manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CDN
  6. •
  7. Scale
  8. •
  9. CDN SD0204 User manual

CDN SD0204 User manual

Model: SD0204
DIGITAL HIGH PRECISION SCALE
2 POUNDS/1 KILOGRAM by pounds:ounces and kilograms.grams
FOR PRECISE & GENERAL WEIGHING
•Precise to 0.01 oz/0.1 g
•NSF®Certied
•Small prole
•Tare function
•Hold mode
•Field calibration
•Removable stainless steel platform
•Selectable units
•Overload indication
•Battery status indication
•On/off button
•Auto-off after 2 minutes; disabled when
the AC adapter is used
•Food-safe ABS plastic with BioCote®
•Platform Size:
5.35 W x 5.35 L (in)/13.6 W x 13.6 L (cm), removable
•Resolution: 0.01 oz, 0.1 g
•Product Dimensions:
5.90 W x 1.75 H x 7.87 D (inches)/
15.0 W x 4.45 H x 20.0 D (cm)
•AC Adapter:
100-240VAC 50/60Hz input, 9V DC (500mA) output,
included
•Two AAA alkaline batteries (WERCSmart) included
Note: Clean the scale before each use.
Important: DO NOT IMMERSE IN LIQUID.
Note: In the following instructions, names of the control
buttons are shown in CAPS. Function information that
appears on the display is shown in BOLD CAPS.
BATTERY INSTALLATION
Replace battery when LCD becomes dim. bAtt
appears on the display for 2 seconds before turning
off when the batteries need to be replaced.
1. Power off the unit before installing the batteries.
2. Remove battery cover on the bottom by pressing
the latch toward the battery cover and lifting up.
3. Install two AAA alkaline batteries observing
polarity shown in compartment.
4. Replace the battery cover until it clicks shut.
POWER ADAPTER
Before using the external power adapter, make sure
that the printed voltage complies with the local
voltage.
Note: Use only an original CDN power adapter (AD-AC3302). The
use of another adapter is subject to approval by CDN.
1. Insert the adapter plug into the jack in the rear of
the scale.
2. To turn the scale on, press the ON/OFF button
as described in Section A: On/Off. The scale will
remain on until turned off.
Note: When the power adapter is plugged in, the auto-off
feature is disabled.
OPERATING INSTRUCTIONS
Place the scale gently on a hard and at surface and
make sure it is steady before use to obtain accurate
measurements.
A. On/Off
1. Press the ON/OFF button to turn on. The display
ashes ––– and then returns to zero.
2. Press and hold the ON/OFF button for
2 seconds to turn off.
B. Auto Off
The scale automatically turns off after 2 minutes
of inactivity when the AC adapter is not plugged in.
Note: Auto-off is disabled when the AC adapter is used.
Tel 800 338-5594 Fax 800 879-2364 Web CDNmeasurement.com
2
C. Unit Selection
1. Press the UNIT button to select the desired unit.
The display switches between lb:oz and kg.g.
2. oz appears on the display when the weight is
less than 1 lb. Otherwise, both lb and oz appear
on the display.
3. gappears on the display when the weight is less
than 1 kg. Otherwise, kg appears on the display.
D. Hold Mode
1. Press and hold the HOLD button for 2 seconds.
HOLD ashes on the display for 15 seconds to
allow enough time to place an item on the scale.
Note: If no item is placed on the scale, the scale will exit
Hold Mode and return to Weighing Mode.
2. When the item is placed on the scale, the
item’s weight and HOLD appear on the display
for 15 seconds.
3. When the hold time is over, the scale exits
Hold Mode automatically and returns to
Weighing Mode.
Note: During Hold Mode all buttons are locked.
E. Weighing Mode
1. Press the ON/OFF button to turn on. The display
ashes ––– and then returns to zero.
2. Place an item on the scale platform. The weight
of the item appears on the display within
1 second after the item is stable.
Note: The minimum measurable weight is 0.02 oz/0.5 g.
F. Tare
The tare function resets the scale display to zero
in order to measure only the weight of an item.
It is frequently used to subtract the weight of
containers.
1. When the scale is on, place a container on
the platform.
2. Press the TARE button to reset the display
to zero. The display ashes ––– and then returns
to zero.
3. Place the item into the container or directly on
the scale platform. The weight of only the last
item added will appear on the display.
4. Continue to repeat steps 2. and 3. to measure
the respective weights of additional items.
5. To clear the tare, remove all items from the
platform and press the TARE button. The display
is reset to zero.
G. Field Calibration
1. When scale is off, press and hold the ON/OFF
button until ––– is displayed.
2. Press the UNIT button 3 times within two
seconds.
3. Press and hold the UNIT button until 0appears
on the display. The 5-digit internal code value
then appears on the display.
4. Press the UNIT button again. The software
version and then 1000.0 g appears on
the display.
Note: To change the calibration units to grams or pounds,
press the UNIT button. 1 kg (WT01) calibration weights are
available from CDN.
5. Put a 1 kg calibration weight in the center of the
platform. The display becomes blank briey and
then PASS appears on the display for 3 seconds
if the calibration is successful. The scale has
been calibrated and is ready for use.
H. Battery Status
bAtt:replace battery with two AAA alkaline cells.
The scale turns off automatically after 2 seconds.
I. Error Messages
