Centsys D3 User manual

D3, D5 and A10 User guide
TM
TM
TM
DOMESTIC AND
INDUSTRIAL
SLIDING GATE
OPERATORS

The CENTSYS D3 and D5 Version 3 sliding gate operators are manufactured with extreme care,
thoroughly inspected and tested. The operators are only guaranteed against faulty materials or
workmanship for a period of 24 months from the invoice date of the operator, or 26 months from the
manufacturing date (as shown on the serial number label of the operator), whichever expires first.
The guarantee will cover the repair or replacement at our discretion of such faulty materials or parts
free of charge, provided that the equipment is returned to our workshop.
The guarantee only applies to the gearbox, motor, controller and other components specific to the
operator. Peripheral components such as the charger, battery and other ancillary devices connected
to the operator carry the guarantee provided for these components.
This guarantee will not apply to any operator which:
a. Has been subject to misuse or which has been used for any purpose other than
designed for by Centurion Systems (Pty) Ltd
b. Has not been installed in accordance with the installation instructions provided.
c. Has damage caused as a result of handling during transit, atmospheric conditions,
insect infestation, power surges or other forces outside of our control
d. Has been repaired by any workshop and/or person NOT previously authorised by
Centurion Systems (Pty) Ltd
e. Has been repaired with components not previously tested, passed or authorised by
Centurion Systems (Pty) Ltd
All CENTSYS products are manufactured with extreme care, thoroughly inspected and tested. The
products are only guaranteed against faulty materials or workmanship for a period of 12 months
from the invoice date of the product, or 14 months from the manufacturing date (as shown on the
serial number label of the operator), whichever expires first.
The guarantee will cover the repair or replacement at our discretion of such faulty materials or parts
free of charge provided that the equipment is returned to our workshop.
This guarantee will not apply to any equipment which:
a. Has been subject to misuse or which has been used for any purpose other than
designed for by the manufacturers.
b. Has not been installed in accordance with the installation instructions provided.
c. Has damage caused as a result of handling during transit, atmospheric conditions,
insect infestation, power surges or other forces outside our control.
d. Has been repaired by any workshop and/or person NOT previously authorised by
Centurion Systems (Pty) Ltd
e. Has been repaired with components not previously tested, passed or authorised by
Centurion Systems (Pty) Ltd
Page 2
Product Guarantee A10Product Guarantee A10
Product Guarantee D3 and D5Product Guarantee D3 and D5

Centurion Systems (Pty) Ltd, South Africa, has been manufacturing automatic gate systems since 1986,
and is committed to providing reliable, cost effective solutions in the field of gate and access
automation.
We offer a diverse range of products including gate motors, GSM-based products, garage door motors,
remote controls, keypads, traffic barriers, proximity access control and intercom systems.
Our products are developed by an in-house team of talented engineers that are constantly researching
new and innovative technologies to improve our existing products and expand our product range.
Our production facility in Johannesburg is ISO:9001 quality assurance certified, and all our products are
manufactured to the highest level of quality with a 100% test to specification.
Through a team of dedicated technicians and sales personnel, together with a fully fledged in-house
training facility, we are committed to providing unmatched service to our customers and support for our
products.
A worldwide network of distributors and installers ensure that our products remain The Automatic
Choice in access automation .
Further information is available on our website www.centsys.com.au
© CENTURION SYSTEMS (PTY) LTD 2005
Company ProfileCompany Profile
Page 3
Centurion Systems (Pty) Ltd reserves the right to make changes to the products described in this document without notice and without
obligation of Centurion Systems (Pty) Ltd to notify any persons of any such revisions or changes. Additionally, Centurion Systems (Pty) Ltd
makes no representations or warranties with respect to this document.
No part of this document may be copied, stored in a retrieval system or transmitted in any form or by any means electronic, mechanical,
optical or photographic, without the express prior written consent of Centurion Systems (Pty) Ltd.

