Carrier Aritech Reliance XR Series Installation guide

Aritech Reliance XR Series
Installation and Programming
Guide
P/N 231040 • REV L • ISS 19JUL23

Copyright
© 2023 Carrier Fire & Security
All rights reserved.
This document may not be copied in whole or in part or otherwise reproduced
without prior written consent from Carrier Fire & Security, except where specifically
permitted under US and international copyright law.
Trademarks and patents
Aritech name and logo are trademarks of Carrier Fire & Security
IOS is the registered trademark of Cisco Technology, Inc.
Android, Google and Google Play are registered trademarks of Google Inc.
iPhone, Apple, iTunes are registered trademarks of Apple Inc.
App Store is a service mark of Apple Inc.
Other trade names used in this document may be trademarks or registered
trademarks of the manufacturers or vendors of the respective products.
Manufacturer
Placed on the market by:
Carrier Fire & Security
3211 Progress Drive, Lincolnton, NC, 28092, USA
Authorized EU manufacturing representative:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Warnings and Disclaimers
These products are intended for sale to, and installation by, an experienced security
professional. Carrier Fire & Security cannot provide any assurance that any person or
entity buying its products, including any “authorized dealer,” is properly trained or
experienced to correctly install security related products.
For more information on product warnings, refer to
firesecurityproducts.com/policy/product-warning/ or scan the code.
Contact information
For contact information, point of sale
Customer support
For customer support in Australia, point of sale
Firmware version
This manual was updated for firmware version A59P0000009-42

Installation and Programming Guide iii
Contents
Aritech Reliance XR Series Installation and Programming Guide ........... 1
Important information........................................................................ vi
Limitation of liability ...................................................................................vi
Product Warnings .......................................................................................vi
Warranty Disclaimers.................................................................................vii
Disclaimer .................................................................................................viii
Intended Use.............................................................................................viii
Advisory messages....................................................................................viii
Introduction ........................................................................................ 9
System Capacity...........................................................................................9
Aritech Reliance XR Specifications...................................................... 10
Product Codes........................................................................................... 10
Mains power specifications ...................................................................... 10
Power supply specifications...................................................................... 11
General features....................................................................................... 12
Current Consumption ............................................................................... 13
Output Current Rating .............................................................................. 13
Environmental........................................................................................... 13
Physical Dimensions and Weight.............................................................. 13
Fuses ......................................................................................................... 14
Maintenance............................................................................................. 14
System Monitoring ................................................................................... 15
SIA and CID reporting code descriptions.................................................. 15
End Of Line (EOL) Resistors....................................................................... 19
Aritech Reliance XR Pro Layout .......................................................... 20
Aritech Reliance XR Pro Wiring Diagram.................................................. 20
Aritech Reliance XR Pro Terminals............................................................ 21
Aritech Reliance XR Pro LEDs.................................................................... 22
Aritech Reliance XR Layout ................................................................ 23
Aritech Reliance XR Wiring Diagram......................................................... 23
Aritech Reliance XR LEDs .......................................................................... 25
Aritech Reliance XR Installation.......................................................... 26
Power Requirements ................................................................................ 26
Cable Requirements.................................................................................. 26
Shielding.................................................................................................... 26
Termination Links ..................................................................................... 26
Installing Panel.......................................................................................... 27
Installing Legacy NX Modules ................................................................... 27
Installing Antennas ................................................................................... 28
Enrolling Modules..................................................................................... 29
Deleting Modules...................................................................................... 29

