Carrier HumidiTrac Setup guide

HUMIDITRAC'°HUMiDiFiERCONTROL
SAFETY AND iNSTALLATiON iNSTRUCTiONS
READ COMPLETE iNSTALLATiON iNSTRUCTiONS AND TEMPLATE BEFORE STARTING.
Attention Installer: _ This product must be installedby a qualified heating and air conditioning contractor.
Failure to do so could result in serious injury from electrical shock.
THESEiNSTALLATiONiNSTRUCTiONSAREFORTHEHUMIDITRAC'°HUMiDiFiERCONTROLONLY!
ForHumidifierinstaJiation,follow HumidifierInstaJiationinstructions.
STEP1:Unpackthe Humidifier Control Carton
MakesureaJJcomponentsare present(seeFigureA):
A.HumidifierControl C.ManualMode Label
B.OutdoorTemperatureSensor D.Manual ModeResistorCase
HUMIDIFIER
PAD CHANGE
INDICATOR
STEP2:Disassemblethe HumidifierControl
Removedoorfromthe HumidifierControlby pullingthe bottomofthe door
straightout.
STEP3:ChecktheModeSwitch
With the door removed,noticethe switch labeledBYPASSand POWER
(partiallycovered bythe enclosure).Make surethe switch is correctly set
for the humidifiermodelbeinginstalled or damageto the HumidifierControl
could result(seeSTEP12"Wiring").
STEP 4: Check the Change HumidifierPad indicatorSetting
This settingwiil controlwhen the indicatorlightturnson, remindingyou
to changeyour HumidifierPad.Ifyour Controlcamewith ahumidifier,the
Controlispre-setat position"C". If the installationsitehasa 3-month
or shorterheatingseasonor very hardwater,youmaywant toadjustthe
setting.(seeFigureB).TheControlmust beenergizedto resetthe
HumidifierPad Indicator.
STEP5:Determine Location for HumidifierControl
and Mount it
HumidifierControlmust bemountedinthe ReturnDuct.Forproper
operation,the HumidifierControlmust beatleast6inches upstreamof any
ofthe following:
.Humidifier
. HumidifierBypassDuctwork(if applicable)
.FreshAir intake Ductwork (ifapplicable)(see FigureC)
After locationfor Controlisselected,usethe perforatedHumidifierControl
template(attachedtothese instructions)to markthe duct openingandcutit.
Use4sheetmetalscrews (notprovided)to mountthe HumidifierControlin
the duct openingandmakesure HumidifierControlissealedtightly to duct.
\\AUTOMATICMO0_
FigureA DOOR
Use the "OFF" setting to turn the
Humidifier Pad Change indicator OFF. /Af ._=B HUMIDIFIER
Use setting"A"forvery _---/OFF( _ }c 7_ADTIINDGICATOR
severewaterconditions._ ,_ \ I I , / /-BYPASS/POWER
Humidifier Pad Change 7 _--"_ _4_ / /MODEGV/ MODESWITCH
indicator LED light will (OFF(( (_)}C _ \ p ,_
activate after 75hours of \ _
solenoid valve operation. _
Use setting "B" for clinlate _ _ 4f ll "AL_
withmilderwinterstypical "_ A_. -- _ II/)1/
of the South. Humidifier Pad /_, 7_, _ _/t_/ _ ]
ChangeindicatorLEDlight /OFF|/ _ l| ° /
will activate after300 hoursk _ _ 90-1o10
of solenoid valve operation._ A_B '_4
Use setting "O" for winters in the MidwestJ 1=(( _ ))c_
and Eastern United States. Humidifier Pad _ _/
Change indicator LED light will activate after
600 hours of solenoid valve operation. Figure B
FigureC RETURN\
DUCT
HUMIDIFIER/
CONTROL
INTAKE
_COIL
CONNECTION
90-1137

