CHERUBINI META 4 CH PWM DIMMER 7 User manual

DRAFT
ISTRUZIONI - INSTRUCTIONS - EINSTELLANLEITUNGEN
INSTRUCTIONS - INSTRUCCIONES
Dimmer 4 canali
4-channel dimmer
4-Kanal-Dimmer
Variateur 4 canaux
Actuador de iluminación de 4 canales
IT
EN
DE
FR
ES
META
4 CH PWM Dimmer 7


14
TRANSLATION OF THE ORIGINAL INSTRUCTIONS
Index:
Device description ................................................................................................. p. 15
Technical specications.......................................................................................... p. 16
Safety information ................................................................................................. p. 16
Electrical connections diagram .............................................................................. p. 17
Device installation.................................................................................................. p. 17
LED status indicator ............................................................................................... p. 18
Add/remove the device into a Z-Wave network (classic)........................................ p. 19
SmartStart inclusion............................................................................................... p. 20
S2 Secure Inclusion ................................................................................................ p. 20
Supported command classes ................................................................................. p. 21
Device control........................................................................................................ p. 22
Controlling the device by External Switches ....................................................... p. 22
Controlling the device by a Z-Wave controller .................................................... p. 22
Associations........................................................................................................... p. 23
Reset to the factory settings .................................................................................. p. 23
Firmware update.................................................................................................... p. 23
Congurations ....................................................................................................... p. 24
EU declaration of conformity
CHERUBINI S.p.A. declares that the product is in conformity with the relevant Union
harmonisation legislation: Directive 2014/53/EU, Directive 2011/65/EU.
The full text of the EU declaration of conformity is available upon request at the following
website: www.cherubini.it.
Failure to comply with these instructions annuls CHERUBINI’s responsibilities and
guarantee.
The crossed-out wheelie bin symbol indicates that the product must be collected
separately from other waste at the end of its useful life. Therefore, users should
deliver this product to appropriate waste collection points or return it to their
dealers at the end of its service life. See your local authority’s regulations.
Adequate waste sorting for subsequent processing and environmentally compatible
disposal helps to avoid possible negative effects on the environment and public health
and promotes reuse and/or recycling of the materials used to make the equipment.
ENGLISH

META 4 CH PWM Dimmer 7 is four channel PWM dimmer controllable through Z-Wave
protocol, for constant voltage LED loads, such as LED strips, halogen lights and constant
voltage LED modules. Controlled devices may be powered by 12 or 24 VDC
It is connected between a 12-24 VDC power supply and the constant voltage LED load. It
can control up to four channels of lighting applications. The maximum combined output
current is 12 A and 6A maximum per each channel.
It operates in any Z-Wave network with other Z-Wave/Z-Wave Plus certied devices
and controllers from any other manufacturer. As a constantly powered node, the device
will act as repeater regardless of the vendor in order to increase the reliability of the
network.
This device is a security enabled Z-Wave Plus product that is able to use encrypted
Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products.
This device must be used in conjunction with a Security Enabled Z-Wave Controller in
order to fully utilize all implemented functions.
Integrated Button 1 or 3 clicks to enter in Learn Mode
6 clicks to reset the system to manufacturer’s settings
Power Supply 12-24 VDC (+, -)
Input Switch
IN 1, 2, 3, 4
Output
OUT 1, 2, 3, 4
15
DEVICE DESCRIPTION
Integrated Button
ENGLISH

TECHNICAL SPECIFICATIONS
SAFETY INFORMATION
Power supply 12/24 VDC
Maximum Load 6A for channel, 12 A in total
System temperature limitation 105 °C
Work temperature From -10° to 40° C
Power consumption <1 W
Radio frequency 868,4 MHz
Protection system S2 Security
Maximum distance Up to 100 m outdoor
Up to 40 m indoor
Dimensions 37x37x17 mm
Actuator element 4 Power Mosfet
Compliance CE, RoHs
Electrical IP Rating IP20
16
INFO: The device is designed to be installed in ush mounting junction boxes or
close to the load to be controlled.
WARNING: The device must be installed by electricians qualied to intervene
on electrical systems in compliance with safety requirements set out by the
regulations in force.
DANGER: Any procedure requiring the use of the Integrated Button is related
only to the installation phase and is to be considered a service procedure that
must be performed by qualied personnel. This operation must be performed
with all necessary precautions for operating in areas with a single level of
insulation.
WARNING: Do not connect loads that exceed the maximum load permitted by
the actuator element.
WARNING: All connections must be performed according to the electrical
diagram provided below.
WARNING: The device must be installed in norm-compliant systems suitably
protected from overloads and short circuits.
ENGLISH

ELECTRICAL CONNECTIONS DIAGRAM
17
ENGLISH
1) Make sure the main switch is set to the OFF position
2) Connect the device based on the diagrams provided
3) Turn the main switch to the ON position
4) Include the device in the Z-Wave network
DEVICE INSTALLATION
TIP: The antenna must not be shortened, removed or
modied. To ensure maximum efciency, it must be
installed as shown.
Large size metal equipment near the antenna can negatively
affect reception. Each device is a node in a mesh network. If
there are metal obstacles, the obstacle can often be overcome
with a further triangulation node.