iv Installation and Programming Guide
Defaulting Panel........................................................................................ 30
Defaulting Installer Account ..................................................................... 31
Getting Connected .............................................................................32
Account Access.......................................................................................... 32
Method 1: UltraSync+ App........................................................................ 33
Method 2: Web Server.............................................................................. 39
Method 3: DLX900 Management Software.............................................. 42
Method 4: NXX-1820-Keypad.................................................................. 44
Programming with App / Web Server .................................................45
Recommended Items to Change............................................................... 45
Learning Wireless Zones ........................................................................... 47
Adding a User............................................................................................ 52
Adding a Keyfob ........................................................................................ 53
Advanced Keyfob Programming ............................................................... 54
Configuring Email Reports ........................................................................ 56
Enabling Push Notifications on Smartphone ............................................ 57
Reporting to a Control Room.................................................................... 62
DLX900 Software................................................................................64
Installing DLX900....................................................................................... 64
Upgrading from DL900.............................................................................. 64
Login to DLX .............................................................................................. 64
Navigating the Main Window ................................................................... 66
Customer Window .................................................................................... 67
Navigating the Menus............................................................................... 68
Control Panel Menu .................................................................................. 69
Loading Control Panel Defaults................................................................. 69
Devices Menu............................................................................................ 70
Device Info ................................................................................................ 71
Download Menu........................................................................................ 72
Reading Data............................................................................................. 72
Sending Data ............................................................................................. 73
Tools Menu ............................................................................................... 74
Programming with DLX900.................................................................75
Programming Instructions for System Options ........................................ 75
Programming Instructions for Permissions............................................... 79
Programming Instructions for Menus....................................................... 81
Programming Instructions for Holidays.................................................... 83
Programming Instructions for Users......................................................... 87
Programming Instructions for Zones ........................................................ 90
Programming Instructions for Custom Zones........................................... 93
Programming Instructions for Areas......................................................... 96
Programming Instructions for Schedules.................................................. 99
Programming Instructions for Arm-Disarm ............................................ 103
Programming Instructions for Communicator........................................ 107
Programming Instructions for UltraSync ................................................ 111

Installation and Programming Guide v
Programming Instructions for Event Lists .............................................. 112
Programming Instructions for Channels................................................. 114
Programming Instructions for Zone Reporting....................................... 118
Programming Instructions for System Event Reporting......................... 121
Programming Instructions for Actions.................................................... 123
Programming Instructions for Action Groups ........................................ 125
Programming Instructions for Scenes .................................................... 127
Programming Instructions for Outputs .................................................. 128
Combining Actions with Schedules......................................................... 129
Arming and Disarming Your System ..................................................131
Lock Out On 3 Invalid Attempts.............................................................. 131
Arm Your System In Away Mode ............................................................ 131
Arm Your System In Stay Mode .............................................................. 131
Arm Your System in Instant Stay Mode.................................................. 131
Arm Your System In Night Mode ............................................................ 132
Disarm One Or More Areas .................................................................... 132
Activate SOS Feature .............................................................................. 132
Walk Test ................................................................................................ 133
User Reporting........................................................................................ 133
Appendix 1: System Status Messages................................................134
Appendix 2: App and Web Error Messages ........................................136
Appendix 3: Advanced Menu Tree.....................................................137
Appendix 4: Troubleshooting ............................................................138