STEPG:Determine Locationfor Outdoor TemperatureSensor
Thelocationofthe OutdoorTemperatureSensormust meetthesethree requirements:
1. Must bemountedon North, Eastor West side ofhouseoutof direct sunlight
2. Must beat least 3feetfrom all exhaustvents
3. Must beaboveexpectedsnow line(SeeFigureD)
incorrect humiditylevelswill result if theserequirementsare notmet.
STEP7:Locate ExistingAccess Hole to Outside
A convenientway to get the Sensorwire outsideisto makeuseof unused
wires runningto the A/C condensingunit(if applicaNe).Otherways areto use
existing holesfor CaNeTV lines,telephone lines,A/C lines,etc. Readall
equipmentinstructions beforehandfor possiNe conflicts andwarnings.
FigureD
OUTDOO_
TEMPERATURESENSOR
LEADS
NORTH, EAST
ORWEST SIDE
OFHOME
T
ABOVE EXPECTED
SNOW LINE
OUTDOOR
TEMPERATURE
SENSOR
SENSOR
BRACKET
STEP 8: Alternate Locationfor Outdoor TemperatureSensor
TheSensor canalso bemountedinthe center of either:
. 2inch PVCfreshair intake pipefor the furnace
OR
. 6inchfresh air intakeduct. Mountthe sensorwith a #8galvanizedscrew.
Jnbothcases,the Sensormust heno morethan3 feet fromthe outsidewaJJ.
See FigureE.
if itis notfeasibleto usethe OutdoorTemperatureSensorinany ofthe ways
described,the HumidifierControlcanbe installed for Manual Operation.
See boxbelow and FigureGfor details.
STEP 9: Routethe Wire from Control to Sensor
iiiiii] J
..... 36,_MAX_ I
OUTSIDE WALL
FigureE
_-_ CENTERLINE
Runwire to the outdoortemperature sensor.Sensor is not affectedbylead length. Donot runoutdoor temperaturesensor alongsidewires carryinghigh
voltage (120VACor higher).Secure the sensor bracketwith a #8galvanizedscrew.
STEP10:AttachSensorWire to
Humidifier Control
Stripwire 1/4inch,and insertthe wiresfrom
the Sensor intothe terminals hbeled "ODT"
onthe HumidifierControl.SeeFigureFfor
location ofterminals.
i O
FigureF 9o-_o_2
STEP11:Determine Power Source for Humidifier Control
Determinewhere you will get 24VACto power the Humidifier Controlbasedonthe 2 optionsbelow:
OPTION1:FURNACESWiTH ACCESSORYTERMINALS.if the accessoryterminals provide:
. 24VAC:Wire these directly to the "R" and "C" terminals onthe Humidifier Control.
. 120VAC:Wire to a 24VACtransformer,which in turn connectstothe "R" and"C"
terminals onthe Humidifier Control.
in either case,the voltageto the HumidifierControlmustbe between 22VAC- 30VAC.
OPTION2: EXTERNAL24VACTRANSFORMER:
Wire into a power source otherthan the furnace
blower circuit. Thetransformer can be poweredoff
the 120VACline atthe junction box beforeit enters
the furnace.The24volt sideofthe transformer is
connectedto the "R" and "C" terminalsonthe
HumidifierControl.
NOTES: TheHumidifier Controlwill operate propedywith either a switched or continuouspowersource.
Whether using ACCESSORYTERMINALSORan EXTERNALTRANSFORMER,the minimumVArequired is; 2.0VAfor
PowerHumidifiers;or 10.0VAfor BypassHumidifiers.
When power is connectedfor the first time,the redand greenLEDswill light momentarily.
STEP12:Wiring
NOTE:The controlwill function with either aswitched or continuous24VACpower source. SeeDiagramsA-Dfor wiring options.

