manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CDN
  6. •
  7. Scale
  8. •
  9. CDN SDC0602 User manual

CDN SDC0602 User manual

Other CDN Scale manuals

CDN SD0202-R User manual

CDN

CDN SD0202-R User manual

CDN SD1110 User manual

CDN

CDN SD1110 User manual

CDN SD0202 User manual

CDN

CDN SD0202 User manual

CDN SD0602 User manual

CDN

CDN SD0602 User manual

CDN SD1102 User manual

CDN

CDN SD1102 User manual

CDN SM2201 User manual

CDN

CDN SM2201 User manual

CDN SD0204 User manual

CDN

CDN SD0204 User manual

CDN SD1106 User manual

CDN

CDN SD1106 User manual

CDN ProAccurate SD2210X User manual

CDN

CDN ProAccurate SD2210X User manual

CDN SM1101 User manual

CDN

CDN SM1101 User manual

CDN SD750 User manual

CDN

CDN SD750 User manual

CDN ProAccurate SD1110X User manual

CDN

CDN ProAccurate SD1110X User manual

CDN ProAccurate SD5502 User manual

CDN

CDN ProAccurate SD5502 User manual

CDN SD2204 User manual

CDN

CDN SD2204 User manual

CDN SD1104 User manual

CDN

CDN SD1104 User manual

Popular Scale manuals by other brands

KERN MCC-M operating instructions

KERN

KERN MCC-M operating instructions

Little Balance SB MECA 8113 user manual

Little Balance

Little Balance SB MECA 8113 user manual

Fitbit Zip Aria Wi-Fi Smart Scale user manual

Fitbit Zip

Fitbit Zip Aria Wi-Fi Smart Scale user manual

KERN MPU 250K100 operating instructions

KERN

KERN MPU 250K100 operating instructions

Steinberg Systems SBS-PF-200 user manual

Steinberg Systems

Steinberg Systems SBS-PF-200 user manual

Total TP2000 user guide

Total

Total TP2000 user guide

A&D HL-200i operating instructions

A&D

A&D HL-200i operating instructions

OHAUS Courier 3000 user guide

OHAUS

OHAUS Courier 3000 user guide

Scarlett SC-KS57P97 instruction manual

Scarlett

Scarlett SC-KS57P97 instruction manual

BASETech LS-40S operating instructions

BASETech

BASETech LS-40S operating instructions

SR Instruments SR Scales SR565i-H Operating and service manual

SR Instruments

SR Instruments SR Scales SR565i-H Operating and service manual

Gallet PEP 301ART instruction manual

Gallet

Gallet PEP 301ART instruction manual

AWS ZEO-50 user manual

AWS

AWS ZEO-50 user manual

Gima Glass Body Fat Analyzer Use and maintenance book

Gima

Gima Glass Body Fat Analyzer Use and maintenance book

Seca 374 user manual

Seca

Seca 374 user manual

EDLUND BBPZ-20 quick start guide

EDLUND

EDLUND BBPZ-20 quick start guide

TEC TEC SL59 SERIES owner's manual

TEC

TEC TEC SL59 SERIES owner's manual

Alecto ACW-40 user manual

Alecto

Alecto ACW-40 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Model: SDC0602
COFFEE SCALE & TIMER
3 KILOGRAMS/6.5 POUNDS/3 LITERS by grams, ounces and milliliters
Counts 100 minutes by minutes & seconds
FOR COFFEE, TEA, SPICES & OTHER
SMALL QUANTITIES
•Precise to 0.1 g/0.005 oz/0.1 ml
•Tare function
•Selectable units
•Backlit digits
•Button feedback beep
•Stability indication
•Overload indication
•Timer counts up
•Stop & restart
•Low battery indication
•Battery charging indication
•On/off button
•Auto-off after 1 minute
•ABS plastic housing
•Polycarbonate polymer platform (heat resistant
up to 275°F/135°C)
•Platform Size:
5.1 W x 4.7 L (in)/13 W x 12 L (cm)
•Resolution: 0.1 g, 0.005 oz, 0.1 ml
•Product Dimensions:
5.1 W x 0.87 H x 5.9 D (inches)/
13.0 W x 2.22 H x 15.0 D (cm)
•Built-in rechargeable lithium-ion battery and
USB charging cable included
Note: Clean the scale before each use.
Important: DO NOT IMMERSE IN LIQUID.
Note: In the following instructions, names of the control
buttons are shown in CAPS. Function information that
appears on the display is shown in BOLD CAPS.
CHARGING THE BATTERY