vi Installation and Programming Guide
Important information
Limitation of liability
To the maximum extent permitted by applicable law, in no event will Carrier be liable for
any lost profits or business opportunities, loss of use, business interruption, loss of data, or
any other indirect, special, incidental, or consequential damages under any theory of
liability, whether based in contract, tort, negligence, product liability, or otherwise. Because
some jurisdictions do not allow the exclusion or limitation of liability for consequential or
incidental damages the preceding limitation may not apply to you. In any event the total
liability of Carrier shall not exceed the purchase price of the product. The foregoing
limitation will apply to the maximum extent permitted by applicable law, regardless of
whether Carrier has been advised of the possibility of such damages and regardless of
whether any remedy fails of its essential purpose.
Installation in accordance with this manual, applicable codes, and the instructions of the
authority having jurisdiction is mandatory.
While every precaution has been taken during the preparation of this manual to ensure the
accuracy of its contents, Carrier assumes no responsibility for errors or omissions.
Product Warnings
YOU UNDERSTAND THAT A PROPERLY INSTALLED AND MAINTAINED ALARM/SECURITY
SYSTEM MAY ONLY REDUCE THE RISK OF EVENTS SUCH AS BURGLARY, ROBBERY, FIRE, OR
SIMILAR EVENTS WITHOUT WARNING, BUT IT IS NOT INSURANCE OR A GUARANTEE THAT
SUCH EVENTS WILL NOT OCCUR OR THAT THERE WILL BE NO DEATH, PERSONAL INJURY,
AND/OR PROPERTY DAMAGE AS A RESULT.
THE ABILITY OF INTEROGIX’S PRODUCTS, SOFTWARE OR SERVICES TO WORK PROPERLY
DEPENDS ON A NUMBER OF PRODUCTS AND SERVICES MADE AVAILABLE BY THIRD PARTIES
OVER WHICH ARITECH HAS NO CONTROL AND FOR WHICH ARITECH SHALL NOT BE
RESPONSIBLE INCLUDING, BUT NOT LIMITED TO, INTERNET, CELLULAR AND LANDLINE
CONNECTIVITY; MOBILE DEVICE AND OPERATING SYSTEM COMPATIBILITY; MONITORING
SERVICES; ELECTRONMAGNETIC OR OTHER INTERFERENCE, AND PROPER INSTALLATION
AND MAINTENANCE OF AUTHORIZED PRODUCTS (INCLUDING ALARM OR OTHER CONTROL
PANEL AND SENSORS).
ANY PRODUCT, SOFTWARE, SERVICE OR OTHER OFFERING MANUFACTURED, SOLD OR
LICENSED BY ARITECH, MAY BE HACKED, COMPROMISED AND/OR CIRCUMVENTED AND
ARITECH MAKES NO REPRESENTATION, WARRANTY, CONVENANT OR PROMISE THAT ITS
PRODUCTS (INCLUDING SECURITY PRODUCTS), SOFTWARE, SERVICES OR OTHER OFFERINGS
WILL NOT BE HACKED, COMPROMISED AND/OR CIRCUMVENTED.
ARITECH DOES NOT ENCRYPT COMMUNICATIONS BETWEEN ITS ALARM OR OTHER
CONTROL PANELS AND THEIR WIRELESS OUTPUTS/INPUTS INCLUDING BUT NOT LIMITED
TO, SENSORS OR DETECTORS UNLESS REQUIRED BY APPLICABLE LAW. AS A RESULT, THESE
COMMUNICATIONS MAY BE INTERCEPTED AND COULD BE USED TO CIRCUMVENT YOUR
ALARM/SECURITY SYSTEM.

Installation and Programming Guide vii
THE EQUIPMENT SHOULD ONLY BE OPERATED WITH AN APPROVED POWER ADAPTER WITH
INSULATED LIVE PINS.
DO NOT CONNECT TO A RECEPTACLE CONTROLLED BY A SWITCH.
THIS UNIT INCLUDES AN ALARM VERIFICATION FEATURE THAT WILL RESULT IN A DELAY OF
THE SYSTEM ALARM SIGNAL FROM THE INDICATED CIRCUITS. THE TOTAL DELAY (CONTROL
UNIT PLUS SMOKE DETECTORS) SHALL NOT EXCEED 60 SECONDS. NO OTHER SMOKE
DETECTOR SHALL BE CONNECTED TO THESE CIRCUITS UNLESS APPROVED BY THE LOCAL
AUTHORITY HAVING JURISDICTION.
WARNING: The equipment should only be operated with an approved power adapter with
insulated live pins.
Caution: Risk of explosion if battery is replaced by an incorrect type. Dispose of batteries
according to the instructions. Contact your supplier for replacement batteries.
Warranty Disclaimers
ARITECH HEREBY DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS, WHETHER
EXPRESS, IMPLIED, STATUTORY OR OTHERWISE, INCLUDING ANY IMPLIED WARRANTIES,
THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
(USA only) SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES, SO
THE ABOVE EXCLUSION MAY NOT APPLY TO YOU. YOU MAY ALSO HAVE OTHER LEGAL
RIGHTS THAT VARY FROM STATE TO STATE.
ARITECH DOES NOT MAKE ANY CLAIMS OR WARRANTIES TO YOU OF ANY KIND REGARDING
ANY PRODUCT, SOFTWARE OR SERVICE’S POTENTIAL, ABILITY, OR EFFECTIVENESS TO
DETECT, MINIMIZE, OR IN ANYWAY PREVENT DEATH, PERSONAL INJURY, PROPERTY
DAMAGE, OR LOSS OF ANY KIND WHATSOEVER.
ARITECH DOES NOT REPRESENT TO YOU THAT ANY PRODUCT (INCLUDING SECURITY
PRODUCTS), SOFTWARE, SERVICE OR OTHER OFFERING MAY NOT BE HACKED,
COMPROMISED AND/OR CIRCUMVENTED.
ARITECH DOES NOT WARRANT THAT ANY PRODUCT (INCLUDING SECURITY PRODUCTS),
SOFTWARE OR SERVICE MANUFACTURED, SOLD OR LICENSED BY ARITECH WILL PREVENT,
OR IN ALL CASES PROVIDE ADEQUATE WARNING OF OR PROTECTION FROM, BREAK-INS,
BURGLARY, ROBBERY, FIRE, OR OTHERWISE.
ARITECH DOES NOT WARRANT TO YOU THAT ITS SOFTWARE OR PRODUCTS WILL WORK
PROPERLY IN ALL ENVIRONMENTS AND APPLICATIONS AND DOES NOT WARRANT ANY
PRODUCTS AGAINST HARMFUL ELECTROMAGNETIC INTERFERENCE INDUCTION OR
RADIATION (EMI, RFI, ETC.) EMITTED FROM EXTERNAL SOURCES
ARITECH DOES NOT PROVIDE MONITORING SERVICES FOR YOUR ALARM/SECURITY SYSTEM
(“MONITORING SERVICES”). IF YOU ELECT TO HAVE MONITORING SERVICES YOU MUST
OBTAIN SUCH SERVICE FROM A THIRD PARTY AND ARITECH MAKES NO REPRESENTATION
OR WARRANTY WITH RESPECT TO SUCH SERVICES INCLUDING WHETHER OR NOT THEY
WILL BE COMPATIBLE WITH THE PRODUCTS, SOFTWARE OR SERVICES MANFUFACTURED,
SOLD OR LICENSED BY ARITECH.