Introduction ........................................................................................................................................... 6
Models covered .................................................................................................................................... 6
Main features ........................................................................................................................................ 6
Normal operation .................................................................................................................................. 8
Radio transmitter ..................................................................................... 8
Intercom pushbutton ............................................................................... 8
Pedestrian keyswitch ............................................................................... 9
Controller features and functions .......................................................................................................... 10
Introduction .............................................................................................. 10
Anti-crushing device .............................................................................. 10
Automatic alignment ............................................................................... 11
Automatic closing ....................................................................................11
Autoclose override .................................................................................11
Mains failure detection .......................................................................... 12
Battery low protection ........................................................................... 12
Thermal overload ................................................................................... 12
Origin sensor fail ................................................................................... 13
Lightning protection ............................................................................... 13
Ancillary equipment .............................................................................................................................. 13
Protection beam ...................................................................................... 13
Holiday lockout ...................................................................................... 14
Courtesy light timer .............................................................................. 14
Pre-flashing ............................................................................................. 14
Gate status indication ............................................................................. 15
Solar panel ............................................................................................... 15
DC Converter module .............................................................................. 16
Reversing mode ....................................................................................... 18
Condominium .......................................................................................... 18
Passive infraRed Autoclose (PIRAC) ................................................... 18
Manual release ..................................................................................................................................... 19
Re-engaging the manual release .......................................................... 20
Page 4
Table of ContentsTable of Contents 6
6
6
8
8
8
9
10
10
10
11
11
11
12
12
12
13
13
13
13
14
14
14
15
15
16
18
18
18
19
20

Basic maintenance ................................................................................................................................. 20
General ..................................................................................................... 20
Battery ....................................................................................................... 21
Gearbox oil level ......................................................................................21
Power supply ............................................................................................ 21
A10 Inverter module .................................................................................. 22
Specifications ......................................................................................................................................... 23
D3/D5 Operator ........................................................................................23
A10 Operator .............................................................................................24
A10 DC Converter ..................................................................................... 24
Optional extras ...................................................................................................................................... 25
Declaration of Conformity .......................................................................................................................26
Commissioning check sheet ........................................................................................................
Page 5
20
20
21
21
21
22
23
23
24
24
25
26
27 & 28

This guide highlights the features and operation of CENTSYS SLIDING GATE
OPERATORS to ensure that you, the user, get the most from your system. Basic
maintenance is also described, but in the event of product malfunction, you are
advised to contact your installer, or your local Centurion Systems (Pty) Ltd outlet
(refertobackpage).
!CENTSYSD3slidinggateoperator
!CENTSYSD5slidinggateoperator
!CENTSYSA10slidinggateoperator
A key feature of these products is the chassis/gearbox which is moulded from a
high-tech engineering polymer. The user benefits from this material in terms of its
aesthetics, and corrosion-free properties. Due to the self-locking action of the
internalgearset,theunitisresistanttoforcedentry.
Anoptionaltheft-resistantcageisavailabletogiveadditionalpeaceofmind.
A revolutionary aspect of the CENTSYS range of operators is the limit switch
mechanism. Mounted internally, and therefore tamper proof, the limit switch
monitorsthespeedandlocationofthegate,ensuringreliableandsafeanti-crushing
protectionandaccuratepositioncontrol.
Precise control of the gate stopping position is achieved by a high resolution
encoderwheelandopto-electronicsensorbuiltintotheunit.
The electronic controller has many advanced features including variable sensitivity
collisiondetection,adjustabledelayAutoclose,pedestrianopening,etc.
Advancedlightningprotectionis builtintothecontroller as standard. On the D3 and
D5 domestic models, a 12V battery is the primary power source, thus providing a
limitednumberofoperationsintheeventofamainspowerfailure.
Thisbatteryisnormallychargedbyaninternal220V*charger.Forsiteswherea220-
240V mains supply is unavailable, an external 220-12V adaptor, or solar panel is
D3andD5
Page 6
IntroductionIntroduction
Models covered
Main featuresMain features

