93984 series thermometer is a non-contact infrared thermometer. Simply
aim the thermometer at the target and press the ‘Scan’ button to display
the surface temperature.
Laser Information:
By partially pressing the ‘Scan’ button, the device will begin to
measure the temperature of the target. When the ‘Scan’ button is
completely depressed, the laser will operate.
CAUTION!
1. NOT FOR FOOD SAFETY OR MEDICAL USE.
2. CONTAINS SMALL PARTS. KEEP OUT OF
REACH OF CHILDREN.
To change from ‘°C’ to ‘°F’ or from ‘°F’ to ‘°C’, first turn the instrument on
by pressing the ‘Scan’ button. Then press the ‘Mode’ button four times,
the ‘°C’ or ‘°F’ symbol will flash. Press the ‘Scan’ button to change to
scale, then press the ‘Scan’ button to confirm the mode.
MINIMUM OR MAXIMUM MODE
To utilize the minimum or maximum mode: first turn the instrument on by
pressing the ‘Scan’ button. Then press the ‘Mode’ button once for
minimum or twice for maximum function. The ‘MIN’ or ‘MAX’ icon will
flash, then press the ‘Scan’ button to confirm the minimum or maximum
mode. The unit will display the minimum or maximum reading only.
LOCK MODE
The lock mode is particularly useful for continuous monitoring of
temperatures.
To utilize the unit’s LOCK mode: first turn the instrument on by pressing
the ‘Scan’ button, then press the ‘Mode’ button three times for the lock
mode function. The lock icon will flash, then press the ‘Scan’ button to
e. It will continuously display the temperature
the ‘Scan’ button is pressed again.
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
「」
「」
‘Hi’ or ’Lo’ is displayed when the temperature being
measured is outside of the range of the instrument,
‘Hi’ when higher than +250°C (482°F) and ‘Lo’ when
lower than –33°C (-67°F).
「 」
「」
‘Er2’ is displayed when the unit is exposed to rapid
changes in the ambient temperature. ‘Er3’ is
displayed when the ambient temperature EXCEEDS
0°C (32°F) OR +50°C (122°F). In both cases you
should allow plenty of time (minimum 30 minutes) for
the unit stabilize to the working/room temperature.
「」
For all other error messages it is necessary to reset
the unit. To reset it, turn the instrument off, remove
the battery and wait for a minimum of one minute,
reinsert the battery and turn on. If the error message
remains please contact the Service Department for
further assistance.
BATTERIES
The unit has two separate batteries. The battery closer to the side of the
laser beam output is for laser operation only. The other battery is
designated for temperature measurements. The unit can still measure
temperature properly, even without the laser battery.
This item incorporates visual low battery indication (for the lower battery)
as follows:
°C OR °F MODE
confirm the lock ‘Scan’ mod
for up to 60 minutes or until
‘Battery OK’:
measurements
are possible
‘Battery Low’: battery needs
to be replaced,
measurements are possible
‘Battery Exhausted’:
measurements are
not possible
BATTERY REPLACEMENT
When the ‘Low Battery’ icon indicates the battery is low, the battery
should be replaced immediately with a CR2032 lithium cell. The battery
is located under the twist cover at the rear of the thermometer. Please
note: It is important to turn the instrument off before replacing the battery
otherwise the unit may malfunction.
Dispose of used battery properly and keep away from children.
STORAGE & CLEANING
The sensor lens is the most delicate part. The lens should be kept clean
at all times, care should be taken when cleaning the lens using only a
soft cloth or cotton swab with water or medical alcohol, allowing the lens
to fully dry before using. Do not submerge any part of this item. This
item should be stored at room temperature between -20 to +65°C (-4 to
+149°F).
SPECIFICATION
Measurement Range -33 to +250°C (-27~482°F)
Operating Range 0~50°C (32~122°F)
Accuracy
(Tobj=15-35°C,Tamb=25°C) +/-1.0°C (1.8°F)
Accuracy
(Tobj=-33~250
o
C, Tamb=23±3
o
C)
±2% of reading or 2°C (4°F) whichever is
greater
Resolution (-9.9~199.9°C) 0.1°C / 0.1°F (switchable)
Response Time (90%) 1 second
Distance: Spot 6:1 optics ratio
Emissivity 0.95 fixed
Battery Life Typ. 40hr, min 30hr
(auto power off after 15 seconds)
Battery CR2032 (for Laser, 2pcs required)
Dimensions 22.5 x 50 x 103mm
Weight 65 grams including batteries
EMC/RFI
Readings may be affected if the unit is operated within radio frequency
electromagnetic field strength of approximately 3 volts per meter, but the
performance of the instrument will not be permanently affected.
There are no user serviceable parts inside the instrument. Any
attempted repair by unqualified persons voids the warranty.
3491 Mission Oaks Blvd., Camarillo, CA
93011
Visit our Web site at:
http://www.harborfreight.com

Other Centech Thermometer manuals

Centech 91778 User manual

Centech

Centech 91778 User manual

Centech 96451 User manual

Centech

Centech 96451 User manual

Centech 60725 Assembly instructions

Centech

Centech 60725 Assembly instructions

Centech 90380 Quick reference guide

Centech

Centech 90380 Quick reference guide

Centech 96451 User manual

Centech

Centech 96451 User manual

Centech 92350 User manual

Centech

Centech 92350 User manual

Centech CEN-TECH 94233 User manual

Centech

Centech CEN-TECH 94233 User manual

Centech Pocket Thermometer User manual

Centech

Centech Pocket Thermometer User manual

Centech 92242 Quick reference guide

Centech

Centech 92242 Quick reference guide

Popular Thermometer manuals by other brands

Omega LDP-144 Series user guide

Omega

Omega LDP-144 Series user guide

Medisana ThermoDock instruction manual

Medisana

Medisana ThermoDock instruction manual

BROWIN 185909 Operation manual

BROWIN

BROWIN 185909 Operation manual

Tesla TSL-HC-UFR102 user manual

Tesla

Tesla TSL-HC-UFR102 user manual

VivaLNK FEVER SCOUT VV200 Instructions for use

VivaLNK

VivaLNK FEVER SCOUT VV200 Instructions for use

ICI HOTSPOT user manual

ICI

ICI HOTSPOT user manual

Bresser ClimaTemp instruction manual

Bresser

Bresser ClimaTemp instruction manual

Char-Broil 4885637 user manual

Char-Broil

Char-Broil 4885637 user manual

GrillEye Pro+ Quick user guide

GrillEye

GrillEye Pro+ Quick user guide

RKC INSTRUMENT LTM-100 instruction manual

RKC INSTRUMENT

RKC INSTRUMENT LTM-100 instruction manual

Greenlee THH-100 instruction manual

Greenlee

Greenlee THH-100 instruction manual

LaserLiner ThermoSpot XP manual

LaserLiner

LaserLiner ThermoSpot XP manual

JAVAC RT-905 Safety instructions & operation manual

JAVAC

JAVAC RT-905 Safety instructions & operation manual

ADC Adtemp 415FL Instructions for use

ADC

ADC Adtemp 415FL Instructions for use

JMB 53794B instruction manual

JMB

JMB 53794B instruction manual

AccuMac AM8060 user guide

AccuMac

AccuMac AM8060 user guide

Taylor 1442 instruction manual

Taylor

Taylor 1442 instruction manual

TFA 30.1009 operating instructions

TFA

TFA 30.1009 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.