viii Installation and Programming Guide
Disclaimer
THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE.
CARRIER ASSUMES NO RESPONSIBILITY FOR INACCURACIES OR OMISSIONS AND
SPECIFICALLY DISCLAIMS ANY LIABILITIES, LOSSES, OR RISKS, PERSONAL OR OTHERWISE,
INCURRED AS A CONSEQUENCE, DIRECTLY OR INDIRECTLY, OF THE USE OR APPLICATION OF
ANY OF THE CONTENTS OF THIS DOCUMENT. FOR THE LATEST DOCUMENTATION,
CONTACT YOUR LOCAL SUPPLIER OR VISIT US ONLINE AT
WWW.UTCFIREANDSECURITY.COM.
This publication may contain examples of screen captures and reports used in daily
operations. Examples may include fictitious names of individuals and companies. Any
similarity to names and addresses of actual businesses or persons is entirely coincidental.
The illustrations in this manual are intended as a guide and may differ from your actual unit
as Aritech Reliance XR is continually being improved.
Intended Use
Use this product only for the purpose it was designed for; refer to the data sheet and user
documentation. For the latest product information, contact your local supplier or visit us
online at www.utcfireandsecurity.com.
The system should be checked by a qualified technician at least every 3 years and the
backup battery replaced as required.
Advisory messages
Advisory messages alert you to conditions or practices that can cause unwanted results.
The advisory messages used in this document are shown and described below.
WARNING: Warning messages advise you of hazards that could result in injury or loss of
life. They tell you which actions to take or to avoid preventing the injury or loss of life.
Caution: Caution messages advise you of possible equipment damage. They tell you which
actions to take or to avoid preventing damage.
Note: Note messages advise you of the possible loss of time or effort. They describe how to
avoid the loss. Notes are also used to point out important information that you should read