optional(seeSOLARPANEL,page17formoredetailsaboutsolarcharging).
Inmulti-userapplicationstheD5operatoris availablewithatransformerrectifierunit
(power-pack), which replaces the battery and charger. The power pack operates
directly off a 220V* mains supply only. Battery backup is available by simply adding
anexternallymountedbattery.
*Alternativevoltageratingsareavailableonrequest
Engineered for industrial and high-duty sites, the A10 is built around a precision-
machined,die-castaluminiumchassis/gearboxincorporatingaself-lockinggearset.
Accordingly,theunitisresistanttoforcedentry.
The integral electronic controller has similar functions to those of the D3 or D5 and
usesthesametechnologyintermsoforiginandencodersignalinputs.Uniquetothe
A10isthehighspeedmode,enablingadjustableopeningandclosing speeds up to
30metresperminute.
The key to the A10’s outstanding torque and duty cycle lies in the three-phase
induction motor and electronic inverter that form the heart of the system. Single-
phase 220-240V AC power is converted into variable frequency three-phase power,
allowingelectronicallycontrolledsoftstartingandstoppingofthemotor.
AnoptionalDCconverterisavailable,containing12VbatteriesandUPStypebackup
circuits.ThisenablestheA10tocontinueoperatingforalimitedperiodintheeventof
apowerfailure.Anotheroptionisthetheft-resistantcage, togiveadditionalpeaceof
mind.
“Endurance”and“HeavyDuty”derivativesoftheA10areavailabletosuithighduty,
and highgatemasssitesrespectively.
A10
Page 7

Thegatescanbeopenedorclosedinthefollowingway:
A handheld radio transmitter, carried in the motor car, sends a coded signal to the
receivermountedinthecontrolenclosuretoopenorclosethegate.
Radiotransmitter
A10
A10
Page 8
Normal operationNormal operation
Pressonceforapproximatelyonesecondtoinitiategatemotion.
If the transmitter is pressed while the gate is either opening or closing the gate will
immediatelystop.Pressingthebuttonagainwillcausethegatetoreverse.
If the automatic closing feature (see Controller Features and Functions) has been
selected and the gate is closing automatically when the transmitter is pressed, the
gatewillstopandstayinthatposition.Pressingthebuttonagainwillcausethegateto
re-open. If the gate is opening with the automatic closing facility selected, and the
transmitter is then pressed, the gate will stop. The gate will close automatically after
theAutoclosedelaytime.
Intercompushbutton
PRESS TO
OPEN GATE
Visitoroutsidegaterequestsentrance. Gateopenedfromintercom
pushbuttoninsidehouse.

Pedestriankeyswitch(optional)
The pedestrian keyswitch is fitted to the gate pillar. It’s purpose is to open the gate a
limitedamountforpedestrians.
!Fit the key into the keyswitch and
turn the key clockwise as though
startingamotorcar.
!Let key spring back to rest position
andremovekeyimmediately.
To allow time for removal of the key,
there is a five second delay before the
gatebeginstoopen.Ifthecourtesylight
is connected to the control card it will
flash five times, indicating that the
signalhasbeenaccepted.
The gate will open approximately one metre and then stop. After five seconds the
gatewillautomaticallyclose.
The gate can be held open by keeping the key turned in the keyswitch. As soon as
the key is released back to its normal rest position, the gate will close after the five
seconddelay.(Theopeningdistanceandthetimethatthegateremainsopencanbe
adjustedtosuit.Defaultvaluesaredescribedabove).
Ifaprotectionbeamhasbeenfitted(refersection“ProtectionBeams”)andthebeam
is broken while the gate is closing, the gate will stop. The gate will remain in that
position while the beam is broken and only close five seconds after the beam has
beencleared.
Page 9
Most automatic gate installations are fitted with an intercom which provides for
communicationbetweenthehouseandthegate.
The intercom handset is usually provided with a “Gate" or "Door Release”
pushbutton which, when pressed, sends a signal to the gate controller to open the
gate.
The sequence of operation of this pushbutton is identical to the radio transmitter
describedunder“RadioTransmitter”.