0:00 Lo appears on the display when battery status
is low and needs to be charged. The battery is built-in
and does not need to be replaced.
1. Insert the USB-C plug into the jack on the top side
of the scale. Insert the USB-A plug into a USB-A
power source.
Note: Use only an original CDN charging cable (AD-SDC0602).
The use of another cable is subject to approval by CDN.
2. —ashes on the display while charging. Allow the
scale to charge for 2-5 hours.
3. FULL appears on the display when the battery
is fully charged. The scale will then operate
continuously for approximately 10 hours.
4. Unplug the cable and turn the scale on as
described in Section A: On/Off.
OPERATING INSTRUCTIONS
Place the scale gently on a hard and at surface and
make sure it is steady before use to obtain accurate
measurements. This scale noties users with an
audible alert (“beep”) when any button is touched.
A. On/Off
1. Touch and hold the ON/OFF button for
2 seconds to turn on. The display will show all
segments and a “beep” will sound. The display
then returns to zero.
2. Touch and hold the ON/OFF button for
2 seconds to turn off.
B. Auto Off
The scale automatically turns off after 1 minute
of inactivity.
C. Unit Selection
1. Touch and hold the UNIT button for 2 seconds
to select the desired unit. The display cycles
through g, oz and ml.
Tel 800 338-5594 Fax 800 879-2364 Web CDNmeasurement.com
2
D. Weighing Mode
1. Touch and hold the ON/OFF button for
2 seconds to turn on. The display will show all
segments and a “beep” will sound. The display
then returns to zero.
2. Place an item on the scale platform. The weight
of the item appears on the display within
1 second after the item is stable.
Note: The minimum measurable weight is 1 g/0.05 oz/1 ml.
E. Tare
The tare function resets the scale display to zero
in order to measure only the weight of an item.
It is frequently used to subtract the weight
of containers.
1. When the scale is on, place a container on
the platform.
2.
Touch the TARE button to reset the display to zero.
3. Place the item into the container or directly on
the scale platform. The weight of only the last
item added will appear on the display.
4. Continue to repeat steps 2. and 3. to measure
the respective weights of additional items.
5. To clear the tare, remove all items from the
platform and touch the TARE button. The display
is reset to zero.
F. Timer
1. Touch the TIMER button to begin the count up.
Note: The timer counts up to a maximum of 99 minutes and
59 seconds and then turns off automatically.
2. Touch the TIMER button to interrupt the count.
3.
Touch the TIMER button again to resume the count.
4. To clear the display, touch the TIMER button
twice to reset the display to 0:00.
G. Battery Status
0:00 Lo indicates when power is lower than 3.0V.
Charge the battery.
H. Error Messages
1. 0:00 EEEEE indicates an overload when the
item being measured exceeds the capacity of
the scale. Immediately remove the overweight
item to avoid causing permanent damage to
your scale.
2. 88:88 UnSt indicates that the scale is unstable.
Place the scale gently on a hard and at surface
and make sure it is steady before turning on
without any items on it.
Note: Clean the scale platform before each use.
CE Note: This device could be sensitive to electrostatic
discharge. If electrostatic discharge or malfunctioning
occurs, please re-install the battery to reset this unit.
3
USAGE GUIDELINES
• Scales are precision instruments and must be
handled with extreme care.
• Battery technology works best at room
temperature. Do not leave the scale in cold
rooms, refrigerators or freezers for extended
periods of time.
• Place the scale gently on a hard and at surface