18
LED STATUS INDICATOR
The system includes an RGB LED that shows the device’s status during installation:
Solid RED: the device is not included in any network
Solid BLUE: the device is Ofine setup mode
4 GREEN blinks then OFF: the device has been just added to a Z-Wave network in S2
Authenticate Mode
4 BLUE blinks then OFF: the device has been just added to a Z-Wave network in S2
Unauthenticated Mode
4 RED blinks then OFF: the device has been just added to a Z-Wave network without
security
Sequence of GREEN-BLUE Learn Mode for inclusion
Sequence of RED-BLUE Learn Mode for exclusion
TIP: To test if the electrical connections are correct, before the inclusion of the
device, while pressing ntimes the external switch, the RGB LED should ash
green for the same amount of times. If it does not, check the wire connections.
ENGLISH

19
ADD/REMOVE THE DEVICE INTO A Z-WAVE NETWORK
(classic)
Standard Inclusion (add)
All META Serie 7 devices are compatible with all Z-Wave/Z-Wave Plus certied
controllers. The devices support both the
Network Wide Inclusion
mechanism (which
offers the ability to be included in a network, even if the device is not directly connected
to the controller) and
Normal Inclusion
.
By default, the inclusion procedure starts in
Normal Inclusion
mode and after a short
timeout the procedure continues in
Network Wide Inclusion
mode that lasts for about
20 Seconds.
Only a controller can add the device into the network. After activating the inclusion
function by the controller, the device can be added by setting it in Learn Mode.
Before including the device, the LED status indicator is solid RED. The adding of a
device is executed by activating the adding procedure in the inclusion section of the
controller interface and then executing 1 or 3 click on the integrated button. As soon
as the inclusion procedure initiates the LED indicator starts a sequence of GREEN-
BLUE blinks. The device is included in the network when the LED status is OFF and the
interview is completed.
Standard exclusion (remove)
Only a controller can remove the device from the network. After activating the exclusion
function by the controller, the device can be removed by setting it in
Learn Mode
.
The procedure of exclusion can be activated by Removing a node from the Z-Wave
network and executing 1 or 3 click on the integrated button; as soon as the exclusion
initiates, the LED indicator starts a sequence of RED-BLUE blinks. The device is excluded
from the network when the LED status indicator is solid RED and the App_status in the
interface is OK.
ENGLISH

20
SMARTSTART INCLUSION
Z-Wave SmartStart aims to shift the tasks related to inclusion of an end device into a
Z-Wave network away from the end device itself, and towards the more user-friendly
interface of the gateway.
Z-Wave SmartStart removes the need for initiating the end device to start inclusion.
Inclusion is initiated automatically on power-ON and repeated at dynamic intervals
for as long as the device is not included into a Z-Wave network. As the new device
announces itself on power-ON, the protocol will provide notications, and the
gateway can initiate the inclusion process in the background, without the need for user
interaction or any interruption of normal operation. The SmartStart inclusion process
only includes authenticated devices.
META Serie 7 devices can be added into a Z-Wave network by scanning the Z-Wave
QR Code present on the product with a controller providing SmartStart inclusion. No
further action is required and the SmartStart product will be added automatically
within 10 minutes of being switched on in the network vicinity.
The SmartStart QR and the full DSK string code can be found on the back of the device.
The PIN is the rst group of 5 digits printed underlined. If you plan to use the DSK, it is
important that you take a picture of the label and keep it in a safe place.
S2 SECURE INCLUSION
When adding META Serie 7 devices to a Z-Wave network with a controller supporting
Security 2 Authenticated (S2), the PIN code of the Z-Wave Device Specic Key (DSK) is
required. The unique DSK code is printed on the product label. The rst ve digits of the
key are highlighted and underlined to help the user identify the PIN code.
Pin Code
ENGLISH