Introduction
Anti-crushingdevice
The electronic controller synchronizes the functions of the gate operator. Although
the controllers for each operator are marginally different, the functions and safety
featureswhicharedescribedbelowaresimilar.
Gateclosing
Gateopening
Gate closing into an obstruction Gate automatically reverses and re-opens
Gate opening Gate stops on hitting the obstruction
Page 10
STOP
Ifthegateisobstructedrepeatedlyfourtimes,eitheropeningorclosing,oftenreferred
toasmultiple collision,thegatewillstopandwillnotrespondtotriggerinputsfortwo
minutes.
After thistimethegatewillonceagainrespond tocommandsignals.Thisfunctionisa
warning to the user that the obstruction must be removed. (The number of obstruc-
tionsbeforethesystemwillshutdowncanbeadjustedtosuit,defaultisfour).
Controller features and functionsController features and functions

Automaticalignment
Automaticclosing(optional)
Autocloseoverride
CENTSYS operators are fitted with a manual override mechanism. This is to allow the
gate to be operated in the event of a total malfunction of the equipment. It is also
requiredifthemainspowerhasfailedinthecaseofthe220Voperators(A10models).
Whenacommandsignalisgivenafterthegatehasbeenmovedmanuallyandthenre-
engaged, the gate will drive to either it’s fully open, or closed, position. Referred to as
automatic alignment, the gate can only be stopped, but not reversed until the align-
mentcycleiscomplete.Thesystemwillthenreverttonormaloperation.
The system has the facility to automatically close the gate after it has been opened.
The default setting is that this facility is disabled. The time that the gate remains open
canbeadjusteduptofourminuteswherethedefaultis15seconds.
The Autoclose function can be temporarily overridden by holding down the remote
control pushbutton or intercom gate release when opening the gate, until the gate
stops. (Default setting is three seconds. It can be changed to suit.) This confirms
that the Autoclose has been overridden. On releasing the button, the gate will
continue to open fully, and remain open as long as required.
Closing the gate by using either the transmitter or intercom gate release button
resets the system back to Autoclose.
Page 11
PRESS and HOLD GATE RELEASE
FOR THREE SECONDS TO
OVERRIDE AUTOCLOSE
INTERCOM PUSHBUTTON or REMOTE

If a gate status indicator (LED) has been fitted inside the house, an additional
confirmation of the functioning of the override is provided. The status LED will
stop flashing and remain ON when the Autoclose has been overridden.
Althoughthesesystemswillcontinuetooperateintheeventofamainspowerfailure
dueto the built-in battery, itis important to register that there isa problem before the
batteryisrunflat.
The controller (CP80) monitors whether mains voltage (via the charger transformer)
is present. If not, the gate status LED, will flash twice every two seconds to indicate
mainsloss.
The controller has circuitry that monitors the state of the battery. During a power
failure energy is drawn from the battery, but not replaced. To prevent the battery
running flat and being damaged, the protection circuitry shuts off the gate system
whenthebatteryvoltagedropsbelow10.6V.
Mains failure detection (D3/D5 only)
Batterylowprotection(D3/D5only)
RED LED
STATUS
NOTE: - LED WILL FLASH THREE TIMES
EVERY TWO SECONDS TO INDICATE
BATTERY VOLTAGE IS LOW
- D3/D5 OPERATOR PCB SHOWN
If the gate status
indicator has not been
fitted inside the house,
there is an equivalent LED
mounted on the controller
marked “STATUS”
Page 12
Thermaloverload(A10only)
In the event of the A10 operator being used excessively and the duty cycle rating of
theunit exceeded,theunitwill shut downdueto thermaloverload inordertoprotect
thesystemfromabuse.
The unit cannot be re-operated until the unit has cooled. To provide indication to the
userthatthisisthecauseofthefaultthestatusLEDwillflashtwiceeverytwoseconds.