and make sure it is steady before use.
•
The minimum capacity of the scale is 1 g/0.05 oz/1 ml.
• The maximum capacity of the scale is
3 kg/6.5 lb/3 L, which is the capacity before using
the tare function.
• Do not place overweight items on the scale.
• Do not place hot items directly on the scale
platform in excess of 275°F/135°C. They can distort
the platform. Rather, tare a sheet pan at room
temperature and then place the hot item on it.
• Store the scale in a position that keeps it free from
any load bearing weight. Storing the scale with
pressure on the load cells can distort the weight
measurements over time.
• Hold the scale from the bottom when moving.
CARE OF YOUR PRODUCT
• Do not submerge any part of the scale in water.
• Wipe clean with a damp cloth.
• Store the scale at room temperature between
41 to 104°F/5 to 40°C.
PRECAUTIONS
• Keep the scale and/or battery away from children.
• Do not clean the scale with abrasive or corrosive
compounds, which may scratch the surface and
corrode the electronic circuits.
• Do not subject the scale to excessive force, shock,
dust, temperature or humidity, which may result in
malfunction, shorter electronic life span, damaged
battery and/or distorted parts.
• Do not tamper with the scale’s internal
components. Doing so will invalidate the warranty
and may cause unnecessary battery damage, risk
of explosion and/or distorted parts.
• Do not subject the scale to excessive exposure
to direct sunlight.
• The unit is not waterproof — do not immerse it in
any liquid, which will result in faulty measurements.
• To avoid deformation, do not place the unit in
extreme temperatures.
• Always read the user manual thoroughly before
operating.
SPECIFICATIONS
Measurement Range 3 kg / 6.5 lb / 3 L
Unit of Measure g, oz, ml
Resolution 0.1 g, 0.005 oz, 0.1 ml
Minimum Weight 1 g, 0.05 oz, 1 ml
Operating Range 41°F~104°F/5°C~40°C ≤90% RH
Accuracy Central loading 2 kg ±6g; 3 kg ±9g
Power Supply One 3.7V 1000mAh built-in
rechargeable battery; Charging cable:
19.7"/0.5 m USB-A to USB-C cable
Platform Dimensions 5.1 W x 4.7 L (in)/13 W x 12 L (cm)
Product Dimensions 5.1 W x 0.87 H x 5.9 D (inches)/
13.0 W x 2.22 H x 15.0 D (cm)
Weight 8.1 oz / 230 g (including battery)
Accessories USB charging cable (AD-SDC0602)
© 08-2022 CDN Made in China CD9999408en - 8/22
The information in this document has been reviewed and is believed to
be accurate. However, neither the manufacturer nor its afliates assume
any responsibility for inaccuracies, errors or omissions that may be
contained herein. In no event will the manufacturer or its afliates be
liable for direct, indirect, special, incidental or consequential damages
arisen by using this product or resulting from any defect/omission in
this document, even if advised of the possibility of such damages.
The manufacturer and its afliates reserve the right to make
improvements or changes to this document and the products and
services described at any time, without notice or obligation.
1-Year Limited Warranty: Any instrument that proves
to be defective in material or workmanship (excluding
batteries) within one year of original purchase will be
repaired or replaced without charge upon receipt of the unit
prepaid at: CDN, PO Box 10947, Portland, OR 97296-0947
USA. This warranty does not cover damage in shipment
or failure caused by failure to adhere to the accompanying
instructions, inadequate maintenance, normal wear
and tear, tampering, accident, misuse, unauthorized
modication, obvious carelessness or abuse. CDN
shall not be liable for any consequential or incidental
damages whatsoever.
For more detailed information on our
products, please visit CDNmeasurement.com
or call 800-338-5594.