Installation and Programming Guide 9
Introduction
The Aritech Reliance XR is an advanced intrusion panel with native IP reporting to
UltraSync cloud. It has been designed for smartphone access to allow professional
installer programming, and end-users’ convenient access.
With large expansion capabilities, multi-area mode, wireless expansion, advanced user
permissions, advanced schedules, and smart home features, the Aritech Reliance XR is
suitable for residential and small commercial applications.
The system can be quickly programmed using drop-down menus in the UltraSync+ app.
Programming is possible using a web browser or DLX900 desktop software.
All zones, areas, lists, groups, outputs, schedules, permission profiles, and defaults can
be assigned a text name to make it easy to program and maintain.
When installed with the NXX-1820- touchscreen keypad, menus appear as plain text on
a clear 3.5” screen with access to all programming features.
System Capacity
Feature
Aritech Reliance XR
Aritech Reliance XR Pro
On-board zones
Zone doubled
4
8
8
16
Wireless Zones
16
176
Wireless Receiver
63-bit and
80plus encrypted devices
63-bit and
80plus encrypted devices
Areas
4
8
Users
40
256
Max Keyfobs
8
16
Max Tablets
4
4
Max Expander Modules
incl Keypads
32 Total
[16 Keypads max]
32 Total
[24 Keypads max]
IP Communicator
Built-in
Built-in
UltraSync+ app
Yes
Yes

10 Installation and Programming Guide
Aritech Reliance XR Specifications
Product Codes
Product
Main description
Additional description
NXX-8-W-AU
Aritech Reliance XR Pro
Aritech Reliance XR Pro Panel /w 8 Hardwired
Zones, 433/433MHz 80 Bit, Home Automation,
metal housing, tamper switch
NXX-4-W-AU
Aritech Reliance XR
Aritech Reliance XR Panel /w 4 Hardwired
Zones, 433/433MHz 80 Bit, metal
housing, tamper switch
NXX-8-W-BO-AU
Aritech Reliance XR Pro, Board Only
Aritech Reliance XR Pro Panel /w 8
Hardwired Zones, 433/433MHz 80
Bit, 921.42MHz
NXX-4-W-BO-AU
Aritech Reliance XR,
Board Only
Aritech Reliance XR Panel /w 4 Hardwired
Zones, 433/433MHz 80 Bit, board only
NXX-4GWF
4G & WiFi Router Module
Dual SIM 4G cellular and WiFi router
module
NXX-1820
Touchscreen Keypad
3.5” Touchscreen keypad, multilingual
RF-EV1016-K4
Wireless Mirror Optic PIR Two Way
80plus
RF-4041-07-2
4-button Keyfob Two Way, 433Mhz
80plus
RF-DC101-K4
Wireless Door Window Switch,
433MHz 80plus
RF-1110-07-1
Micro Door Window Switch Two
Way, 433MHz 80plus White
RF-EV1012PI-K4
Wireless Mirror Optic Pet Immune
PIR Two Way 80plus
RF-7120-07-1
"Designer" Stand-alone Wireless
Indoor Siren (800mAh)
RF-7220-07-1
"Designer" Stand-alone Wireless
Outdoor Siren
BS7201-N
Lithium Battery for RF-7220-07-1
Mains power specifications
Mains input voltage
230 Vac +10%, −15%, 50 Hz ±10%
Current consumption at 230 Vac
240 mA max.
Transformer output :
16.3 VAC 24 VA
16.3 VAC 48 VA

Installation and Programming Guide 11
Power supply specifications
Power supply type
For indoor use inside the supervised premises
Power supply voltage
13.8 VDC +/- 0.4 V
Power supply current
2 A max. at 13.8 VDC +/- 0.4 V
Main board consumption
Aritech Reliance XR Pro
130 mA at 13.8 VDC +/- 0.4 V
Aritech Reliance XR
130 mA at 13.8 VDC +/- 0.4 V
Maximum system current available
Aritech Reliance XR Pro
Aritech Reliance XR
2000 mA at 13.8 VDC +/- 0.4 V
2000 mA at 13.8 VDC +/- 0.4 V
Auxiliary power output (AUX. POWER)
Aritech Reliance XR Pro
Aritech Reliance XR
13.8 VDC +/- 0.2 V, 1 A max.
13.8 VDC +/- 0.2 V, 1 A max.
Battery power output (BAT)
Aritech Reliance XR Pro
Aritech Reliance XR
13.8 VDC +/- 0.2 V, 350 mA max.
13.8 VDC +/- 0.2 V, 350 mA max.
Battery type
Lead acid rechargeable
7.2 Ah 12 V nominal
Minimum voltage
9.45 VDC
Maximum voltage at power supply,
auxiliary power output and battery
power output
14.5 VDC
Battery low condition
11.3 Vdc to 11.8 Vdc
Battery disconnect voltage
9.77 Vdc
Maximum ripple voltage V, p-p
200 mV typical, 400 mV max.