Ancillary equipmentAncillary equipment
Page 13
Protection beams (optional, but recommended)
Aninfraredbeam,orundergroundloopacrossthegateentrancemaybeconnected
to the controller as an additional safety feature. When a motor vehicle activates the
looporbeamthefollowingoccurs:
!Ifthegateisclosing,itwillimmediatelystopandreopen
!If the transmitter or intercom gate release pushbutton is pressed while the beam
is broken, or the loop activated, the gate will remain open. The Autoclose time will
restartitscountdown
Originsensorfail(A10only)
Lightningprotection
The A10 operator uses an origin switch to ensure it stops in the correct open and
closed positions. If this switch fails for any reason, the operator will shut down. To
provide indication to the user that there has been an origin sensor failure, the
status LED will flash three times every two seconds.
This condition is treated as serious and the unit cannot be activated again until the
gate has been moved manually either fully-open or fully-closed, ensuring that the
gate magnet has passed the sensor. If the sensor registers correctly, the unit will
reset, and can be operated again. If the sensor does not re-register, the unit will
remaininthelockedstate.
If the system cannot be reset by following the procedure above, it is a clear
indicationthatthe SENSOR is faulty or notswitching reliably. It is importantthat
theoperationoftheSENSORischeckedbyaqualifiedtechnician.
AllCENTSYS controllers have onboardlightningprotection.The protection circuitry
was designed in conjunction with the CSIR. Provided that the system has been
properly earthed the protection will significantly improve the resistance of the
systemagainstlightningstrikes.

Page 14
Holidaylockout(optional)
Courtesylighttimer(optional)
Pre-flashing
A keyswitch can be connected to the gate system that will allow the system to be
totally immobilised. The keyswitch is mounted with access from the outside of the
property. When the keyswitch is OFF, the gate system will shut down and it will not
be possible to operate the gate. When the keyswitch is ON, the gate system will
operatenormally.
This is an added security feature should the property be unattended for an
extendedlengthoftime.
TheHoliday Lock out facility couldalsobeactivatedusing a keypad, radio receiver
withalatchingoutputoranON/OFFtoggleswitch.
If a 220V power supply is available at the gate, timed courtesy lights can be
connected through the controller. Each time the gate is opened, the lights will
switch on for a period of time and switch off. The time can be adjusted up to forty
minutesintensecondincrements.
A courtesy light pushbutton can be mounted inside the house (typically on the
intercom)allowingconvenientcontrolofthelights.Bypressingthepushbutton.
Bypressingthecourtesylightpushbutton(iffitted),momentarilythelightwillswitch
on for the light timer period and automatically switch off. By pressing and holding
thepushbuttondownforthreesecondsthelightswillswitchonandremainon.The
status LED (if fitted) will flash once every two seconds to confirm this. To switch off
the lights, press the pushbutton momentarily. If courtesy lights are fitted to the
controller,andthepedestriankeyswitchisoperated,thecourtesylightswillflashfor
five seconds before the gate opens. This warns the pedestrian that the gate will
openwithinfive secondsallowing time to remove the key and stand back fromthe
gate.
The courtesy light can be programmed to flash for a period of time before the gate
starts to open or close. The courtesy light timer will function as normal. (Pre-flash
time can be adjusted to suit, from 1 to 250 seconds, where the default is five
seconds).Bydefaultpre-flashingisoff.

LED STATUS
Slow regular flash
Quick regular flash
Off
On
1 Flash/2 seconds
2 Flashes/2 seconds
3 Flashes/2 seconds
4 Flashes/2 seconds
INDICATION
Gate is opening
Gate is closed
Gate is open
Battery low (D3/D5 only. See Battery
LowProtection, page 13)
Missed origin (A10 only. See
Origin Sensor Fail, page 14)
Collision shutdown
(See Anti-crushing Device, page 11)
Mains failure (D3/D5 only. See Mains
Failure Detection, page 13)
Courtesy light switched on (see
Courtesy Light Timer, page 15)
Gate is closing
Or:
Or:
Over temperature (A10 only. See
Thermal Overload, page 14)
Page 15
Gatestatusindication(optional)
The controller can provide visual indication inside the house of the position of the
gateandthe condition of the battery andpower supply. An LED istypically mounted
on the intercom inside the house. The different signals of the LED are shown in the
followingtable:

Page 16
SOLAR
PANEL
The310VDC supply ishazardousand potentially lethal.
The A10 DC converter module should be installed and
maintainedbyaqualifiedinstaller.
WARNING
Solar panel (optional on
D3/D5systemsonly)
DC Converter module (optional for A10 only)
Thefollowingfeaturesareofinterest:
The battery of the 12V DC operator may be
charged using a solar panel in place of the
conventional charging circuit. A 12 Watt
panel will provide on average 10 - 12
operations of an average gate without
causing the battery to discharge over a
periodoftime.
It is necessary to have at least a 35Ah deep cycle low-maintenance battery fitted, in
ordertoprovidesufficientbackupcapacityduringdaysofpoorweather.
ForfurtherdetailscontactyourlocalCENTSYSagent.
TheDCconvertermoduleallowstheA10gateoperatortofunctionfroma12Vbattery
intheabsenceofACmains.Theconvertermodulestepsupthe12Vbatterysupplyto
310V DC. The inverter drive on the A10 operator then switches the high voltage DC
supplytorunthethree-phaseinductionmotor.
Theconvertermoduleincludesbatteryprotectioncircuitry.Thiscircuitrypreventsthe
convertermodulefrombeingdamagedintheeventofreversepolarityconnection.In
addition the circuitry automatically disconnects the battery when the battery drops
intoalow-voltagestate.Thispreventstheconvertermodulefromrunningthebattery
flatandpotentiallydamagingthebattery.
Thereisapushbutton ontheconvertermodulethatmanuallyreconnects thebattery
intheeventofapowerfailureandlowbatteryvoltagestate.
Upon activation, and if the battery voltage exceeds the low-voltage parameter, the
protection circuitry will automatically keep the battery connected to the converter. If,
ontheotherhand,thebatteryvoltageisbelowthelow-voltageparameter,the

Page 17
AC Mains
Converter
temperature
Mains
present
Overheated
Mains
failure
Converter
temperature
normal
DC converter will
power A10 until
mains restored or
battery voltage <
threshold.
LED
Battery
status Battery is
fully charged Voltage
low
DC converter will
shut down until
battery reaches
normal operating
voltage.
When ON,
it indicates: When OFF,
it indicates:
Logic Logic
DC converter will
shut down until it
has cooled to
normal operating
temperature range
protectioncircuitrywillnotconnectthebatterytotheconverter.
The DC Converter module has three status LEDs. These LEDs indicate battery
status, AC mains status, and lastly the temperature of the converter. The LEDs
operateinthefollowingmanner:
Theconvertermodulehasacurrentlimitingfuseonthehigh-voltagesupply.Caution
mustbeexercisedwhencheckingthisfuse.
Theproceduretoreplacethefuseisoutlinedbelow:
1. Disconnect the mains from the entire system. This includes the A10, and
theconvertermodule
2. Disconnectthebattery
3. Disconnect the six-way header that connects the converter module to the
A10.Theconvertermoduleisnowoff,andtheboardissafetohandle
4. Removethefuseprotectionhousing(Ifthehousingisstillinplace)
5. Removethefuseandreplaceitwitha5A,250V,fast-blowfuse.(Dimensions
5mm x 20mm)
6. Reconnectthesix-wayheader
7. Reconnectthebattery
8. Reconnectthemains
Upon reconnecting, if the converter module fails to function correctly in the event of
apowerfailure,refertoaninstallerorservicetechnician.