FAN POWERED HUMiDiFiER WiRiNG DIAGRAM
DiagramA
STANDARDFURNACE;VARIABLESPEEDFURNACE;VARIABLE SPEEDFANCOiL
vi HUMIDITRAC CONTROL
VARIABLE SPEED WIRING TERMINALS
FANCOIL ..... ii R24V° ii I--Hq ii rOOt] iI
HUM 2
24VAC c (COMMON}
TERMINALS HUM
ON FURNACE (HUMIDIFIER}
STANDARD FURNACE &
VARIABLE SPEED FURNACE HUMIDIFIER
HUMIDIFIER CORD _2
PLUGGED INTO
120 VAC POWER SOURCE 4VACLEADS
OUTDOOR
__ TEMPERATURE
SENSOR
SWITCHPOSITION
POWER
MODELS
HUMCCLFP1418
HUMDBLFP1418
P110-LFP1418
DiagramB HUMIDITRACCONTROL
WIRING TERMINALS
STANDARDFAN COIL IiR2_voIir.n Ii roD,1',
IC _ J_ _ d_ _ CI
......1311_ ..... DUTDDDB
--UIIU -- -- / / I__ TEMPERATURE
TRANSFORMER HUMIDIFIER | | SENSOR
(FIELDSUPPLIED) _ / /
FURNACE/A TOTALINE PII0-0050
BLOWER MOTOR CURRENTSENSING
HUMIDIFIER CORD _ / /f_ _\)R _] RELAY
PLUGGEDINTO _!! ILl (_L ..........
120 VAC POWER SOURCE _ I 24VACLEADS
@
SWITCH POSITION
BYPASS
MODELS
NUMCCLFP1518
HUMBBLFP1518
P110-LFP1518
BYPASS HUMIDIFIER WIRING DIAGRAM
DiagramC
FOROPERATIONDURING
"HEATCALL" ONLY
24VAC Cj _
TERMINALS
ONFURNACE HUM--
HUMIDIFIER Q
HUMIDITRAC CONTROL
WIRING TERMINALS
'll'
)_!_ _ A_
OUTDOOR
TEMPERATURE
SENSOR
/ / 24VAC
_l l SOLENOIDVALVE
¢-,._ LEADS
HUMIDITRAC CONTROL SWITCH POSITION
WIRING TERMINALS BYPASS
Ii R24vC Ii FHq II rOOT1 Ii
DiagramD
FOROPERATIONWHEN
BLOWERIS ENERGIZED _. OUTDOOR
120 VAC 4_11_ / / / _ TEMPERATURE
"EAC" ,.....UIF._ / / SENSOR
TERMINALS TRANSFORMER I I
ON FURNACE (F'ELD SUPPUED) / /24VAC
J .SDLENDIDVALVE
LEADS
NOTE:CONNECTSOLENOID VALVETO HOT
HUMIDIFIER _ _(i_IRFCI(N
WATER IFHUMIDIFIER WILL BE OPERATED
DENT OFHEATING CALLS. 90-1120
tlumidifier ControlTroubleshootingGuide
Appliesto both Automaticand Manual Operationunless indicatedotherwise.
SYMPTOM TROUBLESHOOTING PROCEDURE
Humidifier does
not operate in
"Test" mode
*Make surefurnace blower is operating and thermostat is calling for heat.
* Make surethe OutdoorTemperature Sensor is connected to the "ODT" terminals ofthe control. (For Manual Operation,
make sure Manual Mode Resistor
Caseis in place.)
*Check wiring diagram for correct
Humidifier Control installation.
*Check voltage at Humidifier Control
"R" and "C" terminals. Voltage
should be 22VACminimum- 30VAC
maximum.
*Check Current Sensing Relay
(if used) for correct installation (see
Current Sensing Relayinstructions).
Do not use Current Sensing Relayin
transformer circuit or "R" and "C°'
circuit of Humidifier Control. Current
Sensing Relay isto be used in the
"H" circuit only.
*In"Test" mode, humidifier will
operate for 1minute only. DO NOT
LEAVEIN TESTMODEAS
HUMIDIFIERWILL NOTOPERATE
WARNING
Sharpedges onthe opening may causecuts. Usecarewhen cutting the plenum opening
and installing the Humidifier Control.
CAUTION
* Donot mount Humidifier Controlon supply plenum OFduct. Theunit will not withstand
supply temperatures and will malfunction!
* When installing Humidifier Control on counterflow furnaces, ensure blower continues
to run after a heat call issatisfiedto eliminate hightemperatures from damagingthe
Humidifier Control.
* Donot mount HumidifierControldownstream of the bypassoutlet. Falsehumidity
conditions will causehumidifier to operate incoFrectly.
CUTOUTTEMPLATEALONGEDGES.1.
2.
3.
4.
5.
PLACETEMPLATEON THERETURNPLENUMUPSTREAMOF(BEFORE)THE
HUMIDIFIERCONNECTION.
TRACEOUTSIDEEDGESOFTEMPLATE.
REMOVETEMPLATEAND ACCURATELYCUTPLENUMOPENING.
USING4SHEETMETALSCREWS,INSTALLHUMIDIFIERCONTROLIN PLENUMOPENING.
*Make sure saddle valve is open.........................................................................................................................................

