siegenia

Siegenia AEROTUBE 1 quick reference

Profile 545142018 manual

Profile

Profile 545142018 manual

aldes TAVA micro-watt Series Assembly instruction

aldes

aldes TAVA micro-watt Series Assembly instruction

Maico ECA 100 ipro KF product manual

Maico

Maico ECA 100 ipro KF product manual

Sealey HVD30110V instructions

Sealey

Sealey HVD30110V instructions

Livoo TEA272 instruction manual

Livoo

Livoo TEA272 instruction manual

MALTEC WK500Wt-lON instruction manual

MALTEC

MALTEC WK500Wt-lON instruction manual

Klarstein 10029404 manual

Klarstein

Klarstein 10029404 manual

Dru LUX LIGNUM Instructions for installation

Dru

Dru LUX LIGNUM Instructions for installation

Somogyi HOME SFS 40 instruction manual

Somogyi

Somogyi HOME SFS 40 instruction manual

Manrose Showerlite LEDSLKTC Installation and Wiring

Manrose

Manrose Showerlite LEDSLKTC Installation and Wiring

EDM PDFJY16DB instruction manual

EDM

EDM PDFJY16DB instruction manual

Emerson DC BUILDER ES Series owner's manual

Emerson

Emerson DC BUILDER ES Series owner's manual

atomi smart Smart WiFi quick start guide

atomi smart

atomi smart Smart WiFi quick start guide

Glen Dimplex Xpelair Premier CF20TX instruction manual

Glen Dimplex

Glen Dimplex Xpelair Premier CF20TX instruction manual

Vitek VT-1946 Manual instruction

Vitek

Vitek VT-1946 Manual instruction

Luminance Brands Kathy Ireland Home Highpointe LED CF205LBQ01 owner's manual

Luminance Brands

Luminance Brands Kathy Ireland Home Highpointe LED CF205LBQ01 owner's manual

Middle Atlantic Products UQFP-2D specification

Middle Atlantic Products

Middle Atlantic Products UQFP-2D specification

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.