12 Installation and Programming Guide
General features
Code combinations
Aritech Reliance XR Pro
Aritech Reliance XR
From 10,000 (4 digits) to 100,000,000 (8 digits)
From 10,000 (4 digits) to 100,000,000 (8 digits)
Maximum user number:
Aritech Reliance XR Pro
Aritech Reliance XR
256
40
User Permissions
128
Onboard zones
Aritech Reliance XR Pro
Aritech Reliance XR
8 (default); 16 if zone doubling enabled.
4 (default); 8 if zone doubling enabled.
Maximum zone number:
Aritech Reliance XR Pro
Aritech Reliance XR
176
24
Additional inputs
Aritech Reliance XR Pro
Aritech Reliance XR
1: box tamper
1: box tamper
End-of-line resistor
820 Ω(2-wire smoke)
3.3 kΩ, 4.1 kΩ, 4.7 kΩ(alarm)
3.74 kΩ, 6.98 kΩ(zone doubling)
Onboard outputs:
Aritech Reliance XR Pro
Aritech Reliance XR
4 programmable outputs, bell, and smoke
3 programmable outputs, and bell
Maximum output number
32
Maximum action number
256, main panel supports 32 actions, each output module adds 32
actions, seven output modules will provide a maximum of 256
actions
Areas:
Aritech Reliance XR Pro
Aritech Reliance XR
8
4
Maximum keypad
Aritech Reliance XR Pro
Aritech Reliance XR
24
16
Maximum expander modules (incl keypads
and tablets)
32
Non-volatile Memory
Event log capacity
Data retention (log, program settings)
1024
10 years
Ethernet connection (IP only)
Supported standard
Speed
Duplex
Cabling
IEEE 802.3u
10BASE-T or 100BASE-TX
Half-duplex and full-duplex
FTP (foiled twisted pair) Cat 5e cable or better
Aritech Reliance XR bus
Type
Capacity
Range
Recommended Cable
4 wire RS485 bus
High common mode tolerance (25V)
Up to 32 devices
800m
Belden 7201A, 3107A, 9842, or exact equivalent 2 pair twisted
shielded cable designed for RS485 (see "
Cable Requirements" on page 26)

Installation and Programming Guide 13
Current Consumption
Product
Main description
Current Consumption
(non-alarm)
Current Consumption
(alarm)
NXX-8-WZ-AU
Aritech Reliance XR Pro
130 mA typical
130 mA typical
NXX-4-W-AU
Aritech Reliance XR
130 mA typical
130 mA typical
NXX-1820
Touchscreen keypad
100 mA typical,
40 mA in idle mode
175 mA max with
sounder and screen on
max brightness
Output Current Rating
Aritech Reliance XR Pro / Aritech Reliance XR (AU)
Output
Total Max Output Current
24 VA
Transformer
48 VA
Transformer
Combined J2 BELL+, J2 AUX+ (Smoke),
and J7 AUX+ (Outputs)
650 mA max at
13.8 VDC
1.6 A max at
13.8 VDC
Combined J2 POS (XR Bus), and J3 POS (NX Bus)
Environmental
Operating temperature
−10 to +55°C
Humidity
95% non-condensing
IP protection grade
IP30
Physical Dimensions and Weight
Product
Main description
Dimensions (HxWxD)
Weight (g)
NXX-8-WZ-AU
Aritech Reliance XR Pro /w metal enclosure
and tamper
292 x 291 x 91 mm
(enclosure only)
437 x 291 x 91 mm
(with antennas)
2075 g
NXX-4-W-AU
Aritech Reliance XR /w metal enclosure and
tamper
214 x 232 x 94 mm
(enclosure only)
359 x 232 x 94 mm
(with antennas)
1435 g
NXX-8-WZ-BO-AU
Aritech Reliance XR Pro, board only
273 x 89 x 25 mm
210 g
NXX-4-W-BO-AU
Aritech Reliance XR,
board only
192 x 89 x 25 mm
155 g
NXX-1820
Touchscreen keypad
18 x 82 x 125 mm
150 g

14 Installation and Programming Guide
Fuses
Battery
4 A, resettable
12 V aux (combined for J2 BELL+, J2 AUX+, J7 AUX+)
3 A, resettable
System LAN (combined for J2 POS, J3 POS)
2 A, resettable
Maintenance
No regular maintenance needed. System will report servicing when necessary.