1. EEEE indicates an overload when the item
being measured exceeds the capacity of the
scale. Immediately remove the overweight item
to avoid causing permanent damage to your
scale. The scale turns off automatically after
2 seconds.
2. Err2 indicates an initialization problem.
The scale turns off automatically after
2 seconds. Turn on the scale again. If the
problem persists, please contact CDN.
Note: Clean the scale platform before each use. The
stainless steel removable platform is dishwasher safe; the
removable plastic platform base is not dishwasher safe.
Note: Replacement removable platform, AC adapter and
1 kg calibration weights available.
CE Note: This device could be sensitive to electrostatic
discharge. If electrostatic discharge or malfunctioning
occurs, please re-install the battery to reset this unit.
3
USAGE GUIDELINES
• Scales are precision instruments and must be
handled with extreme care.
• Battery technology works best at room
temperature. Do not leave the scale in cold
rooms, refrigerators or freezers for extended
periods of time.
• Place the scale gently on a hard and at surface
and make sure it is steady before use.
• The minimum capacity of the scale is 0.02 oz/0.5 g.
• The maximum capacity of the scale is 2 lb/1 kg,
which is the capacity before using the tare function.
• Do not place overweight items on the scale.
• Do not place hot items directly on the scale
platform. They can distort the display. Rather, tare
a baking sheet at room temperature and then place
the hot item on it.
• Store the scale in a position that keeps it free from
any load bearing weight. Storing the scale with
pressure on the load cells can distort the weight
measurements over time.
• Hold the scale from the bottom when moving.
CARE OF YOUR PRODUCT
• Do not submerge any part of the scale in water.
• Wipe clean with a damp cloth.
• Store the scale at room temperature between
32 to 104°F/0 to 40°C.
PRECAUTIONS
• Keep the scale and/or battery away from children.
• Do not clean the scale with abrasive or corrosive
compounds, which may scratch the surface and
corrode the electronic circuits.
• Do not subject the scale to excessive force, shock,
dust, temperature or humidity, which may result in
malfunction, shorter electronic life span, damaged
battery and/or distorted parts.
• Do not tamper with the scale’s internal
components. Doing so will invalidate the warranty
and may cause unnecessary battery damage and/
or distorted parts.
• Do not subject the scale to excessive exposure
to direct sunlight.
• The unit is not waterproof — do not immerse it in
any liquid, which will result in faulty measurements.
• To avoid deformation, do not place the unit in
extreme temperatures.
• Always read the user manual thoroughly
before operating.
SPECIFICATIONS
Measurement Range 2 lb/1 kg
Unit of Measure lb:oz, kg.g
Resolution 0.01 oz, 0.1 g
Operating Range 32°F~104°F/0°C~40°C ≤90% RH
Water Resilience IP54 – dust protected & splashing of
water
Accuracy 500 g ±1.5 g; 1000 g ±3 g
Power Supply Two AAA alkaline batteries
(WERCSmart); AC Adapter:
100-240VAC 50/60Hz input,
9V DC (500mA) output
Platform Dimensions
5.35 W x 5.35 L (in)/13.6 W x 13.6 L (cm),
removable
Product Dimensions 7.87 W x 1.75 H x 5.90 D (inches)/
20.0 W x 4.45 H x 15.0 D (cm)
Weight 18.5 oz / 524 g (including battery)
Accessories Removable stainless steel platform
(AD-PF0502), power adapter
(AD-AC3302), 1 kg calibration weight
(WT01)
© 08-2022 CDN Made in China CD9999407en - 8/22
Antimicrobial properties are
built-in to inhibit the growth of
bacteria that may affect this
product. According to EPA
guidelines we cannot claim that
the antimicrobial properties in this
product protect users or others
against bacteria, viruses, germs,
or other disease organisms.
This product does not protect
users or others against food-borne bacteria. Always clean and
wash this product thoroughly before and after each use.
The information in this document has been reviewed and is believed to
be accurate. However, neither the manufacturer nor its afliates assume
any responsibility for inaccuracies, errors or omissions that may be
contained herein. In no event will the manufacturer or its afliates be
liable for direct, indirect, special, incidental or consequential damages
arisen by using this product or resulting from any defect/omission in
this document, even if advised of the possibility of such damages.
The manufacturer and its afliates reserve the right to make
improvements or changes to this document and the products and
services described at any time, without notice or obligation.
1-Year Limited Warranty: Any instrument that proves
to be defective in material or workmanship (excluding
batteries) within one year of original purchase will be
repaired or replaced without charge upon receipt of the unit
prepaid at: CDN, PO Box 10947, Portland, OR 97296-0947
USA. This warranty does not cover damage in shipment
or failure caused by failure to adhere to the accompanying
instructions, inadequate maintenance, normal wear
and tear, tampering, accident, misuse, unauthorized
modication, obvious carelessness or abuse. CDN
shall not be liable for any consequential or incidental
damages whatsoever.
For more detailed information on our
products, please visit CDNmeasurement.com
or call 800-338-5594.