21
SUPPORTED COMMAND CLASSES
Command Class Version Non-Secure
CC
Secure CC
ZWAVEPLUS_INFO 2
x
ASSOCIATION 2
x
MULTI_CHANNEL_ASSOCIATION_V2 3
x
ASSOCIATION_GRP_INFO 3
x
TRANSPORT_SERVICE 2
x
VERSION 3
x
MANUFACTURER_SPECIFIC 2
x
DEVICE_RESET_LOCALLY 1
x
INDICATOR 3
x
POWERLEVEL 1
x
SECURITY_2 1
x
SUPERVISION
1x
MULTI_CHANNEL_V4
4x
FIRMWARE_UPDATE_MD 5
x
APPLICATION_STATUS 1
x
CONFIGURATION_V4 4
x
SWITCH_MULTILEVEL
3x
Supporting Command Class Basic
The basic command classes are mapped into the Switch Binary Command Class.
Supporting Command Class Indicator
The device supports the command class Indicator V3 (ID 0x50). When the device
receives an indicator set, the led blinks accordingly to the Indicator set received.
The color shown by the indicator will be:
RED: if the device is included without Security
BLUE: if the device is included in S2 Unauthenticated Mode
GREEN: if the device is already included in S2 Authenticated Mode.
ENGLISH

22
DEVICE CONTROL
META 4 CH PWM Dimmer 7 can turn ON and OFF the load by using an external switch
(Momentary switch), or from remote through a controller.
Controlling the device by External Switches
For the operation of the device within the Z-Wave network and controlling the loads
connected to the device, control actions are performed on the external switches.
Event Type of switch
Actions on the switch
Click
Momentary switch
(button)
Press briey & Release
(when pressed it autonomously
returns to the initial position)
MultiClick=nclicks Momentary switch Sequence of consecutive nclicks
Hold Down Momentary switch
Press longer than click.
After a Hold Down always follows
an UP event.
Up Momentary switch
Release.
The event applies only if there has
been a previous Hold Down event.
ENGLISH
The CONTROL ACTIONS are EVENTS executed on EXTERNAL SWITCHES
(connected between the 12-24 VDC (-) Terminal and one of the INPUT 1, 2, 3, 4
of the device), which can be
Clicks,
Hold Down and Up
.
Controlling the device by a Z-Wave controller
The device can be controlled by any Z-Wave / Z-Wave Plus certied controller available
in the market.

23
ENGLISH
ASSOCIATIONS
META 4 CH PWM Dimmer 7 supports 1 association group, which supports the
association of up to 8 devices (nodes):
Group
ID
Group
Name
N° max
nodes Description
Command sent
1Lifeline 8Lifeline Group
DEVICE_RESET_LOCALLY_
NOTIFICATION
SWITCH_MULTILEVEL_
REPORT
INDICATOR_REPORT
FIRMWARE UPDATE
RESET TO THE FACTORY SETTINGS
The system supports over-the-air rmware updates that do not require the device to
be removed from its location. The rmware update can be activated from all certied
controllers supporting version 2 of the Firmware Update function.
The device can be reset to the original factory with 6 consecutive clicks on the
integrated button.
After the reset is completed, the device will reboot and a RED solid led is showed.
INFO: If the reset is performed while the device is still part of a network, it
noties the other devices that it has been removed
(Device Reset Locally
Notication).
WARNING: The system will be rebooted at the end of the rmware update
procedure. It is advisable to carry out the rmware update procedure only when
necessary and following careful planning of the intervention.

24
ENGLISH
CONFIGURATIONS
Parameter
Number Size Parameter
Name
Default
Value Description
50 4 DIMMING_
TIME 3Fade On/Off time in seconds used when
the device is controlled with the switch
Parameters Values Min: 0 Max: 3600
Value Description
0-3600 Specic time expressed in seconds

Rev: 1 02/2022 - Cod: A4516_6P52
CHERUBINI Deutschland GmbH
Siemensstrasse, 40 - 53121 Bonn - Deutschland
Tel. +49 (0) 228 962 976 34 / 35 | Fax +49 (0) 228 962 976 36
info@cherubini-group.de | www.cherubini-group.de
CHERUBINI France S.a.r.l.
ZI Du Mas Barbet
165 Impasse Ampère
30600 Vauvert -France
Tél. +33 (0) 466 77 88 58 | Fax +33 (0) 466 77 92 32
info@cherubini.fr | www.cherubini.fr
CHERUBINI Iberia S.L.
Avda. Unión Europea 11-H
Apdo. 283 - P. I. El Castillo
03630 Sax Alicante - Spain
Tel. +34 (0) 966 967 504 | Fax +34 (0) 966 967 505
info@cherubini.es | www.cherubini.es
CHERUBINI S.p.A.
Via Adige 55
25081 Bedizzole (BS) - Italy
Tel. +39 030 6872.039 | Fax +39 030 6872.040
info@cherubini.it | www.cherubini.it