Installation and Programming Guide 15
System Monitoring
The system provides monitoring for the following items.
Monitoring function
Message
Cause
AC Mains
Mains fail
Loss of external power supply [1]
Battery
Battery low
Battery low voltage [1]
Battery test fail
Exhausted battery
Battery charger fail
Fuse/power output fail
Output overload
Power outputs
Fuse/power output fail
Exhausted fuse
Fuse loss
Short circuit
Overload
Power supply
Power unit/power output fail
Power unit failure
Overvoltage
Tampers
Device tamper
Device sabotage
SIA and CID reporting code descriptions
CID Code
Class
SIA Code
Event
E110
Alarm
FA
Fire alarm
R110
Alarm restore
FR
Fire alarm restore
E120
Alarm
PA
24 hour alarm
R120
Alarm restore
PR
24 hour alarm restore
E130
Alarm
BA
Burg alarm
R130
Alarm restore
BR
Burg alarm restore
E570
Bypass
B
Bypass
R570
Bypass
U
Bypass restore
E383
Zone tamper
TA
Tamper
R383
Zone tamper
TR
Tamper restore
E380
Trouble
T
Trouble
R380
Trouble
R
Trouble restore
E384
Sensor batt
XT
Sensor low battery
R384
Sensor batt
XR
Sensor low battery restore
E381
Sensor lost
S
Wireless supervision
R381
Sensor lost
R
Wireless supervision restore
E200
Sensor lost
SS
Fire supervision
R200
Sensor lost
SR
Fire supervision restore
E391
Sensor lost
NA
Zone activity supervision
R391
Sensor lost
NS
Zone activity supervision restore
E378
Alarm
BG
Cross zone initial trip
R378
Alarm
BR
Cross zone initial trip restore
E389
Sensor batt
AS
Fire maintenance alarm
R389
Sensor batt
AN
Fire maintenance alarm restore
E426
Access alarm
DL
Door propped

16 Installation and Programming Guide
R426
Access alarm
DH
Door propped
E423
Access alarm
DF
Door forced
R423
Access alarm
DR
Door forced
E611
Test
TP
Start walk test zone
E389
Test
TE
End zone test
E611
Test
TP
Walk test zone passed
E389
Test
TE
Walk test zone failed
E383
Zone tamper
TA
Tamper
R383
Zone tamper
TR
E139
Alarm
BA
E130
Alarm
BV
E129
Alarm
HA
E120
Alarm
HV
E129
Alarm
PA
E120
Alarm
HV
E115
Manual alarm
FA
Manual fire
E100
Manual alarm
MA
Manual medical
E123
Manual alarm
PA
Manual audible panic
E122
Manual alarm
HA
Manual silent panic
E124
Manual alarm
HA
Duress
E461
Tamper
JA
Keypad lockout
E137
Tamper
TA
Box tamper
R137
Tamper
TR
Box tamper restore
E301
Ac power
AT
Mains fail event
R301
Ac power
AR
Mains fail event restore
E302
Battery power
YT
Battery low event
R302
Battery power
YR
Battery low event restore
E312
Aux power
YI
Over current
R312
Aux power
YJ
Over current restore
E320
Siren trouble
YA
Siren tamper
R320
Siren trouble
YH
Siren tamper restore
E351
Telephone cut
LT
Telephone fault
R351
Telephone cut
LR
Telephone fault restore
E354
Comms fail
YC
Communication failure
R354
Comms fail
YK
Communication failure restore
E333
Expander trouble
ET
Device failure
R333
Expander trouble
ER
Device failure restore
E401
Open
OP
Open
R401
Open
CL
Close
E401
Open
OP
First open
R401
Open
CL
Last close
E451
Open
CG
Partial close
E374
Recent close
EE
Exit error
E459
Recent close
CR
Recent close
E406
Cancel
AB
Abort
E406
Cancel
OC
Cancel
E602
Automatic test
RP
Automatic test
E601
Test
RX
Manual test
E625
Local program
JT
Clock changed
E627
Local program
LB
Start local program