SYMPTOM
HumidifierControlTroubleshootingGuide
Appliesto both Automaticand Manual Operationunless indicatedotherwise.
TROUBLESHOOTINGPROCEDURE
"Change Humidifier Pad" •Callyour installerto have your Humidifier Pad changed, or visit your installerto purchase a new Humidifier Pad.
Indicator is lit. Followthe instructions on the Humidifier Pad box.
Humidifier operates only
in "Test" mode •If outdoor temperature isgreater than 60°For less than -30°F,the Humidifier Control will
only operate inthe "Test" mode. (For One Minute)
•Ifthe humidity level inthe home ishigherthan the knobsetting, the Humidifier Control
will not operate the Humidifier.
•Checkthe resistance of the sensor by removing the leads ofthe OutdoorTemperature
Sensorfrom the terminals and measuring the resistance across the wires with an
ohmmeter. Compare reading to outdoor temperature inTable 1.(For Manual Operation,
verify that resistance across the leads of Manual Mode Resistor Case isbetween 44,000
and48,000ohms).
•Make sure the OutdoorTemperature Sensor is mounted completely outside the house
onthe North, East,or West side ofthe house and out of direct sunlight. (Automatic
Mode Only)
•If Outdoor Temperature Sensor ismounted infresh air intakeduct, make surethe probe
isno morethan 36 inchesfrom the outside wall. (Automatic Mode Only)
•Make sure the OutdoorTemperature Sensor is located at least 3feet away from all
exhaust vents. (Automatic Mode Only)
TABLE 1
Outdoor Resistance
Temperature k_
-30°F 230.6
-20°F 163.8
-10°F 117.6
0°F 85.4
10°F 62.6
20°F 46.3
30°F 34.6
40°F 26.1
50°F 19.9
60°F 15.3
70°F 11.9
80°F 9.4
90°F 7.4
100°F 5.9
Humidifier operates •Ifthe humidity levelin the home islessthan the knobsetting, the Humidifier Controlwill operate the Humidifier until
constantly the humidity level is higher than the knob setting.
•Inthe "Test" mode, verify unit will operate for approximately one minute.
•Checkthe resistance ofthe Outdoor Temperature Sensor asinstructedabove.
•Make sure the Outdoor Temperature Sensor ismounted completely outside the house onthe North, East,or West
side of the houseand out of direct sunlight. (Automatic Mode Only).
•Rotatethe Humidifier Control knob counterclockwise to the "Off" position, and observe whether the humidifier turns
off. Ifthe humidifier still operates in the "Off" position, _erformthe following:
1. Checkwiring diagram for correct Humidifier Control Installation.
2. Removewires from Humidifier Control's "H" terminals. If Humidifier continues to operate, replace solenoid valve.
Humidifier or Humidifier •Checkfor steady 22VAC- 30VACwith voltmeter.
Control "chatters" or •Make sure Outdoor Temperature Sensor wiring is not run alongside wires carrying high voltage (120VACor higher).
clicks ON and OFFrapidly (Automatic Mode Only)
Red Diagnostic Light is on •
(See FigureH) .Checkthat the wiring iscorrect.
Measure the resistance of the Outdoor Temperature Sensor by
removingthe leads from the terminal and measuring the resistance
across the wires with an ohmmeter. Confirmthe reading with the
temperature inTable 1.(ForManual Operation, verify that the
resistance across the leads ofthe Manual Mode Resistor Caseis
between 44,000and 48,000ohms).
RED
DIAGNOSTIC
Form/Catalog:IM-AHC-03
ReplacesIM-AHC-02
© 2012CAC/BDP
7310West Morris St.
Indianapolis,IN46231
10009851 3.12
........................................................................................................................................ B2205740A
Other Carrier Control Panel manuals

Carrier
Carrier Touch Pilot Junior User manual

Carrier
Carrier SmartVu control User manual

Carrier
Carrier SmartVu control User manual

Carrier
Carrier Infinity SYSTXCCUID01-B User manual

Carrier
Carrier 2X-A/2X User manual

Carrier
Carrier INFINITY ZONING CONTROL User manual

Carrier
Carrier Aritech Reliance XR Series Installation guide

Carrier
Carrier Touch Pilot 30XW-V User manual