The RTIC-2210-WP is short circuit protected. Batteries are
a high current source and additional protection is needed
it.
clean and tight. See installation diagrams below.
that the amount of charge and discharge be equal for both
series.
Safety instructions
CAUTION: The following are important safety instructions.
Save these instructions.
cell” rechargeable batteries. Other types of batteries may
burst causing personal injury or damage.
battery.
battery.
and get immediate medical attention.
or replacement is required. Incorrect reassembly may result
used. Only adults should install and operate the charger.
children.
quality grounded extension cord of at least 16 awg wire size
for cords up to 50 feet and a minimum of 14 awg for cords
up to 150 feet.
grasp the plug when disconnecting the charger.
The RTIC-2210-WP is waterproof and designed for harsh
consult the factory if there are any questions.
factory.
Study the battery manufacturer’s precautions such as
Keep batteries full. Add distilled water in each cell until it
Good battery maintenance procedures dictate that the battery
ambient temperatures.
Keep the battery terminals clean. Always unplug the charger
before cleaning. Keep corrosion from coming into contact
with your eyes.
battery. A lead-acid battery can produce a short circuit high
Three stage charging curve
Three stage charge cycle
The RTIC-2210-WP employs a three stage charge routine. This
is the charging procedure most lead-acid battery manufactur-
battery life.
Stage 1: Constant current or bulk charge mode
charger is operating in constant current mode. The charger
is allowed to rise as it is being recharged. Approximately 80%
of battery capacity is returned in the constant current region.
Stage 2: Absorption mode
is fully charged.
Stage 3: Float mode
charge condition of the battery without boiling out electrolyte or
lights on the RTIC-2210-WP should be green.
Installation
Location
as fan wheels.
Operating temperature is -10°C to 55°C (-14°F to 131°F).
Storage temperature is -30°C to 80°C (-22°F to 176°F).
-
rimeter and top side of the charger.
Mounting
drilling mounting holes near a battery.
Electrical
AC wire connections
The RTIC-2210-WP is equipped with a factory installed 6 foot
AC cord with a ground connection. The ground connection
is the round pin on the AC plug. It is extremely important
that only grounded electrical outlets or extension cords
with a ground connection should be used when operating
this charger.
are wet or barefoot.
necessary.
The charger will operate properly with 220VAC 50/60Hz
DC wire connections
DC wire connections must be made before plugging in the
AC cord.
The charger should only be used with lead-acid type batteries
in.
When installing in the bilge of boats or any battery
health and safety.
Keep wire routing from the charger to the battery neat and
parts and hot surfaces such as exhaust components.
Battery
voltage
Stage 1: Bulk
(constant current)
Stage 2: Absorption
(constant voltage)
current decreasing
Battery
current
Absorption
full charge maintained
Stage 3: Float
(constant voltage)
Float
Bulk
Two 12V battery connection
One 24V battery connection