Installation and Programming Guide 17
E628
Local program
LX
End local program
E627
Remote program
RB
Start remote program
E628
Remote program
RS
End remote program
E607
Test
TS
Start walk test mode
R607
Test
TE
End walk test mode
E466
Recent close
Technician arrival
R466
Recent close
YZ
Technician left
E310
System troubles
FT
Ground fault
R310
System troubles
FR
Ground fault restore
E606
Alarm
LF
Start listen in
R606
Alarm
LE
End listen in
E451
Open
OK
Early opening (disarmed before opening
window)
R452
Open
CJ
Late closing (armed after the opening window)
E453
Open
OI
Fail to open
E454
Open
CI
Fail to close
E344
System troubles
XQ
Wireless jam
R344
System troubles
XH
Wireless jam restore
E414
System troubles
System shut down
R414
System troubles
RR
System turn on
E323
Access
RC
Output activated
R323
Access
RO
Output restored
E531
Expander trouble
SC
Device enrolled
E422
Access
DG
User activated output
E422
Access
DG
Door access
E421
Access
DV
Door access denied
E305
Comms fail
YW
Watchdog reset
R451
Open
OP
Partial open
E401
Abortable alarm
BC
Abort alarm
E102
Access
JK
Guard tour fail
E641
Test
NA
Activity monitor fail
E422
Access
DG
Valid code entered
E421
Access
DP
Valid code out schedule
E421
Access
DV
Valid code void
E421
Access
DV
Valid code lost
E421
Access
DV
Valid code expired
E628
Access
RU
Remote program fail
E102
Access
CL
Man down rearm
E305
Expander trouble
RR
Powerup
R305
Expander trouble
RR
Powerup restore
R601
Test
RX
Manual test restore
E452
Open
OJ
Late opening
R451
Open
CK
Early closing
E532
Device bypass
UB
Device bypass
E531
Device bypass
UU
Device unbypass
E304
Checksum fault
YF
Checksum failure
R304
Checksum fault
YG
Checksum failure restore
E338
Battery power
YT
Expander low battery
R338
Battery power
YR
Checksum failure restore
E337
Battery power
YT
DC fail
R337
Battery power
YR
DC fail restore

18 Installation and Programming Guide
E609
Video
Video event
E351
Comms fail
LT
IP path fault
R351
Comms fail
LR
IP path fault restore
E458
Open
Geo fence 1 entered
R458
Open
Geo fence 1 exited
E458
Open
Geo fence 2 entered
R458
Open
Geo fence 3 exited
R351
System troubles
LR
Power supply fault
R351
System troubles
LR
Power supply fault restore

Installation and Programming Guide 19
End Of Line (EOL) Resistors

20 Installation and Programming Guide
Aritech Reliance XR Pro Layout
Aritech Reliance XR Pro Wiring Diagram
This manual suits for next models
6
Table of contents
Other Carrier Control Panel manuals

Carrier
Carrier Infinity SYSTXCCUID01-B User manual

Carrier
Carrier 2X-A/2X User manual

Carrier
Carrier SmartVu control User manual

Carrier
Carrier Touch Pilot Junior User manual

Carrier
Carrier Touch Pilot 30XW-V User manual

Carrier
Carrier INFINITY ZONING CONTROL User manual

Carrier
Carrier SmartVu control User manual

Carrier
Carrier HumidiTrac Setup guide
Popular Control Panel manuals by other brands

Truma
Truma CP plus operating instructions

Cimon
Cimon Xpanel 4 user manual

Secutron
Secutron MGC MIX-4000 Series Installation and operation manual

Leviton
Leviton Melange Pro Features

LOVATO ELECTRIC
LOVATO ELECTRIC RGK 50 instruction manual

Ravel
Ravel RE-2504 Installation, commissioning & operating user manual