ReversingMode
Condominium
Passive Infrared Autoclose (PIRAC)
Apart from the Standard Mode of Operation as described in the section Normal
Operation, the system offers another Mode of Operation. Referred to as Reversing
Mode, if the transmitter is pressed while the gate is moving, the gate will automati-
cally reverse direction. The gate can never be left in mid position with this mode
selected.
Other Modes of Operation which can be selected and operated using a radio
transmitterareCONDOMINIUMandPIRAC,whicharedescribedbelow.
The system can be programmed for “Condominium” operation. This Mode of
Operation will override the normal Mode of Operation described under the section
“Normal Operation”. This facility is designed for greater safety and security in
applications where there will be a number of users, such as the gate at a townhouse
estate,factoryorofficeparkthe“Autoclose”facilitydescribedearlier.
In “Condominium” mode “Autoclose” cannot be overridden. If the remote control or
intercom pushbutton is pressed while the gate is open the “Autoclose” will restart its
countdown. If the gate is activated while the gate is closing the gate will reopen. The
gatecannotbestoppedinamidwaypositionandwillthereforealwaysclose.
A protection beam should be used in conjunction with this facility to prevent the
“Autoclose”fromclosingthegateontoavehiclepassingthrough.
This facility is an extension of the Condominium facility described above. It is
designed for applications requiring greater security as the gate closes immediately
behindthevehicleorpersonpassingthrough.
PIRACwilloperateonlyifaprotectionbeamorothertypeofvehicledetectionsystem
(e.g.Inductiveloop)hasbeenfitted.
The remote control or intercom pushbutton will only open the gate. As a vehicle
drives through the entrance it activates the protection beam and as soon as the
vehicleclearsthebeamthe gatewillclose immediately,evenbefore itisfully open.If
the gate reaches the fully open position without the beam being activated the gate
willcloseimmediately.
Inthismode andfor aparticularapplicationshouldthegatestarttoclosetooquickly
Page 18
Special FunctionsSpecial Functions

A10
A10
A10
A10
the"Autoclose"facilitydescribedearliercanbeenabled.
The gate will now remain in the open position until either the "Autoclose" facility has
timed out, or a vehicle has driven through the entrance, in which case the gate will
starttocloseimmediatelythevehiclehaspassed.
Alloperators are fittedwithamanual release mechanism.Thisisto allow the gateto
be operated in the event of a total malfunction of the equipment. It is also required if
themainspowerhasfailedinthecaseoftheA10(withoutDCconverter)operator.
Rotate thumbwheel clockwise
until gate is free to move
Manual release
handle in closed position. Open lock cover and insert key.
Turn key ¼ turn counter
clockwise to unlock.
Pull manual release handle
down to disengage manual
release
Open manual override
Page 19
Manual releaseManual release
CENTSYS D3 and D5
CENTSYS A10

CENTSYS operators are designed to be maintenance-free. However, there are
some basic checks that should be carried out regularly (every six months). These
willincreasethelongtermreliabilityofthesystem,andobviatefalsetriggeringofthe
protectionsystemsleadingtoerraticoperationofthegate.
Isolatemainssupplytosystembeforecleaningorworkingontheequipment.
!Keep the track clear of stones, dirt and
obstructions.
!Ensurethatallrollersarefree.
!In manual mode check that the gate runs
freely on its rail and does not catch or foul
againstthewallsorpillars.
!Ensure that the gate wheels and guide
rollersarerotatingfreelyandarenotworn.In
highvolumeapplicationsitwillbenecessary
toreplacethesecomponentsregularly.
!Ensure that the rack is properly secured
to the gate and that it does not press down
ontotheoperatorpinionatanypointalongitstravel.
!Keepshrubsandvegetationclearofthemotor,rackorchain.
!Check that the key still operates the manual override access door or flap. Spray
withoilifnecessary.
!Keeptheinsideofthemotorhousingclearofinsectsanddust.
!On operators fitted with a cooling fan, check that the air inlet ducts in the cover
andtheoutletductsinthegearboxareclear.
General
Re-engaging the manual release (A10 only)
It is strongly recommended that the gate is first pushed to the fully open
position, and then to the fully closed position before the release handle is re-
engaged. This is to ensure that no untoward behavior occurs due to the
system having lost its position information.
Page 20
Basic maintenanceBasic maintenance
This manual suits for next models
2
Table of contents
Other Centsys Gate Opener manuals

Centsys
Centsys VECTOR2 User manual

Centsys
Centsys D10 Turbo User manual

Centsys
Centsys D5-Evo User manual

Centsys
Centsys D5-Evo Quick start guide

Centsys
Centsys A10 User manual

Centsys
Centsys D5-Evo User manual

Centsys
Centsys R3 User manual

Centsys
Centsys A10 User manual

Centsys
Centsys Vector2 400 User manual