Other CDN Scale manuals

CDN ProAccurate SD2210X User manual

CDN

CDN ProAccurate SD2210X User manual

CDN SM2201 User manual

CDN

CDN SM2201 User manual

CDN SD1106 User manual

CDN

CDN SD1106 User manual

CDN SD1104 User manual

CDN

CDN SD1104 User manual

CDN SD0202-R User manual

CDN

CDN SD0202-R User manual

CDN SD0602 User manual

CDN

CDN SD0602 User manual

CDN SD1102 User manual

CDN

CDN SD1102 User manual

CDN SD2204 User manual

CDN

CDN SD2204 User manual

CDN ProAccurate SD5502 User manual

CDN

CDN ProAccurate SD5502 User manual

CDN SD1110 User manual

CDN

CDN SD1110 User manual

CDN SD0202 User manual

CDN

CDN SD0202 User manual

CDN SDC0602 User manual

CDN

CDN SDC0602 User manual

CDN ProAccurate SD1110X User manual

CDN

CDN ProAccurate SD1110X User manual

CDN SM1101 User manual

CDN

CDN SM1101 User manual

CDN SD750 User manual

CDN

CDN SD750 User manual

Popular Scale manuals by other brands

Balance KH 391 Operating and safety instructions

Balance

Balance KH 391 Operating and safety instructions

Redmond RS-712 Instructions for use

Redmond

Redmond RS-712 Instructions for use

Giorgio Bormac BL 224 user manual

Giorgio Bormac

Giorgio Bormac BL 224 user manual

Clatronic PW 3111 FA Instruction manual & guarantee

Clatronic

Clatronic PW 3111 FA Instruction manual & guarantee

Taylor 3879 instruction manual

Taylor

Taylor 3879 instruction manual

Kogan KADIGTHSCAA user manual

Kogan

Kogan KADIGTHSCAA user manual

Terraillon MASTER COACH quick start guide

Terraillon

Terraillon MASTER COACH quick start guide

Marta MT-1634 user manual

Marta

Marta MT-1634 user manual

UFESA BE0906 instruction manual

UFESA

UFESA BE0906 instruction manual

Ironton 30737 user manual

Ironton

Ironton 30737 user manual

Taylor 7553 instruction manual

Taylor

Taylor 7553 instruction manual

Beurer BG 13 Instructions for use

Beurer

Beurer BG 13 Instructions for use

Salter Brecknell PS250 User instructions

Salter Brecknell

Salter Brecknell PS250 User instructions

TREVIDEA G3 Ferrari MAGICA user manual

TREVIDEA

TREVIDEA G3 Ferrari MAGICA user manual

Beurer PS 45 BMI Instructions for use

Beurer

Beurer PS 45 BMI Instructions for use

Fulcrum DRX-200 Quick reference guide

Fulcrum

Fulcrum DRX-200 Quick reference guide

KERN VHM_M operating instructions

KERN

KERN VHM_M operating instructions

Soehnle FT 4 operating instructions

Soehnle

Soehnle FT 4 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.